Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
12 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
GSU
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets & Annual Tax statement duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender.
Definition of similar work: "Satisfactory execution of any electrical work related to HT/LT installation.
44 conditions · 11 needing a document upload
Please submit bank details of the firm / individual/ JV / partnership etc. i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, PAN Number, Aadhar number and other necessary & relevant documents.
Please furnish documents in support of your claim to fulfill the eligibility criteria as mentioned in the tender documents. Each page of the copy of documents / certificates in support of credentials, submitted by the you, shall be self attested / digitally signed by the you or authorized representative of the your firm. Only those documents which are declared explicitly by you as "documents supporting the claim of qualifying the laid down eligibility criteria",will be considered for evaluating the offer or otherwise available in the offer
Please furnish statement of deviations from tender conditions, if any.
Requisite documents proving technical eligibility criteria and financial eligibility criteria has been uploaded along with those required as per explanation given in clause 10 of IRGCC-2022 (Works Matter)
All requisite valid documents regarding constitution of business of the bidding firm should be submitted along with the tender as per clause 14 of IRGCC 2022 (Works Matter),otherwise their offer will be considered incomplete and shall not be considered.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate. Reference: para 15 of IRGCC-2022 (Works matter),otherwise their offer will be considered incomplete and shall not be considered.
Partnership firms, if bidding for the instant tender, should submit all valid requisite documents and fulfill the stipulations as per clause 18 of IRGCC-2022 (Works Matter),otherwise their offer will be considered incomplete and shall not be considered.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are advised to visit the site of work to ascertain all aspects of the site conditions viz accessibility, availability of approach road, nature of the soil, availability of material, availability of labour etc. that may be encounteredin course of execution of work.
Tenderer should see the website for the corrigendum/addendum to the NIT/tender document, if any that may be uploaded prior to tender opening(inclusive) as there will not be any separate communication for that.
The tenderer for carrying any construction work in Uttar Pradesh mustgetthemselves registered from the registering Officer under Section - 7 oftheBuilding and Other Construction Workers Act, 1996 and rules made theretoby the Uttar Pradesh Govt. and submit certificate of Registration(LabourDepartment). For enactment of this Act, the tenderer shall be requiredto paycess @ 1% of cost of construction work to be deducted from each bill
The contractor(s) shall observe all the formalities, perform all the actsandabide by all the provisions contained in the Contract Labour Act-1970andContract Labour Central Rules, 1971 which in addition to otherstipulationsprovides that the contractor(s) shall obtain license(s) from appropriatelicensing officer of thearea before commencement of the work and shall produce a copy thereof along with the original to the Railway office, which will be returned to the contractorafter verification
If any complaint is received against the contractor regarding violationofcontract laws, (exposing Principal Employer to the risk of legalproceedingsunder labour laws), the guilty contractor will be black listed andtheir contract shall be terminated following the due procedure, apart frominitiating criminal proceedings against him with the help of Labour departmentofficials. (Authority: RB letter no.2008/E (LI)/AT/CNR/3, dated 24.01.2018).
The tenderer has to submit necessary documents in compliance of clause 10to 18 (Part-I) of IRGCC 2022 (Works matter) mandatorily, otherwise offer willbe considered as Incomplete Offer and accordingly shall not be considered
It is the responsibility of the tenderer to see corrigendum, if any, totender notice up to the date of tender opening. IRGCC 2022 (works matter) isforreference only. Any correction issued by competent authority up to dateofopening will be applicable. Tenderer should quote accordingly
Railways reserves the right to accept or reject any or all the tenders and toaward the work in whole or in part without assigning the reason for any such action.
It is to be noted that tenderer digital signature on the E-Tender form will be considered as confirmation that tenderer have read and accepted all the conditions laid down in the documents as well as related specification of items, schedule & quantity of items in the tender, consisting of techno commercial offer form (including special conditions attached to ETender) and Financial offer form, unless specific deviation is quoted in the techno- commercial offer form.
The quantities shown in the attached Schedule are given as a guide andareapproximate only and are as a guide to give the tenderer(s) an ideaofquantum of work involved. Quantities are subject to variation according totheneeds of the Railway. The Railway does not guarantee work under eachitemof the Schedule. The Railway reserves the right to increase/ decreaseand/ordelete or include any of the quantities given above and no extra rate will be allowed on this account.
In case of any information submitted by tenderer is found to be false forgedorincorrect at any time during process for evaluation of tenders, it shall leadtoforfeiture of the tender Earnest Money Deposit besides banning of business for a period of upto five years. In case of any information submitted by tenderer is found to be false forged or incorrect after the award of contract,the contract shall be terminated. Bid Security, Performance Guarantee andSecurity Deposit available with the railway shall be for feited. In addition, otherdues of the contractor, if any, under this contract shall beforfeited and agency shall be banned for doing business for a period of up to five years.
Opening of e-tender online:- The e-tenders will be opened online using the IREPS portal. No representative is required to be present for opening of tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders in the website after the opening of the tender.
In case the date of closing mentioned in the Notice Inviting Tender is declared a holiday/bandh/strike etc. on any account, the date of closing tender online will not be changed as the application in the website of IREPS does not permit submission of any offer after closing date and time of the tender. However, opening of tenders online will be on any convenient day after the closing date/time of tenders.
All the bidders / tenderers should ensure that they are GST compliant and their quoted tax structure / rates are as per GST Law ( Ref - Railway Board letter No.2008/RS(G)/777/1 Dated - 29/5/2017 )
The Bid Security shall be deposited either in cash through e- payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids. iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to Dy.CEE/GSU/PRYJ, Office of the CAO/C/RSP, G+5 Building Leader Road, Prayagraj. viii. Ifthe envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
"Electrical work in connection with "Development of GMC as Satellite station in Prayagraj division"
GSU-EL-WC-74-2026
GSU-EL-WC-74-2026
Open
Works - General
12 Months
Prayagraj, Uttar Pradesh
₹0
₹2.2 L
12 Aug 2026
21 Jul 2026
29 Jul 2026
60 items across 1 schedule · ₹1,11,94,638.89 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(B) | Numbers | 1500.00 | 1,362 | 20,43,000 |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. | Metre | 1200.00 | 311 | 3,73,200 |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire. | Metre | 700.00 | 452 | 3,16,400 |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire. | Metre | 600.00 | 373 | 2,23,800 |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 X 4 sq. mm + 2 X 4 sq. mm earth wire. | Metre | 500.00 | 744 | 3,72,000 |
| 6 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 10 sq. mm + 2 X 6 sq. mm earth wire. | Metre | 500.00 | 621 | 3,10,500 |
| 7 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm) | Each | 150.00 | 401 | 60,150 |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | Each | 50.00 | 402 | 20,100 |
| 9 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | Each | 150.00 | 47 | 7,050 |
| 10 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | Each | 200.00 | 104 | 20,800 |
| 11 | Supply and commissioning of JUNCTION (1Number= 1 Packet). with ISI Mark | Numbers | 100.00 | 173.15 | 17,315 |
| 12 | Supply and commissioning of BEND (1 Number= 1Packet). with ISI Mark. | Numbers | 150.00 | 227.83 | 34,174.5 |
| 13 | Supply and commissioning of socket 3 pin 5/6 A socket outlet with ISI Mark. | Each | 250.00 | 136 | 34,000 |
| 14 | Supply and commissioning of Switch 5/6 A switch with ISI Mark. | Each | 250.00 | 121 | 30,250 |
| 15 | Supply and commissioning of socket 6 pin 15/16 A socket outlet with ISI Mark. | Each | 250.00 | 219 | 54,750 |
| 16 | Supply and commissioning of Switch 16A with ISI Mark. | Numbers | 250.00 | 176 | 44,000 |
| 17 | Supplying and laying of following size DWC/HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) | Metre | 600.00 | 264 | 1,58,400 |
| 18 | Termination of LT XLPE cables of various sizes (One Job means all 4 cores of cables). | Numbers | 100.00 | 134.35 | 13,435 |
| 19 | Collecting, Transporting from SSE/GSU/store to site, laying, testing, and commissioning of above LT cable . Laying direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/required in wall/in concrete floor by cutting recessed and finished originally as required as per relevant technical specifications. | Metre | 8500.00 | 73.41 | 6,23,985 |
| 20 | Drilling of bituminous road/track and laying charges of cable in road crossing for laying 110 mm diaHDPE pipe through it. | Metre | 2000.00 | 315.68 | 6,31,360 |
| 21 | Supply and laying of B class, 50 mm dia, GI pipe for cable riser/road crossing as required and as per relevant technical specification. | Metre | 200.00 | 139.42 | 27,884 |
| 22 | Supply and burying of earth electrode of 40mm dia 'B' class GI pipe of 3.0 Mtrs long having 12 mm dia holes spaced 75 mm apart drilled upto 2 mtrs length from the bottom including 340 mm wide pit is to be dug upto the depth of not less then 3750mm. The earth electrod lowered in the pit thereafter refilling of pit is to be done with 30mm alternate layer of salt and charcoal upto 2.5 Mtrs. Pit is to be made of not less than 40 x 40 x 30 Cms from inside & precast RCC cover of 40mm thick with lifting arrangement shall confirm to CEE/NR specification No. NR/Elect/Wiring/1-84 and Drg. No. Sr. DEE/G/ALD 10/94. GI pipe shall be of TATA/QST/JINDAL make. | Numbers | 30.00 | 939.22 | 28,176.6 |
| 23 | Supply, fixing, testing, connecting and commissioning of feeder pillar with 01 no. 250A 04 pole MCCB for incoming & 25 nos s.p. 63A MCB for outgoing as per relevant specification. | Numbers | 2.00 | 19,800.78 | 39,601.56 |
| 24 | Supply, erection, testing and commissioning of approved make standard size of following Distribution board recessed in wall having earth terminal block and neutral terminal block to enable termination of conductors incoming as well as outgoing individually by screwed connections and without twisting complete in all respect as per relevant technical specification.DP distribution board of standard size confirming to technical specification No. Sr.DEE/G/ALD/94/104 comprising of one No. 2 pole 32/40 Amps MCB's of approved make.(1) 4-No SP MCB's of 6 Amps as required. | Numbers | 20.00 | 921.96 | 18,439.2 |
| 25 | Supply, erection, testing and commissioning of approved make standard size of following Distribution board recessed in wall having earth terminal block and neutral terminal block to enable termination of conductors incoming as well as outgoing individually by screwed connections and without twisting complete in all respect as per relevant technical specification of DP distribution board of standard size confirming to technical specification No. Sr.DEE/G/ALD/94/104 comprising of one No. 2 pole 32/40 Amps MCB's & 8-No SP MCB's of 6/10 Amps as required. | Numbers | 20.00 | 1,941.11 | 38,822.2 |
| 26 | Supply, replacement, fixing, testing, connecting and commissioning of 72 Watt or above LED street lights fittings.LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute lights,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.Type LED:- High power LED,SMD(Surface Mounting device)/COB(Clip on board).1.Input operating voltage :-105-295 V AC.2:- Normal Voltage-220V AC,3.Driver type: constant current driver with short circuit protection. 4.LED life:- >50000 burning hours.5.Depreciation:- 30% max.after 50000 burning hours.6.Control of distribution:-Full cut off. 7.Surge protection:4KV.8.Drive component :Industrial grade only.9.Efficiency of driver electronic: > 85%.10.Beam angle:>=140 degree along with road and >=80 degree across the road.11.Colour temperature:5000- 6500K.12.Colour rendering index(CRI):>=75.13.Ingress protection :IP- 66.14.Lumen output: >120 lumens/watt.15.Power factor:->0.95. 16.Total harmonics distortion(THD):-<15%.17.Lamp cover :Toughened glass or UV stabilised poly carbonate.18.Finishing:Power coated /Anodized.19.Secondry optics:poly carbonate reflector/ poly carbonates lens.20.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.21.Mounting:Suitable for existing pole/Truss/Lantern mounted.22.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminare used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.23.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted with new suitable bend/elbow with clamp and proper nut and bolt and connection with twisted twin flexible cord of minimum size 16/1 mm copper conductor as per relevant technical specification. Materials parameters must remain unchanged during entire warranty period. | Numbers | 50.00 | 2,478.59 | 1,23,929.5 |
| 27 | Supply, replacement, fixing, testing, connecting and commissioning of energy efficient luminaries complete with all accessories of capacity 20 watt, 4 feet length, T8 LED lamps with suitable current control driver circuit ,suitable for surface/recessed mounting.LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute light,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/Jaquar/ PHILIPS/LUMILEDS /LEDNIUM. (2):- LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.1.Input operating voltage :-105-295 V AC.2:-Normal Voltage-220V AC.3.Driver type: constant current driver with short circuit protection(For tube light).4.Control of distribution:-Full cut off.5.Drive component :Industrial grade only .6.Efficiency of driver electronic: > 85% (For tube light).7.Colour temperature:5000-6500K(For tube light).8.Colour rendering index(CRI):>75(For tube light).9.Ingress protection :IP-20.10.Lumen output: >100 lumens/[email protected] drive current(For tube light).11.Power factor:->0.90(For tube light). 12.Total harmonics distortion(THD):- <20%(For tube light).13.Lamp cover :Acrylic cover which does not result in loss of lumens.14.Finishing:Power coated /Anodized.15.Secondry optics:poly carbonate reflector/ poly carbonate lens.16.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.17.Mounting :Suitable for surface mounting/recessed mounting.18.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminaire used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.19.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted as surface mounting/recessed mounting with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor as per relevant technical specification. Materials parameters must remain unchanged during entire warranty period.....1x20watt. | Numbers | 400.00 | 360.1 | 1,44,040 |
| 28 | Supply, fixing, testing, connecting and commissioning of 24/36 watt 2x2 LED lights fittings, recess LED Fitting 24/36 watt ,suitable for surface/recessed mounting. LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute light,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:- (1):- NICHIA/CREE/OSRAM/SEOUL/ PHILIPS/LUMILEDS/LEDNIUM. (2):-LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.1.Input operating voltage :-105-295 V AC.2:-Normal Voltage-220V AC.3.Driver type: constant current driver with short circuit protection. 4.Control of distribution:-Full cut off. 5. Lumens-3600/5400 .6.Efficiency of driver electronic: > 85% .7.Colour temperature:4000K.8.Colour rendering index(CRI):>75. 9.Ingress protection :IP- 20.10.Lumen output: >150 lumens/[email protected] drive current. 11.Power factor:->0.97. 12.Total harmonics distortion(THD):-<20%. 13.Lamp cover :Acrylic cover which does not result in loss of lumens. 14.Finishing:Power coated /Anodized.15.Secondry optics:poly carbonate reflector/ poly carbonate lens.16.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.17.Mounting :Suitable for surface mounting/recessed mounting.18.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminaire used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.19.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted as surface mounting/recessed mounting with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor as per relevant technical specification. Materials parameters must remain unchanged during entire warranty period. | Numbers | 20.00 | 2,077.49 | 41,549.8 |
| 29 | Supply, fixing, testing, connecting and commissioning of storage type water cooler similar to Model SDLX 100, Cooling Capacity-170 litre per hour, 380 litre Storage with suitable foundation/platform with cage. | Numbers | 2.00 | 69,813.13 | 1,39,626.26 |
| 30 | Supply, fixing & commissioning of LT Heat Shrinkable Straight through jointing Kit for 3.5/4 Core 50-95 Sqmm LT XLPE Cable. | Numbers | 10.00 | 1,519.05 | 15,190.5 |
| 31 | Supply, fixing & commissioning of LT Heat Shrinkable Straight through jointing Kit for 3.5/4 Core 120-185 Sqmm LT XLPE Cable. | Numbers | 10.00 | 2,087.28 | 20,872.8 |
| 32 | Supply, fixing, connecting and commissioning of Push Button-Industrial type Plug & socket SPN distribution board with 02 pole & earth metal Plug & socket complete with 32A S.P. MCB. | Numbers | 10.00 | 904.59 | 9,045.9 |
| 33 | Supply, fixing, connecting and commissioning of PVC drain pipe of size 3/4'. | Metre | 100.00 | 28.93 | 2,893 |
| 34 | Supply, fixing, testing, connecting and commissioning of 300 mm sweep Exhaust Fan suitable for 230 volts, 50 Hz AC supply, more than1400 RPM heavy duty with wiring and flexible PVC pipe as required. Make: Bajaj, Havell's, RR or similar. | Numbers | 6.00 | 1,603.39 | 9,620.34 |
| 35 | Supply, fixing, testing, connecting and commissioning of 750 mm heavy duty wall mounted air circulator Fan suitable for 230 volts, 50Hz - AC supply, 1440 RPM, with wiring in flexible PVC pipe as required. | Numbers | 8.00 | 7,909.99 | 63,279.92 |
| 36 | Supply, fixing, connecting and commissioning of 5 KVA Single Phase, Sine wave Digital Voltage Stabilizer as per IS:8448 or latest amendment up to date, input voltage 160-260 Volt, output voltage 230 +10% Volt with time delay relay.Make-Blue star or similar. | Numbers | 4.00 | 8,195.41 | 32,781.64 |
| 37 | Design,Supply, erection, testing and commissioning of LT Switch gear panel board of 2mm thick dia pressed CRC steel sheet . Panel shall be treated for anti corrosion treatment and finished with smoke gray paint as per technical specification No. Sr DEE/G/ALD/ Panel-94/113 comprising with.........Supply of Incoming ACB 630A,04 Pole draw-out 50 Hz.Coforming IS:13947-2 of make. | Numbers | 1.00 | 1,27,579.08 | 1,27,579.08 |
| 38 | Supply, fixing, testing, connecting and commissioning of of Bus Coupler ACB 630 A,04 Pole draw out,50Hz,Conforming IS:13947-3 Make- ABB/L &T/Crompton Greaves | Numbers | 1.00 | 1,27,579.08 | 1,27,579.08 |
| 39 | Supply, fixing, testing, connecting and commissioning of ACB 630 A, 415 Volt, 3 phase, 4 pole Manually draw out microproceeor basd type conforming to IS: 13947-2, IEC 60947-2 latest specification. | Numbers | 1.00 | 1,34,733.62 | 1,34,733.62 |
| 40 | Supply, fixing, testing, connecting and commissioning of MCCB of 250 A, 36 kA Standard breaking capacity, 415 volt, 3 Phase 4 Pole current rating 250 Amp. | Numbers | 5.00 | 12,099.05 | 60,495.25 |
| 41 | Supply, fixing, testing, connecting and commissioning of MCCB of 125A, 36 kA Standard breaking capacity, 415 volt, 3 Phase 4 Pole current rating 125 Amp. | Numbers | 5.00 | 7,951.14 | 39,755.7 |
| 42 | Supply, fixing, testing, connecting and commissioning of Indicator lamps with suitable holder. | Numbers | 39.00 | 98.37 | 3,836.43 |
| 43 | Supply, fixing, testing, connecting and commissioning of Outgoing/Feeder Panel Mounted Multi-function meter with Accuracy Class 1 as perIEC 62053-21 or Class 0.5, 0.5S as per IEC 62053-22.LED meter Cl 1 with RS485: Meter should havefollowing features built-in LED • Flush mounting 96x 96 mm • True RMS measurement • Passwordprotection provision for security • Site selectable for3 Phase 4 wire, 3 Phase 3 wire, 1 Phase, CT Secondary 1A/5A, Universal Auxiliary Supply 80-300VAC/DC, Input Voltage Measurement 50-500 VAC, •64 samples/ cycle The Meter should be able toread/display following parameters InstantaneousParameters (V1, V2, V3, V12, V23, V31, Avg (VLN,VLL), A1, A2, A3, Aavg, F, PF-1, PF-2, PF-3, PF(Avg) W1, W2, W3, W (total) VA1, VA2, VA3, VA(total) Cumulative Parameters (Import Wh, ImportVah, Import load hours, Reset (old) Cumulativeparameters (Import Wh, Import load hours,Communication (RS485 Modus RTU).complete withall accessories. | Numbers | 13.00 | 2,963.26 | 38,522.38 |
| 44 | Supply, fixing, testing, connecting and commissioning of Fabrication works and insulated Aluminum bus bars of 1200A capacity for phases & 1200A capacity for neutral Bus bar shall be suitably insulated with heat shrinkable sleeves/ epoxy coating/insulating tap to withstand the test voltage of 2.5 KV Copper strip for connection outgoing as well as incoming with suitable size be provided. | Numbers | 1.00 | 62,819.27 | 62,819.27 |
| 45 | Supply and erection of 6 Mtr.Galvanised (as per BS EN ISO 1461) octagonal pole with base plate 220x220x12mm, top 70mm and bottom 130 mm of 3mm thick sheet suitable for maximum wind speed utp 160 Km/Hr. including foundation bolts and foundation with M 20 grade RCC and FE 415 grade reinforcement (450x450x800 Cm deep ) (foundaton should be as per design approved by pole monufacturer) GI base plate G.I. anchor plate etc.as required including supplying and fxing of 1 Mtr.long double arm hot depped galvanised bracket suitable for street light fittings and supplying and drawing of 3x2.5Sq.mm FRLS copper conductor single core cable from junction box with two Nos 6/10AMP MCB to luminaire complete including termination with copper lugs as required. Confirming to IS:2062,IS:875 Part-3 & IS:4759 | Numbers | 25.00 | 14,732.87 | 3,68,321.75 |
| 46 | Design, Survey, Proposal with Technical Elevation Drawings & 3D layout, Supply, Manufacture, Erection, Installation, testing and Display of wall / hanging / floor /pole mounting type LED illuminated, Modular, Changeable Aluminium extruded profile signage / direction board in full/half Parabolic and Elliptical square and multiangle shape and flat, with die molded internal structural brackets (Nylon/SS) and aluminium extruded heat sink. Suitable size end cap PC/ SS304 should be provided with provision of illuminated Logo. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2-3 mm thickness. The text / graphics matter vision angle shall not be less than 160 degree and visibility not be less than 75%.The approved color text and graphics shall be printed / router cut on monomeric calendered vinyl of 100 um thickness and shall be firmly pasted on display sheets. A pole with grooves for tricolor LED/Neon light installation. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the backside of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4- 8 W / sq. ft and with brightness more than ambient light. It shall confirm the latest specification issued by railway board (also uploaded). | Square Foot | 120.00 | 2,197.63 | 2,63,715.6 |
| 47 | Supply of Auto change Over panel for CLS 25KVA 150A capacity as per RDSO specification no. TI/SPC/PSI/CLS/0023 | Numbers | 2.00 | 1,26,892.02 | 2,53,784.04 |
| 48 | Erection ,Testing commissioning of Auto change Over pannel for CLS 25KVA 150A capacity as per RDSO specification no.TI/SPC/PSI/CLS/0023 | Numbers | 2.00 | 5,612.9 | 11,225.8 |
| 49 | Supply, fixing, testing, connecting and commissioning of I- Phase 5 KVA, 120 volt DC input UPS of Microteck or similar make with battery bank of 12 V, 10 Nos Tubular batteries of OKAYA of similar make each of 150AH for emergency supply. | Numbers | 2.00 | 1,35,272.43 | 2,70,544.86 |
| 50 | Design, fabrication, supply and fixing of GI perforated horizontal cable- tray with all connected accessories viz- bend, tree, cross, reducer, 45 ° horizontal bend, coupler plates etc.including painting besides clamping, shifting of existing cables into the trenches along with tagging and labling of shifted cables with numbering sleeves fot easy identification. size 300 mm width , 100 mm depth, 2 mm thickness. | Metre | 500.00 | 1,157.72 | 5,78,860 |
| 51 | Supply, fixing, testing, connecting and commissioning of 1200mm sweep BEE 5 Star rated ceiling fan with Brushless Direct current (BLDC) Motor,Class of Insulation B,03 no Blade,30 Centimeter long down Rod 02 No Canopiess,Shackle kit,Safety Rope,Copper winding power factor not less than 0.9 ,Service value (CM/M/W)Minimum 6.00 Air delivery minimum 210 Cum/Min,350 RPM(Tolerance as per IS:374-2019) THD Less than 10 % remote or Electronic regulator unit for speed control & all remaining accessories including Safety fin,Nut Bolts,Washers,temperature rise=75 degree C Maximum,Insulation Resistance more than 2 Mega ohm suitable for 230 volts,50 HZ,Single phase,AC Supply,Earthing with suitable fan hook etc,complete as required. | Numbers | 70.00 | 2,537.35 | 1,77,614.5 |
| 52 | Supply, Erection testing, connecting and commissioning of maintenance free Earthing RDSO spec no.RDSO/SPN/197/2008 or Latest consisting of. Earth electrode of copper bonded high tensile low carbon steel rods, specially designed for electrical grounding as per RDSO Spec. No RDSO/SPN/197/2008 or latest. RDSO approved earth enhancing compound in 10 Kg pack - 05 No. Copper tape of 25mm x 6mm x 300mm with 99.9% purity - 2 Nos and another of 25mm x 6mm x 150mm to terminate on earth electrode Supply of insulated connecting cable as per RDSO Spec No RDSO/SPN/197/2008 or latest to connect equipment bus bar 10 meter each earth Installation of Unit Earth consisting materials covered in item 1 in accordance to RDSO Spec No RDSO/SPN/197/2008 or latest Digging of earth to the required depth Insertion of electrodes - 1 Nos Filling of earth enhancing compound, provision of exothermic weld connection on copper tape of 25mmx 6mmx 150mm to the earth electrodes. (All materials tools and fixtures required for the weld to be arranged by the contractor) -5No. 25mm x 6mm x 150mm to the earth electrodes (All materials tools and fixtures required for the weld to be arranged by the contractor)- 1 No. Provision of exothermic weld connection on copper tape of 25mm x 6mm x 150mm to the earth electrodes (All materials tools and fixtures required for the weld to be arranged by the contractor) - 1 No. Provision of exothermic weld one to connecting cable to the earth electrodes and another to the copper tape to be fixed inside the Equipment/Relay rack/apparatus room (features for mounting the copper tape inside the relay room, weld materials, tool, fixtures and other materials required for the weld shall be arranged by the contractor). | Numbers | 5.00 | 13,210.76 | 66,053.8 |
| 53 | Supply, fixing, testing, connecting and commissioning of wall mounted Bracket Fan 750 MM including heavy duty associated works as per relevant technical specification. Make-Bajaj ,Havells etc. | Numbers | 5.00 | 1,712.15 | 8,560.75 |
| 54 | Supply,fixing,testing,connecting and commissioning of LED Type 12 watt LED Surface panel round spot light,suitable for 230 Volts,50 Hz AC supply with wiring and flexible PVC pipe as requires Make-Havells, orient or ISI Marked. | Numbers | 150.00 | 1,343.65 | 2,01,547.5 |
| 55 | Supply, erection, testing, connecting & commissioning of 200W LED flood Light fittings as per IS:10322. LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute lights, to position and protect the light source and to connect the light source to a branch circuit. The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:-(1):-NICHIA/CREE /OSRAM/SEOUL/ PHILIPS/LUMILEDS /LEDNIUM (2):- LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.Type LED:- High power LED,SMD(Surface Mounting device) /COB(Clip on board).1.Input operating voltage :-105-295 V AC.2:- Normal Voltage-220V AC,3.Driver type: constant current driver with short circuit protection. 4.LED life:- >=50000 burning hours.5.Depreciation:- 30% max.after 50000 burning hours.6.Control of distribution:-Full cut off. 7.Surge protection:4KV.8.Drive component :Industrial grade only.9.Efficiency of driver electronic: >= 85%.10.Beam angle:>=140 degree along with road and >=80 degree across the road.11.Colour temperature:5000- 6500K.12.Colour rendering index( CRI ): >=75 . 13. Ingress protection:IP- 66.14.Lumen output: >=120 lumens/watt.15.Power factor:- >=0.95.16.Total hormonics distrotion(THD):- <15%.17.Lamp cover: Toughened glass or UV stabilsed poly carbonate.18.Finishing:Power coated /Anodized.19.Secondry optics:poly carbonate reflector/ polycarbonates lens.20.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.21.Mounting:Suitable for existing pole/Truss/Lantern mounted.22.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminare used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.23.Warranty:Firm to submit warranty certificate for five year along with the supply. All fittings shall be fitted with new suitable bend/elbow with clamp and proper nut and bolt and connection with twisted twin flexible cord of minimum size 16/1 mm copper conductor as per r e l e v a n t technical specification. Material parameters must remain unchanged during entire warranty period. | Numbers | 16.00 | 7,864.27 | 1,25,828.32 |
| 56 | Shifting work of HT/LT Panels/ Transformers /DG set, Reinstallation, commissioning & testing of all (foundation not included) with provision of tripping arrangement through control circuit | Job | 2.00 | 24,919.85 | 49,839.7 |
| 57 | LT fault location charge with transportation charges | Job | 4.00 | 7,028.65 | 28,114.6 |
| 58 | Supply, installation, testing, connecting and commissioning of LED base name board of different stations (01 set includes 01 No Hindi, 01 No English& 01 No Urdu name board) with power LEDs, Drivers & wiring of board. The signage board should have alphabet of vertical peak height of 600 mm and proportionate horizontal span. Approximate size of Hindi, English signage panel shall have Length-6400 mm, Height- 912 mm Detailed spec. mentioned in tender document. Note -01 set includes a. Hindi board 01 No b. English board 01No c. Urdu board 01 No. | Set | 1.00 | 1,80,283.14 | 1,80,283.14 |
| 59 | Excavation of cable trench in soft morrum plain ground concrete/pucca surface etcand back filling of cable for laying of LT cables including placing of bricks incross position etc. | Metre | 700.00 | 86.27 | 60,389 |
| 60 | Excavation of cable duct by horizontal boring method 2.5 to 4.0 mtr depths from the bottom of sleeper for trench less track crossing and laying of120 mm outer dia. DWC pipe. The work shall be done as per extent practice and instruction of site engineer. It includes supply of DWC/HDPE pipes conforming to IS : 14930 (Part 2, 2001).( Rex Poly Extrusion or similar make. Mouling shall be carried out in the presence of Representative of Dy.CEE/GSU/PRYJ. In this regards written information shall be submitted before two days of execution. | Metre | 1200.00 | 1,508.51 | 18,10,212 |
| Schedule total | ₹1,11,94,638.89 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022
ATTACHMENT
LatestANNEXUREVVA.pdf
ATTACHMENT
Ann-VIBforFinanacialcriteria.pdf
ATTACHMENT
ACS01to11_1.pdf
ATTACHMENT
SIGNAGEEXPLANATORY.pdf
ATTACHMENT
Signageguidelines_PRYJ.pdf
ATTACHMENT
TENDERDOCUMENTGMC.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .