Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Lowest one | |
| 2 | L2₹48.9 L+₹5.5 L (12.7%)Rejected-Finance GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | L2 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹99,300
Closing Date
17 Sept 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
Dr Homi Bhabha Road Navy Nagar Colaba Mumbai
PROVISION OF PROTECTIVE CEILING FOR NOFRA MAIN GATE AT NOFRA AND ADDITION ALTERATIONS TO BUILDING NO T 08 AND T 11 AT NOFRA UNDER GE NW NOFRA COLABA MUMBAI.
2021_MES_469798_1
8973
Open Tender
Civil Works
Item Rate
240 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹99,300
Yes
25 Jan 2022
21 Aug 2021
23 Sept 2021
21 Aug 2021
17 Sept 2021
4 Sept 2021
21 Aug 2021 - 3 Sept 2021
60 days
Amount
M&L for rendering 15mm thick CM 1:6 on fair face of brick work or concrete surfaces of walls and finised surfaces even and smooth without using extra cement complete all as specified and directed by Engineer in charge.
M&L for rendering, in ceiling, 10 mm thick cement plastering on brick or concrete surfaces in CM (1:4) finished even and smooth without using extra complete all as specified and directed by Engineer in charge.
M&L for preparation of new plastered or unplastered surfaces of walls including scrapping and applying two coats of oil bound distemper over layer of smooth Putty finish as required punning 3mm thick over a coat of primer strictly as per manufacture instruction with smooth roller finish complete all as specified and directed by Engineer in charge.
M&L for preparation of new plastered or unplastered surfaces of ceiling including scrapping and applying two coats of oil bound distemper over layer of smooth Putty finish as required punning 3mm thick over a coat of primer strictly as per manufacture instruction with smooth roller finish complete all as specified and directed by Engineer in charge.
M&L for Polished granite stone slab 18 to 20mm thick coloured as in cooking platform/ door sills, set and jointed with grey cement slurry and pointed in neat white cement slurry mixed with pigment to match the shade of floors, including moulding at front edge or both edges and 20mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer in charge. Note : Quality of granite all as approved by GE
Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface including sunk or raised moulding over and including metal frame work and GI wire mess complete all as specified and directed by Engineer in charge.
Supply & Fixing of 12mm thick plain toughened glass door/window with ething including aluminium framing, door handle, suitable hinges, rubber beading, floor spiring and all necessary fittings complete all as specified and directed by Engineer in charge.
M&L for 10mm thick digital coloured dark shade double charge vitrified tiles of size (square/ rectangular) polished area of each tiles n. exeeding 0.36 sqm in floor etc, with & including 5mm thick adhesive of Ferrouscrete (FERRO-1122) / Fevimate XL- Pidilite / Gold star of Bal Endura or equivalant including necessary roughning of existing PCC flooring & levelling the floor if required, grouting the joints complete all as specified and directed by Engineer in charge. Make : Kajaria , Somany , Orient bell
M&L for brick work built in cement mortar 1:6 with sub class B bricks straight or curved on plan exc 6m mean radius complete all as specified and directed by Engineer in charge.
M&L forGlazed ceramic tiles in vertical surfaces of size 300x200mmx7mm thick including over 10mm thick Screed bed or bedding layer in CM 1:4 for laying tile finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and directed by Engineer in charge.
M&L for 12 mm thick commercial plywood (IS), grade BWR,Type-BB fixed with screws to timber frame work including 1st class HW leaping all around the shutter/ edges including dismantling the existing boarding complete all as specified and directed by Engineer in charge. Make : Kit ply / Century ply / Anchor ply
M&L for 18 mm thick commercial ply wood (IS), grade BWR, type BB fixed with screw to timber frame work including 1st class HW leaping all around the shutter/ edges and also including 0.9mm thick decorative laminate type 1 (IS), of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions and including dismantling the existing boarding complete all as specified and directed by Engineer in charge.
M&L for 0.9mm thick decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed by Engineer in charge.
S&F in repairs Kitchen sink with double boul made of stainless steel 1mm thick with plugs washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe etc complete all as specified and directed by Engineer in charge. MAKE : Nirali / Blue star / Diamond.
S&F in repairs stainless steel grating cover 100mm dia fixed in repairs complete all as specified and directed by Engineer in charge.
S&F in repairs stainless steel plate rack of size 900X580X210 mm fixed to wall with screws complete all as specified and directed by Engineer in charge. Make: Bluestar / Nirali / Diamond
Supply and fix in repair 100 mm dia CI nahani trap jointed with run lead and making good to floor with existing tile complete all as specified and directed by Engineer in charge.
M&L framed brackets of angles, joist, channel, angle or tee sections fixed independently without connecting plates ect cut to shape (cut to ordinary length i.e within 20mm of the length indicated) drilled and countersunk for screws, including bending and welding as necessary, confirming to Fe-410-0 or Fe 310-0 complete all as specified and directed by Engineer in charge. Make: SAIL , TATA Steel , TISCO
S&F in repairs powder coated aluminum frame for door ,windows,ventilators etc.with one or more rebates including joining cleat for fixing etc.fixed type/louvered window or ventilator without sash bar, aluminum including necessary joining cleats, glazing clips,rubber packing,anodised aluminum snap beading,screws, sliding rollers, rubber gasket etc complete all as specified and directed by Engineer in charge. NOTE: a) Glazing shall be measured seperately. b) Item shall be paid as per weight of alluminium section. c) The rate quoted shall be inclusive of neoprene beading,glazing clips,screws, etc., as required which shall not be measured for arriving the weight. d) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area.
S&F in repairs for Powder coated aluminium door, window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed by Engineer in charge.
S&F 5.5mm thick glass sheet ordinary quality and glazing with oil putty fixed with beads in each pane in repair complete all as specified and directed by Engineer in charge.
Supply and fixing in repairs rotational moulded PVC tank 1000 LTR in position at any location on top of the building including removing existing tank disconnecting all incoming and out going connections, provision of new fittings suitable up to 80mm bore GI pipe all as per existing requirements complete all as specified and directed by Engineer in charge. Make :Sintex ,Infra,Polycon.
S&F in repairs stainless steel wire cloth (Wire dia 0.36 mm) and average width of aperture 1.40 mm and fixed with and including Ilnd class hard wood beading complete all as specified and directed by Engineer in charge.
S&F Table Top ceramic wash hand basin vitreous china oval shape smooth finish and (Colour approved by GE) of size 435x505x180mm, fonte with including fancy type piller tap, brass chromium plated waste coupling 32mm with long screwed and fly nuts ,incl 60 cm long,32mm dia PVC (flexible) type waste pipe fixed as in repairs complete all as specified and directed by Engineer in charge. Make : Jaquar cat part No KUS-WHT-35601 or its equivalent in CERA / HINDWARE
Supply and fix 15mm dia steel water tubing galvanised medium grade, with all fitting fixed complete to walls,duct and ceilings or laid in floor/wall/ceiling (in high rise building including scafolding) complete all as specified and directed by Engineer in charge. Make : Jindal / TATA / Swastik.
Supply and fix 25mm dia steel water tubing galvanised medium grade, with all fitting fixed complete to walls,duct and ceilings or laid in floor/wall/ceiling (in high rise building including scafolding) complete all as specified and directed by Engineer in charge. Make : Jindal / TATA / Swastik.
Supply and fix fancy type chromium plated brass angular stop cock suitable for 15mm bore GI tubing, with necessary fittings complete all as specified and directed by Engineer in charge. Make: Jaquar Cat Part No : CON-059KN or its equivalent in Kohler / Marc.
Supply and fix fancy type chromium plated brass Bib tap with wall flange suitable for 15mm bore GI tubing with necessary fittings complete all as specified and directed by Engineer in charge. Make: Jaquar Cat Part No : VGP-81037 or its equivalent in Kohler / Marc.
S&F in repaires 15mm pillar taps, cast copper alloy with captain heads chromium plated screw down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed by Engineer in charge. Make : Jaquar cat part no FLR-5015 or its equivalent in Kohler / Marc.
S&F 75 mm bore of sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall & including scaffolding upto 16th floor of building complete all as specified and directed by Engineer in charge.
M&L in repair 75mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) including complete all as specified and directed by Engineer in charge.
Material & labour for preparation of newly plastered wall surfaces and applying two coats of water proof paint (Rain coat of Dr. fixit or its equivalent in STP, Fosroc, Krishna as approved by GE) over a coat of wall primer (Dr. Fixit primeseal or its equivalent in STP, Fosroc, Krishna as approved by GE) complete all as specified and as per manufacturer's instruction.
S & F IInd Class Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed by Engineer in charge.
S&F roof tiles, Mangalore pattern, interlocking at side joints, laid dry including taking down complete all as specified and directed by Engineer in charge.
Supplying, fabricating and fixing for aluminium composite panel work as in ceiling, cladding etc in metallic colours of approved shade made out of 3mm thick aluminium composite panel material consisting of 2mm thick mineral core sandwiched between two aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with kynar 500 based PVDF/Lumiflon based fluoropolymer resin coating of approved colour and shade on exposed face and polymer (service) coating on other face, fixed over and including base frame fabricated with aluminium square pipe of size 25mmx20mm with 1mm wall thickness in 600mmx600mm size grid including stainless steel screws, nut, bolts, washers, cleats, weather silicone sealent for groove filling, backer rods etc,complete all as per Manufacturer instruction and as directed by Engineer in charge. Note : Work shall be carried out at any height, no any extra payment will be made for same.
S& F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 at any height including two coat of synthetic enamel paint over red oxide and necessary scaffolding complete all as specified and directed by Engineer in charge.
M&L for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile srtength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws at any height including necessary scaffolding complete all as specified and directed by Engineer in charge. Make : TATA / ESSAR / JSW.
M&L for preparation of new steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed by Engineer in charge.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer in charge.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic conduit of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular Cover plate concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- Make of wire - Polycab / Finolex / Havells Make of Conduit - Pressfit / Precision / Polycab
(a) One light point controlled by one switch SP one way.
(c) One Ceiling/Exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic conduit of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular Cover plate concealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly. Make of wire - Polycab / Finolex / Havells Make of Conduit - Pressfit / Precision
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular blank plate, One way, 1 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed by Engineer in charge. Make - Legrand / Gold Medal / Anchor
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (Nixon)
Supply and fix in repair Modular white cover plate with Frame 1 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 2 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 3 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 4 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 6 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 8 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular white cover plate with Frame 12 Module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 1 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 2 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 3 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 4 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 6 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA)
Supply and fix in repair Modular metal flush box 8 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor)/ Schneider (Zencelo)/ Goldmedal (WEGA))
Supply and fix in repair Modular metal flush box 12 module complete all as specified and directed by Engineer in charge. Make- Legrand (Arteor) / Schneider (Zencelo )/ Goldmedal (WEGA)
Supply and fixing Recess Mounting LED panel, 1'x1', 36 Watt capacity, CRCA housing, white powder coated, with polymer diffuser complete with acessories complete all as specified and directed by Engineer in charge. Make- Phillips/ Jaquar/ Havells
Taking down the MCB DB of any type, single phase including disconnection of all circuits complete with MCBs etc.
Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-54, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make - Legrand/ Schneider/ GE
(a) MCB SPN 63 Amps, 240 Volts - 01 No Make - Legrand/ Schneider/ GE
(b) MCB SP 6-32 Amps, 240 Volts. Make - Legrand/ Schneider/ GE
S&F 8 way Double door type having protrection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following :- Make- Havells/ Philips/ Legrand
S & F MCB SPN 40 Amps, 240 Volts, C Series complete all as specified and directed by Engineer in charge. Make Legrand Model No 408620 or its equivalent in Havells / Standard / L&T as approved by GE.
S & F MCB SP 6-32 Amps, 240 Volts, C Series complete all as specified and directed by Engineer in charge. Make Legrand Model No 408595 or its equivalent in Havells / Standard / L&T as approved by GE.
Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way complete all as specified and directed by Engineer in charge. (a) MCB SPN 40Amps 240Volts, 10KA - 1 No ('C' Series) (b) MCB SP 6 - 32Amps 240Volts - 2No ('C' Series) Make : Legrand Model No 408618 or its equivalent in Havells/Philips as approved by GE.
S&F in repairs sheet metal enclosure 2 way without bus bar with MCB complete all as specified and directed by Engineer in charge. (a) Isolator DP 63 Amps Breaking capacity 10 KA. (C series) Make- Havells/ Philips/ Legrand
Supply and fix modular single pole & neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amps complete with modular box & modular plate complete all as specified and directed by Engineer in charge. Make- Havells / Philips/ Legrand
Supply and fix , testing and commissioning of instant type water heater (geyser) vertical type of 06 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 3000 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts connected to existing water and electric connection complete including Hot Water Pipe (for Outgoing Hot water supply ) & Cold Water Pipe (for incoming water supplty to Geyser) complete all as specified and directed by Engineer in charge. Make- Racold Pronto Neo / Bajaj/ Havells / Venus / Jaquar as approved by GE.
Supply and fix RCCB with MCB of 2 Pole, 10 Amps rating with sensitivity of 30 mA suitable for 240 Volts complete all as specified and directed by Engineer in charge. Make- Havells/ Philips/ Legrand
Supply and fix 15 Amps plug top, AC 230 volts, ISI marked complete all as specified and directed by Engineer in charge. Make : Legrand(Arteor) , Havells(Coral) , Goldmedal (WEGA)
Taking down ceiling/exhaust fan, sealing cable end, dismantling blades and removing fan and blades to MES E/M Store all as directed by Engineer in charge.
S&F Ceiling Fan of size 1200mm Sweep, ISI marked, BEE 5 Star rating and alongwith down rod fixed to ceiling and connecting up including provision of flexible 3 core copper cable & testing, smooth functioning at site complete all as specified and directed by Engineer in charge. Make- Ambrose (Gold Mist Wood) in Havells / USHA Striker Galaxy 1200 mm Anti Dust (Bright Gold) / Crompton as approved by GE.
S&F Exhaust fan 225 mm sweep, 1400 RPM plastic ABS body without sound with automatic shutter, AC supply, single phase, 230 volts, 50Hz, complete fixing arrangements on the wall with nuts and bolts and making the good surfaces all as specified and directed at site. Make-Orient / Crompton / Havells / Usha
S&F Wall Mounted fan AC 230V, 250 mm sweep, PVC body with low noise level complete all as specified and directed by Engineer in charge. Make: Havells / Bajaj / Usha
S & F Pr Pump, single phase, AC 230V, suitable for single bathroom including cutting of existing water supply lines, connecting tubings and fitting fixtures required for connection of Pr pump complete all as specified and directed by Engineer in charge. Make: Crompton / Venus / equivalent
S & F LED Strips multicolour RYB, suitable for fixing in ceiling complete all as specified and directed by Engineer in charge. Make: Phillips/Havells/Bajaj
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed by Engineer in charge.
S&F 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 6.0 Sqmm in and including including PVC conduits of suitable size not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 6.0 sqmm (green colour) for earthing complete all as specified and directed by Engineer in charge. Note :- (i) Two runs of 6 Sqmm cable, 1 run of PVC casing & caping and 1 run of 6 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in separate PVC Conduit Make of wire - Polycab / Finolex / Havells Make of Conduit - Pressfit / Precision / Polycab
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4.0 Sqmm in and including PVC conduit not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4.0 sqmm (green colour) for earthing complete all as specified and directed by Engineer in charge. Note :- (i) Two runs of 4 Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in separate PVC Conduit Make of wire - Polycab / Finolex / Havells Make of Conduit - Pressfit / Precision / Polycab
Supply & fixing in repairs LED Flood light fittings 120 Watt capacity in aluminium pressure die cast housing with toughened glass cover, High Power LED, secondary optics, IP 65/66, 10KV SPD, >100lm/Watt including wiring fixture/bracket etc complete all as specified and directed by Engineer in charge. Make ; Jaquar/ Philips/ Havells
Supply & fixing in repairs LED Flood light fittings 75 Watt capacity in aluminium pressure die cast housing with toughened glass cover, High Power LED, secondary optics, IP 65/66, 10KV SPD, >100lm/Watt including wiring fixture/bracket etc complete all as specified & directed. Make : Jaquar/ Philips/ Havells
S & F Environmental Friendly, new generation, energy saving, decorative up down luminaries with wall surface mounting using COB LED of 15Watt as Light Source mounting using COB LED as Light Source complete all as specified and directed by Engineer in charge. Make: CLIO by Havells or its equivalent in Jaquar / Phillips as approved by GE.
S & F Environmental Friendly, new generation, energy saving, decorative spike light using COB LED of 09Watt as Light Source mounting using COB LED as Light Source complete all as specified and directed by Engineer in charge. Make: LYCUS by Havells or its equivalent in Jaquar / Phillips as approved by GE.
Supply and fixing Recess/wall Mounting LED panel, 36 Watt capacity, CRCA housing, white powder coated, with polymer diffuser complete with acessories complete all as specified and directed by Engineer in charge. Make- Havells / Phillips/ Jaquar
Supply, laying, commisssion & testing in repairs XLPE insulated armoured LT cable, 1100 Volts grade with aluminium conductor of size 4 core 16 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed by Engineer in charge. Make - Polycab/ Finolex / Havells
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mr in depth for foundation, laying of UG Electric cable / staying of steel tubular pole etc and getting out in soft and loose soil and making good disturbed surface to match existing complete all as specified and directed by Engineer in charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mr in depth for foundation, laying of UG Electric cable / staying of steel tubular pole, laying of pipes/cables etc and getting out hard/dense soil (road/hard standing etc) and making good disturbed surface to match with existing bituminous topping complete all as specified and directed by Engineer in charge.
Removing the excavated material/soil not exc 50m out of MD land complete all as specified and directed by Engineer in charge.
Returning & filling in, including spreading, levelling, watering & well ramming in layers not exc 25cm as in soil complete all as specified and directed by Engineer in charge.
Supply and laying in repairs high density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 50 mm dia for laying of cable protection complete to walls/trenches/ floor/ ceilings complete all as specified and directed by Engineer in charge. Make : Finolex / Supreme / Prince
M&L for Earthing with galvanised steel earth plate electrode 60x60cmx60mm thick, burried directly in ground (earth pil not less than 2.5mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32x6mm with help of bolts , nuts, check nuts and washers of galvanised iron steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 weatering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
Supply and fix GI tubes Light grade of 40 mm dia complete with all fittings (like; union, tee, bend, elbow, reducer, socket) tobe fixed on wall and ceilings or laid in floors/trenches complete all as specified and directed by Engineer in charge.
Supply and lay in repairs cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6sq mm 2 core laid in duct / along pole/wall etc including making connection complete all as specified and directed by Engineer in charge. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and Repair / Replacement installing, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.00 mm of outer body and inner body 2.00 mm thick CRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:-
SN CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .