| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC | ₹4.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹4.3 CrRejected-Finance ADD HANUMAN MANDIR ROAD KRISHNAPURI CHUTIA DORANDA CHUTIYA RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | ₹4.3 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹4.4 CrRejected-Finance | ₹4.4 Cr | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical NON RESPONSIVE |
| Sl No | Description | Qty | Unit | M/S S.S. ENTERPRISES L2 | M/S SETH KUMAR L3 | M/s N. K. Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 0.26 | HA | 74,596.23 ₹19,395.02 | 76,428.17 ₹19,871.32 | 70,799.6 ₹18,407.90 |
| 2.00 | Dewatering the water from Ground Floor Courtyard area by pumpting the water to nearby drain Dewatering pump 10 HP | 16 | Hour | 157.93 ₹2,526.88 | 161.8 ₹2,588.80 | 149.89 ₹2,398.24 |
| 3.00 | Unskilled Labour | 16 | Hour | 275.5 ₹4,408 | 282.27 ₹4,516.32 | 261.48 ₹4,183.68 |
| 4.00 | Diesel | 80 | Litre | 78.67 ₹6,293.60 | 80.6 ₹6,448 | 74.66 ₹5,972.80 |
| 5.00 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. | 23.71 | SQM | 155.14 ₹3,678.76 | 158.95 ₹3,769.10 | 147.25 ₹3,491.67 |
| 6.00 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. | 1,391.77 | sqm | 461.73 ₹6.4 L | 473.07 ₹6.6 L | 438.23 ₹6.1 L |
| 7.00 | Wire Mesh (For Deep Cracks) | 400 | KG | 43.54 ₹17,416 | 44.61 ₹17,844 | 41.33 ₹16,532 |
| 8.00 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. | 130.72 | SQM | 180.78 ₹23,632.47 | 185.22 ₹24,212.88 | 171.58 ₹22,429.80 |
| 9.00 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | 17,620.99 | SQM | 17.31 ₹3.1 L | 17.73 ₹3.1 L | 16.43 ₹2.9 L |
| 10.00 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over old surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. | 17,620.99 | SQM | 184.74 ₹32.6 L | 189.28 ₹33.4 L | 175.34 ₹30.9 L |
Tender Value
Refer Docs
EMD Value
₹5.1 L
Closing Date
2 May 2025, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Ranchi.
Renovation/strengthening of the Doctor s Hostel located in the 500 bedded Sadar Hospital Complex in Ranchi District
2025_JSBCC_99772_1
JSBCCL/127/2024-25
Open Tender
Civil Works - Buildings
330 days
Ranchi
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹5.1 L
9 Apr 2026
11 Apr 2025
5 May 2025
11 Apr 2025
2 May 2025
11 Apr 2025
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Dewatering the water from Ground Floor Courtyard area by pumpting the water to nearby drain Dewatering pump 10 HP
Unskilled Labour
Diesel
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
Wire Mesh (For Deep Cracks)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over old surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
Providing and fixing double scaffolding system (cup lock type) onthe exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective ofduration of scaffolding.
Finishing walls with textured exterior paint of required shade : 13.110.1 Old work (Two or more coats applied @ 3.28 ltr/10 sqm)
Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I.
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Cleaning tile flooring with acid and wiping the surface clean as per the direction of Engineer In-charge
Mirror polishing on marble work/Granite required to give high gloss finish complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Taking down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
Supplying, fitting and fixing 30mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 30mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge
Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading 30 mm thick pre laminated PVC door shutters
Providing and fixing factory made uPVC white colou casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Providing designation 75 A brick work in C.M. (1: 4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in?charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge With average thickness of 120 mm and minimum thickness at khurra as 65 mm. including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for cXUing and foU final WeVW.³All aboYe opeUaWionV Wo be done in oUdeU and aV diUecWed and Vpecified b\ Whe Engineer-in-Charge :
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage
Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- 272 KL UGR (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete - 20mm diameter
Providing and fixing 25 mm thick shutters for cup board etc. : Panelled or panelled & glazed shutters : Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws
supplying fitting and fixing aluminium fittings of approved quality and make to doors and eindows all complete as per building specification and direction of E/I. 300mm sliding door bolt
250mm Tower bolt
100mm door handle with plate
Anodised aluminium hanging type door stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Supplying, fitting & fixing polycarbonate sheet of approved make & brand conforming to IS: 14443-1997 and having 50micron UV protection layer under co-extrusion technology, Fire rating being B-s1 as per EN13501-1 certification, fitted and fixed with 60mm wide aluminium channel section topand bottom member in dry-glaze sandwitch system, (unit wt.of top and bottom members: 0.375 kg/m & 0.69 kg/m) ofapproved brand and profile, EPDM quality rubber gaskets, anti dust tape, end closer "C" channel and 75 mm long Selftapping screw being drilled through the centre leg of thebottom section with nuts placed at 300 mm apart withoutanyway puncturing the polycarbonate sheet, EPDM Washer 16 mm dia & 3 mm thick washer etc complete strictly as permanufacturers specification and direction of Engineer-inCharge. (Payment to be made on area of finished work) . In Roof:- Natural/ Blue/Green/Bronze/Opal/Metallic grey colour
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).WT. of stainless steel 8 kg/sqm
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.(75MM THK)
Providing and laying in position cement concrete of specified grade excluding the cost of centering shuttering - All works upto plinth level.1:3:6 (1 cement: 3 coarse sand(zone III):6 graded stone concrete 20mm nominal size)
centring and shuttering including strutting , propping etc remove of form for ,foundation footing ,base of column etc for mass concrete
Providing tor steel reinforcement of 10mm,12mm & 16mm bars as per approved design and drawing.(a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
(b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Rate per cum for grading-III Material
Providing and laying in position specified grade of cement concrete excluding the cost of centering and shuttering - All works upto plinth level. : 1:2:4 (1 cement: 2 coarse sand(zone III):4 graded stone concrete 20mm nominal size)
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : (Screened through sieve of I.S. designation 4.75 mm)
Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot / Plastic Pot.
Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
Rabbit Dustbin
bench with backrest Wooden/ Treated Bamboo/ Bamboo composite planks Fitted in cast iron frame Painted/ Polished with protective laquer coat
Providing and stacking of Tecoma gaudichaudi of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Thuja compacta of height 45-60 cm., well branched in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Ipomoea purpurea (Morning glory) of height30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and stacking of Petra volubilis of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l .
Providing and fixing 15 mm dia male ended C.I .Body brass spindle valve and seat bib cock of approved quality (wt not less than 400 gms ) with extra socket all complete as per specification and direction of E/l .
Providing and fixing brass / C.I. Stop cock of approved quality all complete as per specification and direction of E/l .A) BRASS STOP COCK (a) 15 mm dia
(b) 20 mm dia
Providing and fixing 15 mm dia and 45 cm. long P. V .C connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of E/l .
Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l (a) 15 mm dia wt not less than 300 gms
(a) 20mm dia wt not less than 400 gms
(a) 25 mm dia wt not less than 500 gms
(a) 32 mm dia wt not less than 700 gms
(a) 40 mm dia wt not less than 1kg
(a) 50 mm dia wt not less than 1.5 kg
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l. (a) Glass shelf with C.P brass rail 1) 600 x 125 mm
(b) Mirrors of 4 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirror (1)600x450 mm
Supplying labour and tools for laying and jointing UPVC pipe and making joints with UPVC collar and solvent cement including … as per specification and direction of E/I 90/80 mm
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion. 110mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion. Coupler 110 mm dia
Single Tee with door
Bend 87.5 deg 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion. PVC Shoe
Providing and fixing unplasticised- PVC pipe clip of approved desing to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwes with M.S. Screw of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse sand ) and making good the wall etc. complete.110mm dia
U-PVC Pipes (working pressure 4 kg/cm2) single socketed pipe 75mm dia
U-PVC Pipes (working pressure 4 kg/cm2) single socketed pipe 110mm dia
U-PVC Pipes (working pressure 4 kg/cm2) rubber seal 75mm dia
U-PVC Pipes (working pressure 4 kg/cm2) rubber seal 110mm dia
U-PVC coupler for UPVE drainage pipe 75mm dia
U-PVC coupler for UPVE drainage pipe 110mm dia
U-PVC single equal tee (without door) 75x75x75
U-PVC single equal tee (without door) 110x110x110
U-PVC single equal tee (with door) 75x75x75
U-PVC single equal tee (with door) 110x110x110
U-PVC bend 87.5 degree 75mm bend
U-PVC bend 87.5 degree 110mm bend
U-PVC plain shoe 75mm
U-PVC plain shoe 110mm
U-PVC pipe clip 75mm
U-PVC pipe clip 110mm
Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931. 15 mm nominal bore
Supplying pig lead at site of work
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams.
Providing and placing on terrace (at all floor levels) storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing white vitreous thin rim table top/support mounted wash basin of rectangular/oval/round shape of size 600 x 415 x 200 of jaquar/kohler/hindwar or similar approved make
Providing and fixing 600mm long tower rail weighing not less than 190 g of jaquar/kohler/hindwar or similar approved make
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high, 112mm distance from wall of standard shape and size weighing not less than 105 gms
Providing & fixing Sink Mixer with Swinging Casted Spout (Wall Mounted Jaquar model CON-319 KNB/approved equal) with 450mm long copper pipes & brass nuts.
Providing & fixing C.P. brass shower assembly consisting of wall mixer (Jaquar model no. CAN-281kn), wall flanges and shower rose (Jaquar 489) & pipe upto shower rose complete.
Providing & fixing Hand Shower (Health Faucet) with 8mm dia, 1M long PVC tube and wall hook. (Jaquar model no. ALD-573 L 1500).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. . Internal Work - Exposed on Wall 15 mm nominal outer dia pipes.
20 mm nominal outer dia pipes.
25 mm nominal outer dia pipes.
32 mm nominal outer dia pipes.
40 mm nominal outer dia pipes.
50 mm nominal outer dia pipes.
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia pipes.
20 mm nominal outer dia pipes.
25 mm nominal outer dia pipes.
32 mm nominal outer dia pipes.
Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This including jointing of pipes & fittings with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge. 40mm Nominal outer dia pipes
62.5mm Nominal inner dia pipes
Providing, fixing, installation, testing and commissioning of Solar Hot Water indirect Heating system using approved type of heating liquid medium comprising of flat plate solar panels, with single sheet absorber fin ,screw less construction of panel,including all interconnecting insulated GI piping, primary and secondary recirculation pumps, pressure type insulated hot water tank wit PUF insulation, sacrificial magnesium anode with steel core including valves on inlet, outlet, Y strainer and a water meter on the inlet, air release valve all mounted on galvanized MS sections complete as required with connection with existing piping. (connect the system to hot water mixing tank via 50 mm dia pipe) (make: Solarhart ,Tata BP ).
Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB . Group C
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB/HPL
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. Make-Havells/ Legrand/ Polycab/ C&S/ Hager/ABB /HPL/Anchor
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Wiring for power plug with 2x4 sqmm FR PVC insulated copper conductor single core cable in recessed PVC conduit alongwith 1 No. 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.( Make-Polycab/Incab/Mescab/Havells/ KEI/RR Kable) 2x1.5 Sqmm + 1x1.5 sqmm earth wire
2x2.5 Sqmm + 1x2.5 sqmm earth wire
2x4 Sqmm +1x4 sqmm earth wire- for LDBs & UPS DBs
2x6 Sqmm +1x6 sqmm earth wire- for PDB
4x6 Sqmm + 2x6 sqmm earth wire- LDBs & UPS DBs
4x10 Sqmm + 2x6 sqmm earth wire PDBs
S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 AMPS, one way switch
5/6 Amps, 3 pin socket outlet
TV antena socket outlet
S/F Modular Boxes, base & cover plate: Supplying and fixing following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (75 mm x 75 mm)
4 or 5 module(78 mm x 140 mm )
8 or 9 module(78mm x230mm)
Ceiling Rose: Supplying and fixing 3 pin,5 amp ceiling rose on existing junction box/wooden block including connection etc as required.
Supplying and fixing the follwing way single pole and neutral sheet steel M.C.B distribution board, 240 volts in surface/recess, completed with tinned copper busbar, neutral bus bar, earth bus bar, din bar, interconnection including earthing etc. as required(without MCB/RCCB/Isolator). Make-Havells/Legrand/ Polycab/ C&S/ Polycab/ABB / HPL 12 ways, double door( UPS=2, LDB=1, PDB=1)
Supplying and fixing the follwing way Three Pole pole and Neutral Sheet steel M.C.B distribution board, 415 volts in recess, completed with tinned copper busbar, neutral bus bar, earth bus bar, din bar, hinged front acrylic cover from MCB Knob detachable gland plate, interconnection including earthing etc. as required(without MCB/RCCB/Isolator). 4 way(4+12) Double door Horizontal type( UPS
6 way(4+18) Double door Horizontal type((PDB=3)
8 way(4+24) Double door Horizontal type(LDB=5 , PDB=2)
S/F 'C' series SP MCB: Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. 6/32A Single Pole
40A DP MCB
63A DP MCB
40A TPN MCB
63A TPN MCB
S/F TPN RCCB: Supplying & fixing following rating, TP&N 415 V, residual current circuit breaker(RCCB) , having a sensitivity current upto 300mA in existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps for lighting DBS+UPS DBs
63 Amps for power DBs
Supply and Fixing testing and commissioning of three pole and neutral, sheet, MCB distribution board, 415V, copper bus bar, earth & neutral bar, removiable gland plates, cable glands including connections with outgoing feeders complete all respect. ( but without MCCBs & MCBs) 4 way(8+12) Double door Vertical type
S/F 'C' series SP MCB: Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. 40A TPN
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 kA, FP MCCB as incomer of VTPN DB
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size on wall surface as required. upto 55 sq.mm( clamped with 1mm thick saddle)
1.1kV Cable End Termination: suppluing and fixing indoor cable end termination with brass double compression gland and AL lugs of following sizeAl armoured cables. 3.5Cx25 sq.mm
3.5Cx35 sq.mm
BLDC Ceiling Fan: Supplying , installation, testing and commissioning of 1200 mm (48")Sweep BLDC 5 star, 32W AC ceiling fan confirming to IS:374:2019 , including connection with 1.5 sq mm copper wire, down rod of standared length(upto 30cm) withall accessories as required. Make :- Polar/Bajaj/Crompton / Havells / GEC
Exhaust metal Fan 230mm(9"): Supply , installation and commissioning of 230mm(9"), 230V AC metal exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required( Make- Polar/ Havells/Crompton/GE)
LED tube with Batten 20W: Supply , installation and commissioning of wall mounted LED 20W tube light suitable for 230V, single phase supply voltage, with all accessories like batten and electronic driver others as required. ( Make -Bajaj/ Havells/ Philips/ Jaquar)
Surface/Recess mounted 20W LED round : Supply , installation and commissioning of Environmental friendly, new generation,aesthetically designed, ultra modern surface/recess mounting luminaire with high brightness 20W LEDs as light source.( make : Havells /Bajaj/ Wipro/Jaquar)
LED Flood Light 150W:Supply installation Testing and Commissioning of LED flood lighting( 150W ) luminarie with prssure die cast housing and toughened glass cover (IP-66 protection in existing pole/ pipe for supply voltage 100-270 volts AC, 50Hz. Luminarie shall confirming to IS:10322 part-5/ section -5 and shall be conecessary accessories as per required. ( Make -Wipro/Bajaj / Havells/ Jaquar)
Supplying Fixing Lift of Following Specificaion 13 passenger:- PRODUCT:-GeN2-Nova or equivalant, DETAILS, GeN2-Nova VXN, CAPACITY (kgs)-884 Kg, 13 persons. , SPEED (mps)-1 mps, RISE (m)-14.4 m, STOPS-3 Stops With (all opening on the same side), CONTROLLER TYPE-ACD3-MR, DRIVE-VF Regenerative (Closed Loop), POWER SUPPLY-400/415 Volts (3 Phase AC), OPERATION-Full collective operation, CAR GROUP-One car (simplex), MACHINE- PM Gearless (Located above shaft), TRACTION MEDIA-Flat Coated Steel Belt, CAR FINISH-•Rear Mid Panel = Stainless Steel #4(Hairline) • Rear Corner Panels = Stainless Steel #4(Hairline) • Side Panels = Stainless Steel #4(Hairline) • Front Panels = Stainless Steel #4(Hairline), FALSE CEILING TYPE-CD-41, FLASE CEILING FINISH-Stainless Steel #4(Hairline), VENTILLATION-Cross flow fan, HAND RAILS-Stainless Steel Mirror Finish Handrails on rear car panels, FLOORING-Vinyl Tiles, CAR DOOR FINISH-Stainless Steel #4(Hairline), LANDING DOORS FINISH, Stainless Steel #4(Hairline), FIRE RATED DOORS-Fire rating-60mins , PIT DEPTH-1350, OVERHEAD-4500, HOISTWAY DIMENSIONS (W x D – mm), 1800 mm W x 2100 mm D, CAR DIMENSIONS (W x D x H - mm)- 1650 mm W x 2000 mm D x 2200 mm H, CAR & HOISTWAY DOOR TYPE-Central opening (CO) doors, DOOR OPENING (W x H - mm)-1100 mm W x 2000 mm H, DOOR OPERATOR-DC Door Operator, COP-COP for stops <= 12 (950mm) in Stainless Steel #4(Hairline), CAR POSITION INDICATOR-Monochrome LCD-Blue Background & White font, HALL FIXTURES-O2000, HALL FIXTURE FACE PLATE-Stainless Steel #4(Hairline), HALL BUTTON ARRANGEMENT-Hall Button with HPI, STANDARD FEATURES-Anti-nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut OfF, OPTIONS INCLUDED, Automatic Rescue operation.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required: brackets) in side the hose cabinet.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:Gun metal
Supplying and fixing first-aid Hose Reel 40m with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type-2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket
1 no. lengths of 15 M long, 63mm dia Thermo plastic (Sutaible for Pn 25) hose with instantaneous couplings and Hoses shall be stored (shall be hang onSupplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required: brackets) in side the hose cabinet..
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:Gun metal
1 no. pre fabricated weather proof lockable cabinet of size not less than 750x600x250mm made out of MS sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two No.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade. As per approvel dwg. etc.
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity. Providing ,fixing , testing and commissioning of Portable Carbon-di-oxide Gas Type Fire Extinguisher 4.5 Kgs, squeeze Grip,Controllable discharge mechanism with nozzle, bend, Hose and wall mounting bracket etc.The Can is made of Seamless Clinger and External Coating done by Spray Painting.The thickness shall not less than 4.5 mm made of Sheet metal.The Fire Extinguishers shall be ISI Approved as per IS 15683:2006.Vendor shall consider the suitable signages along with the extinguishers.
Supply and install in position approved make ABC Stored pressure type Fire Extinguisher of 6 kgs capacity, fitted with discharge control valve (sq.grip type) CE marked and pressure gauge, filled with mono ammonium phosphate powder as per EN 3 615 approval, with discharge hose and open nozzle and supplied complete with initial charge as per IS: 15683 with ISI mark and wall bracket.
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.
Floor identification Signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 4 zone panel
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Sand (LEAD 10 Km)
Bricks (Lead 8 KM)
FLY ASH BRICK (Lead 8 Km)
Cement (Lead 3 Km)
STONE AGGREGATE(Lead 35 Km)
Add 18% GST
Add 1% Labour cess 1%
M/S S.S. ENTERPRISES (BID ID -657420)
M/S SETH KUMAR (BID ID -657612)
stage.html
html • 0.05 MB
technical_134578.pdf
techsummary_134578.pdf
finance_134578.pdf
BOQ Comparative Chart
xlsx
finsummary_134578.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
SBD-127.pdf
Tender Documents • 9.40 MB
BOQ_134578.xls
BOQ • 0.41 MB
BOQ.xls
BOQ • 0.41 MB
Tenderdocument.pdf
Tender Documents • 9.40 MB
Download all tender documents and submit your bid