Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC | ₹30.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹32.5 LRejected-AOC VPO KAIRON TEHSIL PATTI DISTRICT TARN TARAN | TARN TARAN | PUNJAB | ₹32.5 L | L2 | Rejected-AOC L2 |
Tender Value
₹36.2 L
EMD Value
₹72,345
Closing Date
2 Mar 2026, 1:00 pmClosed
EE_ConstructionDivisionNo1PWD_TarnTaran_atAmritsar
EE_ConstructionDivisionNo1PWD_TarnTaran_atAmritsar
New construction of Civil Veterinary Dispensary at Village Behla District Tarn Taran
2026_CEPW_160921_1
30/3 dt. 16.2.2026
Open Tender
Civil Works - Buildings
120 days
Village Behla Districtt Tarn Taran
Please refer Tender documents.
11 documents required · 11 mandatory
₹5,000
₹72,345
Yes
11 Mar 2026
18 Feb 2026
2 Mar 2026
18 Feb 2026
2 Mar 2026
18 Feb 2026
CIVIL & Public Health WORK
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers withcompaction including disposal of all surplus soil as directed within lead of 30 metres
Cement concrete 1:4:8 with brick balast 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Dressed or moulded one brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified
12.5 mm thick cement plaster 1:4
20mm thick cement plaster 1:4 in two coat work
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge.
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete.Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Doors and windows frame of size 161mm x 60mm with 40 mm wide double rebate weighing 4.05 kg per meter.
Kiln seasoned Hollock wood doors shutter with 12mm thick phenol Bonded BWP ply ISI Marked anchor, Kit ply, Nova Teak, National Or equivalent including Hinges, Screws, Shocks Cleats, Stops and Cords etc. complete fixed in position (Single Leaf).
Wire gauge Hollock wood door shutter without springs housed in chowkhat
Supply & Fixing of Window frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS 513) with zinc of 20gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 1216 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respects as per drawing, design, specification & entire stasfication of Enginner-in-Charge. a (a) Windows Outer frame of size72x55mm and central mullion 72 mm x 50mm with Double rebate
Supply & Fixing of Window shutter consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS: 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with poyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position fixed in position by means of screws , complete In all respects as per drawing, design, specification & entire stasfication of Enginner-in-Charge.Glazed Windows shutter Section 47mm x 20mm(without glass)
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Cost of aluminum fittings complete for doors, windows such as tower bolts,handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area up to 0.50 sqm
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
Iron grated doors, including pintle hinges & arrangements.
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. II (size of door 701mm to 850mm)
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-inCharge.
Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Providing & Installing 1 No. 160 mm o/d PVC straight TUBEWELL by drilling 200mm dia wtih Hand Boring up to depth of 110 m BGL, in all kinds of soil including the cost of consumable stores, fuel oil and transportation of drilling machine to the site of the proposed bore, complete in all respect
Providing, fixing, testing & commissioning (2 BHP) Submersible machinery with pump, Cable, Column pipe & Starter .etc, reputed make complete in all respects.
providing laying , jointing fixing and testing ISI marked PVC pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.
Providing fixing and jointing ISI marked gun-metal peet valves (heavey pattren ) as pewr IS 778 with hand wheels, on G.I. pipe lines laid in the ground of inside building including all carriages complete.
20mm i/d gun metal peet valve heavy pattren.
25mm i/d gun metal peet valve heavy pattren.
32mm i/d gun metal peet valve heavy pattren.
40mm i/d gun metal peet valve heavy pattren.
Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design.
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
Providing and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS-13592 including cutting, jointing, wastage, but excluding cost of lead jointing.
110mm i/d SWR UPVC pipe lines laid complete
70mm i/d SWR UPVC pipe lines laid complete
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing jet spray with 2'-6" long PVC pipe.
With C.P. Brass nut
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap complete in all respect.
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock without flange
Providing & fixing in position C.I gully trap cover weighing approximately 7.26 kg and frame for gully trap camber clear opening size 300mm x 300mm and outside size 330mmx330mm including painting the exposed surface with 3 coats of black bit mastic superior paint of approved make (to the approval of Engineer-in charge).
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
(a) M.S. Holder bats clamps for 100mm i/d H.C.I. pipes
Providing & Fixing in position H.C.I. specials for soil waste vent or anti siphonage pipes to ISI specifications (IS:1729) of approved make (to the approval of Engineer-In-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
P Trap/Floor Trap 75mm x 75mm
Providing & Fixing in position H.C.I. specials for soil waste vent or anti siphonage pipes to ISI specifications (IS:1729) of approved make (to the approval of Engineer-In-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining
For 110mm o/d pipes
Vent Cowls
Single Tee With Door
Single Y-Junction
Coupler
P Trap/Floor Trap 110mm x 110mm
Providing & Fixing in position H.C.I. specials for soil waste vent or anti siphonage pipes to ISI specifications (IS:1729) of approved make (to the approval of Engineer-In-Charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
P Trap/Floor Trap 75mm x 75mm
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks (1000+1000=2000)
Construction of Septic Tank size 5.00 Mtr x 3Mtr. Internal size with 2.5 Mtr. Internal depth in brick masonary, 4 no. chambers medium duty man hole cover complete as per drawing/specification andto the entire satisfaction of Engineer-in-charge
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement concrete 1:8:16 with 40 mm gauge stone ballast. using concrete mixing volumetric type
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
12.5mm thick cement plaster 1:5.
20 mm thick cement plaster 1:5 in two coats work.
Cement rendering on plaster 1mm thick
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Construction of Boundry wall
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
20mm thick cement plaster 1:5 in two coat work
Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Total of Civil and Public Health Work
Electrical Services
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point (With fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indicator and 2Nos. blanking plate (Modular accessories).
SURFACE TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring TV socket, Telephone socket and Networking socket points on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate etc., & including the cost of above material and other petty material with necessary connections etc.:-
Wiring Telephone socket point RJ11 (one module)
Wiring Networking socket point RJ45 (one module)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1sq.mm (Un-sheathed)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Overall size 16sq.mm (Un-sheathed)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- PVC Flexible Pipe 25mm dia.
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 14Metre in length)
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. Additional length G.I. rope 7/12 S.W.G. (7/2.80mm dia.) in 20mm dia. G.I. pipe (On Surface)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 3Nos. shrouded neutral bars, 3Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB's as incomer, DP/RCBO's/RCCB's as sub incomer and SP MCB's as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- TP&N Double Door Phase Segregated Distribution Board 6 way each
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- Bus Bar Chamber 63amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per |5/1=C standards) waltage of each low power LED less than 1 watt input AC frequency 50 Hz = 3 % With 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (481) suitable for 230 V single phase with double ball beanng. copper wound, full aluminium body 3Nos of blades white in colour The mounting type is down rod mount The product should possess a minimum air delervery of 210 CMM (approx) The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos of speeds The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor bladeset, down rod, conopy sel shackle kit, twisted wire etc, including erection & testing of ceiling fan having connection with PVC insulated PVC sneathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge al site.
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of LED Flood Light 50 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty Including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Total of Civil and Public Health Work
Total of Electrical Work
Grand Total (Civil work + Public Health Work + Electrical Work)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
SBD-compressed.pdf
Tender Documents • 19.68 MB
BOQ_326500.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid