| 1 | L1₹27.9 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Being Lowest and reasonable | |
| 2 | L2₹30.5 L+₹1.3 L (4.58%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹35.0 L+₹5.8 L (20.0%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹36.0 L+₹6.9 L (23.5%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹37.4 L+₹8.3 L (28.5%)Rejected-Finance NO 228 3RD CROSS HRBR 3RD BLOCK NEAR JALVAYU VIHAR WEST GATE BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Apr 2024, 6:00 pmClosed
GARRISON ENGINEER I R nd D WEST BANGALORE
GARRISON ENGINEER I R nd D WEST BANGALORE, CV RAMAN NAGAR, BANGALORE-93
REPAIR AND REPLACEMENT OF LT UG CABLE SERVICE WIRE MCCB DB MCB DB AND CONNECTED WORKS AT PHASE I AND FAR FLUNG AREA UNDER GE I R AN D WEST BANGALORE
2024_MES_643824_1
GE(I)/R ND D/BAN/TOKEN/01 OF 2024-25 8256/E8
Open Tender
Civil Works
Item Rate
270 days
GARRISON ENGINEER I R nd D WEST BANGALORE
CLASS AND CATEGORY AS PER NIT
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I R nd D WEST BANGALORE
₹90,000
26 Jun 2024
23 Mar 2024
19 Apr 2024
23 Mar 2024
13 Apr 2024
7 Apr 2024
23 Mar 2024 - 6 Apr 2024
Amount
Excavation in trenches not exc. 1.5 m wide, not exc. 1.5 m in depth; for laying of cables etc not exc. 10 Sqm on plan and getting out , trimming sides, forming bottom surface to required level complete in hard/dense soil all as specified and as directed.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick as in soils all as specified and as directed.
Removing of excavated soil to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
M&L for providing of new sub class 'B' bricks, old size 230x115x75 mm, well burnt ,laid flat, dry for protection of under ground cable complete all as specified and directed.
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
Taking out from trenches or wall/ pole or pipe, cable LT 1100 volts, grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size upto 25 Sqmm , any core , for rectification of faults or replacement. Seggregating serviceable cable and unserviceable lenght by meggering or any other suitable recommended method. Removing unserviceable from site and keeping aside serviceable for reuse at same location or any other location under AGE E/M (West) all as per requirement at site and directed. (Earth work will be measured and paid separately under respective item).
All as per Srl Item 6 here in above but of size 35 Sqmm to 95 Sqmm
All as per Srl Item 6 here in above but of size 120 Sqmm to 185 Sqmm
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 Volts grade heavy duty, armoured with aluminium conductor of any size upto 25 Sqmm any core. (Serviceable cables retrieved from item above will be used).
All as per Srl Item 9 here in above but of size 35 Sqmm to 95 Sqmm
All as per Srl Item 9 here in above but of size 120 Sqmm to 185 Sqmm NOTE : Cables under item 9 to 11 will be issued under Schedule 'B' free for fixing only
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of any size 10x 4 Sqmm any core.
All as per Srl Item 12 here in above but of size 35x 3.5 sqmm
All as per Srl Item 12 here in above but of size 50x 3.5 sqmm
All as per Srl Item 12 here in above but of size 70x 3.5 sqmm
All as per Srl Item 12 here in above but of size 95x 3.5 sqmm
All as per Srl Item 12 here in above but of size 120x 3.5 sqmm
All as per Srl Item 12 here in above but of size 150x 3.5 sqmm
All as per Srl Item 12 here in above but of size 185x 3.5 sqmm
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ core core with working voltage 1100 volts make: Denson/ M Seal.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 sqmm 3½ core core with working voltage 1100 volts make: Denson/ M Seal.
M&L for cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 300 sqmm 3½ core core with working voltage 1100 volts make: Denson/ M Seal.
M&L for cable straight through joint kit, heat shrinkable type suitable for XLPE/ PVC cables of size up to 50 to 70 Sqmm 3½ core core with working voltage 1100 volts make: Denson/ M Seal.
M&L for cable straight through joint kit, heat shrinkable type suitable for XLPE/ PVC cables of size 70 to 95 Sqmm 3½ core core with working voltage 1100 volts make: Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 Sqmm3½ core core with working voltage 1100 volts make: Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 95 Sqmm to 120 Sqmm3½ core core with working voltage 1100 volts make: Denson/ M Seal.
Material and labour for detection of any type of fault in LT/HT underground Line of any size and core. (laid in soil at plane area or forest area) with the help of LT/HT Meggar. Seggregation of faulty span by meggering and making span serviceable by repair of cable or replacement of cable. Note : Item No 6 to 8 1. Detection of one fault in faulty span will be measured as Each Job. 2. Earth work and taking out will be measured seperately. 3. Material for repair and replacement will be measured saperately.
PCC 1:3:6 type C1 using 20mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and as directed.
PCC 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc.
Scraping of old paint from the steel tubular pole 9 metres height with out removing accessories and preparation of surfaces for repainting and repainting the pole with one coat of alternative Black and Yellow strips of 30 cm each upto 1.5 mtr height using synthetic enamell paint . Marking the pole No with black enamel paint over yellow circle of dia 100mm . Repainting the remaining pole and iron parts i.e U clamps, channels etc above 1.5 mtr height by applying one coat of aluminium paint all as required at site or directed.
Repair and replacement of cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of primer.
Supply and fix sheet moulding compound (SMC) chequered plates 2.5mm thick for trench covers, cut to size all as required at site or directed. Make Sintex/Denson
Supply and laying in reapirs GI tubing light grade 40 mm bore for cable protection fixed on wall/pole/laid in trenches complete all as specified and as directed
Supply and laying in reapirs GI tubing light grade 50 mm bore for cable protection fixed on wall/pole/laid in trenches complete all as specified and as directed
Supply and laying in reapirs GI tubing light grade 80 mm bore for cable protection fixed on wall/pole/laid in trenches including taking out old ones complete all as specified and as directed
Supply and fixing in replacement MCCB 4 pole 415 Volts, 400 Amps, adjustable type with breaking capacity 36 KA including taking out old unserviceable MCCB complete all as specified and as directed. Make : Indo Asian /L&T/Standard/ Legrand / C&S
Supply and fixing in replacement MCCB 4 pole 415 Volts, 300 Amps with breaking capacity 36 KA including taking out old unserviceable MCCB complete all as specified and as directed Make : Indo Asian /L&T/Standard/ Legrand / C&S
Supply and fixing in replacement MCCB 4 pole 415 Volts, 250 Amps with breaking capacity 36 KA including taking out old unserviceable MCCB complete all as specified and as directed Make : Indo Asian /L&T/Standard/ Legrand / C&S
Supply and fixing in replacement MCCB 4 pole 415 Volts, 200 Amps with breaking capacity 36 KA including taking out old unserviceable MCCB complete all as specified and as directed Make : Indo Asian /L&T/Standard/ Legrand / C&S
Supply and fixing in replacement MCCB 4 pole 415 Volts, 160 Amps with breaking capacity 16 KA including taking out old unserviceable MCCB complete all as specified and as directed Make : Indo Asian /L&T/Standard/ Legrand / C&S
Supply and fixing in replacement MCCB 4 pole 415 Volts, 25 to 100 Amps with breaking capacity 16 KA including taking out old unserviceable MCCB complete all as specified and as directed Make : Indo Asian /L&T/Standard/ Legrand / C&S
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6 mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion with and including 20 mm bore light grade GI protection pipe 7.5 meters long for earth including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrange,ent with funnel wire, common salt and charcoal filling, necessary excavation and earth work in any type of soil complete all as specified.
All as per item No 42 here in above but using galvanised iron strip 32×6mm as earthing lead
S&F in replacement Double Door vertical type DB ,Triple poleand Neutral, 4 Way 415 Volt suitable for MCCB up to 250 Amps as incomer with suitable manufactureres rated Bus Bar, IP 43 protection, isolated neutral bus bar, mechanical impact strength IK 09, door earthing, insulated busbar assembly including necessary dummy plate complete all as required Note : MCCB shall be measured and paid separately.
Sahara Engineers
Pacific Enterprises
RRK PROJECTS
S SELVALAKSHMI ENGINEER AND CONTRACTOR
M/S - KRUPA ELECTRICALS
Solar Electricals and Electronics
GKR and CO
Meghana and Gowda Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .