Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.1 L+₹35,657.80 (3.64%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.1 L+₹5.3 L (54.1%)Rejected-Finance H NO 13149 STREET NO 3 SHIV COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
17 Mar 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Niranjan Lal GE(S) BTD
GE(S) Bathinda Bathinda Mil Stn
PERIODICAL SERVICES AND REPAIRS TO CHAJJAS PARAPETS ETC OF CERTAIN BLDGS INCLUDING RELATED BR WORKS IN BASANT BAGH AND BANA SINGH ENCLAVE UNDER AGE BR II UNDER GE(S) BATHINDA AT BATHINDA MIL STN
2021_MES_424042_1
GE(S) BTD-51/2020-21
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Stn
AS PER NIT
8 documents required · 8 mandatory
₹500
GE(S) Bathinda
₹50,000
Yes
23 Mar 2021
20 Feb 2021
19 Mar 2021
20 Feb 2021
17 Mar 2021
4 Mar 2021
20 Feb 2021 - 25 Feb 2021
60 days
Amount
Preparing of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing, scraping down smoke soot, moulds, mass and efflorescent, salt and trading oil and greasy spouts and applying one coat of white wash with spray machine and making good by roller if required on walls including cornices etc complete all as specified and directed
M&L for applying each subsequent coat of white wash after applying first coat of white wash, complete all as specified and directed. Note : First coat of white wash shall be measured and paid separately under item 01 above.
Preparation of old plastered or unplastered old decorated surfaces of ceiling by brooming for down or steel wire brushing, scrapping down make spots, trating oily/greasy spots, mass and efflorescence and applying one coat of white wash on ceiling including cornices etc complete all as specified and directed.
M&L for applying each subsequent coat of white wash on ceilling surface after applying first coat of white wash, complete all as specified and directed. Note : First coat of white wash shall be measured and paid separately under item 03 above.
Preparation of old (Previously treated) plastered or unplastered surfaces of walls by washing, rubbing down and stopping of distempered or painted surfaces of walls and applying one coat of Oil Bound distemper white or tinted on walls complete all as specified and directed.
M&L for applying each subsequent coat of OBD after applying first coat of OBD on wall surfaces, complete all as specified and directed. Note : First coat shall be measured and paid separately under item 05 above.
Preparation of old plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smake soot, moulds, mass and efflorescent salts and trading oil and greasy spouts and applying one coat of cement base paint on walls including cornices etc complete all as specified and directed.
Preparation of old plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smake soot, moulds, mass and efflorescent salts and trading oil and greasy spouts and applying one coat of weather proof exterior emultion on walls including cornices etc complete all as specified and directed.
Taking down cement plaster on wall and ceiling surfaces including chhajjas and parapets etc. in patches including racking out joints, hacking for key and scrubbing down with water
M& L rendering 15mm thick in CM (1:4) on other than fair face of brick work or concrete surface finishing even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M& L rendering 15mm thick in CM (1:6) on fair face of brick work or concrete surfacefinishing even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M& L rendering 5mm thick in CM (1:3) on concrete surface and finishing even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for applying three coats of white wash with spray machine and making good by roller if required on prepared walls surfaces including cornices & pillasters etc.; complete all as specified
M& L applying two coats of Oil Bound distemper with spray machine and making good by roller if required on prepared old or newly plastered surface on wall etc over a coat of primer including prepration of new surface complete all as specified
M & L for applying three coats of white wash with spray machine and making good by roller if required on prepared ceiling surfaces incl cornices & pillaster etc including prepration of new surface complete all as specified.
M&L for applying two coats of cement base paint with spray machine and making good by roller if required over a coat of primer on newly plastered wall and ceiling surfaces including cornices & pillasters etc including prepration of new surface all as specified
M&L for painting with one coat of synthetic enamel paint of approved tint and quality on old painted wood and wood based surfaces of any description exceeding 10cm width or girth after preparing the surfaces of any description exceeding 10cm width or girth after preparing the surface etc complete all as specified and directed by engineer-in-charge
M&L for painting with one coat of synthetic enamel paint of approved tint and quality on old painted steel surfaces of any description exceeding 10cm width or girth after preparing the surfaces of any description exceeding 10cm width or girth after preparing the surface etc complete all as specified and directed by engineer-in-charge
M&L providing cement concrete (RCC/PCC) 1:2:4, type B0 (12.5mm graded agrregate) as in broken or cracked Chhajjas, RCC columns, beams, stairs/steps,PARAPETS etc in one or two layers as required (thickness from 25mm to 40 mm) and finshing the surface with 15mm thick cement plaster in CM 1:4 including taking out loose/cracked concrete portions and applying neat cement slurry before providing concrete, complete all as speicified (Note : 1. Rates deemed to include for any scaffolding/ ladders or any other mean to work in three story buildings 2. Reinforcement if required to be provided for repairs of chhajjas, beams, columns, stairs etc will be measured & paid in subsequent item separately )
M&L for mild steel TMT bars 8 mm dia and over, cut to length bent to shape required including cranking, bending spirally etc and binding with mild steel wire not less than 0.9 mm dia or welding to old reinforcemnt in repairing chhajas, beams, coloumns, step/stair etc, as in reinforcement etc.complete all as specified
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces with wall putty and preparation of surfaces for further treatment etc complete all as specified and directed by Engr-in-charge.
M&L applying three coat of white wash on old surfaces of wall surface already prepared under item No 21 above complete all as specified.
M&L for applying two coat of Oil Bound distemper over a coat of primer of approved tint on old surface of walls already prepared under item no 21 , complete all as specified.
M&L on wall surface prepared under item no 21 above as under :- (a) Applying wall care putty coat on wall surface and smoothening the surface with sand papers/Mechanised sanding etc prepatory to paint. (b) Two coat of Oil Bound distemper over a coat of primer by using Airless spray/Roller over complete all as specified and directed.
M&L for applying two coat of cement base paint including cornices on wall surface already prepared under item No 21 above complete all as specified and directed.
M&L on wall surface prepared under item no 21 above as under :- (a) Applying wall care putty coatson wall surface and smoothening the surface with sand papers/Mechanised sanding etc prepatory to paint. (b)Two coat of weather proof exterior emulsion over a coat of external emulsion primer by using Airless spray/Roller over complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of any description over 10 cm girth or width, not otherwise described and applying one coat of synthetic enamal paint on plastered surfaces walls, complete all as specified and directed. surfaces.
M&L for applying each subsequent coat of synthetic enamal paint after applying first coat , complete all as specified and directed. Note : First coat of white wash shall be measured and paid separately under item 27 above.
M&L for cleaning the apparent visibe efflorescence using hard wire brush and all crystal deposits to be remove, the bricks shall then be cleaned using soft brush of powdery crystals removed then make a 1 to 4 solution of vinegar & water (1 part vinegar to 4 part water) and apply it to the efflorescence effected area using a nylon brush allow the vinegar/water solution to sit on the surface of the effected area for 15 minutes but do not allow the solution to dry, rinse the area with clean water using low pressure jet. Two cycles of cleaning using vineghar water solution to be repeted etc complete all as specified and directed.
M&L for cleaning the joints of bricks be pointed using cement putty made at site using latex /SBR polymer diluted at ratio (1: 4) with water the solution so made shall be used to mix with cement to make a putty consistency paste the cement putty shall then worked in the cement which are cleaned and in SSD condition etc complete all as specified and directed. Make Sikka / BASF / STP
M&L for cleaning the bricks so pointed to all dust or deposit using brush. A undiluted single component acryalic polymer to be used to prime the brick surface. The primer while being Tacky the first Coat of waterproofing coating is done, second coat is applied after a time interval of 4 to 6 hours after the first Coat has dried the waterproofing coating shall be two component polymer modified cementatious coating having a thickness of 1.5 mm two coat the material to be factory batched and ready to use. the two components shall be mixed using low speed drill having a RPM 350 to 450 and fitted with a paddle. The mixing to be done for 3 to 4 minutes to give a brushable consistency mix. the coating shall be done using 100 to 150 mm wide brush it is to be take care that the material while being used a agitated every 3 to 5 minutes to avoid powder part getting settled. the waterproofing coating shall have properties as below: tensile STR must be 4.5 N/ mm square after 14 days of exposure and Bond strength must be of 2 N/mm square at +27 C (bracket failure in substrate ). After application of second coat and while the material is still wet, course sand is sprinkled over the coating so as to ensure proper and chemical key to provide for subsequent plaster, complete all as specified and directed. Make Sikka / BASF / STP
BALAJI CONSTRUCTIONS
M/s Verma Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .