Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC AOC | |
| 2 | L2₹29.2 L+₹81,770 (2.88%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-AOC Rejected other than L1 | |
| 3 | L3₹29.3 L+₹92,660 (3.26%)Rejected-AOC 137 D6 ARAVALI HEIGHTS DPL DWARIKADISH ROAD DHARUHERA REWARI HARYANA 123106 | REWARI | HARYANA | 123106 | L3 | Rejected-AOC Rejected other than L1 | |
| 4 | L4₹31.7 L+₹3.3 L (11.8%)Rejected-AOC | L4 | Rejected-AOC Rejected other than L1 | |
| 5 | L5₹32.1 L+₹3.7 L (13.0%)Rejected-AOC D 35 NEAR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L5 | Rejected-AOC Rejected other than L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
23 Jan 2025, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon
CA NO. GE AF NO.1/GUR-68/2024-25 PROVN OF GEYSERS FOR AIRMEN BILLET AND SPECIAL REPAIR TO CERTAIN E/M WORKS AND MINOR WORK AT AF STATION PALAM UNDER GE (AF) GURGAON NO. 1.
2024_MES_689809_1
GE (AF) Gurgaon No 1/GUR-68/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
Yes
₹82,000
Yes
17 Feb 2025
26 Dec 2024
25 Jan 2025
26 Dec 2024
23 Jan 2025
9 Jan 2025
Amount
Schedule-A
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc as per existing and all as specified as directed.
Taking down carefully by unscrewing from the boards/outlets boxes fittings and fixtures such as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbed surfaces as per existing and all as specified as directed.
Taking down of existing old unserviceable submain wiring from conduit , wall, ceiling of any height complete all as specified and as directed and making good disturbed surfaces of walls, floors etc as per existing and all as specified as directed.
Taking down of existing old unserviceable distribution box including MCB/MCCB complete all as specified and as directed and making good disturbed surfaces of walls, floors etc as per existing and all as specified as directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (medium grade), exposed to surface wherever required including conduit as specified and making good to surface by using CM 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also complete including PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one, one way switch complete all as specified and as directed by Engineer-in-charge. Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.
For one light point controlled by one single pole switch.
For one fan/exhaust/wall mounted point controlled by one single pole switch.
For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm
For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size
All as per item No 2 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant low smoke ( FRLSH ) cable for 1 5 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc including taking down of old u/s wiring required complete all as specified and directed.
S&F Modular switch, one way 6 Amps , 1 module complete all as specified and directed.
S&F Modular socket, 2/3 pin 6 Amps , 2 module complete all as specified and directed.
S&F Modular switch, one way 16 Amps , 1 module complete all as specified and directed.
S&F Modular socket, 2/3 pin 6/16 Amps , 2 module complete all as specified and directed.
Supply & Fixing of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge.
S&F steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Supply & fix Modular White cover plate with frame for 1/2 module alongwith metal flush box complete all as specified and directed.
Supply & fix Modular White cover plate with frame for 3 module alongwith metal flush box complete all as specified and directed.
Supply & fix Modular White cover plate with frame for 6/ 8 module alongwith metal flush box complete all as specified and directed.
S&F submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes and making good to surfaces in wall/floor for passing in or through conduit.
S&F submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes and making good to surfaces in wall/floor for passing in or through conduit.
S&F in replacement to old conventional tubelights, 40/42 Watt (+/- 5%) LED recess mounting fitting(2' x 2') CRCA powder coated having polycarbonate diffuser powedered by independent electronic LED driver haing IP 20 protection,CCT 6000 K,230/240 VAC,lumen efficacy > 140 lm/w including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.
S&F in replacement 40/42 Watt (+/- 5%) LED surface mounted fitting(2' x 2') CRCA powder coated having polycarbonate diffuser powedered by independent electronic LED driver haing IP 20 protection,CCT 6000 K,230/240 VAC,lumen efficacy > 140 lm/w including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SP&N 4 way fabricated from minimum 1.6 mm thick CRCA sheet with single door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 4 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. Make: Legrand /Siemens/Schneider.
Supply and fixing of factory made epoxy polyster powder coated distribution board SP&N 4 way fabricated from minimum 1.6 mm thick CRCA sheet with single door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 4 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. Make: Legrand /Siemens/Schneider.
Supply and fixing in replacement of factory made epoxy polyster powder coated distribution board SP&N 6 way fabricated from minimum 1.6 mm thick CRCA sheet with single door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incoming and 8 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, 'C' series type complete all as specified and as directed.
S&F MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
S&F MCB SP 40 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .
Supply and fixing factory made epoxy polyster powder coated VTPN distribution board Triple pole MCB 12 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, provision for 125 Amps MCCB as one incommer and 12 outgoings triple pole MCB with 2 Neutral bar, 2 Earthbar, Fully insulated busbar rated capacity above 160Amp, shrouded Neutral bars and cable ties for cable management complete all as specified and confirming to IEC 61439-3,Reversible door IP 43 & IP 54. Make: Legrand /Siemens/Schneider. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
Supply & Fixing MCCB 125 Amps 4 Pole, 415 V, fixed thermal & fixed magnetic setting electromechanical type with Ics=75 % of Icu , with breaking capacity 16 KA conforming to IS: 13947-II complete all as specified and as directed.
Supply & Fixing MCB B curve 40 Amps 3 Pole, 415 V, fixed thermal & fixed magnetic setting electromechanical type with Ics=75 % of Icu , with breaking capacity 10 KA conforming to IS: 13947-II complete all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth including plug and socket complete set with one single pole MCB of 20 Amps,complete all as specified and directed.
Supply and installation hi wall split units indoor/outdoor 2 TR capacity complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2. complete with copper tubing upto 10 m length, nitrile insulated complete all as per requirement of length and angle iron bracket fabricated out of 40x40x5mm angle iron for installation of outdoor unit , including making hole in existing wall for copper suction and discharge pipe complete all as specified and directed .
S&F nylon braided PVC pipe of size 20mm dia outer suitabel for split AC drain including fixing accessories such as claps scews rawl plugs etc complete all as specified and directed
S&F pre-fabricated AC stand suitable for wall mounting or floor mounting made with mild painted with synthetic enamel paint with anti vibration rubber pads including grouting in wall applicable for wall mounting type complete all as specified
M&L for suctionand discharge copper tubing of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 2 TR capacity including soldering and braizing complete all as specified and directed. Note:- Suction and discharge copper tubing together wil be measured as one unit of running metre.
All as per item No 34 above but copper tubing size 5/8 inch and 3/8 inch dia and 0.5mm thickness
M&L for insulating the suction and discharge copper tubing from in door unit to outdoor unit of split type Acs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves incuding sealing by applying adhesive tape fo brown or white colour to avoid minimum contact with atmosphere complete all as specified and directed
S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stabilized at 230 V with accuracy of ±9.0% and of capacity 0.5KvA to 5.0 KvA with time delay relay (TDR) of 2 to 3 minutes, , LCD display of 5 KVA rated capacit over load/ short circuit protections,high/low voltage cutt off,by pass arrangement in case of emergency, single phase sequence change protection complete all as specified and directed.
Supply , fixing and testing electric water heater storage type steel body with copper inner tank and heating element upto 2kW capacity 50 litre BEE 5 star rated with all accessaries such as safety thermostat, NRV, connection piece for inlet and outlet water supply line including fixing on wall with fastner or making necessary arrangement for fixing of fabricated angle with suitable lenth as per site requirement in existing wall of any type and condition for mouting the geyser and making necessary electrical and water pipe connection complete all as specified and directed and make good the disturbed surface to the existing wall complete as directed by Engr-in-Charge.
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth and 5 cm width complete all as specified and directed.
Supply, laying, jointing and testing galvanized iron water tubing medium grade of size 15 mm bore in walls and ceilings or laid in floors , including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
Supply, laying, jointing and testing galvanized iron water tubing medium grade of size 20 mm bore in walls and ceilings or laid in floors , including provision of all necessary ISI marked GI fittings / accessories complete all as specified and directed.
S&F 15 mm bore fancy type CP Bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brassferrule and fixed complete all as specified and as directed.
S&F 15 mm bore fancy type CP stop valve cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brassferrule and fixed complete all as specified and as directed.
M&L for metal flush box for fixing of switches for 3 module complete all as specified and directed.
M&L for concealed sub main wiring three run of 1.5sqmm PVC insulated unsheathed copper conductor cable ISI marked 1100 volts grade drawn in and including PVC surface conduit suitable size of medium grade fixed on wall / ceiling / passing through wall etc concerned as required at site complete all as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes and making good to surfaces in wall/floor for passing in or through conduit.
S&F of recessed mounted commercial luminaire LED type of size 1X4 Feet with CRCA having suitable for offices , hospitals and educational instutute of capacity 36 Watt , 220 Volt, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as specified and directed.
Note :- The amount of Rs 39416/- against Schedule of Credit on Srl Page 162 shall be deducted from the total amount quoted against Sch 'A'
M/S Anand Enterprises (BID ID -3215999)
Shrikanth Solutions (BID ID -3212221)
S.R. Constructions (BID ID -3220644)
m/s rudraksh enterprises (BID ID -3215110)
HSEDRIG ENGINEERS AND CONTRACTORS (BID ID -3215868)
DR Buildcon (BID ID -3216411)
JAIPAL AND BROTHERS (BID ID -3222180)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .