Staff Officer -1
ARTC and S shokhuvi
ARTC/DGAR/DPU/33
2022_ARMHA_723261_1
ARTC/DGAR/DPU/33 of 2022-23
Open Tender
Electrical Works
Works
180 days
Shokhuvi
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Yes
DIG ARTC and S
₹34,000
Yes
30 Dec 2022
14 Nov 2022
29 Nov 2022
14 Nov 2022
28 Nov 2022
14 Nov 2022
14 Nov 2022 - 28 Nov 2022
Daily maintenance and operation of the water pumping and treatment plants with one operator cum technician in each shift of three shift for each installation from 0600 hrs to next day 0600hrs (in three shifts per day consisting of 08 hrs per shift ) including sunday and holiday as specified and directed by the Engineer-in-Charge (Note: term daily operation includes minor maintenance and like adjustment of eqpt, cleaning , insert gland packing and also hourly ready and recording of each plant, log sheet will be maintained by the contractor in standard performa to make record in consultation with Engr-in-charge and periodical maint includes back washing of pressure filter/IRP daily or as required including maint of pumping sets (centrifugal/monoblock) like replacement of gland packing , bearing etc replacement of pumping set . Feeding of chemical bleeching and alum etc as per direction of Engr, cleaning of aieration tank storage sump and overhead storage tank as required at treatment & distribution/supply pump house.
Daily maintenance and operation of the DG sets, switch gears and other electrical eqpts at pump house and Generator room with one operator in each shift of three shift for each installation from 0600hrs to next day 0600 hrs (in two shifts per day consisting of 08 hrs per shift) including sunday and holiday to keep continuous electric supply and repolacement of all defective spare parts as specified and directed by the Engr-in-Charge) Note : Term daily operation includes minor maintenance and like adjustment of eqpt, cleaning of batteries terminals, self dynamo and also hpourly reading and recording of each plant including servicing minor with replacement of log sheet will be maintained by the contractor in standard performa to make records in consultation with Engr-in-Charge (ii) Fuel for lubricants will be issued under Sch 'B" store free for feeding as required. Spares will be measured and paid separetely under appropriate items.
S&F in repair 100 mm bore sluice valve heavy duty both ends flanged and drilled type nominal pressured rating PN-1, conformed to IS 780 of 1980 complete with cast iron body bonnet wedge stuffing box galvanished thrust plate, spindle made of high tensile stainless steel cast iron hand operated wheel with cap top nuts, bolts. washes wedge nut body seal ring and wedge facing run lead tin braise, compressed fibre bolts and nuts, gland packing of superior quality including 6mm thick rubber gasket joint compelet all as specifed and directed by Engineer-in-Charge. MAKE: Leader , Kirloskar & Upadhyay
Opening of 100 mm bore sluice valve by opening up for repair & detection of fault , cleaning of serviceable parts, replacement of unserviceable or worn out parts such as glands, gland packing, gaskets, facing the gate & valve seat, replacement of nut bolts, re-assembling and fixing in existing position & after testing complete all as specifed and directed by Engineer-in-Charge. Note :- Necessary arrangements for regulating the water supply in line for the purpose of repair shall be made by contractor at his own expenses and worn/ unserviceable spare parts to be replaced with new spare parts, if required for smooth functionning shall be included in item of BoQ & unit rate qouted by the contractor inclusive for all this purpose & not any claim entrtained on this account at later stage.
M & L for construction of brick masonary valve pit chamber of size 600 mmx 600 mm x 600 mm (internal dimension) including necessary excavation and earthwork, PCC 1:4:8, brick work in cement motar 1:4, 12 mm thick rendering in cement mortar 1:4 on internal surface of valve pit and mild steel sheet cover 05mm thick and mild steel angle iron frame size 50mm x 50 mm x 06mm around of valve pit, locking arrangement with pad lock of size 50 mm brass, 6 leavers and key( make ; Godrej) complete including two coat of synthetic enamel over a coat red oxide primer on steel surface with preparation of surface and including dismantling of existing valve pit complete all as specified & directed.
M&L in repair for joint with rubber or fibre board gasket including necessary fixing accessories such as nut, bolt & washer, etc. required for completion for 80mm bore flanged ends pipe complete all as specified & directed.
M&L in repair for joint with rubber or fibre board gasket including necessary fixing accessories such as nut, bolt & washer, etc. required for completion for 100mm bore flanged ends pipe complete all as specified & directed.
Disconnecting the all electric & mechanic connection from pump with electric motor 3 phase, 415 volts, 50 c/s any capacity of electric motor / submersible pump of any make from the set, rewinding the motor with PVC insulated copper winding wire of existing gauge and size including all other winding material such as leatheriest paper, tapes, sleeves etc and suitable size bearing , if required including and testing complete for smooth functioning and satisfied by Engineer-in-Charge & reassembling and re-fixing with true alignment and testing and commissioning complete all as specified & directed by Engineer-in-Charge.
Supply only stainless steel bushes each set suitable for 5 HP to20 HP submersible motor complete
Supply only 'O' ring kit and oil seal kit suitable for 5 HP to 20 HP complete
Supply only thrust bearing excel carbon suitable for 5 HP to 20HP complete.
Supply only thrust bearing plate suitable for 5 HP to 20HP complete
Supply only sand guard suitable for 5 HP to 20HP complete.
Supply only water seal suitable for 5 HP to 20HP complete
Supply only gun metal bush of pump shaft suitable for 5 to 20 HP complete.
Supply only impeller bush of gun metal suitable for 5 to 20 HP complete.
Supply only neck ring of impeller as per existing size suitable for 5 to 20 HP including necessary lathe work complete all as specified and directed by Engineer-in-Charge.
S&F for replacement jointing the submersible cable by means of jointing material & making the leak proof jointing complete all as specified and directed by Engineer-in-Charge.
S & F Iin repair contactor 3 pole, ML4 (2NO + 2 NC) current rating 70Amp Make- L&T
S & F in replacement , connecting, testing and commissioning fully Automatic Star Delta Starter in sheet steel enclosure type MN 16F with single phase protection suitable for 25HP, 3 Phase, 415 volts, 50 HZ, having all standered accessories complete all as specified and directed. MAKE: Shneider/ L&T/ Legrand/ Standard.
Taking up the unserviceable submersible pump with motor from the bore well , transporting to work shop for repair, disconnecting the all electric & mechanic connection from pump with electric motor 3 phase, 415 volts, 50 c/s of capacity 10 HP to 20 of electric motor / submersible pump of any make from the set, rewinding the statar coil with super enamelled copper winding wire of existing gauge and size including all other winding material such as leatheriest paper, tapes, sleeves etc, Bush,'O' ring, Sand guard, water seal and suitable size bearing if required including varnishing, heating, drying and testing complete for smooth functioning and satisfied by Engineer-in-Charge & reassembling and re-fixing with true alignment and testing and commissioning complete all as specified & directed by Engineer-in-Charge.
Disconnecting the electric connection of unserviceable monoblock submersible pump with motor , transporting to work shop for repair, disconnecting the all electric & mechanic connection from pump with electric motor 3 phase, 415 volts, 50 c/s of capacity 7.5/15 HP of electric motor / submersible pump of any make from the set, rewinding the motor with super enamelled copper winding wire of existing gauge and size including all other winding material such as leatheriest paper, tapes, sleeves etc, Bush,'O' ring, Sand guard, water seal and suitable size bearing if required including varnishing, heating, drying and also repair/ replacement of spair parts of pump such as bowal busg, gun metal bush, neck ring and testing complete for smooth functioning and satisfied by Engineer-in-Charge & reassembling and re-fixing with true alignment and testing and commissioning complete all as specified & directed by Engineer-in-Charge.
S&F in repair submersible cable heavy duty PVC insulated and sheathed 16 sqmm size 3 core conductor flat fully water proof 1100 volt grade complete all as specified and directed. Make :- HAVELLS/FINOLEX/PLAZA
Supply only Asbestos rope of 12mm /20mm wrapped over the exhaust pipe of DG SET any capacity as per existing make, model & size.
S&F in replacement autometic voltage regulator suitable for 15 KVA to 400 KVA DG Set complete all as specified and directed.Make- Kirlosker/ Ashok leyland/ C&G/ Cumins
Supply only for filling new coolent in sealed container complete all as specified and directed. NOTES :-Coolent shall be collected in sealed container . Cost of filling of coolent in included in unit quoted rates in here in - before )
S & F in replacement OFF load change over switch in sheet metal enclosure, 415 Volts, 4 pole 100 Amps capacity with side handle operation conforming conforming to ISIEC 60947-1&3 complete all as specified and directed . Make : Havells Cat No- IHCFFE0100 or equivalent in C&S / L&T/ Standard.
S&F in replacement of lead accumulator containing with electroctrolyte of capacity 12 Volts ,150 AH suitable for 63 to 125 KVA DG sets all as specified and as directed ( Make : Exide /Amaron )
Cleaning/descaling of deisel fuel tank of DG Set and writing date of cleaning complete all as specified & directed.
M/s. Surya Construction
M/S MAITRA ENTERPRISE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .