Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.6 L+₹2.0 L (5.27%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹39.8 L+₹2.1 L (5.65%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹40.0 L+₹2.3 L (6.24%)Rejected-Finance 397 JASPREET SALUJA INDORE VISHNUPURI ANNEX INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹40.5 L+₹2.8 L (7.45%)Rejected-Finance HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | VARDHMAN INTERNATIONAL L7 | V K Sales and Construction Co L9 | slathia construction works L5 | M/S N.K. POWER SYSTEMS AND PROJECTS L1 | vijay kumar gupta and co L3 | PROACH ASSOCIATES BUILDERS & ENGINEERS L2 | M/S ANMOL TRADING CO L4 | M/s Sahib Construction and engineers L8 | PREM NATH KHAJURIA AND SONS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully Unserviceable Security light 60/90/120/150 watt /Flood Light/ High Mast light fitting from pole/Structure complete all as specified and directed by Engineer-in-charge. | 120 | Each Job | 20 ₹2,400 | 10 ₹1,200 Lowest | 50 ₹6,000 | 20 ₹2,400 | 10 ₹1,200 Lowest | 30 ₹3,600 | 220 ₹26,400 | 50 ₹6,000 | 25 ₹3,000 |
| 2.00 | Refixing the U/S light fitting after visual inspection at complaint cell/power house and replacing the unservicable parts such as Driver,SPD,Connecting wires, nut,bolts/ Screws as per requirement and connecting accesories such cables conductors 2.5 sqmm/4sqmm,drivers, service brackets along with nut bolts etc without any extracost to the contractor by the department complete all as specified and directed by Engineer-in-charge. | 120 | Each Job | 200 ₹24,000 | 60 ₹7,200 | 50 ₹6,000 | 300 ₹36,000 | 10 ₹1,200 Lowest | 30 ₹3,600 | 150 ₹18,000 | 100 ₹12,000 | 30 ₹3,600 |
| 3.00 | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | 400 | RM | 25 ₹10,000 | 42 ₹16,800 | 8 ₹3,200 Lowest | 59 ₹23,600 | 20 ₹8,000 | 12 ₹4,800 | 15 ₹6,000 | 17 ₹6,800 | 14 ₹5,600 |
| 4.00 | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 4 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | 500 | RM | 32 ₹16,000 | 62 ₹31,000 | 10 ₹5,000 Lowest | 79 ₹39,500 | 25 ₹12,500 | 17 ₹8,500 | 17 ₹8,500 | 20 ₹10,000 | 19 ₹9,500 |
| 5.00 | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 6 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | 500 | RM | 37 ₹18,500 | 110 ₹55,000 | 12 ₹6,000 Lowest | 89 ₹44,500 | 30 ₹15,000 | 22 ₹11,000 | 22 ₹11,000 | 30 ₹15,000 | 24 ₹12,000 |
| 6.00 | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 10 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | 400 | RM | 38 ₹15,200 | 172 ₹68,800 | 15 ₹6,000 Lowest | 94 ₹37,600 | 150 ₹60,000 | 28 ₹11,200 | 35 ₹14,000 | 40 ₹16,000 | 36 ₹14,400 |
| 7.00 | S&F in replacement modular box of size 333 x 233 x 120 mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specified and directed by Engineer-in-charge. | 100 | Each | 950 ₹95,000 | 1,200 ₹1,20,000 | 650 ₹65,000 | 610 ₹61,000 | 500 ₹50,000 Lowest | 890 ₹89,000 | 800 ₹80,000 | 600 ₹60,000 | 890 ₹89,000 |
| 8.00 | S&F in replacement MS bracket for street light fittings made out of 40 mm dia GI pipe of medium grade 1.5 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos made out of 32x6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fittings complete all as specified and directed by Engineer-in-charge. | 60 | Each | 300 ₹18,000 | 750 ₹45,000 | 250 ₹15,000 Lowest | 400 ₹24,000 | 300 ₹18,000 | 400 ₹24,000 | 500 ₹30,000 | 250 ₹15,000 Lowest | 520 ₹31,200 |
| 9.00 | S&F in replacement 250 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engineer-in-charge.
Make : Crompton/Bajaj/Philipsor/Wipro | 10 | Each | 5,900 ₹59,000 | 7,100 ₹71,000 | 6,100 ₹61,000 | 7,700 ₹77,000 | 9,000 ₹90,000 | 6,500 ₹65,000 | 7,200 ₹72,000 | 5,000 ₹50,000 Lowest | 9,500 ₹95,000 |
| 10.00 | S&F in replacement 200 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engineer-in-charge.
Make : Crompton/Bajaj/Philipsor/Wipro | 10 | Each | 5,500 ₹55,000 | 6,500 ₹65,000 | 6,000 ₹60,000 | 5,700 ₹57,000 | 9,000 ₹90,000 | 6,100 ₹61,000 | 6,200 ₹62,000 | 4,700 ₹47,000 Lowest | 6,690 ₹66,900 |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
15 May 2026, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur PO-Garhi Pin-182121
Repair/Replacement of LT Security Light/Perimeter Security light of Northern part under GE (Utilities) Udhampur
2026_MES_761873_1
GE/U-27/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹1 L
30 May 2026
24 Apr 2026
18 May 2026
24 Apr 2026
15 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Taking down carefully Unserviceable Security light 60/90/120/150 watt /Flood Light/ High Mast light fitting from pole/Structure complete all as specified and directed by Engineer-in-charge. | - | Each Job | - | - |
| - | Refixing the U/S light fitting after visual inspection at complaint cell/power house and replacing the unservicable parts such as Driver,SPD,Connecting wires, nut,bolts/ Screws as per requirement and connecting accesories such cables conductors 2.5 sqmm/4sqmm,drivers, service brackets along with nut bolts etc without any extracost to the contractor by the department complete all as specified and directed by Engineer-in-charge. | - | Each Job | - | - |
| - | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | - | RM | - | - |
| - | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 4 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | - | RM | - | - |
| - | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 6 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | - | RM | - | - |
| - | Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 10 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specified and directed by Engineer-in-charge.
Make :KEI/Polycab/Havells | - | RM | - | - |
| - | S&F in replacement modular box of size 333 x 233 x 120 mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specified and directed by Engineer-in-charge. | - | Each | - | - |
| - | S&F in replacement MS bracket for street light fittings made out of 40 mm dia GI pipe of medium grade 1.5 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos made out of 32x6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fittings complete all as specified and directed by Engineer-in-charge. | - | Each | - | - |
| - | S&F in replacement 250 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engineer-in-charge.
Make : Crompton/Bajaj/Philipsor/Wipro | - | Each | - | - |
| - | S&F in replacement 200 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed by Engineer-in-charge.
Make : Crompton/Bajaj/Philipsor/Wipro | - | Each | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER27.pdf
Tender Documents • 1.29 MB
BOQ_853406.xls
BOQ • 6.32 MB
Amendmenttodate.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .