Executive Director (Works) , ADMA
Amber Development and Management Authority Old Vidhan Sabha Bhawan, Near Hawa Mahal, Jaipur
Single water coonection and centralized RO system at Amber Fort, Jaipur. (Electrical Works)
2026_Amber_603407_8
11/2026-27
Open Tender
Electrical Works
Percentage
240 days
Amber Palace
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Chief Executive Officer, ADMA
₹97,060
7 Oct 2026
7 Oct 2026
22 Oct 2026
7 Oct 2026
21 Oct 2026
7 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect.
7.5 HP, 3-Ø, (20-35)Mtr, (1060-400) LPM ( Bronze impeller & CI Body) | 2 | Each | 49,825.5 | ₹99,651 |
| 2 | SITC of Pressure boosting pump with MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect.
1.5 HP ( 18-44 ) Mtr, (10-78 ) LPM with 35 ltr tank | 8 | Each | 44,447.06 | ₹3,55,576.48 |
| 3 | RO plant 1000 LPH (Skid mounted)
Filter Feed Pump 1 Nos. -Centrifugal Mono-block Type , MOC-Cast Iron ,Capacity 2.0 m3/hr @ 25 mwc.
Pressure Sand Filter 1 Nos.-Size- 16” x 25” vessel made by Polyglass, sand + support bed media, manual multiportvalve,Capacity 2.0 m3/hr.
Activated Carbon Filter 1 Nos.-Size- 16” x 25” vessel made by Polyglass, Activated Carbon +Support Bed media, manualmultiport valve,Capacity 2.0 m3/hr.
Antiscalant Dosing System 1 Nos.- Electro-Magnetic Type, MOC- HDPE, 2.5 kg/c m2 Operating Pressure & Capicity 0-6LPH.
Dosing Tank 1 Nos.- MOC Of Tank-HDPE & Capacity OfDosing Tanks 50 Lit.
Micron Cartridge Filter 1 Nos.-MOC of Housing-ABS & Cartridge-PP, Capacity 2.0 m3/hr, RATING 5 Micron.
High Pressure Pump 1 Nos.- Capacity 2.22 m3/hr , VerticalMultistage Type Pump , MOC- SS 304
Membranes 4 Nos.
UV System 1 Nos.- Capacity 1000LPH
Instrumentation - 1Set Of Pressure gauges, Pressure switches 2 Nos., Conductivity Meter (Inbuilt in panel)1 Nos. online Type,Level Switch 1 Lot. ,Flow Indicator 1 Lot.
Control Panel 1 Nos.
ICPW 1 Lot.-Low Pressure / High Pressure - UPVC | 6 | Set | 6,39,569.4 | ₹38,37,416.4 |
| 4 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. | - | - | - | - |
| 5 | (i) 4.0 Sq. mm 4 core | 100 | Mtr | 139.24 | ₹13,924 |
| 6 | (ii) 6.0 Sq. mm 4 core | 100 | Mtr | 172.28 | ₹17,228 |
| 7 | (iii) 10.0 Sq. mm 4 core | 100 | Mtr | 211.22 | ₹21,122 |
| 8 | (iv) 16.0 Sq. mm 4 core | 100 | Mtr | 256.06 | ₹25,606 |
| 9 | (v) 70.0 Sq. mm 3.5 core | 350 | Mtr | 685.58 | ₹2,39,953 |
| 10 | Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth. | 500 | Mtr | 125.08 | ₹62,540 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
BOQ_1069880.xls
BOQ • 0.31 MB
Item08.pdf
Tender Documents • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .