| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹48.7 L+₹67,290 (1.40%)Rejected-Finance NO 306 SCION AVENUE 4TH A CROSS KAGGADASPURA NEAR GANAPATHI TEMPLE BANGALORE 560093 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-Finance Other than lowest Bidder | |
| 3 | L3₹50.8 L+₹2.8 L (5.89%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-Finance Other than lowest Bidder | |
| 4 | L4₹50.9 L+₹2.9 L (5.98%)Rejected-Finance | L4 | Rejected-Finance Other than lowest Bidder | |
| 5 | L5₹51.7 L+₹3.7 L (7.64%)Rejected-Finance | L5 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹56.5 L
EMD Value
₹1.1 L
Closing Date
29 Jan 2025, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
82564/E8 Repair/Maint to Roof treatment and misc B/R items of certain OMQs and OTMs Domestic area at AFS Sulur
2025_MES_691506_1
82564/E8 Repair/Maint to Roof treatment and misc B/R items of certain OMQs OTMs at AFS Sulur
Open Tender
Construction Works
Item Rate
180 days
Sulur
Class C Category a(i)
7 documents required · 7 mandatory
₹1,000
GE AF Sulur
₹1.1 L
Yes
13 Feb 2025
2 Jan 2025
31 Jan 2025
2 Jan 2025
29 Jan 2025
23 Jan 2025
2 Jan 2025 - 14 Jan 2025
Amount
M&L for disconnecting and taking down existing Rotational moulded polythene water storage tank exc 500 Ltrs capacity but n.exc 1000 Ltrs capacity, keeping in safe custody and refixing in the same position including new fittings etc after roof repair work complete all as specified and as directed.
S&F in repair of ball valves of 20mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (Minimum weight 20 gms-210 gms) complete all as specified and directed.
M&L taking down existing Rotational moulded polythene water storage tank exc 250 Ltrs capacity but n.exc 500 Ltrs capacity complete all as directed
M&L taking down existing Rotational moulded polythene water storage tank exc 500 Ltrs capacity but n.exc 1000 Ltrs capacity complete all as directed
S&F 500 ltrs rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) incl connecting up pipes securing access covers etc all as specified
S&F 1000 ltrs rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) incl connecting up pipes securing access covers etc all as specified
S&F in repairs 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) concealed pipe SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down existing GI pipe & fittings complete all as specified and as directed.
S&F in repairs 20 mm outer dia of pipes3-layer PP-R (Polypropylene random copolymer) concealed pipe SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down existing GI pipe & fittings complete all as specified and as directed. Note for item No 8 & 9:- (a) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accessories such as pipe hooks, screws clamps etc. (b) Wall thickness of pipes shall be all as per IS : 15801
S&F in repairs 20mm outer dia PPR gate valves (brass insert) as per requirement of sites complete all as specified and as directed.
S&F in repairs 25mm outer dia PPR gate valves (brass insert) as per requirement of sites complete all as specified and as directed.
S&F in repairs 25 mm PP-R Ball valves (brass insert) as per requirement of the site complete all as specified and directed.
M&L Water proofing treatment of existing roofs as specified below (Ref item No.12.1 ) after complete removal of existing water proofing treatment and expose of top surface of RCC slab of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to outside the MOD land complete all as specified and as directed :-
Item No.12 Contd.... (a) Surface shall be made free from any loose paint, dust or grease. Remove all existing bitumen coatings completely by using intense wire brushing, high speed water jet & vacuum cleaner for thorough cleaning of the surface to avoid ‘Peeling off’ problems. (b) All cracks at corner joints, channels and parapets should be properly treated. For filling cracks upto 3mm crack seal material of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical to be used. Bigger cracks, damaged portions & hollow areas must be repaired with polymer modified cement mortar. (c) Apply a coat of self priming smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical with 33% dilution with water using brush/roller on newly plastered surface after curing as per IS-456 and allow to dry for 4 to 6 hours (dilution & forced coverage requirement strictly as per manufacturer’s instructions). (d) After the primed surface has dried, apply first coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same primed surface & allow to dry for 4 to 6 hours. (e) Prepare for apply 2nd coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same surface. The temp to be maintained 25 to 35° C through out the all above application work. (f) In case of severe dampness an additional coat of damp proof materials to be applied.
Note for item No.12 (i) The work shall be carried out through authorized and qualified applicators of the manufacturers ( M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical) only. (ii) MOU between contractor and manufacturere shall be submitted before commencement of water proofing work. (iii) A performance guarantee certificate for 10 years from the certified date of completion of work shall be submitted by the contractor to the GE in specified format. (iv) The unit quoted rate is deemed to include taking down of water pipeline, tanks, wires (etc as required) found on roof and refix at the original position after completion of roof treatment . (v) The unit quoted rate shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto approx 7.5 mtr height from natural ground level. (vi) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at height exceeding 3 to 25 mtr height shall be mandatory and deemed to be included in the unit rate quoted.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregates as in roof or in any position to bring upto the slope of average thickness of 50 mm including demolition of existing concrete complete all as specified and directed.
Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed.
M&L for rendering 15mm thick in two layers ( ie 5mm thick in CM 1:4 mixed with water proofing compound over 10mm thick back coat in CM 1:4) on external wall surfaces finished even & fair complete all as specified and as directed. Note: WPC shall be measured and laid separately.
M&L for rendering 10 mm thick on brick or concrete surfaces of internal wall in CM 1:6 (other than fair face) without using extra cement complete all as specified and directed.
M&L for Preparation of plastered or un plastered new surfaces of walls, Chajja, balcony, facia etc. and applying two coats of cement based paint over a coat of suitable primer complete all as specified and directed.
M&L Preparation of new plastered surfaces of wall and applying two coats of Oil emulsion Distemper over a coat of alkali resistant priming paint complete all as specified and directed.
Supply Only integral water proofing compound complete all as specified and as directed.
Demolition of brick masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and as directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 , complete all as specified and as directed.
All as per item No.21 here in above but except bricks. Note:- Serviceable bricks obtained from demolition of brick masonry vide item No.21 shall be re-used.
M&L for Brickwork with fly ash brick, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and as directed.
Demolition of cement concrete (reinforced) in of any description and in any position and removal of debris out of MD land complete all as specified and directed.
M&L Precast RCC 1:2:4, Type B1 using 20mm graded stone aggregate as in landings, cover slabs, challah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. Note:- Reinforcement shall be measured and paid separately.
M&L for Formwork to challah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
M&L High strength corrosion resistant TMT steel bar of grade Fe-500 , 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L complete removal of existing finishes from old surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efflorescent salt, treating oil and greasy spots etc and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion weather proof paint complete all as specified and as directed.
M&L 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall including taking down existing complete all as specified and as directed.
M&L PVC bends 110mm bore including taking down existing one complete all as specified and as directed.
M&L PVC (SWR) 110mm junction (single T) equal or unequal provided with access door including taking down existing one complete all as specified and as directed.
M&L PVC (SWR) 110mm vent cowl all as specified including taking down existing one complete all as specified and as directed.
M&L in repairs Stack clamps made out of 50 mm x 5 mm flat iron and 110 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore pipe complete all as specified and directed.
S&F in repairs 150mm dia of half round ready made PVC (SWR) eaves gutter of pressure rating 6 kg/cm2 of approved make including necessary fitting like bend WC/MS clips etc complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall including taking down existing PVC Rain Water Pipes (any size) along with all fittings heads bends etc complete all as specified and as directed.
S & F in repairs PVC (SWR) bends any radius 75 mm dia fixed to wall complete all as specified and as directed.
S & F in repairs PVC (SWR) 75mm bore junction (single T) equal or unequal provided with access door complete all as specified and as directed.
SCION ENTERPRISES (BID ID -3227047)
SAMYDOSS CONSTRUCTIONS (BID ID -3226755)
srilakshmi industries (BID ID -3226411)
G Perumal and co (BID ID -3226516)
ABHISHEK CONSTRUCTIONS (BID ID -3226712)
KUMAR AGENCIES (BID ID -3225718)
D.R ASSOCIATES (BID ID -3226539)
A.GOVINDARAJ (BID ID -3226221)
T C KARUNANITHI (BID ID -3225969)
Lucky Enterprises (BID ID -3226601)
p.chinnasamy (BID ID -3225540)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .