Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.9 LAccepted-AOC C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹25.9 L+₹2.0 L (8.53%)Rejected-Finance 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-2 | Rejected-Finance NOT BEING A LOWEST BIDDER | |
| 3 | L-3₹27.3 L+₹3.4 L (14.2%)Rejected-Finance | L-3 | Rejected-Finance NOT BEING A LOWEST BIDDER |
Tender Value
₹34.4 L
EMD Value
₹68,800
Closing Date
1 Aug 2022, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
PROVN OF ELECTRIC SUPPLY FOR ALL DSC POSTS 06 X WALL FAN LIGHTS WITH SOCKETS AT KHUNMOH 26 X EXHAUST FANS AT SHER E SHALI AND 02 X GEYSER AT KHREUH UNDER GE 861 EWS
2022_MES_535446_1
GE 861 EWS-29/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 861 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹68,800
Yes
21 Sept 2022
2 Jul 2022
8 Aug 2022
2 Jul 2022
1 Aug 2022
18 Jul 2022
Amount
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable maintaining colour coding (Phase- Red/yellow/Blue, Neutral- Black) and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-1 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per serial item No 2 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Point wiring for 3 pin 15 Amps socket outlet independent/combined board controlled by one switch with 4.0 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable maintaining colour coding (Phase- Red/yellow/Blue, Neutral- Black) and 4.0 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
Steel water tubing, 15 mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths and making connection for geysers inlet water in the existing GI pipe/tanks and making good disturbed surfaces in CM 1:3, complete all as specified and directed.
15mm bore stop valves, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, complete all as specified and directed.
15mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts, complete all as specified and directed
MCB, SP, AC, 240 volts "B" series capacity of 32 to 40 Amps, 10kA and making connections complete all as specified & directed.
Exhaust fan, steel body (metal ventilation, double ball) AC single phase, 1200 RPM, copper winding, 230V of size 250mm sweep with blades, frame and louvers including necessary work in wall/sheet, including necessary fixing arrangement on window/ventilation window as per site requirement and connection cable of suitable size, nuts, bolts and other fixing material, complete all as specified and directed.
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece (PVC connection 15mm size with PTMT nuts of length 450mm suitable for hot & cold water for geysers) etc. including connection with three core copper wire and fixing arrangement like claps, nuts, bolts, washers, suitable type of fastners and making good disturbed surfaces as per existing, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exc 1.50m but n.exc. 1.50m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Reinforced precast concrete cable cover, class LV, Type I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified.
Steel tubular swaged poles, swan neck type, complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long), complete all as specified and directed.
70 watt LED street light fitting 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specified and directed.
MCCB 4 pole, 415 volts adjustable type, 40 Amps with breaking capacity 16 KA complete all as specified and directed.
MCCB 4 pole, 415 volts adjustable type, 350 Amps with breaking capacity 36 KA complete all as specified and directed.
1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 sqmm nominal cross section 2.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Description all as per item No. 23 above but cross sectional area 16 Sqmm 4.0 core complete all as specified and directed.
Description all as per item No. 23 above but cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 23 above but cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 23 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure & making good the same to match the existing surface, complete all as specified and directed.
GI tubing light grade 40mm dia with all fitting laid in trenches or fixed on wall along pole complete for protection of electric cable/strip, complete all as specified and directed.
MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 IK-09 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, complete all as specified and directed.
MCB distribution board TPN, vertical type 4 way, 240V wirh 200 Amps rated copper busbar with neutral links double door sheet steel enclosure powder coated, IP-43 IK-09 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, complete all as specified and directed.
MCB, SPN, AC, 240 volts "C" series capacity of 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SP, AC, 240 volts "C" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
Junction box of size 300x300x250 mm made of MS Sheet 1.6mm thick, front door openable with fixing screw painting with two coats of synthetic enamel powder coated paint over a coat of red oxide including alumn bus bar 4 Nos of size 25x3mm mounted on epoxy based post insulators and drilled holes for connection including 1 No MCBs 06 amps incl magnetic lock system all as required and fixed to poles using MS strip of size 32x6mm and nuts & bolts of required size all as required at site or as directed.
Security light brackets with 1.50mtrs long 40mm dia medium grade galvanised iron pipe with 30° bend including flat iron clamps, nuts, bolts and washers to brace the same properly duly painted with two coats of silver coloured synthetic enamel paint over one coat of red oxide primer and making the good to disturbed surfaces to match with existing, complete all as specified and directed.
Supply & install and testing voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ±1% and speed of correction 50 Volts per second and of capacity 25 KVA, complete all as specified and directed.
Supply & install and testing voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ±1% and speed of correction 50 Volts per second and of capacity 100 KVA, complete all as specified and directed.
Supply, fabrication, installation, testing & commissioning of Wall mounted LT Panel board / Feeder piller box, outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet,side canopy, front & back openable doors having aluminium bus bar of capacity 480 amps for phases and 240 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete all as directed and suitable to accommodate the following switch gears and meters:- (a) MCCB 630 Amps 4 pole, 50 KA, Thermal magnetic - 1 No (Incomer) (b) MCCB 200 Amps 4 pole, 35 KA, Thermal magnetic - 02 Nos (Out going) (c) MCCB 160 Amps 4 Pole, 25 KA, Thermal magnetic - 02 Nos (Out going) (d) MCCB 100 Amps 4 Pole, 25 KA,Thermal magnetic - 02 Nos (SPR) (e) Volt meter , digital type ,0 - 500V - 1 Nos. (f) Ammeter, digital type with CT's - 1 No (h) Indication lamps (R,Y,B) LED type - 1 set
Supply, fabrication, installation, testing & commissioning of Wall mounted LT Panel board / Feeder piller box, outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, 3 phase 4 wire 50 Hz AC , side canopy, front & back openable doors having aluminium bus bar of capacity 150 amps including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete all as directed and suitable to accommodate the following switch gears and meters:- (a) MCCB 4 Pole, 100 Amps, 25 KA, thermal magnetic - 01 Nos (Incoming) (b) MCCB 4 Pole, 50 Amps, 16 KA, thermal magnetic - 01 Nos (Out going) (c) MCB, SPN 32 Amps,10 KA - 02 Nos (Out going). (d) MCB TPN 32 Amp, 10 KA -01 No (outgong) (e) Ammeter, digital type with CT's - 1 No (f) Indication lamps (R,Y,B) LED type - 1 set
Supply, fabrication, installation, testing & commissioning of Wall mounted LT Panel board / Feeder piller box, outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, 3 phase 4 wire 50 Hz AC , side canopy, front & back openable doors having aluminium bus bar of capacity 60 amps including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete all as directed and suitable to accommodate the following switch gears and meters:- (a) MCCB 4 Pole, 40 Amps, 25 KA, thermal magnetic - 01 Nos (Incoming) (b) MCCB 4 Pole, 32 Amps, 16 KA, thermal magnetic - 01 Nos (Out going) (c) MCB, SPN 32 Amps,10 KA - 02 Nos (Out going). (d) Ammeter, digital type with CT's - 1 No (e) Indication lamps (R,Y,B) LED type - 1 set
Earthing complete with galvanised cast iron earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6mm as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 11.00%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 11.00%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
450mm sweep 1400 RPM air circulators fans 230 volts single phase, oscilating suitable for wall mounting, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 1.50 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 1.50 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked, complete all as required at site or directed.
Switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal, complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
LED lights fitting 1x20W, 230V, AC 4 feet, surface mounted box type indoor decorative T-5 LED engineering plastic batten integrated type with white acrylic cover sleek design with high efficiency complete with all accessories, internally pre-wired including fixing on wall/ceiling with PVC round/square block-02 Nos and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. Make Bajaj Cat Part No BCLSB 20 WH or equivalent in Crompton Greaves/ GE/Philips/Havells.
50 watt flood light luminairewith secondary optics, aluminium pressure die-cast housings with IP66 ingress protection, 4kV inbuilt surge protection including necessary connection suitable size copper conductor cable, complete all as specified and as directed. Make Bajaj Cat Part No BJFL 50W LED I or equivalent in Crompton Greaves/ GE/Philips/Havells.
MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 IK-09 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, complete all as specified and directed.
MCB, SPN, AC, 240 volts "C" series capacity of 40 Amps, 10 kA and making connections, complete all as specified & directed.
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion, complete all as specified and directed. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 11.00%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
M/S TAHIRA ENTERPRISES
M/S AK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .