Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Elgible |
| 2 | Rejected-Technical VILL P O BAHIRI DIST BIRBHUM PIN 731240 | BIRBHUM | BIRBHUM | WEST BENGAL | 731240 | Rejected-Technical Not Eligible, Plz. see Technical Bid Evaluation Report |
| 3 | Rejected-Technical | Rejected-Technical Not Eligible, Plz. see Technical Bid Evaluation Report |
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
16 Mar 2026, 1:00 pmClosed
Sr. Superintending Engineer
Office of the Superintending Engineer, P.W.D., Western Circle No.-I, Court Compound, Bardhaman, Purba Bardhaman
Construction of 2 Two Pump Fire Station Building Type C at Tarapith in the District of Birbhum
2026_PWD_1009639_1
WBPWD/SE/WC-I/ENIT-26/2025-26
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
300 days
Birbhum
Please refer Tender documents.
7 documents required · 7 mandatory
₹7.2 L
Yes
Burdwan
2 Apr 2026
18 Feb 2026
18 Mar 2026
18 Feb 2026
16 Mar 2026
23 Feb 2026
23 Feb 2026
BUILDING WORKS : Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. 125mm th. Wall in Foundation
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) a) With earth obtained from excavation of foundation.
c ) (ii) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth.
A) Filling in foundation or plinth by silver sand in layer not exceeding 150mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). (B) Do - by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Pre-Constructional Anti-termite measures: Pre-Constructional Anti-termite measurest- Antitermte treatment to bottum surface ( in case of masonry foundation and basements) and the sides ( upto a height of 309 mm. From bottom) of the excavation trenches with chemical emulsion by admising Imidacloprid emulsifiable concentrates (105ml in 50 titres) with water at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 7.2.1. of code 15-6313 (part-11) 2013. (Mode of measurment will be the plan area of foundation treated.)
Pre- Constructional Anti termie measures : Antitermite treatment to the top surfacee of the consolidated carth within plinth walls with chemical emulsion by admbing Imidacloprid emulsifiable concentrates (105ml in 50 litres) with water at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Hole upto 30 min. te 75 mm, deep at 150 mm. centre to centre both ways shall be made with 12 mm, diaetre mild steel rod on the surfacee to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3. of code 15-6313 (part-11) 2013. (Mede of measurment will be plan area of plinth treated)
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor. (A) [Pakur Variety] (a) 1:3:6 proportion
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (i) Pakur Variety M 25 Grade Ground Floor
At First floor.
In 2nd floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, as per relevant IS codes. In Ground floor.
In First floor.
In 2nd floor
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).
Extra rate for adding Polyester Fibre anti shrinkage material @ 0.25% by weight of cement [or as per Manufacturer's Specification] as secondary reinforcement to arrest hair crack in concrete including cost of Fibre .
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (f) 25 mm to 30 mm shuttering without staging in foundation
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. In Ground Floor
In First Floor
In 2nd Floor.
Labour for chipping of concrete surface before taking up plastering work.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (ii) JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL In Ground Floor
In First Floor
In 2nd Floor.
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
(b) In superstructure, Ground floor
In First Floor
In 2nd Floor.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
In First Floor
In 2nd Floor.
Extra for using approved H.B netting in every third layer in 16 & 17 of subhead A above in any floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian. In Ground floor
In First Floor
In 2nd Floor.
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf)
Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer‟s specification and direction of Engineer-in-Charge
Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor.
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection of workmanship). Without integrated grills. (a) Fixed type steel windows as per IS sizes with horizontal glazing bars.
(v) Two point nose steel handle including fitting and fixing
(vi) Steel peg stay 300mm long including fitting and fixinng
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (ii) Grill weighing above 10 Kg/sq.mtr and upto16kg/m2 In Ground floor
In First Floor
In 2nd Floor.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) In ground floor. In Ground floor
In First Floor
In 2nd Floor.
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film. Natural white. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. [Note : for estimate purpose construction wing may consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M]
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. iv) 5mm thick coloured / tinted / smoke glass.
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark. (vii) 100mm. X 58mm. X 1.90mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 225mm long x 12mm dia. bolt (ix) 300mm long x 10mm dia. bolt.
(iv) 150mm long x 10mm dia. Bolt
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300 mm long
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete. (a) With continuous plate base (Hexagonal/ Round rod). (vi) 150 mm grip x 10 mm dia rod.
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
(i) Door stopper.(Brass)
(c) Supplying 6 levers 'Godrej' Crystal Satine Mortice Lock with keys including fitting & fixing complete.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster In Ground floor
In First Floor
In 2nd Floor.
15 mm thick plaster In Ground floor
In First Floor
In 2nd Floor.
(ii) With 1:4 cement mortar (c) 10 mm thick plaster In Ground floor
In First Floor
In 2nd Floor.
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative. Ground Floor
In First Floor
(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative In Ground Floor
In First Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick). In Ground floor.
In First Floor
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] In Ground Floor
In First Floor
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for jointing @1.8 kg/Sq.m] In Ground Floor
In First Floor
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge. (b) Slab Thickness above 25 mm and upto 37.5 mm In First Floor
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structuralmemebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the ratefor each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For roof truss works a) Span up to 12 Mtr
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (i) 16 mm dia bolt (a) 300 mm long
Supplying, fitting & fixing 1.5mm thick Plain Corrugation Polycarbonate clear sheet made of national brand, excluding the supporting frame work, fitted and fixed with 10mm dia x55mm Self-driving screws, EPDM washers and putty complete with 150mm end lap and one corrugation minimum side lap complete as per specification & direction of Engineer - in - charge including materials, labour, taxes and all other incidental charges. (Payment to be made on area of finished work ).
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old ornew surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats, In Ground Floor
In First Floor
In 2nd Floor.
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion
In First Floor
In 2nd Floor.
(a) Rendering the surface of walls and ceiling with plaster of paris (thickness not less than 1.5 mm.). In ground floor, 1st floor & 2nd floor.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat ii) Solvent based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete. (a) 50 mm. Thick panels I. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL In Ground floor
In First Floor
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes:(c) 160 mm
A) UPVC Pipes:(b) 110 mm
a) Plain Tee 160 mm
b) Plain Y 160 mm
c) Bend 87.5 degree 160 mm
d) Shoe 160 mm
xi) Pipe Clip 160 mm
a) Plain Tee 110 mm
b) Plain Y 110 mm
c) Bend 87.5 degree 110 mm
d) Shoe 110 mm
xi) Pipe Clip 110 mm
S & P WORKS : Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) a) For Exposed Work PVC Pipes (i) 15 mm dia.
(ii) 20 mm dia.
(iii) 25 mm dia.
(iv) 32 mm dia.
(v) 40 mm dia.
(vi) 50 mm dia.
(b) For Concealed Work (i) 15 mm dia.
(ii) 20 mm dia.
Supplying, fitting and fixing shower of approved brand and make. (a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 50 mm Dia
40 mm Dia
32 mm Dia
25 mm Dia
20 mm Dia
Supplying, fitting and fixing bib cock or stop cock. (a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
(c) (i) Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand).
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing pillar cock of approved make.a) (ii) CP Pillar Cock Super Deluxe with Aerator - 15 mm. (Equivalent to Code No. 508 & Model No. Tropical / Sumthing Special of ESSCO or similar brand). In All Floor
e) (i) CP Centre hole Basin mixture with regular spout without popup waste system with 450 mm long braided hoses. (Equivalent to Code No. 5167(B) & Model - FLORENTINE of JAQUAR or similar brand). In All Floor
f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand). In All Floor
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length. (c) 160 mm
ix) Bend 45º 110 mm
xi) Door Bend (T.S.) 110 mm
iii) Door Tee 110 mm
xv) Vent Cowl 110 mm
xvi) Pipe Clip 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground 110 mm
(B) Under ground 160 mm
Supplying,fitting and fixing cast iron 'P' or 'S' trap conformimg to I.S. 3989 / 1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). P trap (iv) 150 mm
Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap (with vent)
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.(b) Anglo Indian (i) Plastic (hallow type) white
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. ii) C. P. Flush Pipe
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete. (i) 635mm X 395 mm X 420 mm
Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (i) 450 mm x 350 mm
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (b) C.P. urinal flush pipe fittings range of two
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished.
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming I.S. specification with P.V.C. fittings complete,C.I. brackets including tcoats of painting to bracket etc.
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (v) 900 mm long
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (ii) 1050 mm long
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 630 mm X 450 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only. (ii) 630 mm X 550 mm X 180 mm
Supplying, fitting and fixing glass shelf with aluminium guard rails. (a) Ordinary type with 5.5 mm sheet glass(ii) 600 mm X 125 mm
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.(ii) 600 mm X 450 mm
Supplying, fitting and fixing porcelain soap tray of approved make. (i) Recessed soap tray of size 150 mm X 150 mm
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass(ii) 25 mm dia. and 750 mm long
Supplying, fitting & fixing Aluminium domical grating.(i) 150 mm
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only).(i) 1050 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 300 mm dia. of approved make A) With Pakur Variety. JSW/JSPL/SHYAM/SRMB...
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. A) With Pakur Variety. (iv) For 50 users JSW/JSPL/SHYAM/SRMB…
(iv) For 20 users JSW/JSPL/SHYAM/SRMB…
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. A) With Pakur Variety. JSW/JSPL/SHYAM/SRMB...
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity. (a) Upto 1st story from G.L.
(b) Extra for each additional story
Labour for punching hole in plastic water storage tank upto 50 mm dia.
DRIVE WAY (C.C.) : Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a)Depth of excavatin not exceeding 1500mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) By Fine Sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor. (A) [Pakur Variety] (a) 1:3:6 proportion
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety. Ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of G.F.) (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. i) G.F.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (ii) JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL i) Ground floor.
DRIVE WAY (PAVER BLOCK) : Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. Depth upto 150mm
(b) For each additional Depth of 150mm and part thereof. 150 mm to 775 mm
Supplying, spreading and compacting Sand to required thickness, in layers not exceeding 150 mm to proper gradient and camber, inundating each layer by water and packing and ramming layer by layer to achieve desired compaction, including lighting, guarding, barricading and making adequate earthen bundh where necessary, curing with water as per direction, mending cracks and depressions by ramming wherever necessary. (Medium Sand)
Construction of Granular Sub-Base (GSB) by providing graded pakur stone material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). By providing pakur variety stone (ii) GSB Grade-V
Water Bound Macadam Base Course Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2mm) B. Manual Means
Plain / Reinforced Cement Concrete in Open foundation with or without reinforcements, in any part of foundation of bridges / culverts with graded stone chips of appropriate nominal sizes, including screening and cleaning of coarse aggregates, fine aggregate (sand) conforming to proper grading zone, both of approved quality and cement, as necessary, cost of curing with water, including cost and carriage of all materials and including preparation of design mix, approval of the same by the Engineer-in-Charge, cost for quality control, sampling, testing etc. including cost of formwork but excluding reinforcement complete as per drawing and technical specifications. PCC Grade M30 Using Concrete Mixer
Supplying and Laying in the specified pattern of interlocking concrete block pavements (ICBP) with concrete blocks (with concrete grade as specified as per table 1 of IS 15658:2006) manufactured in steel mould clamped to a vibrating table by hydraulic pressure (as per CL.NO. 6.30 of IRC :SP :63(2018), from BIS license manufacture ,with spacer nib (small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks used as per CL NO. 3.26 of IS: 15658 ) and of specified size and shape with aspect ratio(the ratio of length to thickness of a paver blocks, as per CL NO. 3.3 of IS :15658 as per table 2 of IS:15658 with flexural strength /breaking load as per annexure G of IS: 15658 on the prepared base course of specified CBR as per table 1 of IRC SP 63(2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35mm thick ( grading of the bedding sand as per clause 6.5.1 of IRC SP 63 ) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63 ) and completing in the edges with cut blocks as per CL. NO. 8.7 of IRC SP-63 (2018) with proper confinement of bedding and joint filling sand, compacting, levelling and filling up of the edge gap. 80 mm thick Grey
BOUNDARY WALL : Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a)Depth of excavatin not exceeding 1500mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) By Fine Sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches.
I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor. (A) [Pakur Variety] (a) 1:3:6 proportion
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of G.F.) (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. i) G.F.
(f) 25 mm to 30 mm shuttering without staging in foundation
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety. Ground floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (ii) JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL i) Ground floor.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs (ii) Grill weighing above 16 Kg./sq.mtr and above i) In Ground floor.
M.S. gate of Jail type as per approved design made of strong M.S. frame work,intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. Ground Floor
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) (ii) With 4:1 cement mortar I) In Ground Floor. (c) 15 mm. thick plaster
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the Engg-in-charge. [One Coat] I) In Ground Floor.
Protective and decorative Acrylic exterior emulsion paint of approved quality as per manufacturor's specification and as per direction of Engineer - in - Charge to be applied over acrylic primer as required. The rates includes the cost of materiels, labour,scaffolding and all other incidental charges but excluding the cost of primer b) Normal Acrylic Emulsion I) In Ground floor [ 2 coats.]
(b)Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : b) on the steel or other metal surface : with super gloss ( hi-gloss) iv) Two coats (with any shade except white)
(a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary.
Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete. (i) 10 mm. dia. (b) 200 mm.
Supplying galvanised staples fitted and fixed (b) 32.5 mm. to 37.5 mm. size
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. I) For structural members of specified sections weighing less than 22.5 Kg./m ( Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished tructural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a hight of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof.)
SUB-MERSSIBLE PUMP (2 Nos.) : Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. 1) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia. (i) First 50 metre
(ii) Next 50 metre
(ii) Next 50 metre
(iv) Rest 100 metre
Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in Charge (b) 150 mm nominal dia (i) 6.0 mm wall thickness
Supplying, fitting and fixing G.I. cap at top (v) 150mm dia
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (iii) 75 mm dia.
Supplying, fitting and fixing plug of approved make conforming to I.S specifications (iii) 75 mm dia.
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) 40 mm dia
50 mm dia.
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes 150 mm dia.
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (iv) 40 mm dia
(v) 50 mm dia
KSB CORA 100 with three phase UMAI 100 motor 1.5 KW/ 2 H.P.
1.5 KW/ 2 H.P. Submersible Pump Controller
Finolex 3 Core Flat Cable Bare Bounched copper cable for 56/3 etc.
Geophysical investigation of the acquifer by electrologging system with altools and plants as necessary including supply of necessary report.
UNDER GROUND RESERVOIR : Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a)Depth of excavatin not exceeding 1500mm.
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) By Fine Sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, as per relevant IS codes. a) Panchami Variety
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 30 Grade i) In Ground floor.
M 25 Grade i) In Ground floor.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (ii)JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.
a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent: 4 water : 6 cement) as per Manufacturer's specification
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of G.F.) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. i) Ground floor.
(f) 25 mm to 30 mm shuttering without staging in foundation
Labour for Chipping of concrete surface before taking up Plastering work.
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
(b) In superstructure, Ground floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(c) Sal : Malayasian. (The quantum should be corrected upto three decimals) In Ground Floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). (e) Sal : Malayasia (a) 40mm X 6mm, 250mm Length
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf)
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (ii) Grill weighing above 10 Kg/sq.mtr and upto16kg/m2 In Ground Floor
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film. Natural white. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. [Note : for estimate purpose construction wing may consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M]
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. iv) 5mm thick coloured / tinted / smoke glass.
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: 125 x 63 x 4.0mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 225mm long x 12mm dia. bolt
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300 mm long
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) I) In Ground Floor. (i) With 6:1 cement mortar (c) 20 mm. thick plaster
(ii) With 4:1 cement mortar (c) 15 mm. thick plaster
(c) 10 mm. thick plaster
Neat Cement Punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 Sq.m.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the Engg-in-charge. [One Coat]
Protective and decorative Acrylic exterior emulsion paint of approved quality as per manufacturor's specification and as per direction of Engineer - in - Charge to be applied over acrylic primer as required. The rates includes the cost of materiels, labour, scaffolding and all other incidental charges but excluding the cost of primer b) Premium 100% Acrylic Emulsion I) In Ground floor [ 2 coats.]
Artificial Stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In Ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (i)35 mm. thick
ELECTRICAL WORKS : SUB-HEAD 1--DISTRIBUTION WIRING : Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. Average run 6 mtr
Average run 10 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC On Board
SUB-HEAD 2--CUTTING CHANNEL & CABLE, WIRE LAYING : Cutting Channel of required size (i.e. 31mmx31mm or 40mmx40mm or 43mmx43mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 13 mm dia 3 mm thick
19 mm dia 3 mm thick
25 mm dia 3 mm thick
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 3 x 22/0.3 (1.5 sqmm)
2x36/0.3(2.5sqmm) + 1x22/0.3(1.5sqmm) as ECC
2x(4 sqmm)+1x(2.5 sqmm)
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5 sq.mm
Supply of following XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make- Havells / Polycab/ RR KABLE/ As per choice of EIC] ] 4 core 70 sq. mm. multy stranded alluminium conductor Armoured cable.
4 core 120 sq. mm. multy stranded alluminium conductor Armoured cable.
Supplying and fixing compression type gland and socketting of those for following XLPE / PVC armoured cable (2/4 / 3.5) Core as per GS & finishing. 4 core 70 Sq. mm
4 Core 120 Sq. mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 50 mm dia,
80 mm dia,
Laying of cable as below, after cutting floor /pavement / wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Incl. following size GI [Hot Dip] Wire as Earthing as per GS. Above 35 sqmm to 95 sqmm incl earthing attachment in 2x 4 SWG GI [Hot Dip] Wire as per GS.
Above 95 sqmm incl earthing attachment in 2x 4 SWG GI [Hot Dip] Wire as per GS.
S & F G.I cable looping box of size (250x250x100)mm with all accessories as per GS on wall.(250x250x100)mm
SUB-HEAD 3--PANEL, VTPN, HTPN, SPNDB, MAIN SWITCH ETC : S & Fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T/Seimens/Havells) 200A
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment( make:Legrand or choice as per EIC) Upto 250A 8 way
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. ( make:Legrand or choice as per EIC) 250A
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand /L&T/ABB/Simens) 4 Way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand /L&T/ABB) 40 A DP
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+16 Way[ Legrand/L&T/ABB ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS[ Make -Legrand/L&T/ABB] 6-32A SP
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. 8 Way Vertical
S & F AC Machine/Compound Light timer for two nos. machine fabricated with Timer DB ( as per Crabtree, Cat No. DCDIN002 ) incl. 6A Moduler Two way Switch 240V, 32A DP MCB - 1 no. 240V, 25A SP MCB - 2 nos. 240V, 40A SP MCB Isolator ( as per Crabtree Cat No. DCMFOSPX040 ) - 2 no. Half Module Single Phase Indicator RED & GREEN (as per Crabtree Cat No DCMFOSPX040) 2 Nos. 25A TP Power Contactor with 380V coil voltage, - 2 no. 24 Hours Digital Time Switch - 1 no. (Make: L & T / Legrand / Schneider )
SUB-HEAD 4-- PLUGS & SOCKETS : Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 3 nos. 6 A & 1 nos. 16 A, 5 pin Modular type plug socket with 3 nos. 6 A & 1 nos. 16 A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos. 6 A 5 pin with 2 nos. 6 A, Modular type switch (Brand approved by EIC) without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc as per GS.
Supply & Fixing 240 V, 2x16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth connection.
Supply & Fixing Industrial type DOL Starter on Angle iron base by nut, bolts [Make:- L&T/As per choice of EIC] having following features, model & Cat. No:- 5.5kW, 3Ph, 415V, MK1 DOL, SS96228
15kW, 3Ph, 415V, ML2 DOL, SS90702
SUB-HEAD 5 - SUPPLY AND FIXING OF LIGHT FITTINGS : Supply & fixing of 4 feet Industrial box type Twin 2x20 LED fittingsuspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length : make philips CAT no.TMC502 2XTLED22/865T8I/Surya/Jaquar] (as per choice of EIC) (with 3 years warrenty)
Supply & fixing of 4 feet Industrial box type Single 1 x20 LED fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length : make philips CAT no.CAT no.TMC502 1XTLED22/865T8I/Surya/Jaquar] (as per choice of EIC) (with 3 years warrenty)
S & D of 9/10 watt LED Bulkhead light fittings complete with glass shed, wire net guard including LED lamps with minimum Luminous Efficacy 100lm/W. (Make :- Crompton/philips/jaguar) (as per choice of EIC) (with 5 years warrenty)
S & F 9/10 watt LED Lamp (Make :- Philips/Surya/Jaquar) (as per choice of EIC)
SUB-HEAD 6 -- FIXING OF FANS : Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop
Extra for additional one letter incl. hifen, stroke and stop
Painting upto 10 letters of the engraved number with approved black /red paint as required
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm / 9''
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 23 cm / 9''
SUB-HEAD 7 -- SUPPLY OF FANS : Supply of 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS (Make - as per choice of EIC) (with 2 years warrenty) 1200 mm Sweep (CROMPTON Model-HIGH SPEED HS)
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. (Make - ar per choice of EIC ) 9" ( 230mm ) Speed 1370 RPM
12" ( 300mm ) Speed 1420 RPM
Supply of 450 mm (i.e. 18") sweep, 98 w, 1370rpm, Wall Bracket fan complete with metal body metal blades, etc as per GS (Make -ar per choice of EIC ) (with 2 years warrenty)
SUB-HEAD 8 - SUPPLY AND FIXING OF CALL BELL : Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
SUB-HEAD 9 -- EARTHING : Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum soil for 2 set dual earthing.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below : By TATA-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F 20 mm x 3 mm Galvanised (Hot Dip) MS Flat on wall / floor with GI saddles as required and connection to equipments with incl. drilling holes, bolts, nuts, washers etc.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe.
Add GST @ 18%
Add Labour Welfare Cess @ 1%
BIDDER INFORMATION SHEET (Bidders are requested to please fill up carefully and upload without fail. Any information mismatching with the uploaded documents may cause rejection.
Name of the Bidder
Bid Submitted for (NIT No.)
Tender ID.
BIDDER DETAILS
CREDENTIAL FOR SIMILAR NATURE OF WORK
INFORMATION FOR EQUIPMENT / PLANT AND MACHINERY
Name of the Machinery
Tilting drum Mixer Materials or Electric operated with a minimum size of 230-280 liters automatic water measuring system and integral weigher (Hydraulic/Pneumatic type)
Invoice No.
stage.html
html • 0.03 MB
technical_2478688.pdf
techsummary_2478688.pdf
cancelled_1.pdf
pdf • 0.05 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 10.62 MB
Special_Conditions_of_Contract_ElectricalWorks.pdf
Tender Documents • 0.59 MB
BOQ_2478688.xls
BOQ • 0.58 MB
2911.pdf
Tender Documents • 0.51 MB
BIS.xls
Additional Documents • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .