| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹45.6 L+₹3.6 L (8.46%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹46.0 L+₹4.0 L (9.43%)Rejected-Finance 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 UDYAM CG 01 0003803 | BASTAR | CHHATTISGARH | 494001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.7 L+₹4.6 L (11.0%)Rejected-Finance 143 ALLAHABADPUR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹47.7 L+₹5.7 L (13.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹41.1 L
EMD Value
₹82,300
Closing Date
9 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
PROVN OF AC FOR GDCC AND SPL REP OF TRAFFIC LIGHT AT AF STN GORAKHPUR
2023_MES_613440_1
9079/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(AF) GORAKHPUR
Class D Cat b i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹82,300
Yes
6 Oct 2023
12 Aug 2023
11 Sept 2023
12 Aug 2023
9 Sept 2023
26 Aug 2023
12 Aug 2023 - 19 Aug 2023
Amount
Supply, laying in repairs and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed at site.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed at site.
Supply and laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches/pipes or laying in floors complete of size 40 mm bore including all fittings complete all as specified and directed at site.
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil.complete all as specified and directed at site.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point.complete all as specified and directed at site.
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed.
Supply and laying in trenches dry well burnt locally available sub class “B” bricks over sand cushioning for protection of cable complete all as per specified and directed.
Material & Labour for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation, filling and mass concrete of poles/stay assembly/ panels etc. complete all as specified and directed at site.
Material & Labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in form work/coping of poles. complete all as specified and directed at site.
Supply, laying in repairs & fixing galvanised steel tubing 32 mm bore "light grade" (Make -QST/ TATA / JINDAL) with GI fittings in trenches/ under roads/ along pole/ wall including FI (25 mm x 6 mm ) clamps as required for cable protection all as specified & directed by EIC.
Supply and fix in repairs LED Traffic Light fitting 8 W IP 65 , 230 V Make: 3M / Dark eye/ hAVELLS/PHILLPSWipro/Bajaj
S & F in repairs TPN MCB 4 Amps, all as per legrand cat Part No : 408670 equivalent complete all as specified and directed at site. Make : Schinder/Havells
Supply and install and testing split type air conditioner of capacity 1.5 Ton, BEE 5 star rating, for working on 230 volt, SP, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface with existing surface if required and providing water pipe upto ground level complete all as specified and directed. Make: Carrier/Voltas/Bluestar/Hitachi/LG
Supply & Fix Voltage stabilizer automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilzed at 230 V with accuracy of +-2.5% and of capacity 5.0 KVA Make : Voltas, Microtech, Blueline, Logicstate.
Supply & Fixing earth plug enclouser (plug and socket) with MCB, 2P+E with "C" Curve MCB of capacity 32 Amps.complete all as specified and directed.
Supply & fixing amp rating 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commisioning SPN 40 to 63 Amp.
S & F for sub main wiring with two run of 6.0 Sqmm and one run of 4 Sqmm PVC insulated unsheathed copper cable drawn for earth wire drawn in and including PVC rigid surface conduit non metallic 25 MM dia and making good distributed complete all as specified and directed by Engg in Charge.
M&L in repairs earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in to ground to a depth not less than 1.5 meters below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or riveted to earth plate at one end and connected to equipments at another end, GI 'light grade' pipe from upper end of earth plate up to equipments, 20 mm dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6 mm dia @ 100 c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part-I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is less than 5 ohm not found, earthing shall be redone by the contractor at no extra cost the department.
m/s allied enterprises
sanjay enterprises
Sanjai sales and services
M/s Mahendra Construction
M/S APARNA ASSOCIATES
M/s Aman Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .