| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC ADHANGAGARH ANAKHIA AT PO JAGATSINGHPUR 754102 | JAGATSINGHAPUR | ODISHA | 754102 | ₹8.2 L Quoted ₹6.9 L | L1 | Accepted-AOC technocommercially eligible L1 bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical Rejected for not uploading Partnership deed containing name of the partners in support of the legal status of the bidder i.e. Partnership Firm as per clause no. 9.a.3 of NIT. |
Tender Value
₹13.0 L
EMD Value
₹16,300
Closing Date
30 Sept 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Erection, Testing, Commissioning and Charging of 20MVA, 132-33KV Transformer, Make- ATLANTA with dismantling of old survey off Transformer 20MVA,132-33KV, Make- EMCO at 132-33KV Grid Sub-station, Nandira under JA, MCL
2024_MCL_317257_1
GM(JA)/EnM/e-Tender/24-25 /E-686/51 DTD. 11/09/2024
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
TALCHER
AS PER NIT
5 documents required · 5 mandatory
₹16,300
24 Oct 2024
11 Sept 2024
3 Oct 2024
12 Sept 2024
30 Sept 2024
12 Sept 2024
12 Sept 2024 - 17 Sept 2024
Amount
Scope of the work:- 1. Complete Erection, Commissioning, Testing & Charging Of 20MVA,132/33KV Transformer, Make: Atlanta as per instruction of Representative of OEM (Atlanta) & EIC. Placing of New Transformer at Bay No: TRF:01 by dragging and placing is under the scope of contractor. (Providing Tailer & Crane is under scope of MCL). 2. Dismantling of old 20MVA Transformer, Make: EMCO from BAY No: TRF:01 has to be execute by the contractor as per desired job at site. Shifting of the old transformer at a new place by Loading & Unloading of the transformer as per instruction of EIC. (Providing Tailer & Crane is under scope of MCL). 3. The works and execution shall be in line to the updated CEA, Reg.-2023 & complying all the directives of DGMS. 4. The contractor has to provide and ensure the use of all tools & tackles and safety appliances to his worker for the subject work.
NAS FILTRATION SYSTEM FOR TRANSFORMER OIL FILTRATION WITH APPLYING VACUUM & HEAT TO ACHIEVE BDV VALUE OF 70KV & MAINTAIN THE PROPERTIES OF OIL IN COMPLIANCE TO IS 1866:2000 achieve BDV Value of 60KV & maintain the properties of OIL In Compliance to IS 1866:2000 .
ERECTION, COMMISSIONING & CHARGING OF 20MVA, 132/33KV TRANSFORMER, MAKE: ATLANTA. Erection of 20 MVA 132/33 KV Transformer. Assembly of HV & LV Bushing. Assembly of Buchholz relay and oil serger relay. Assembly of Tertiary Bushing (If applicable). OLTC conservator Mounted, Assembly of Radiator. Pre-commissioning testing of Transformer.
PRE-COMMISSIONING TESTING OF TRANSFORMER. Insulation Resistance Test with Polarization Index, Voltage Ratio test, Magnetic balance test, Magnetizing current, Winding resistance, Tan delta test of Bushing & Tan delta test of Winding. SFRA Test
WIRING OF TRANSFORMER ACCESSORIES. For Proper functioning of OLTC from OLTC CR Panels, Remote operations of Radiator Fans.
OIL TESTING OF TRANSFORMER. DGA Test (Dissolved Gas Analysis). Water content Test Dielectric Strength of Oil. Specific Resistance Dielectric Dissipation factor Total Acidity check of Transformer oil Inter facial Tension. Flash point
UNLOADING OF TRANSFORMER.
DISMANTLING OF OLD 20MVA TRANSFORMER BY OIL DRAIN / RADIATOR DISMANTLING/ BUSHING DISMANTLED.
Total impact of GST for the purpose of CTC
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .