Superintending Engineer
EUDC, SRE
work for old vcb installation according to load
2024_PVVNL_896184_2
ET No. 123/W/EUDC/SRE/2023-24
Open Tender
Electrical Works
Lump-sum
21 days
saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Superintending Engineer
₹1,900
Yes
6 Mar 2024
22 Feb 2024
28 Feb 2024
22 Feb 2024
28 Feb 2024
22 Feb 2024
Amount
Proper Opening of 3x300sqmm 11kv cable of incoming No. 1&2 VCBs with Nut, Bolts & locking arrangement for shifting.
Proper Opening of 3x185sqmm 11kv cable of outgoing feeder VCBs with Nut, Bolts & locking arrangement for shifting.
Shifting of 3x300sqmm 11KV I/C cable after pullingout of cable for shifting in old control room so as to have proper arrangement.
Shifting of 3x185sqmm 11KV O/G cable after pullingout of cable for shifting in old control room so as to have proper arrangement.
Cleaning of all existing VCB's in old control room alongwith mechanical re-arrangement to rectify issue of trolly rail bar and setup.
Fixing and making the connection of incoming and outgoing cable in the incoming/outgoing VCB panels including tapping properly alongwith Nut, bolts & locking mechanism.
Shifting other equipment of I/C-I, I/C-2 including installattion properly in new location.
Re-wiring & Cardboard arrangement and lighting arrangement in control room jain Bagh-I including cost of material and labour to be provided by contractors.
Earthing of incoming VCB pannels I/C No. 1 & 2 by boaring 60' deep with providing of 1.5" dia G.I. pipe of class 'B' and connected with M.S. strip of size 50x6mm & providing of required charcoal & salt including connecting with G.I. pipe.
Filling of sand upto proper depth in existing trench of old existing substation control room as per resspo norms.
Retrofitting of damaged earthing strips used for connecting earthing Pt. of panel to earthing point where new strip to be provided by the contractor.
GYAS PAL CONTRACTOR
M/s Raj Kishor Contractor
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .