Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAdmitted-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹44.3 L | L1 | Admitted-Finance |
| 2 | L2₹49.1 L+₹4.9 L (11.0%)Admitted-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | ₹49.1 L+₹4.9 L (11.0%) | L2 | Admitted-Finance |
| 3 | L3₹50.1 L+₹5.9 L (13.3%)Admitted-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹50.1 L+₹5.9 L (13.3%) | L3 | Admitted-Finance |
| 4 | L4₹52.3 L+₹8.0 L (18.2%)Admitted-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹52.3 L+₹8.0 L (18.2%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical KUSHAL KONWAR PATH PROFESSOR COLONY RANGAGORA ROAD TINSUKIA ASSAM | TINSUKIA | TINSUKIA | ASSAM | 786125 | - | - | Rejected-Technical Rejected being not enlisted in the category |
| Sl No | Description | Qty | Unit | M/s Singh enterprises L1 | M/s PRABIR ENTERPRISE L3 | M/S SINGH TRADERS L2 | MAA COMMUNICATION L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. | 294.76 | Cum | 330 ₹97,270.8 | 290 ₹85,480.4 Lowest | 350 ₹1,03,166 | 320 ₹94,323.2 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. | 265.28 | Cum | 100 ₹26,528 | 100 ₹26,528 | 70 ₹18,569.6 Lowest | 130 ₹34,486.4 |
| 3.00 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. | 29.48 | Cum | 120 ₹3,537.6 | 110 ₹3,242.8 | 100 ₹2,948 Lowest | 130 ₹3,832.4 |
| 4.00 | Taking up or down 20mm bore, Steel tubing and connections and removing from site of work complete all as specified and directed. | 60 | RM | 15 ₹900 Lowest | 30 ₹1,800 | 20 ₹1,200 | 40 ₹2,400 |
| 5.00 | Taking up or down 25 or 32 mm bore, Steel tubing/PP-R pipe and removing from site of work complete all as specified and directed. | 390 | RM | 20 ₹7,800 Lowest | 40 ₹15,600 | 35 ₹13,650 | 50 ₹19,500 |
| 6.00 | Taking up or down 40 or 50mm bore, Steel tubing/PP-R pipe and removing from site of work complete all as specified and directed. | 48 | RM | 20 ₹960 Lowest | 45 ₹2,160 | 40 ₹1,920 | 55 ₹2,640 |
| 7.00 | Taking up or down 80 or 90mm bore, Steel tubing/ PP-R pipe and removing from site of work complete all as specified and directed. | 310 | RM | 50 ₹15,500 Lowest | 60 ₹18,600 | 55 ₹17,050 | 70 ₹21,700 |
| 8.00 | Taking up or down 100 or 110mm bore, Steel tubing/ PP-R pipe and connections and removing from site of work complete all as specified and directed. | 270 | RM | 100 ₹27,000 | 70 ₹18,900 | 65 ₹17,550 Lowest | 80 ₹21,600 |
| 9.00 | S & F in repair for cast iron fittings for spigot and socketed pipe, such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and pigot) collars, caps and plugs etc upto 150mm bore complete all as specified and directed. | 200 | Kg | 350 ₹70,000 | 345 ₹69,000 | 340 ₹68,000 Lowest | 355 ₹71,000 |
| 10.00 | Supply, laying, connection and testing, 110mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed | 150 | RM | 1,950 ₹2,92,500 Lowest | 2,000 ₹3,00,000 | 2,200 ₹3,30,000 | 2,030 ₹3,04,500 |
Tender Value
₹42.8 L
EMD Value
₹85,600
Closing Date
29 Jul 2026, 6:00 pmClosed
GE 872 EWS
GE 872 EWS PIN 913872 C/O 99 APO
REPAIRS/REPLACEMENT OLD UNSV RUSTED PIPELINE, PUMP/MOTOR, CLEANING OF OVER HEAD TANK AND CONNECTED WORKS AT ZONE I AND III OF LIKABALI MIL STN UNDER GE 872 EWS
2026_MES_769596_2
8856/E8
Open Tender
Miscellaneous Works
Works
270 days
LIKABALI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹85,600
27 Aug 2026
13 Jul 2026
31 Jul 2026
13 Jul 2026
29 Jul 2026
21 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. | 294.76 | Cum | - | - |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. | 265.28 | Cum | - | - |
| 3 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. | 29.48 | Cum | - | - |
| 4 | Taking up or down 20mm bore, Steel tubing and connections and removing from site of work complete all as specified and directed. | 60 | RM | - | - |
| 5 | Taking up or down 25 or 32 mm bore, Steel tubing/PP-R pipe and removing from site of work complete all as specified and directed. | 390 | RM | - | - |
| 6 | Taking up or down 40 or 50mm bore, Steel tubing/PP-R pipe and removing from site of work complete all as specified and directed. | 48 | RM | - | - |
| 7 | Taking up or down 80 or 90mm bore, Steel tubing/ PP-R pipe and removing from site of work complete all as specified and directed. | 310 | RM | - | - |
| 8 | Taking up or down 100 or 110mm bore, Steel tubing/ PP-R pipe and connections and removing from site of work complete all as specified and directed. | 270 | RM | - | - |
| 9 | S & F in repair for cast iron fittings for spigot and socketed pipe, such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and pigot) collars, caps and plugs etc upto 150mm bore complete all as specified and directed. | 200 | Kg | - | - |
| 10 | Supply, laying, connection and testing, 110mm outer dia 3- layer PP-R Polypropylene random copo-lymer) pipes SDR 7.4 & PN16 stablised and antimi-crobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed | 150 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tenderdoc.pdf
Tender Documents • 1.35 MB
BOQ_871553.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .