Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.8 L+₹1.0 L (10.5%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹11.8 L+₹2.0 L (20.4%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹13.5 L+₹3.7 L (38.0%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹16.1 L+₹6.2 L (63.8%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
28 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NASIRABAD
GE Nasirabad Nasirabad cant, Pin 305601 (raj)
SPECIAL REPAIR/REPLACEMENT OF CONVENTIONAL STREET LIGHTS IN TO LED STREET LIGHTS, PROVN OF SMART LIGHTING SYSTEM, PROVN OF LIGHTENING CONDUCTOR FOR BLDG NO. P-54 AND PROVN OF 06 LED SECURITY LIGHTS IN NASIRABAD CANTT
2021_MES_464500_1
8177/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
NASIRABAD
AS PER NIT and Class E and above and category b(i) Low tension works(upto 1100 Volts)
6 documents required · 6 mandatory
₹500
GE NASIRABAD
₹39,000
Yes
27 Oct 2021
2 Aug 2021
30 Aug 2021
2 Aug 2021
28 Aug 2021
16 Aug 2021
2 Aug 2021 - 9 Aug 2021
60 days
Amount
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, laying of cables/pipes/poles etc., and getting out in hard/dense soil, complete all as specified and directed.
All as per description of serial item No.1.00 above but exc 1.50m and n.exc 3.0m deep complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding of 25 cm thick in soft/loose soil complete all as specified and directed
Removal of surplus soil as obtained from excavation to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point, all as specified and directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed by Engineer-in-charge Note:-Punned thickness only shall be measured and paid.
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-charge.
Supplying and fixing or laying, 80mm bore, light grade , galvanised mild steel pipe / tubing, complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction. . (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule ):-
All as per description of serial item No 7.00 above but 50 mm bore pipe.
All as per description of serial item No 7.00 above but 40 mm bore pipe.
M&L for drilling horizontal holes under roads/ pavements/ hard standing etc. at a depth as directed but not less than 1.00 m below existing Ground level, of suitable dia to accomodate pipes upto 80 mm dia, with using phenumetic drills/ ultra sound machanism for horizontal boring for passing of cable etc. complete all as specified & directed.
Dismantling of old unserviceable ACSR conductors from existing PCC/RCC/Steel poles.
Dismantling of old unserviceable insulators any type & any size from pole (PCC/RCC/Steel )
Dismantling of Cross arms of MS channel or angle section etc complete.
Dismantling stay assembely complete with stay wire.
Dismantling, taking down unserviceable street light fitting of HPSV/CFL/FL any size and model keep aside for reuse only conditiong lights all as specified & directed.
Dismantling/taking out old underground cable, service connection cable of any grade/type of size as below from pole/wall/cable duct/underground trench etc, keeping serviceable cables from site all as specified as directed by Engineer-in-Charge
Dismantling /taking out old unserviceable cable protection pipe 40/50/80 mm dia, complete all as specified & directed.
Dismantling/taking out old unserviceable/ broken street light bracket, complete all as specified & directed.
Dismantling/taking out old unserviceable street light timer complete all as specified & directed.
Dismantling/taking out old unserviceable street light control box any type/model all as specified & directed.
S&F street light Engineering plastic one piece moulding control box with locking arrangment made out of HDPE and FI clamp 25 x 3 mm complete including MCB SP 6 Amp 240 Volts complete with 02 Nos aluminium busbar of rating 63 amps for single phase and neutral on porcelain based insulators and fixing clamps to pole for street lights, complete all as specified & directed at site. Make : Sintex/ Hensel/ SHI/BRITE
S&F street light Engineering plastic one piece moulding control box with locking arrangment made out of HDPE and FI clamp 25 x 3mm complete including MCB SP 6 Amp 240 Volts complete with 04 Nos aluminium busbar of rating 63 amps for three phase and neutral on porcelain based insulators and fixing clamps to pole for street lights, complete all as specified & directed at site. Make : Sintex/ Hensel/ SHI/BRITE
Laying only, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross sectional area 16 Sqmm, 4 core , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Note :- (i) LT Cables XLPE insulated will be issued under schedule 'B' free for laying/fixing only. (ii)Excavation and earth work shall be measured and paid separately under BOQ
All as per description of serial item No 23.00 above but cross sectional area of cable 10 Sqmm, 4.0 core, Solid aluminium conductor
All as per description of serial item No 23.00 above but cross sectional area of cable 10 Sqmm, 2.0 Core, Solid aluminium conductor
S&F 1100 volts grade heavy duty cable PVC insulated copper conductor served with inner sheathing of PVC tape and overall PVC sheathed of size 1.5 Sqmm 3 core for fixing of security lights from pole to connector DB, complete all as specified and directed.
S&F high density polyethylene pipe (HDPE) 15mm bore fixed to electric pole fixing with 20 x 3 GI/aluminium clamps with every 1 m spacing. Make : Oriplast / Bansal / Supreme
Fixing only LED street light luminaries 70/72 Watt LED to fixing Steel tubular Pole/PCC Pole including connection with supply and testing the street light fitting after fixing, making the fitting functional complete all as specified and directed. Note :- (a) LEd Street light will be issued under Sch 'B' free for fixing only (b) Connection of PVC insulated copper conductor shall be measured and paid saparately.
Taking out old unserviceable street light at various locations and fixing only serviceable street lights retrieved from item No 15.00 on same / another location, complete all as specified and directed.
S&F GI bracket made out of GI Pipe light grade of size 40mm bore, 1.2 m long cut to length bend to the required shape and 02 Nos mounting flat iron clamps of size 40mm x 6mm, 04 Nos hexagonal bolts 10mm dia 100mm long with nuts and washers, complete all as specified & directed.
Supply, fixing and testing Street light automatic Nature switch of capacity 5 KW single phase complete with using infrared sensor based NATURE SWITCH for automatic switching of street lights. Nature Switch operation should be based on Nautral Light Lux* level. Required illuminance level for switching ON is ≤ 30 Lux and for swiching OFF ≥ 10 Lux. The sensor should also have part night operation facility of min.4 hrs to max 12 hrs. The sensor along with suitable power contactor(s) and incoming-outgoing MCBs should be enclosed in a pole/wall/panel mountable Rust proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure ( with Hinged LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation(i.e Sensor By-Pass option). Make-Kakatiya Energy system Model SWADEEP-66-5KW 1P
Supply, fixing and testing Street light automatic Nature switch of capacity 8 KW three phase complete with using infrared sensor based NATURE SWITCH for automatic switching of street lights. Nature Switch operation should be based on Nautral Light Lux* level. Required illuminance level for switching ON is ≤ 30 Lux and for swiching OFF ≥ 10 Lux. The sensor should also have part night operation facility of min.4 hrs to max 12 hrs. The sensor along with suitable power contactor(s) and incoming-outgoing MCBs should be enclosed in a pole/wall/panel mountable Rust proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure( with Hinged LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation(i.e Sensor By-Pass option). Make-Kakatiya Energy system Model SWADEEP-66-8KW 3P
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate of size 600X600X300mm including form work and plastering in CM 1:4 and three coat of white wash complete all as specified and directed.
Fixing only street light control box single phase with locking arrangment made out of HDPE and FI clamp , complete all as specified & directed . Note :- (i) Single Phase Control Box will be issued under schedule 'B' free for fixing only.
Fixing only street light control box three phase with locking arrangment made out of HDPE and FI clamp , complete all as specified & directed . Note :- (i) Three Phase Control Box will be issued under schedule 'B' free for fixing only.
Supply and connecting 1100 volts grade heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed of size 4 sqmm 2 core for pole box to street light fitting complete all as specified and directed.Make: Havells/Polycab
Fixing only Street light automatic control Nature switch of capacity 5 KW single phase complete fixing on a steel tubular pole,PCC pole , Panel etc., complete all as specified & directed by EIC. Note:- (i) Street light automatic Nature switch will be issued under schedule 'B' free for fixing only.
Fixing only Street light automatic control Nature switch of capacity 8 KW three phase complete fixing on a steel pole, PCC pole , panel etc., complete all as specified & directed by EIC. Note:- (i) Street light automatic Nature switch will be issued under schedule 'B' free for fixing only.
S & F aluminum air termination, single pointed aluminium rod 12 mm dia and 300 mm length all as specifed and directed.
S & F aluminium strip of size 25 x 3.15 mm on wall / on roof with seasoned wood block support of size 100 mm x 100 mm x 150 mm fixed on wall by 200 mm long bolts grouted in wall / on roof and over roof with proper junction joint & bonds fastened with nuts bolts & washers/screw of size as per site requirement including connecting one end to air termination rod & another end to test point terminal box complete all as specified and directed.
S&F galvanised iron strip 32 x 6 mm burried in ground /passing through pipe complete all as specified and directed.
M&L for test point terminal box/block made of gun metal or phosphorus bronze of size 75 x 75x 25mm, drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal heads screw after taking down old unserviceable test point terminal box, complete, all as directed.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work in any type of soil including laying the GI pipe concealed in floor /wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion.. (Note : 1. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost to govt.)
M&L for point wiring with 2.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for one light point controlled by one, one way switch.
S&F switch piano flush type 15 Amps, single pole one way 240 volts.
S&F socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type ISI marked complete.
Supply, installation, testing and commissioning of water heater storage type, electric suitable for single phase, 50HZ, AC supply, stainless steel inner assembly, 1.5 KW heating element, Twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1M of three core 2.5 sq mm twisted copper conductor cable PVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6Kg/sq,CM with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at ends, at hot water outlet, with safety fusible plug confirming to relevant of 25 ltrs capacity 3/5 star rated and GI pipe, connection, globe volve, brass ferrule all as fixed and testing all as directed by Engr in charge. Make: Havells/Bajaj/CG
S&F fasteners of size 4/6 inch as per site requirement complete as specified and directed by Engr-in-Charge.
S&F 15mm bore hot & cold type PVC connection of 24 inch length with brass nuts at both end, complete set all as approved & directed.
S&F on walls/roofs/ceilings GI tubing "medium " grade of size 15mm bore including neccesary screwing and all fittings (Tee, union, nipple, reducer, elbow etc) as required at site complete as specified and directed by Engr-in-Charge.
S&F Stop cock brass, ISI marked with screw end for GI tubing of size 15mm complete all as specified and directed.
S & F bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete, all as directed.
Supply, laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable of cross sectional area 10Sqmm, 2 core , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately under BOQ
Supply, errection & installation of steel tubular swaged poles type 410 SP-31 (9.00 metre long) complete with cast iron base plate, finial taper plug, bolts, nuts & screw including 1.2 m long 40mm bore MS GI pipe (light grade) mounting bracket made to shape for street light with and including 2 Nos MS clamp of FI 40x6mm for fixing of bracket complete fix to steel tubular pole with bolts & washers including two coat of aluminium paint over a coat of zinc chrome primer, complete, all as specified & directed.
M&L for PCC 1:4:8, type D-2 using 40mm graded stone aggregates as in foundation of PCC pole/struts including necessary form work, complete, all as specified and directed.
M&L for PCC 1:3:6, type C-2 using 40mm graded stone aggregates as in foundation of stay assembly etc including necessary form work, complete, all as specified and directed.
M&L for PCC 1:2:4, type B-1 using 20mm graded stone aggregates as in coping around pole including necessary form work, finisged even and fair, complete, all as specified and directed.
S&F LED street light fitting of 60 Watt, 230 Volt, AC out door type with high pressure die cast aluminium housing and heat resistant, complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection, complete. Make : Model : Endura cityliner NEO 60 Watt of Havells or equivalent from Bajaj/Philips.
PD GUPTA AND COMPANY
M/S SHIVA TRADERS
M/s SUNIL ENTERPRISES
TRISHUL ENTERPRISES
jmd engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .