Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC DARAULI HOUSE NO 119 DARAULI 123411 | REWARI | HARYANA | 123411 | L1 | Accepted-AOC ok | |
| 2 | L2₹2.0 L+₹3,289 (1.67%)Rejected-AOC H NO 399 VPO LILODH TEHSIL KOSLI 123303 | KOSLI | REWARI | HARYANA | 123303 | L2 | Rejected-AOC ok |
Tender Value
₹2.0 L
EMD Value
₹3,965
Closing Date
27 Jan 2026, 5:00 pmClosed
Amit Rathi
DIV Rewari
Annual maintenance estimate of Water Supply, Sewerage Scheme in Sector-6, Dharuhera for the year 2025-2026
2026_HBC_498034_1
2026C40ED67D FF0B 4D25 BE65 D95C6F88048F258HSV
Open Tender
Civil Works
Works
30 days
Dharuhera
2 documents required · 2 mandatory
₹295
₹3,965
Yes
30 Jan 2026
20 Jan 2026
28 Jan 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
NS Item -Rectifying water leakage on running lines CI/DI/AC of size 250/300 mm with cost of mat
NS Item -Rectifying water leakage on running lines CI/DI/AC of size 100/150/200 mm with cost of material and Labour complete in all respect.
14.51.2-Hire charges for Hydraulic excavator/Loader like JCB/Pock lain, Hitachi etc with all accessories having bucket capacity 2. Hire Charges for excavator 0.40 to 0.75 cum bucket capacity
NS Item -Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (D) ISI marked K-9 grade SandS pipes as per 15:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS:1985 (excuding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/W to be measured I and paid separately. 100mm i/d
20.59.2-Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 2. 100mm i/d CID Joint
20.59.3-Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, 14unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 3. 150mm i/d CID Joint
20.59.4-Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 4. 200mm i/d CID Joint
20.59.5-Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 5. 250mm i/d CID Joint
20.59.6-Providing and fixing Cast Iron Detachable Joints class-25 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 6. 300mm i/d CID Joint
20.49.1-Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made. 1. Up to 200 mm internal diametre
20.49.2-Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made. 2. Exceeding 200 mm internal diametre but not exceeding 300 mm internal diametre
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_576589.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .