Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.8 LAccepted-AOC H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L-1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L-2₹27.2 L+₹1.5 L (5.71%)Rejected-Finance | L-2 | Rejected-Finance Higher side quoted amount | |
| 3 | L-3₹27.4 L+₹1.6 L (6.37%)Rejected-Finance BASGO LEH 194 101 U T LADAKH INDIA | LEH LADAKH | LADAKH | 194101 | L-3 | Rejected-Finance Higher side quoted amount | |
| 4 | L-4₹31.2 L+₹5.5 L (21.2%)Rejected-Finance | L-4 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹69,171
Closing Date
30 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
SPL REPAIR TO SHED NO. T-146A AND T-146B OF 184(I) FD WKPS COY, SPL REPAIR TO CH BLDG NO. T-371 OF 143 MED REGT, SPL REPAIR OF 16XFFL OF 2 NAGA, SPL REPAIR TO OR LIVING BLDG NO. T-263 OF 8(I) FD COY, AT NIMU UNDER AGE(I)NIMU
2022_MES_549287_1
80051/71/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Nimu
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
AGE(I) NIMU
₹69,171
17 Oct 2022
1 Sept 2022
1 Oct 2022
1 Sept 2022
30 Sept 2022
15 Sept 2022
Amount
Sch 'A' Part-I B/R Work:- Demolition of brick or stone/block masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles, complete all as specified and directed by Engr-in-Charge.
Demolition of stone/boulder masonery, laid dry complete all as specified and directed by Engr-in-Charge.
M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
M&L stone walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work brought to course complete all as specified and directed by Engr-in-Charge.
Rendering 15 mm thick otherthan fair face of brick work or concrete/stone surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Rendering 15 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge ..
M&L for 3 coats of white wash on new plastered surfaces of wall including preparation of surfaces all as specified and as directed.
Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
Demolition of reinforcement cement concrete of any description and in any position not otherwise specifically provided for all as directed.
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in flooring, PCC path, sub base and surface finished even and fair with out using extra cement all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in flooring, PCC path, sub base and surface finished even and fair with out using extra cement all as specified and as directed.
M&L for 40mm thick Precast cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) slab flooring, bedded, and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in flooring, PCC path, plinth protection and surface finished even and fair with out using extra cement all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in flooring and surface finished rough all as specified and as directed.
M&L for RCC nominal mix, M-20 ( using 20 mm graded crushed stone aggregate ) as in Beams, cantilevers, bressummers, lintels over 1.5m span (Note:-TMT bars will be masured and paid sepretly)
M&L for RCC nominal mix, M-15 type B-1 ( using 20 mm graded crushed stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, complete all as specified and directed by Engr-in-Charge. (Note:-TMT bars will be masured and paid sepretly)
M&L for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by the Engr-in-Charge.
M&L for Plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by the Engr-in-Charge.
M&L for Plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed by the Engr-in-Charge.
Precast reinforced cement concrete, type B-1,1:2:4 (using 20mm graded crushed stone aggreagate)as in manhole cover set in cement mortor 1:4 , complete all as specified and directed by Engr-in-Charge. (Note:-TMT bars will be masured and paid sepretly)
M & L for Cement Concrete , 1:2:4, type B1 using 20mm graded agg as in lintel upto 1.50 m span, cills, steps, seismic and other silmilar bands, plinth courses, sring courses,lacing courses, parapets and railings upt 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troghs and the like including weathering, slightly rounded or camphered angles and throating, complete all as specified and directed by Engr-in-Charge.
M & L for 100mm thick concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 110 mm bore pipe, complete all as specified and directed by Engr-in-Charge.
S&F mild steel TMT bars 10 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
S&F mild steel TMT bars 6 to 8 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves and similar work not exc.200 mm thick (horizontal or slopping) for fair finished flat surfaces all as specified and as directed.
M&L for rough finished form work to the sides of conc. Fdns, footings, bases of columns raft and raft beams, sides and soffits of fdn and plinth beams and similar work all as specified and as directed.
M&L for chequered cement concrte tile 30x30x20 mm thick with grey cement and pigment confirming jointed and pointed in neat cement slurry in floor including laid over 15mm thick screed bed of CM 1:4 complete all as specified and directed by Engr-in-Charge.
Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing serviceable like to store and rubbish off the premises, complete all as specified and directed by Engr-in-Charge
M&L Non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surface 300x 200x 7mm/ 450X 350X 7mm thick such as skirting dado, etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shed of tile including laid over 10mm thick backing layer of cement mortar (1:3)
Taking down Chowkhats or frames exc 1.5 Sqm but not exc. 4 sq. m each (without taking off shutters from the frames)
Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames)
Taking down shutters of any description exc. 1.00 sqm but not exc. 2.00sqm for refixing or removal to MES store yard all as directed.
Taking down shutters of any description exc. 2.00 sqm but not exc. 4.00sqm for refixing or removal to MES store yard all as directed.
Refixing in same opening except shutters of any discription but exc 1Sqm and n.exc 2 sqm each
M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides but with particle board core complete all as specified and as directed.
M&L for 2nd class softwood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats for doors.
M&L for 30 mm thick, factory made, glazed and skelton shutter of Second class soft wood, open rebated and prepared to received glass, gauge, etc. (without sash bars) edges of framing plain, chamfered or round, fitted without and mitred beads for securing glass, etc; sizes of members of shutters all as specified in SSR Part-I section 8 clause 8.24(b).
S&F 125mm long butt hinges, medium weight, cold rolled mild steel
S&F 100mm long butt hinges, medium weight, cold rolled mild steel
S&F 75mm long butt hinges, medium weight, cold rolled mild steel
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised
S&F 100mm long extruded aluminium alloy handles, fabricated type 'D', anodised
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section
S&F 125mm long aluminium anodised, barrel tower bolts of extruded section
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy.
S&F 300 mm ordinajry rat tail rod pattern door spring mild steel including roller and roller plate
S&F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engr-in-Charge.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe 410 W (Gde-E-250) quality A.
M&L for mild steel work (angle iron or flat iron) as in hold fasts, wall ties, clamps, ventilator pipe, rain water pipe,band, straps, hooks for hanging fans, manhole covers, MS rungs and similar small articles conforming to Fe-310-O or Fe-410-O all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, roof coverings & wall
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new surfaces of steel of any description , over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge ..
M&L for preparation of old surfaces of steel of any description , over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge ..
Excavation over area not exceeding 1.5 m depth and getting out in hard/ dense soil, complete all as specified and directed by Engr-in-Charge.
All as per item No 63 here-in-before but exceeding 1.5 m and not exceeding 3.00 m depth.
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Removal to excavated material (Soil) to a distance not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
S&F in repair PVC (SWR) vent cowl 110mm in bore complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) bends any radius of 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) junction single, (single-T), equal or unequal of 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) 'P' trap 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repair sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x420mm bowl size 410mm x 330mm x 160mm complete all as specified & directed.
Dismentling existing water tank of capacity exc.500 ltr to 1000 ltr and removal to store yard all as specified and as directed.
Dismentling existing water tank of capacity exc.250 ltr to 500 ltr and removal to store yard all as specified and as directed.
S&F 500 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 02 nos 20mm dia tank nipple and 01 Nos 32mm dia drain plug complete all as specified in SSR Part I
S&F 1000 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 02 nos 25mm dia tank nipple and 01 Nos 32mm dia drain plug complete all as specified in SSR Part I
Taking up or down water tubing & connections, including cleaning for re-fixing or removal to store of 20mm bore, complete all as specified and directed by Engr-in-Charge.
Taking up or down water tubing & connections, including cleaning for re-fixing or removal to store of 25mm bore, complete all as specified and directed by Engr-in-Charge.
S&F 20mm dia 3-layer PP-R ( Polylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., complete all as specified and directed by Engr-in-Charge.
S&F 25mm dia 3-layer PP-R ( Polylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc., complete all as specified and directed by Engr-in-Charge.
S&F in repair 20 mm bore ball brass valve, high pressure, with polythene float and fly nut complete screwed for iron pipe or for brass ferrule all as specified and directed by Engr-in-Charge.
S&F in repair Bib taps 15 mm bore,fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for brass ferrule complete all as specified and directed by Engr-in-Charge.
S & F in repairs stop valves suitable for 20 mm bore iron pipe, cast copper alloy, chromium plated, screwed down, high pressure, fancy type, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-Charge.
S & F in repair 15mm bore Angle valves, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-charge.
S&F in repair 15 mm PVC connection of 600mm long
S&F in repair PVC low level valveless, flushing cistern 10 Ltr capacity with inlet , ball valve, float valve and handle & including brackets for fixing to walls and PVC flush pipe of LDPE pipe of pressure rating 6 kg (f)/ sq.cm complete all as specified and directed by Engr-in-Charge.
S & F in repairs stainless steel squatting pan of pattern “orissa”, size 580 x 440 mm standard ivory with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in Charge.
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness including cover fillets
Dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position as in unframed work
M&L for Plain fillets of second class soft wood, sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge.
M&L for Plain fillets of second class soft wood, sectional area exc 3 Sqcm but not exc 6 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge.
S&F 9 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination and fixed with screws to timber frame work as in walls ceiling complete all as specified and directed Engr-in-Charge.
S&F 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work on ceiling complete all as specified and directed Engr-in-Charge.
Hacking out broken glass (any thickness, size or description) from wooden/metal frames, glazed with putty or fixed with beads all as specified and directed Engr-in-Charge.
S&F 4mm thick figured glass, pin head type and glazing with oil putty and wooden beads in squares n exc 0.5 sq. m in each pane
S&F 5.5mm thk sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sq.m in each pane
M&L for galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
Sch "A' Part-II E/M work:- Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc.
Taking down carefully circuit/ submain wiring for any description including DBs complete and all as specified and as directed by Engineer-in-Charge.
M&L for Sub main wiring with two single core 4 sqmm multistranded copper conductor cable, PVC insulated cable 1100 volts grade and 4 Sqmm as continous earthing drawing and including PVC casing and caping of suitable size with all acessories, complete including taking out of existing wiring all as specified.
M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover complete all as specified. (a) One light /fan/bell point/buzzer point exhaust fan controlled by one nos, one way 5/6 Amps switch.
One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size
One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size
All as per srl item No 103 here-in-before but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cable.
S&F switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type.
S&F Socket outlet multipurpose 2 in 1, 5 pin, 5 Amp flush type
S&F Switch piano, flush type single pole, one way 5 Amp
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type.
S&F Ceiling rose 65x50mm, 2 to 3 terminal PVC/polycarbonate, isolated body
S&F in repair exhaust fan made of steel body complete with frame, voltage 230V, 50 Hz, RPM 1200, of sweep 300mm complete as specified and directed.
S&F in repair LED light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up three core flexible copper conductor cable of suitable size.
S&F in repair LED lights fitting 1x 20W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F in repair sheet metal powder coated versatile double door SPN distribution board, 12 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
S&F in repair sheet metal powder coated versatile double door SPN distribution board, 8 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
S&F in repair sheet metal powder coated versatile double door SPN distribution board, 4 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz .
S&F in repair MCCB 63 Amp 4 pole with 16KA breaking capacity in distribution boards all as specified and directed.
S&F in repair MCB SPN 63 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repair MCB SPN 40 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repair MCB TP 32 Amp 415 volt 10KA 'B' curvedistribution boards all as specified and directed.
S&F in repair MCB SP 6-32 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repair 1100 volts grade heavy duty 10 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm suspension complete all as specified.
M&L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result complete including taking out of existing earthing all as specified.
Supply, laying and testing in repair LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq. mm 4 core complete all as specified
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I. (Note:-Punned thickness shall be measured and paid)
Supply and laying un reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mm x 40 mm complete all as specified.
Supply, laying and testing in repair LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 4 core complete all as specified
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, 120W LED complete all as specified and as directed by Engr-in-Charge.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 10,0074.70 and any other reduction if any from quoted amount.
CHHIRPON BUILDERS
M/S SONAM NAMGIAL
SASPOL LARJAY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .