| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAdmitted-Finance | ₹5.5 L | L1 | Admitted-Finance |
| 2 | L2₹5.7 L+₹22,500 (4.10%)Admitted-Finance LEH | LEH LADAKH | LADAKH | 194001 | ₹5.7 L+₹22,500 (4.10%) | L2 | Admitted-Finance |
| 3 | L3₹6.5 L+₹99,000 (18.0%)Admitted-Finance | ₹6.5 L+₹99,000 (18.0%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S MUZAMIL MASOOD L2 | M/S SILK ROUTE ENERGY PRIVATE LIMITED L1 | M/S ZUBAIR AHMED L3 |
|---|---|---|---|---|---|---|
| 1.00DT (Supply Part) | ||||||
| 1.01 | 25KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, and with LV Cable Box having detachable Aluminium Gland plate | 1 | No | 1,40,000 ₹1,40,000 | 1,20,000 ₹1,20,000 Lowest | 1,60,000 ₹1,60,000 |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 1 | Set | 9,000 ₹9,000 | 8,000 ₹8,000 Lowest | 9,500 ₹9,500 |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type | 1 | Set | 8,000 ₹8,000 | 7,000 ₹7,000 Lowest | 10,000 ₹10,000 |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | 3,100 ₹3,100 | 3,000 ₹3,000 Lowest | 3,500 ₹3,500 |
| 1.05 | 35mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type | 44 | Mtr | 350 ₹15,400 Lowest | 400 ₹17,600 | 450 ₹19,800 |
| 1.06 | 9 Mtr. Long Pole,ST-410 SP33) | 2 | Nos | 16,000 ₹32,000 Lowest | 17,000 ₹34,000 | 20,000 ₹40,000 |
| 1.07 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm | 3 | Nos | 1,200 ₹3,600 Lowest | 1,200 ₹3,600 Lowest | 1,400 ₹4,200 |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 250 | Kgs | 200 ₹50,000 | 180 ₹45,000 Lowest | 300 ₹75,000 |
| 1.09 | Galvinized Nuts and Bolts. | 8 | Kgs | 150 ₹1,200 Lowest | 200 ₹1,600 | 200 ₹1,600 |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
6 Aug 2025, 2:00 pmClosed
Executive Engineer
PDD Chglamsar
same as above
2025_PDNRE_17030_1
e-NIT No. 86 of ED Leh of 2025-26 dated 29-07-2025
Open Tender
Electrical Works
Turn-key
30 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹300
Payable To Executive Engineer
₹11,000
12 Aug 2025
29 Jul 2025
7 Aug 2025
29 Jul 2025
6 Aug 2025
30 Jul 2025
Amount
DT (Supply Part)
25KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
35mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
32Amp TPN Switch Disconnector Fuse Unit
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3Phase 4wire Trivector Meter with CT(LTCT AMR Compatible)
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper binding Tape
70Sqmm 3.5Core 1.1KV Grade XLPE Cable for Service Line
DT Installation/Testing/Commissioning Part)
25KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
35mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
32Amp TPN Switch Disconnector Fuse Unit
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3Phase 4wire Trivector Meter with CT(LTCT AMR Compatible)
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper binding Tape
70Sqmm 3.5Core 1.1KV Grade XLPE Cable for Service Line
HT Line (Supply Part)
9 Mtr. Long Pole,ST-410 SP33)
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Aluminium Jointing Sleeves
HT Line (Installation/Testing/Commissioning Part)
9 Mtr. Long Pole,ST-410 SP33)
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Aluminium Jointing Sleeves
M/S MUZAMIL MASOOD (BID ID -166356)
M/S ZUBAIR AHMED (BID ID -166352)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .