Provision of Separate CB (Circuit Breaker) for sectioning of sidings in Bhusawal Division. (PC-BD & BSL-KNW)
BSL_ELECT_TRD_40_2026
BSL_ELECT_TRD_40_2026
Open
Works - General
12 Months
Jalgaon, Maharashtra
₹0
₹9.2 L
16 Jul 2026
16 Jul 2026
28 Jul 2026
A-TRD estimate for Provision of separate CB(Circuit Breaker) for sidings
Preparation of drawing and Design of FP, TSS and Switching station.
Cement concrete for foundation & plinth in other than hard soil & rock.
Cement concrete for foundation & plinth in hard soil.
Cement concrete for foundation & plinth in Rock.
Supply of galvanized fabricated steel work for gantry & supporting structure
Erection of galvanized fabricated steel work for gantry & supporting structure
Supply of galvanized fabricated steel work for small parts steel.
Erection of galvanized fabricated steel work for small parts steel.
Reinforced concrete for foundation, cable trench.
Provision of cable trench covers.
Erection of 150 Sq. Mm Copper Feeder Wire,
Extra on erection charges for power block work for Erection of 150 Sq. Mm Copper Feeder Wire,
Erection of 234 sqmm Aluminum (Spider conductor) feeder wire on separate mast
Supply of termination assembly for feeder wire including 25 KV solid core 9 Tone porcelain cut-in insulators & all accessories / fittings & fastners.
Erection of termination assembly for feeder wire including 25 KV solid core 9 Tone porcelain cut-in insulators & all accessories / fittings & fastners.
Supply of 25 KV solid core 9 Tone porcelain suspension insulator along with all accessories/fittings & fastners required for provision of solid core suspension insulator for feeder wire.
Erection of 25 KV solid core 9 Tone porcelain suspension insulator along with all accessories / fittings & fastners required for provision of solid core suspension insulator for feeder wire.
Supply of bimetallic parallel clamp & all accessories/fittings & fastners to provide bimettallic parallel clamp to avoid direct connection between aluminum feeder & copper jumper.
Erection of bimetallic parallel clamp & all accessories/fittings & fastners to provide bimettallic parallel clamp to avoid direct connection between aluminum feeder & copper jumper.
Supply of guy rod assembly.
Erection of guy rod assembly.
Erection of any type jumper assembly such as feeder Jumper, G Jumper, AT Jumper, Isolator Jumper etc.
Extra on erection charges for power block work for Erection of any type jumper assembly such as feeder Jumper, G Jumper, AT Jumper, Isolator Jumper etc.
Supply of 50x39 mm Al Tubular Busbar
Erection of 50x39 mm Al Tubular Busbar
Supply of various connectors in TSS/FP/SP/SSP(as per approved drawing)
Erection of various connectors in TSS/FP/SP/SSP(as per approved drawing)
Supply of conventional earthing station.
Erection, testing & commissioning of conventional earthing station.
Supply of armoured control cable of size 2 Core X 2.5 sq.mm
Laying, testing & commissioning of armoured control cable of size 2 Core X 2.5 sq.mm
Supply of Armoured control cable of size 7 Core X 2.5 sq.mm
Laying, testing & commissioning of armoured control cable of size 7 Core X 2.5 sq.mm
Supply of Armoured control cable of size 2 Core X 4 sq.mm
Laying, testing & commissioning of armoured control cable of size 2 Core X 4 sq.mm
"Supply of 10 Sq.mm Single Core Copper Cable Multi Stranded Flame Retardant PVC insulated cable of voltage grade 1100V."
Erection of 10 Sq.mm Single Core Copper Cable Multi Stranded Flame Retardant PVC insulated cable of voltage grade 1100V.
Supply of 25 KV vacuum Circuit breaker (Inclusive of terminal connectors suitable for 50 mm Alluminium tubular busbar).
Erection of 25 KV vacuum Circuit breaker (Inclusive of terminal connectors suitable for 50 mm Alluminium tubular busbar).
Supply of 25 KV, 1500-750/5A current transformer (protection) as per RDSO Specification No. ETI/PSI/90 (6/95) or latest
Erection, testing & commissioning of 25 KV, 1500-750/5A current transformer (protection) as per RDSO Specification No. ETI/PSI/90 (6/95) or latest
"Supply of 27.5 kV / 110 V Potential transformer. ((protection, Type-II) "
"Erection, testing and commissioning of 27.5 kV / 110 V Potential transformer. ((protection, Type-II) "
"Supply of 27.5 KV / 100 V Potential transformer. (Indication, Type-I) "
"Erection, testing and commissioning of 27.5 KV / 100 V Potential transformer. (Indication, Type-I) "
Supply of 42 KV Class lightening arrestor with surge monitor.
Erection, testing and commissioning of 42 KV Class lightening arrestor with surge monitor.
Supply of 25 KV AC 1600A, Single pole isolator with operating rod insulator.
Erection of 25 KV AC 1600A, Single pole isolator with operating rod insulator.
Supply of 40mm X 6mm MS flat for bonding including painting & hole drilling in rail.
Fabrication & fixing of 40mm X 6mm MS flat for bonding including painting & hole drilling in rail.
Supply of 50mm X 6mm MS flat for bonding.
Fabrication & fixing of 50mm X 6mm MS flat for bonding including painting & hole drilling in rail.
Supply of GI 8 SWG wire earthing
Erection of GI 8 SWG wire earthing
"Supply of Fencing Panel, (2.55 Mtr height) at SP,SSP.TSS,FP."
"Erection of Fencing Panel, (2.55 Mtr height) at SP,SSP.TSS,FP."
Supply of Fencing Uprights.
Erection of Fencing Uprights.
Supply of Gates for FP/SP/SSP/TSS
Erection of Gates for FP/SP/SSP/TSS
Supply of Anticlimbing device at switching station..
Erection of Anticlimbing device at switching station..
Supply of 20 mm ballast in the switch yard.
Spreading of 20 mm ballast in the switch yard.
Supply of Discharge Rod assembly including clamp/cable.
Supply & erection of caution Board / enameled Number plate/ Danger board.
Supply of Sectioning diagram.
Supply of single core 35 sq. mm multistrand copper cable. (LA & AT).
Erection of single core 35 sq. mm multistrand copper cable. (LA & AT). 2813000.0
Supply of Single Feeder Circuit Breaker Protection relay panel, including feeder protection relay, Delta I relay, DC fail relay, MTR and meter annunciators.(as per latest specification)
Erection, testing & commissioning of Single Feeder Circuit Breaker Protection relay panel, including feeder protection relay, Delta I relay, DC fail relay, MTR and meter annunciators.(as per latest specification)
Testing & commissioning of BMs/CBs in existing RTU alongwith necessary cables connection from terminal board/ C&R panel to RTU.
Modification in existing SCADA software at RCC/ BSL to accommodate the additional BM/CBs in SCADA
Integration of numeric relays with TSS/RTU and SCADA system at Remote Control Center.
Dismentalling of - Fencing Panel & transportation to Railway depot at BSL.
Dismentalling of - Fencing Uprights & transportation to Railway depot at BSL.
Dismentalling of - Gates & transportation to Railway depot at BSL.
Dismentalling of - Anticlimbing device including barbed wire & transportation to Railway depot at BSL.
Dismantling of 25 KV Bus bar system
Dismantling of Equipment foundation & making site clear.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS11.pdf
ATTACHMENT
Booklet40-2026.pdf
ATTACHMENT
Explanatory40-2026.pdf
ATTACHMENT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
Soleproprietorcertificatepdf_1.pdf Sole Proprietorship Certificate
ATTACHMENT
Soleproprietorcertificatepdf_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].