| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-Finance SFNO 73 UTHUKULI ROAD MANNARAI TIRUPUR | TIRUPPUR | TAMIL NADU | 638051 | ₹6.5 L | L1 | Accepted-Finance L1 Have a Low Value Quoted hence Accepted |
| 2 | L2₹6.5 L+₹2,916.28 (0.45%)Rejected-Finance | ₹6.5 L+₹2,916.28 (0.45%) | L2 | Rejected-Finance L2 Have a High Value Quoted hence Rejected |
| Sl No | Description | Qty | Unit | Kalidoss L1 | R MUTHUVEL L2 |
|---|---|---|---|---|---|
| 1.00Construction of Bus shelter in Thenampadugai Main Road at Thenampadugai Panchayat | |||||
| 2.00 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. | 19.48 | Cum | 263 ₹5,123.24 Lowest | 265 ₹5,162.2 |
| 3.00 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 5.88 | Cum | 2,355 ₹13,847.4 Lowest | 2,360 ₹13,876.8 |
| 4.00 | Cement Concrete 1:4:8 (One Cement, Four M.Sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification | 4.28 | Cum | 6,180 ₹26,450.4 Lowest | 6,185 ₹26,471.8 |
| 5.00Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 8 3/4” x 4 1/4” x 2 1/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. | |||||
| 6.00 | For foundation & basement | 2.52 | Cum | 6,210 ₹15,649.2 Lowest | 6,215 ₹15,661.8 |
| 7.00 | Superstructure in Ground floor | 8.37 | Cum | 6,300 ₹52,731 Lowest | 6,310 ₹52,814.7 |
| 8.00Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) | |||||
| 9.00 | For Column footing plinth beam staircase steps, piers raft beam raft Slab etc | 11.46 | Sqm | 547 ₹6,268.62 Lowest | 548 ₹6,280.08 |
| 10.00 | For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. | 5.47 | Sqm | 1,200 ₹6,564 Lowest | 1,205 ₹6,591.35 |
Tender Value
₹6.6 L
EMD Value
₹6,600
Closing Date
24 Jun 2026, 3:00 pmClosed
Block Development Officer (BP) Kumbakonam
Panchayat Union Office, Kumbakonam
Thanjavur District Kumbakonam Block - Construction of Bus shelter in Thenampadugai Main Road at Thenampadugai Panchayat. Under MLACDS 2025-2026.
2026_RDTN_680193_1
Rc.No.1200/2025/A2 dated 10.06.2026
Open Tender
Civil Works
Item Rate
360 days
Panchayat Union Office, Kumbakonam
As per Tender document
9 documents required · 9 mandatory
₹0
₹6,600
19 Sept 2026
10 Jun 2026
24 Jun 2026
10 Jun 2026
24 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Bus shelter in Thenampadugai Main Road at Thenampadugai Panchayat | - | - | - | - |
| 2 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. | 19.48 | Cum | - | - |
| 3 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 5.88 | Cum | - | - |
| 4 | Cement Concrete 1:4:8 (One Cement, Four M.Sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification | 4.28 | Cum | - | - |
| 5 | Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 8 3/4” x 4 1/4” x 2 1/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. | - | - | - | - |
| 6 | For foundation & basement | 2.52 | Cum | - | - |
| 7 | Superstructure in Ground floor | 8.37 | Cum | - | - |
| 8 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) | - | - | - | - |
| 9 | For Column footing plinth beam staircase steps, piers raft beam raft Slab etc | 11.46 | Sqm | - | - |
| 10 | For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. | 5.47 | Sqm | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
TecnicalBitz.pdf
Tender Documents • 0.57 MB
Prizebits.pdf
Tender Documents • 0.54 MB
BOQ_817365.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .