| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹13.9 L+₹62,135 (4.68%)Rejected-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹15.0 L+₹1.7 L (13.0%)Rejected-AOC | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | Rejected-Technical 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY |
Tender Value
₹14.6 L
EMD Value
₹29,100
Closing Date
20 Oct 2022, 6:00 pmClosed
GE E/M RR HOSPITAL
GE E/M RR HOSPITAL, RAO TULA RAM MARG, DELHI CANTT-10
CA No GE/H-18/2022-23 REPAIR/REPLACEMENT OF FITTING/FIXTURE OTHER THAN HOSP BLDG AT AHRR UNDER GE E/M RR HOSPITAL DELHI CANTT-10
2022_MES_553661_1
GE/H-18/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M RR HOSPITAL DELHI CANTT-10
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE E/M RR HOSPITAL
₹29,100
Yes
15 Dec 2022
22 Sept 2022
22 Oct 2022
22 Sept 2022
20 Oct 2022
6 Oct 2022
Amount
S&F in replacement tube light retrofit rod 20 watt (CW), 4 feet long with high efficient LEDs available in clear & milky diffuser, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F in replacement LED tube light fitting 20 watt (CW), 4 feet long in extruded aluminium batten with high efficient LEDs available in milky diffuser, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F in replacement tube light fitting 10 watt (CW), 2 feet long in extruded aluminium batten with high efficient LEDs available in clear & milky diffuser, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F in replacement of recessed mounting LED light fitting (flat panel) 2'x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.
S&F in replacement recess mounted LED light fitting (flat panel) 1' x 4' in size of 36 watt(CW) with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F in replacement surface mounted LED light fitting (flat panel) 1' x 4' in size of 36 watt(CW) with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed.
S&F in replacement surface/ recessed mounted LED light fitting 15 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.
S&F in replacement surface/ recessed mounted LED light fitting 9 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.
S&F in replacement of recessed mounting LED light fitting (flat panel) 1'X1' with high efficeint LEDs and Glare free and opal diffuser of 18 watt (CW) including fixing accessories likes strip clips etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.
S&F in replacement of surface mounting LED light fitting (flat panel) 1'X1' with high efficeint LEDs and Glare free and opal diffuser of 18 watt (CW) including fixing accessories likes strip clips etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.
Supply and fix in replacement of energy efficient wall/ceiling mounted LED bulk head light fitting 10 watt, IP-66, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed.
Supply and fix in replacement Building security light with high efficient high power LED street light 30 watt with lens with pressure die cast aluminium housing and enclosed with toghened glass. PF>0.9, impact resistance of IK07 and Voltage rated 220V to 240V etc complete all as specified and directed.
Supply and fix in replacement service bracket for mounting on wall of the bldg of suitable size light grade GI pipe 1.2 Mtr long with fixing accessories likes as clamps, fastener, nuts, bolts etc complete all as specified and directed.
Supply and fix in repair copper twin twisted flexible wire of size 23/76 complete all as specified and directed.
Supply and fix in replacement comfort bed light fitting above patient bed for Hospitals in extruded aluminium housing with PMMA diffuser having system Wattage of 31 Watts and having personalised bidirectional up & down light for pleasant and smoothing light experience including 03 Nos switches for each light complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surfaces of wall, floor etc. complete all as specified and directed.
Taking down submain wiring of any size complete all as specified and directed.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in & including PVC surface casing and caping including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including MS sunken box of suitable size for light/fan/bell point, and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per srl item No.18 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No.18 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item No.18 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in existing conduit including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including MS sunken box of suitable size for acomodating light/fan/bell switches, sockets & regulators, and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as abblicable will be included in quoted rates.
All as per srl item No. 22 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No. 22 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item no. 22 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point on Independent board.
Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 4.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified and directed. Note : 1. The two run of 4.0 Sqmm wire, one run of 4.0 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 26 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire.
Supply & fixing of Modular switch 6 Amp, 1 way, 1 module size complete all as specified and directed.
Supply and fixing of Modular switch 16 Amp, 1 way, 1 module size complete all as specified and directed.
Supply and fixing of Modular socket 6 Amp, 5 pin, 2 module size complete all as specified and directed.
Supply and fixing of Modular socket 6/16 Amp, 3 pin, 2 module size complete all as specified and directed.
Supply and fixing of Modular Fan regulator step type, 100 watts, 1 Module size complete all as specified and directed.
Supply and fixing of Ceiling rose, PVC polycarbonate body isolated body, 3 terminal, 240 volts, 5 Amps complete all as specified and directed.
S&F in repair sheet metal enclosure distribution board, 12 way single pole and neutral, AC, 240 volts, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per srl item no. 34 here-in-before but 8 way.
S&F in repair MCB SPN, AC, 240 volts of 40-63 Amps capacity "B" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed.
S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity "B" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
GLIBS CONSTRUCTION
ACR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .