Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹13.5 L+₹88,650 (7.00%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹15.0 L+₹2.4 L (18.7%)Rejected-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹15.4 L+₹2.8 L (22.1%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹19.8 L+₹7.1 L (56.3%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹20.0 L
EMD Value
₹39,940
Closing Date
22 Dec 2021, 6:00 pmClosed
GE EM RR HOSPITAL
GE EM RR HOSPITAL RAO TULA RAM MARG DELHI CANTT-10
CA No GE/H-36/2021-22 REPAIR/MAINT OF STREET LIGHT AND OTHER CONNECTED WORKS AT AHRR UNDER GE E/M RR HOSP AT DELHI CANTT-10
2021_MES_490134_1
GE/H-36/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE EM RR HOSPITAL
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹39,940
Yes
16 Feb 2022
24 Nov 2021
24 Dec 2021
24 Nov 2021
22 Dec 2021
8 Dec 2021
Amount
Repairing/Checking of existing street light / flood light/ post top lantern/ bollard light of any type or description, fixed in vertical position with poles / wall /on high mast including disconnecting the electric connection, taking down from pole / high mast / wall if required, carrying out necessary repairs like disconnection of wire/cable, carbon removing, cleaning of acrylic/glass sheet cover with detergent powder and replacing of starter, fuses, drivers, LED panel, choke, bulb etc as required at site to make the lights fully functional and refixng the same with clamps,screw, washer and other fixing accessories at same location or any other location, connecting with electric feeder and testing for functioning by engaging sufficient man power and tool & plant etc to ensure safety of light / pole as well as working persons complete all as specified and directed by Engr-in-Charge. Note for item No. 1 : (a) The cost of all kind of repair /servicing/ replacement of defective items/devices and other minor parts/spares or insulation tape, ferruls,lugs,connector,fixing accessories as and when required for making the all street lights fully functional, is deemed to be included in quoted rates. However, the major parts / items shall be measured & paid separately under relevant item of this Schedule. (b) The cost of Tool & plant, ladder any type for street light repairing deemed to be included in quoted rates. (c) Complaint slip in duplicate and necessary stationery shall also be arranged by the contractor without any extra cost for recording / monitoring of street light complaints. (d) Contractor shall deploy a supervisor with serviceable mobile no. to receive the complaints, maintain the complaint slip and monitor the street light repairing team. (e) All the Complaint / fault(s) once lodged to the rep of contractor verbaly, telephonically or with complaint slip shall be rectified within 24 hrs and after rectification the complaint slip should be handed over to concern JE E/M. If contractor or his tradesmen fails to rectify the complaint within 24 hrs from the time of receipt, the compensation/penalty of Rs. 500.00 (Rupees Five Hundred only) per complaint per day (i.e 24 hrs ) shall be recovered from the contractor’s dues. (f) In case contractor / his rep does not attend the office to receive complaint from JE E/M or his rep, penalt of Rs. 1000.00 (Rupees One Thousand only) per day (i.e 24 hrs ) shall be recovered from the contractor’s dues.
Supply only in replacement HPSV lamp 400 watt, single ended screw type, tubular type as existing shape and size comcomplete all as specified and directed by Engr-in-Charge.
All as per srl item No 2 above but 250 watt.
All as per srl item No 2 above but 150 watt.
All as per srl item No 2 above but 70 watt.
Supply only in replacement Open Construction copper ballast (Choke) suitable for 400 watt MH / HPSV light fitting complete all as specified and directed by Engr-in-Charge.
All as per srl item No 6 above but 250 watt.complete all as specified and directed by Engr-in-Charge.
All as per srl item No 6 above but 150 watt.
All as per srl item No 6 above but 70 watt.
Supply only in replacement ignitor suitable for HPSV/MH fitting of 70 - 400 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement capacitor 42 MFD for HPSV/MH fitting of 400 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement capacitor 33 MFD for HPSV/MH fitting of 250 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement capacitor 20 MFD for HPSV/MH fitting of 150 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement capacitor 10 MFD for HPSV/MH fitting of 70 watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement lamp holder suitable for single ended tubular/elliptical HPSV/MH lamps of 250/400 Watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement lamp holder suitable for single ended tubular/elliptical HPSV/MH lamps of 150/70 Watt complete all as specified and directed by Engr-in-Charge.
Supply only in replacement of driver for LED street light/Flood light of 40 watts to 60 watts, 240 Volts, single ph, 50Hz or as per existing make & model to made LED light serviceable complete all as specified and directed by Engr-in-Charge.
All as per ser item No. 17 here-in-before but of 90 watts to100 watts 240 Volts, single ph, 50Hz.
All as per ser item No. 17 here-in-before but of 120 watts 240 Volts, single ph, 50Hz .
Supply only in replacement LED panels for LED street light/Flood light of 40 watts to 60 watts 240 Volts, single ph, 50Hz capacity or as per existing sample to made LED light serviceable complete all as specified and directed by Engr-in-Charge.
All as per ser item No. 20 here-in-before but of 90 watts to 100 watts 240 Volts, single ph, 50Hz .
All as per ser item No. 20 here-in-before but of 120 watts 240 Volts, single ph, 50Hz.
Taking down existing street light of any type and Supply & fixing in replacement LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
All as per srl item No 23 but of 60 Watts.
All as per srl item No 23 but of 90 Watts.
All as per srl item No 23 but of 120 Watts.
Taking down existing flood light of any type and Supply & fixing in replacement LED flood light 50 watt 230 V, AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.
All as per srl item No 27 but of 100 Watts flood light.
All as per srl item No 27 but of 120 Watts flood light .
Supply & fixing in replacement LED Post top 25 watts, new generation, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED's as light source confirming to IP65, 230 volts, 50 Hz complete all as specified and directed by Engr-in-Charge.
All as per srl item No 30 but for 35 Watts.
Supply & fixing in replacement of LED 9 watts bollards for pathways & gardens are made with aluminium extrusion strudiness and better finish. UV stabilized injection moulded opal polycarbonate diffuser for spot- free lighting and IP-65 degree of protection operating on, 240 volts, 50 Hz complete all as specified and directed by Engr-in-Charge. Note for item Ser No 23 to 32 (i) Quoted rate is deemed to include rate of cable connections. (ii) Contractor shall be responsible for proper fixing of fitting with existing location ie. Poles/ walls. (iii) Contractor shall submit warranty of minimum 2 yrs from date of installation on company letter head. (iv) If new Led light is found to be unserviceable in warranty period then the same shall be repaired/ replaced with the serviceable LED light of same wattage without any extra cost and this also include taking down and refixing of LED light.
Supply & fixing in replacement LED bulb 5 watts complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 25 mm dia size light grade complete with nut, bolts, clamp washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint, complete all as specified and directed by Engr-in-Charge.
Ditto as per item ser No 34 here-in- before but 40 mm dia .
Supply & fixing in replacement street light digital timer switch DIN type Daily /weekly with 2CO 16 Amps complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacment street light panel 3 phase frame of capacity 40 A 3 Pole incl Digital timer, power contact, isolator 4 pole, indicator lamps with switch for bypass arrangment and fixing by making proper foundation with angle iron frame or fixed in pole complete all as specified and directed by Engr-in-Charge.
Material & labour in replacement of 1100 volt grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tap and over all PVC sheathed in service connection for street light from FRP junction box to street light of size 3 core 1.5 sqmm complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement SMC/FRP junction box for street lighting for 3 phase/4 core, outdoor type, inside dimensions (HxWxD) 240mm X 130mm X 110mm, consisting bus bar rating 63 amps 4 strips aluminium with bus bar mounting colour R, Y, B, N on DMC unbreakable insulator with cable entry from bottom and/or sides, MCB SP 6-32 amps - 01 No, shock proof, rust proof, temper proof, 100% weather proof, restricts unauthorised tapping, maintenance free, fire retardant, having front opening and locking arrangement, box duly fixed on the pole with flat iron clamp of size 25 mmX3mm with nuts & bolts complete all as specified and directed by Engr-in-Charge. (Note : Cost of incoming & outgoing cable lugs & glands of suitable size deemed to be included in the quoted rate)
Supply & fixing in replacement HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 295mm x 255mmx 120mm incl 4 way heavy duty terminal block with and two number of PVC cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of micro prismatic reflective sheet, min 2.5 cm wide, with adhesive base for directly fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replcement power contactor for street light panel 40 Amps rating capacity with 415 AC volt complete with testing complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of MCB SP 6 to 32 Amps 240 Volts ('C' curve) complete all as specified and directed by Engr-in-Charge.
Excavation in trenches in soft / loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out complete all as specified and directed by Engr-in-Charge.
M&L Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand complete all as specified and directed by Engr-in-Charge.
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all as specified and directed by Engr-in-Charge.
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Taking out old defective under ground cable from trenches floor / road / wall / pipe/ pole of size and description, complete all as specified and directed by Engr-in-Charge.
Labour for re-laying the serviceable part of cables of any size staking out under above mention items after repairing defects / making joints etc in same trench or any other location, complete all as specified and directed by Engr-in-Charge. Note : The excacation, earth work, sand cushioning, protection cover, and cable joints etc will be measured and paid for seperately under respective items.
M&L for laying of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, in trench/ in pole/ in duct of 4.0 core x 10 sqmm cross-sectional area complete all as specified and directed by Engr-in-Charge.
All as per srl item No 51 above but of 4.0 core x 16 sqmm.
All as per srl item No 51 above but of 4.0 core x 25 sqmm.
All as per srl item No 51 above but of 3.5 core x 35 sqmm.
All as per srl item No 51 above but of 3.5 core x 50 sqmm.
M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boudders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as specified and directed by Engr-in-Charge.
S&F of GI pipe of 80 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed by Engr-in-Charge. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
All as per srl item No 57 here-in-before but for GI pipe of 50 mm dia size.
Material and labour for cement concrete type B1, 1:2:4 with 20mm graded aggregate for coping of poles, including necessary form work complete all as specified and directed by Engr-in-Charge.
M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
M&L for cleaning, scrubbing and preparation of old, rusted painted surface of existing steel tubular pole of 09 to 11 mtr height complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making black & yellow alternative strips of 30 cm height with synthetic enamelled paint and upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint complete all as specified and directed by Engr-in-Charge.
Supply & fixing of surge protection device single phase equipment protection for LED street light complete all as specified and directed by Engr-in-Charge. Note- (a) SPD shall be suitable for 240 V AC single phase systems. (b) Maximum continues operating voltage of the SPD shall be not less than 290V (c) SPD shall be compact and with flying leads of mimimum 2.5 sq mm (d) SPD shall be green LED status indicator to show the healthiness. (e) SPD must be rated for maximum surge current of 15 KA. (f) Warranty: 02 Years with replacement without any extra cost to dept.
Supply & fixing of three phase lightining & Surge Protection device Class II protection for OT /ICU main DB in switch room and street light control panel 100 KA complete connection through 6.0 sqmm copper insulated multistranded wire complete all as specified and directed by Engr-in-Charge. Note. (a) SPD shall be suitable for a working Voltage 240/415V, 3 phase 4 wire system and surface mount. (b) Maximum continues operating voltage of the SPD shall be not less than 290V. (c) SPD shall be Green, Red LED status indicator, Remote singnaling and audible alarm which triggers during fault. (d) SPD must be rated for maximum surge current of 100 KA. (e) Warranty: 02 Years with Replacement without any extra cost to dept.
Labour and necessary T&P for shifting of street light pole of any type/length from existing position to new location whereas directed including transportation, T&P & errection on site complete all as specified and directed by Engr-in-Charge. Note: Excn, returning, refilling and PCC items will be measured and paid separately.
M&L for trimming / cutting of tree branches of girth upto 150 mm dia or 3 m all around of any size obstucting lumination of street light/ flood light/ building security light and touching any E/M installation including removal of trimmed tree branches complete all as specified and directed by Engr-in-Charge. Note: Each cut shall be measured and paid..
sheetal engineering
OMVIN ENTERPRISES LLP
CHAUHAN ENTERPRISES
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .