| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹27.9 L+₹9,878 (0.36%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹28.4 L+₹63,054 (2.27%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹32.0 L+₹4.2 L (14.9%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹33.0 L+₹5.2 L (18.6%)Rejected-Finance | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
8 May 2021, 6:00 pmClosed
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
REPAIR REPLACEMENT OF EXTERNAL ELECTRICAL WATER SUPPLY AND OTHER CONNECTED WORKS AT DGBR AREA UNDER GE WEST DELHI CANTT 10
2021_MES_426909_1
GE/DW-57/2021-22
Open Tender
Civil Works
Item Rate
270 days
DGBR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹99,000
29 May 2021
8 Apr 2021
10 May 2021
9 Apr 2021
8 May 2021
26 Apr 2021
Amount
Disconnecting HT/LT sides of defective transformer of indoor/outdoor installed on PCC foundation of any capacity up to 630 KVA and then drainage of complete transformer oil. Opening of top cover with due care and removal of all HT/LT winding connections from bushing and then lifting of core by means of tripod and chain pulley with due care for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required replacement of HT/LT bush. In case the repairs which are not possible at site then the transformer has to be taken to the work shop for repairs complete all as specified and as directed. Note :- (a) The cost of following items shall deemed to be included in the quoted rate of this item:- (i) The cost of transportation. (ii) The cost of rewinding HT/LT coils. (iii) The cost of replacement of spares required for making transformer serviceable. (b) The following items shall be measured and paid separately under relevant items of the BOQ/Sch ‘A’:- (i) The cost of dehydration/filtration’ (ii) The cost of transformer oil .
Dehydration/filtration of transformer oil by centrifuging machine electrically operated including testing of transformer oil before and after filtration by means of oil testing machine, keeping the electrodes at 2.5 mm gap and to achieve die electric strength of filtered oil 50 KV and above complete all as specified and directed.
Supply and topping up transformer oil conforming to IS : 335 and withstand dielectric strength of 60 KV (when tested with 2.5 Gap electrode) complete all as specified and directed.
M&L for excavation in trenches in soft soil n.exc 1.5 Mtr wide and n.exc 1.5 meter in depth for laying of cables/pole etc and getting out, trimming the site, forming bottom surface to required level complete all as specified and directed.
M&L for returning filling-in trenches including spreading leveling watering and well ramming in layers in soft/loose/dense soil n.exc 25 cm thick in each layer of soil, complete all as specified and directed.
M&L for removing excavated soil to a distance n.exc 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed.
M&L for sand cushioning with a layer of sand (Yamuna) 23 cm thick punned thickness (8 cm under and 15 cm above the cable) in trenches around the cable complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable covers for cable protection of class LV type 1 flat of size 250 x150 x 40 mm complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning XLPE insulated armoured heavy duty PVC sheathed LT 1100 volts grade cable with stranded aluminium conductor of size 3.5 core, cross sectional area 240 sqmm.
ditto - but sectional area 185 sqmm.
ditto - but sectional area 150 sqmm.
ditto - but 4 core, sectional area 35 sqmm.
ditto - but 4 core, sectional area 16 sqmm.
M&L HT Cable jointing kit for 11 KV(Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size up to 240 Sqmm complete all as specified and directed.
M&L HT Cable jointing kit for 11 KV(Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 240 Sqmm. complete all as specified and directed.
M&L for GI pipe light grade galvanized with all fittings, laid in trenches/poles with a size of 50 mm bore complete all as specified and directed.
ditto- but 40 mm bore .
M&L in repair for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) in repair with top edge of the plate not less than 1.5 meter normal ground level, connected to galvanised iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints all as shown in electrical plate no 3 of SSR Part I including excavation and earth work, GI pipe light grade 15 mm bore for protection of earth strip from earth electrode & GI funnel and wire mesh, 20 mm dia GI pipe light grade for wateringand including finnel wire mesh RCC pit cover and PCC chember pit with RCC 1:2:4 B1 including exavation and earth work all as shown in electrical plate no 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified and directed. Note:- (a). PCC pit shall be provided at list 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (b). RCC pit cover shall be of pre-cast RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sq m in lieu of cast iron cover
Supply installation, testing and commissioning MCCB 4 pole suitable for AC 3 phase 415 volt, 400 Amp, 36 KA, with thermal magnetic release fixed in repair on existing LT panel complete all as specified and directed.
do- but 350 Amps,4 pole 36 KA with thermal magnetic release.
do- but 250 Amps, 4 Pole 36 KA 4Pole with thermal magnetic release.
do- but 200 Amp, 4 Pole 36 KA with thermal magnetic release.
do- but 160 Amps,4 pole 36 KA with thermal magnetic release.
do- but 125 Amps, 4 Pole 16 KA 4Pole with thermal magnetic release.
do- but 25 TO 100 Amps, 4 Pole 16 KA with thermal magnetic release.
M&L for jointing LT UG cable with LT 1100 volts straight through joints kit epoxy type of size 16 to 35 sqmm 3.5 core complete all as specified and directed.
All as per item 26 but heat shrinkable type of size 150sqmm to 240 sqmm 3.5 core.
Supply and fix in repair time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V, single phase of 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and directed.
Supply and fix in repair 3 Pole power Contactor AC3 type having 18 Amps rating with click fit DIN construction complete all as specified and directed.
Supply and fix Bus bar chamber (kiosk box) made out of 16 SWG MS Sheet having front Openable shutter with locking arrangement of size 20 CM X 15 CM X 10 CM depth duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and provided with one SP MCB 6 Amp & four NO's 63 Amps rated aluminium bus bar strips fixed on porcelain insulator fixed to pole with and including MS Flat iron clamps 40 X 4 mm size with nuts,bolts,washers etc all as specified and directed.
M&L for writing of machine numbers on E/M plants with approved colour of paint, (not more than 15 digits) each letter of size not more than 25mm complete all as specified and directed.
Preparation of old surface of outdoor feeder pillar box of size not more than 2x1.5x1 metre size for painting externally removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformer complete all as specified and directed.
Supply & Fix in repair gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed, bore of pipe of following sizes complete all as specified and directed. :-
20 mm bore dia
40 mm bore dia
50 mm bore dia
M&L in replacement of pressure gauge suiable for delivery line with pressure range from 0 to 10 kgf/cm2 with 2% accuracy complete all as specified and directed.
M&L for dismantling of impeller of centrifugal pump and replacement of the same with bronze impeller closed vane type suitable for 10 Hp centrifugal pump complete all as specified
M&L for disconnecting of battery charger of DG set 100 KVA and replacement of diods, circuit plate of transformer of battery charger as required complete all as specified and directed.
M&L in replacement MCB triple pole and neutral 63 Amp 415 volt 10 KA complete all as specified and directed.
M&L for of GI pipe 20 mm bore, medium grade including all fittings such as tees,elbows,bends,sockets and nipples fixed to wall by means of clamps and other accessories incl of taking down of old unservicable pipe complete all as specified and directed.
All as per item 45 but 40 mm bore.
All as per item 45 but 50 mm bore.
All as per item 45 but 80 mm bore.
M&L in replacement foot valve (flanged type) of size 100 mm including packing,nuts,bolts and washers complete all as specified and directed.
M&L for taking out/ down of electric mortar from foundation, taking it to workshop for repair, dismantling and taking down of winding of motor and rewinding of electric motor 10 HP capacity with appropriate size of super enamelled copper winding wire as recommended by manufacturer including insulation varnish and paper etc and testing and refixing at site complete all as specified and directed.
S&F in replacement fully automatic star delta starter suitable for motor of capacity 10 HP including contactors and wiring with suitable size of copper wire complete all as specified and directed.
Material and labour for CI butterfly valve of following sizes, stainless steel disc, gear mountable as per 13095 Class PN-1.0 complete with nuts, bolts, washers and rubber gaskets including taking out old unserviceable butterfly valve complete all as specified and directed:-
100 mm bore
80 mm bore
50 mm bore
M&L for valves pit chamber having internal dimentions 90 cm x 90 cm x 90 cm (internal height), PCC (1:4:8) using 40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick Brick wall in CM (1:4), 10 mm thick rendering all around the brick work with cement mortar 1:6 , PCC (1:2:4) type B1as in coping with 20mm graded stone aggregate for grouting MS frame including 1.8 mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame made out of 40 x 40 x 6 mm thick angle iron including preparation and painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer, including necessary excavation/ earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed.
M&L for disconnecting incoming & outgoing HT connections of electric Panel, servicing the HT OCB, 400Amp, including the following and commissioning, testing complete panel on load after making all cable connection all as directed by Engr in Charge:- (a) testing and adjesting of IDMT relay-01, (b) painting the complete panel (inside and out side complete) with 2coats synthetic enamel pait (duco paint) -01, (c) complete wiring of HT breaker 01, (d) M&L for replacement of power pack 240V Make scan or equivalant (DC) - 03 Nos, , (e) M&L replacement of CT for HT OCB of raito 100/50/5+5, Make CG Nos - 01 Nos,, (f)M&L for replacement of spought bushing for OCB -06 Nos, (g) M&L for replacement of trip coil assy 24v DC - 04 Nos, (h) M&L for replacement of indicator for LED type - 12 Nos (j) M&L for replacement of space heater- 05 Nos, (k) M&L for replacement of flexible bus 800 Amps -01Nos,
M&L for switches air break (as per sample) 11000 Volts, triple pole mechanically opreted , mounted on insulator and steel frame, with oprating mechanism worked from ground level for current rating upto 200 Amps complete all as specified and directed.
M&L for on load changeover (as per sample) with advance neutral 630 Amp AC 415V,50Hz complete all as specified and directed.
M&L for on load changeover(as per sample) with advance neutral 320 Amp AC 415V,50Hz complete all as specified and directed.
M&L for on load changeover(as per sample) with advance neutral 200 Amp AC 415V,50Hz complete all as specified and directed.
Supply and laying XLPE cable PVC insulated armoured and heavy duty PVC sheathed LT 1100 volts grade with stranded aluminium conductor of size 3.5 core 50 sqmm complete all as specified and directed.
Supply and lay XLPE cable PVC insulated armoured and heavy duty PVC sheathed LT 1100 volts grade with stranded aluminium conductor of size 3.5 core 70 sqmm complete all as specified and directed.
Supply and laying XLPE cable PVC insulated armoured and heavy duty PVC sheathed LT 1100 volts grade with stranded aluminium conductor of size 3.5 core 95 sqmm complete all as specified and directed.
M&L for taking out submersible pumping set from well including column pipe of any bore, opening of the submersible electric motor 10 HP capacity and taking it to workshop for repair, rewinding of motor using copper winding wire as per existing Nos of approved size, & replacement of unserviceable item such as insulating materials, seal, nuts bolts, bearing etc and lowering the submersible pump set alongwith column pipe complete all as specified and directed.
Taking out 50mm bore GI Column pipe of any description and S&F for GI pipe 50 mm bore, heavy grade flanged on both sides fixed with new nuts & bolts, washers, gasket packings, etc. and testing complete all as specified and directed.
Taking out of submersible cable of any description and S&F for submersible cable of size 16 sqmm 3 core PVC insulated and sheathed 1100 Volts grade complete all as specified and directed.
Supply and fixing of New 90 watt LED fitting for street light on pole complete with electronic drivers and other accessories prewired complete all as specified and directed. Make: Havells cat pt No. SL90WLED757SASYBOTG or equivalent in Bajaj/Philips/Crompton Greaves/C&S Electric/Halonix
supply and fixing in repair LED drivers suitable for 90W outdoor road way luminaries complete all as directed and specified
Supply and fixing CORAL (OPAL) IP65 New generation Post Top Lantern ,energy saving environmental frindly, long life aesthetically designed with semetrical light distribution, spum aluminium landscape luminaire with high power LEDs as light source Cat Part No LHEVBHP7PN6K025 or equivalent in Bajaj/Philips/Crompton Greaves/C&S Electric/Halonix complete all as specified and directed.
Supply and fixing Flood light Jeta Compacto 50W Energy saving IP65 High power COB LED as light source Havells Cat Part No FL50WLED757LTG complete all as specified and directed. Make Havells or equivalent in Bajaj/Philips/Crompton Greaves/C&S Electric/Halonix
Supply and fixing Time switch analog type (with battery back up) 3 pole module DIN mounting type 24 hrs program,programmable every 15 minute 16 Amp with 63Amp Contactor 1 change over complete all as specified and directed. Make: Indo Asian/L&T/Havells.
M&L for claning of under & over ground RCC water sump of cap 30000 gallon thoroughly by scrapping/removing setteled silt on the wall and bottom surface washing with clear water after removing silt ,grass etc including colour wash as per existing colour on outer surface of the sump complete all as speciifed and directed.
Supply and fix in repair 12 Volt 150 Amp New Inverter battery suitable for 1000 VA capacity inverter complete all as directed and specified.
M&L for complete removal of existing treatment of old painted steel surface of LT pole /strut along with nut ,bolts etc and appling one coat of red oxide primer and two coat of aluminiam paint including writing pole number with black synthetic enammeled paint and making alternative strip of black ,white and yellow paint from coping of pole to height of 0.50 mtr(as per existing) complete all as directed.
M&L in replacemnt of water level indicator mechanical type having indicators making an every steps indicating 100 galon of a gap made out of angle iron 40x40x6mm and 16SWG steel wire rope ,pully ,and float as per existing size and length including complete water lavel indicator with and including 2 coats of synthetic enamal paint over a coat of red oxide primer after prepration of steel surfaces complete all as specified and directed .
Deduct Credit: for demolished/dismantled material of (-) Rs 187600.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
M/S ANIL KUMAR
M/s Adhikari construction co.
SETHI ENTERPRISES
jain associates
JAMDAGNI ENGG WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .