| 1.00DAMAGED EQUIPMENTS AT DIFFERENT RECEIVNG STATION DURING FLASH FLOODS OCCURRED DURING THE MONTH OF AUG 2025 IN RESPECT OF STD-III KATHUA. | |||||
| 1.01 | SITC OF 11KV VCB Panel sets (incomer 12 KV, 1250 A,25 KA, 750/375/5-5A and outgoing 12 KV, 1250 A,25 KA, 400/200/5-5A) with vaccum circuit breaker & control panel including cast resin CT,PT,E/F, master Trip Relay &O/C relay(IEC 61850) Mimic diagram, voltmeter, , DLMS compliant with RS-485 port, Annunciation window with annunication relays and other accessories etc as per TS, scope of work & approved drawings along with mandatory spares i.e. O/C + E/F relay, Vaccum Interupter 2000 Amps, master Trip relay etc.(SCADA Compatible) at R/Stations: Paharpur (1+3), Ghagwal (1),challan pranjali (1), Lahri Kudhter (1+2), Hiranagar (1), Basholi (2 Outgoing), Hatlimorh-I (1+2) & Ramkot (1+2) along with Bus Adapter for compatibility with existing Panels at every station.
(Bus Bar should be Copper made).
(Dismanteling of Old and Installation with New) | 18 | No. | 6,00,000 ₹1,08,00,000 Lowest | 6,15,000 ₹1,10,70,000 |
| 1.02 | SITC OF 11KV LA, i.e Gapless surge arrestor 9 KV, 10 KA, LA with polymar housing . Station type for 11 KV Line (3LAs in 1 set) with conventional earthing(4Nos.), Hot dipped galvanized 600mmx600mmx6mm thick plate welded with GI Strips for earthing of size 50mmX6mm for connection of lightening arrestor as per IS2629/85, GI Nuts and bolts,refilled with good earth, charcoal dust, salt, etc inside the Pit as per the direction of site engineer, enhancement material and earth chamber made of brick masonar with RCC slab cover (3LAs in 1 set) at R/Stations: Paharpur (2 Set), Hiranagar (2 Set), Palli (2 Set), Hatlimorh-I (2 Set). (Dismanteling of Old and Installation with New) | 8 | Set | 10,000 ₹80,000 Lowest | 35,000 ₹2,80,000 |
| 1.03 | SITC OF 11KV XPLE 3 core 95 sq.mm , round wire armoured cable, FRLS confirming to IS 7098 ( part-II)- 1985 standards at R/Stations: Sherpur (30 Mtr), Paharpur (30 Mtr), Channi (40 Mtr) for Auxillary Transformers. (Dismanteling of Old and Installation with New) | 100 | Mtr | 2,000 ₹2,00,000 | 1,000 ₹1,00,000 Lowest |
| 1.04 | SITC OF 11KV XPLE 3 core 300 sq.mm , round wire armoured cable, FRLS confirming to IS 7098 ( part-II)- 1985 standards at R/Stations: Ghagwal (100 Mtr), Paharpur (120 Mtr), Rajpura (70 Mtr), Hiranagar-I (140 Mtr), Palli (70 Mtr), Hatlimorh-I (70 Mtr), Marheen (70 Mtr) & Phinter (70 Mtr). (Dismanteling of Old and Installation with New) | 710 | Mtr | 3,200 ₹22,72,000 | 2,500 ₹17,75,000 Lowest |
| 1.05 | SITC OF 11KV XPLE Single core 630 sq.mm, round wire armoured cable, FRLS confirming to IS 7098 ( part-II)- 1985 standards at R/Stations: Rajpura (150 Mtr) & Hiranagar-I (150 Mtr). (Dismanteling of Old and Installation with New) | 300 | Mtr | 4,500 ₹13,50,000 | 1,500 ₹4,50,000 Lowest |
| 1.06 | SITC OF 11 KV Cable Kits Three Core, 95 mm2 ‐Outdoor (CPRI tested) with bar coding printed on it | 3 | Set | 4,500 ₹13,500 Lowest | 4,700 ₹14,100 |
| 1.07 | SITC OF 11 KV Cable Kits Three Core, 95 mm2 ‐Indoor (CPRI tested) with bar coding printed on it | 3 | Set | 4,500 ₹13,500 | 4,300 ₹12,900 Lowest |
| 1.08 | SITC OF 11 KV Cable Kits Three Core, 300 mm2 ‐Outdoor (CPRI tested) with bar coding printed on it | 10 | Set | 4,500 ₹45,000 Lowest | 4,700 ₹47,000 |
| 1.09 | SITC OF 11 KV Cable Kits Three Core, 300 mm2 ‐Indoor (CPRI tested) with bar coding printed on it | 10 | Set | 4,500 ₹45,000 | 4,300 ₹43,000 Lowest |
Tender Value
₹2.2 Cr
EMD Value
₹4.3 L
Closing Date
17 Jun 2026, 2:00 pmClosed
Executive Engineer
Executive Engineer STD JPDCL Kathua Hatli Morh
Supply, erection, testing and commissioning for damaged equipments at different receiving station during flash floods occurred during the month of aug 2025 in respect of STD-III Kathua
2026_PDD_308379_1
STD-III/e-NIT/2026-27/1 Dated 21.04.2026
Open Tender
Electrical Works
Turn-key
120 days
Kathua/Hiranagar/Billawar
8 documents required · 8 mandatory
₹5,000
Executive Engineer STD Kathua
₹4.3 L
Executive Engineer STD JPDCL Kathua
25 Jun 2026
22 Apr 2026
18 Jun 2026
22 Apr 2026
17 Jun 2026
22 Apr 2026
22 Apr 2026 - 25 Apr 2026
27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | DAMAGED EQUIPMENTS AT DIFFERENT RECEIVNG STATION DURING FLASH FLOODS OCCURRED DURING THE MONTH OF AUG 2025 IN RESPECT OF STD-III KATHUA. | - | - | - | - |
| 1.01 | SITC OF 11KV VCB Panel sets (incomer 12 KV, 1250 A,25 KA, 750/375/5-5A and outgoing 12 KV, 1250 A,25 KA, 400/200/5-5A) with vaccum circuit breaker & control panel including cast resin CT,PT,E/F, master Trip Relay &O/C relay(IEC 61850) Mimic diagram, voltmeter, , DLMS compliant with RS-485 port, Annunciation window with annunication relays and other accessories etc as per TS, scope of work & approved drawings along with mandatory spares i.e. O/C + E/F relay, Vaccum Interupter 2000 Amps, master Trip relay etc.(SCADA Compatible) at R/Stations: Paharpur (1+3), Ghagwal (1),challan pranjali (1), Lahri Kudhter (1+2), Hiranagar (1), Basholi (2 Outgoing), Hatlimorh-I (1+2) & Ramkot (1+2) along with Bus Adapter for compatibility with existing Panels at every station.
(Bus Bar should be Copper made).
(Dismanteling of Old and Installation with New) | - | No. | - | - |
| - | SITC OF 11KV LA, i.e Gapless surge arrestor 9 KV, 10 KA, LA with polymar housing . Station type for 11 KV Line (3LAs in 1 set) with conventional earthing(4Nos.), Hot dipped galvanized 600mmx600mmx6mm thick plate welded with GI Strips for earthing of size 50mmX6mm for connection of lightening arrestor as per IS2629/85, GI Nuts and bolts,refilled with good earth, charcoal dust, salt, etc inside the Pit as per the direction of site engineer, enhancement material and earth chamber made of brick masonar with RCC slab cover (3LAs in 1 set) at R/Stations: Paharpur (2 Set), Hiranagar (2 Set), Palli (2 Set), Hatlimorh-I (2 Set). (Dismanteling of Old and Installation with New) | - | Set | - | - |
| 1.03 | SITC OF 11KV XPLE 3 core 95 sq.mm , round wire armoured cable, FRLS confirming to IS 7098 ( part-II)- 1985 standards at R/Stations: Sherpur (30 Mtr), Paharpur (30 Mtr), Channi (40 Mtr) for Auxillary Transformers. (Dismanteling of Old and Installation with New) | - | Mtr | - | - |
| - | SITC OF 11KV XPLE 3 core 300 sq.mm , round wire armoured cable, FRLS confirming to IS 7098 ( part-II)- 1985 standards at R/Stations: Ghagwal (100 Mtr), Paharpur (120 Mtr), Rajpura (70 Mtr), Hiranagar-I (140 Mtr), Palli (70 Mtr), Hatlimorh-I (70 Mtr), Marheen (70 Mtr) & Phinter (70 Mtr). (Dismanteling of Old and Installation with New) | - | Mtr | - | - |
| 1.05 | SITC OF 11KV XPLE Single core 630 sq.mm, round wire armoured cable, FRLS confirming to IS 7098 ( part-II)- 1985 standards at R/Stations: Rajpura (150 Mtr) & Hiranagar-I (150 Mtr). (Dismanteling of Old and Installation with New) | - | Mtr | - | - |
| - | SITC OF 11 KV Cable Kits Three Core, 95 mm2 ‐Outdoor (CPRI tested) with bar coding printed on it | - | Set | - | - |
| 1.07 | SITC OF 11 KV Cable Kits Three Core, 95 mm2 ‐Indoor (CPRI tested) with bar coding printed on it | - | Set | - | - |
| - | SITC OF 11 KV Cable Kits Three Core, 300 mm2 ‐Outdoor (CPRI tested) with bar coding printed on it | - | Set | - | - |
| 1.09 | SITC OF 11 KV Cable Kits Three Core, 300 mm2 ‐Indoor (CPRI tested) with bar coding printed on it | - | Set | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.83 MB
BOQ_999421.xls
BOQ • 0.30 MB
SBD.pdf
Tender Documents • 2.17 MB
Extensionotice-III.pdf
PDF • 0.12 MB
Extensionnotice2.pdf
PDF • 0.13 MB
extensionnotice1.pdf
PDF • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .