Loading…
Loading…
Tender Value
Refer Docs
Closing Date
9 Oct 2024, 5:00 pmClosed
Narad Muni Gupta
Irugur TOP Installation, Bharat Petroleum Corporation Limited
SUBJECT: “ Supplying of Non-Ex Proof & Ex Proof Bullet Camera, PTZ Camera, Installation, Erection, Commissioning & Integration of these Camera with Existing CCTV Network in LPG Plant, Coimbatore” CRFQ NO: 1000423860 SYSTEM ID: 17908 09.10.2024 due on @17:00 hrs 1. You are invited to submit your offer as E-bids in two-part for the above work on the terms and conditions contained in this tender document. 2. 1. This tender document consists of the following annexure, which are enclosed: a. General conditions of contract b. Special condition of Contract c. Scope of work d. Tender Work Sheet (BOQ) e. &nb . For clarifications, if any, please feel free to contact the undersigned: Please visit the website https://bpcltenders.eproc.in/ for participating in this tender process and submitting your bid online. 5. Your online bid should be submitted on or before the due date of this tender. 6. E-tender system will automatically close on the due date and time and bidders will not be able to submit their bids after the closing time. Bids not in the prescribed format are liable to be rejected. BPCL does not take any responsibility for any delay in submission of online bids due to connectivity problem or non-availability of site and/or other documents/instruments to be submitted in physical form due to postal delay. No claims on this account shall be entertained. 7. Bidders are requested to read carefully full scope, work Specifications and tender terms and conditions and understand and make site and participate. Pre-bid meeting will be 27-09-2024 at BPCL Irugur Installation at 15:00hrs . please present without fail. 8. Bidders are requested to upload BPCL registration certificate/ MSME certificate for exempted from EMD deposit. A successful bidder must submit retention or security deposit/ bank guaranty as per tender value as BPCL policy
17908
1000423860
Limited Tender
Works
Irugur TOP Installation
14 Oct 2024
25 Sept 2024
10 Oct 2024
25 Sept 2024
9 Oct 2024
25 Sept 2024
25 Sept 2024 - 9 Oct 2024
PROVIDING CCTV SURVEILANCE IN COMPLIACE OF T4S AUDIT WORKS AT BPCL BLACK OIL DEPOT, PEELAMEDU
Bid document working sheet
SL NO: | SERVICE CODE | SHORT DESCRIPTION | Service Text | UOM | QUANTITY | UNIT RATE IN RS. | TOTAL COST
1 | Non-SOR | IP Camera - Non FLP | 5MP 12X OPTICAL ZOMM 5.2MM ~60MM SIP AND AI BASED 100 MTR IP IR BULLET CAMERA | EA | 1 |
2 | Non-SOR | IP Camera - FLP | 2MP 18X OPTICAL ZOOM EXP PROOF SS 304/316 BULLET CAMERA | EA | 3 |
3 | Non-SOR | IP Camera - PTZ 23X | 5MP 23X OPTICAL ZOOM 16X DIGITAL ZOOM SIP AND AI BASED 150 MTR IR PTZ CAMERA | EA | 1 |
4 | Non-SOR | Hard Disk - 10 TB | Hard Disk - 10 TB | EA | 1 |
5 | Non-SOR | POE Switch | Fully loaded 08 PORT INDUSTRIAL L3 SWITCH POE with GIG FIBER MODULE | EA | 1 |
6 | Non-SOR | Dual Media Optical Coverter | 10/100/1000 Dual Media Optical Coverter | EA | 4 |
7 | Non-SOR | WORK STATION (PC Destop) | I5 WORK STATION (PC) WITH 16 GB RAM WITHOUT MONITOR | EA | 1 |
8 | Non-SOR | Monitor - 43" | LED Monitor - 43" Indutrial | EA | 1 |
9 | Non-SOR | Spike Guard - 4 way | Spike Guard - 4 way | EA | 4 |
10 | Non-SOR | Software | Video Management Software | LS | 1 |
11 | 9020932 | FLP JUNCTION BOX 14" | Supply and installation of Ex-D Gas Group IIA, IIB FLP and WP Junction box: 340 dia multiway Junction box with maximum 18 entries upto 1" ET with maximum entry three on three sides (top entry not to be given). | NOS | 3 |
12 | 9023748 | S/I FLP ET 25MMGLAND | Ex-D Gas Group IIA/B/C FLP glands double compression brass nickel of size 25 Sq mm ET including termination with suitable size of Copper/ Aluminium lugs and Ferrules. | NOS | 24 |
13 | 9019162 | Armoured Cat-6 Cable | Supply, Laying, Errection & commissioing of Armoured Cat-6 Cable | M | 305 |
14 | 9020870 | S/L CAB 2CX2.5MM2 | Cables :Supplying, Laying; Testing and Commissioning Of 1.1 Kv Grade Cables ; Pvc/XLPEinsulated; Pvc Sheathed; FRLS Armoured copper Conductor Cables of Following Sizes As Per Is:1554 (Part-I), IS 7098 Part I & IS 1225-Latest Version and Sealed properly with Pvc Caps In Built-Up Ready Made Trenches; Overhead Cable trays;Pull through Pipes Or Exposed On Wall .Beam/Rakes; Trusses Tie/Beamor Embedded In Floor Or buried Directly Underground (Excavation, sand and bricks shall be paid under seperate item of BOQ) Or Through G. I.Pipe.Unit Rates Quoted For Installationof Cables Shall Be Same Irrespective Of Route and Method Of Laying. The rates Shall Include Laying, Pulling Of Cables, Proper Dressing Of Cables on Cable Trays, Racks, Vertical Raceways and Supply and Installation Of saddles, Spacers and Nylon Chord For Tying As Required,Identification Tags At Strategic Points/ Every 50 Meter Intervales,aluminium Clamps. etc. Cable Identification Tags At Strategic Points/ Every 50 Meter Interval For Identification Of Cable; Etc. Complete.The Straight Through Joints/ tying with armour In The Cables Should Be avoided.
Procedure for laying of LT cables.MAKES/SPECIFICATIONS | RM | 750 |
15 | 9023731 | S/L CAB OFC ARM | Armored OFC Cable-12 Fibers | RM | 750 |
17 | 9019314 | HDPE PIP EXPOSED 40 MM | Supplying, fitting and laying exposed HDPE pipes of heavy class conforming to IS code 4984 with all necessary fittings such as bends, tees, elbows,reducers, unions , nipples, plugs, clamps, fixtures, etc., in masonry /concrete works including necessary painting with two coats of oil paintover a coat of approved primer complete at all leads and lifts as perdrawings, specifications and instructions of the Engineer Incharge. | M | 40 |
18 | 9021025 | GI PERF TRAY 2" | PERFORATED TYPE CABLE TRAYS WITHOUT GI COVER :Supplying and Installation of GI Perforated (50 X 25 X 2 mm) | RM | 180 |
19 | 9019152 | PVC CONDUIT WALL40MM | Supplying and fixing of 40 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | M | 50 |
20 | 9018691 | SFE STR STL MANUAL | Supply, fabrication and erection in position; bolted and/or welded structural steel works at all levels | KG | 200 |
21 | 9021060 | TRENCH EX SAND BK450 | Excavating trench 750 mm deep, 450 mm wide for laying cables, supplying and filling sand 150 mm on top and 150 mm below the cable, minimum 75mm thick Class B brick protection on the top of the cable, back filling the trench after laying cables, earth strips, etc. Finishing the top after consolidation including levelling of surplus soil from the site of ercetion as per direction of Engineer-in-charge. | RM | 60 |
22 | 9018777 | PCC PLIN 1:1.5:3 MS | Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations,drains,fillings, non-suspended floors, pavements & ramps or any other works etc.including the cost ofposition cement concrete of specified grade including the cost ofcentring and shuttering, tamping, ramming, vibrating,curing, in anyshape,position,thickness and finishing the top surface rough or smooth,etc. all complete as per directions of Engineer-in-charge. - All work upto plinth levelManufactured sand is permitted based on meeting the acceptance criteria | M3 | 1 |
23 | 9027803 | ITC CCTV SYSTEM | Installation, testing & commissioning of entire CCTV system | LS | 1 |
24 | 9027807 | OFC ACCESSORIES | Supply, installation and commissioning of OFC accessories | LS | 1 |
25 | 9027805 | SITC 6M OCT POLE | Supply, installation and commisioning of 6 m octagonal pole | EA | 1 |
Signature of Bidder
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
17908.zip
zip • 6.74 MB
BUDGETDOC_17908.xlsx
xlsx • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .