Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.2 L+₹1.8 L (5.54%)Rejected-AOC DINJAN DIST TINSUKIA ASSAM 786 189 E 67 CWE DINJAN | TINSUKIA | ASSAM | 786189 | L2 | Rejected-AOC L2 | |
| 3 | L3₹35.9 L+₹3.5 L (10.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹36.3 L+₹3.9 L (12.0%)Rejected-AOC KAJANIBARI ROAD PO DINJAN DIST TINSUKIA ASSAM 786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L4 | Rejected-AOC L4 | |
| 5 | Rejected-Technical KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | - | Rejected-Technical Not approved for opening of Cover-2 as the firm is one class below the eligible class as per NIT and having balance work in hand more than five times his tendering limit. Hence not eligible as per Note 1 of Appx A to NIT. |
| Sl No | Description | Qty | Unit | M/s GANDHESWAR PHUKAN L3 | ER. GEYUM PADU L1 | PATKAI ENTERPRISE L2 | M/S BISWAJIT SINGH L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.complete all as specified and directed. | 329.4 | Sqm | 55 ₹18,117 | 72.89 ₹24,009.97 | 52 ₹17,128.8 Lowest | 60 ₹19,764 |
| 2.00 | M&L hardcore of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 45.06 | Cum | 3,750 ₹1,68,975 | 2,842.77 ₹1,28,095.22 Lowest | 3,600 ₹1,62,216 | 3,700 ₹1,66,722 |
| 3.00 | M & L 100mm thick PCC 1:4:8 Type D-2 ( using 40mm graded stone aggregate) as in sub base complete all as specified and directed. | 300.4 | Sqm | 750 ₹2,25,300 | 731.7 ₹2,19,802.68 | 720 ₹2,16,288 Lowest | 750 ₹2,25,300 |
| 4.00 | M&L for 100mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in hard standing,and finishing the surface even and smooth without using extra cement complete all as specified and directed. | 300.4 | Sqm | 950 ₹2,85,380 | 942.42 ₹2,83,102.97 | 910 ₹2,73,364 Lowest | 950 ₹2,85,380 |
| 5.00 | M&L forming 12mm thick expansion joints filled with pre-formed bitumineous filler and top 30mm primed and sealed with sealing compound Grade 'A' complete all as specified | 24.8 | Per 10 Rm | 650 ₹16,120 | 793.89 ₹19,688.47 | 60 ₹1,488 Lowest | 75 ₹1,860 |
| 6.00 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified & as directed. | 57 | Each | 350 ₹19,950 | 355.69 ₹20,274.33 | 120 ₹6,840 Lowest | 150 ₹8,550 |
| 7.00 | M & L PCC 1:3:6 Type C-2 ( using 40mm graded stone aggregate) including pilasters,buttresses columns,pillars,boundary pillars and posts bases complete all as specified and directed. | 6.9 | Cum | 7,500 ₹51,750 Lowest | 9,024.15 ₹62,266.64 | 8,250 ₹56,925 | 8,350 ₹57,615 |
| 8.00 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long of 16 to 20mm dia of shank complete all as specified & as directed. | 47 | Kg | 180 ₹8,460 | 122.45 ₹5,755.15 Lowest | 190 ₹8,930 | 215 ₹10,105 |
| 9.00 | S&F mild steel plates ( plain or chequrred) channels, square cut or notched ( ordinary or counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W(Gde-E-250) quality-A complete all as specified & as directed. | 150.05 | Kg | 180 ₹27,009 | 128.53 ₹19,285.93 Lowest | 180 ₹27,009 | 195 ₹29,259.75 |
| 10.00 | S&F structural steel work conforming to Fe-410-W(Gde-E-250) quality-'B' rolled mild steel joist, channel, angle or tee sections,as in vertical post fixed fixed independently , without connecting platesetc. ( cut to ordinary lengths i.e within 20mm of the length indicated) complete all as specified & as directed. | 3,036 | Kg | 180 ₹5,46,480 | 113.76 ₹3,45,375.36 Lowest | 172 ₹5,22,192 | 189 ₹5,73,804 |
Tender Value
₹32.0 L
EMD Value
₹64,100
Closing Date
23 Sept 2025, 6:00 pmClosed
CWE LIKABALI
HQ CWE Likabali, Military Engineer Services, Pin-901266, C/o-99 APO
PROVN OF PARKING SHED WITH HARDSTANDING AT ALONG MIL STN
2025_MES_727972_1
83030/E8
Open Tender
Civil Works
Item Rate
180 days
ALONG
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE 872 EWS
₹64,100
Yes
10 Dec 2025
26 Aug 2025
25 Sept 2025
26 Aug 2025
23 Sept 2025
9 Sept 2025
Amount
M&L surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.complete all as specified and directed.
M&L hardcore of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L 100mm thick PCC 1:4:8 Type D-2 ( using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 100mm thick PCC type B-1, 1:2:4 (20mm graded stone aggregate) as in hard standing,and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L forming 12mm thick expansion joints filled with pre-formed bitumineous filler and top 30mm primed and sealed with sealing compound Grade 'A' complete all as specified
Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified & as directed.
M & L PCC 1:3:6 Type C-2 ( using 40mm graded stone aggregate) including pilasters,buttresses columns,pillars,boundary pillars and posts bases complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long of 16 to 20mm dia of shank complete all as specified & as directed.
S&F mild steel plates ( plain or chequrred) channels, square cut or notched ( ordinary or counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W(Gde-E-250) quality-A complete all as specified & as directed.
S&F structural steel work conforming to Fe-410-W(Gde-E-250) quality-'B' rolled mild steel joist, channel, angle or tee sections,as in vertical post fixed fixed independently , without connecting platesetc. ( cut to ordinary lengths i.e within 20mm of the length indicated) complete all as specified & as directed.
S&F mild steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe-290 (Gde-E-165) complete all as specified & as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of approved colour as directed having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L preparation of new or previously untreated surface of steel and iron work of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide zinc crome primer complete all as specified & as directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm.complete all as specified and directed.
Removal of excavated soil not exceeding. 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning to underground cable in trenches with clean dry sand for protection of underground cable complete all as specified and directed.
Supply and laying of XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 10 Sqmm x 4 core complete all as specified and directed .
Supply, install, commission and testing LT panel board of suitable size,outdoor type, manufactured by a CPRI approved factory, , weather proof, front operated door with necessary locking arrangement made of 16 SWG CRCA sheet including grouting and PCC 1:2:4 Type B-1 as per required at site complete all as specified and directed with the following accessories :- (a) MCB TPN 63 Amps, 4 pole,16 KA,415 Volts -01 Nos (b) 4 strip 45 cm long Copper bus bar of rating 100 Amps -01 Set (c) MCB SPN 32Amps, 230 Volts -04 Nos
S&F 45W LED street light fittings new generation energy saving and environment friendly long life versatile pressure die cast aluminium luminaire IP 66 protection and impact resistance IK 07 with highpower LEDs as light source inclusive of all accessories including necessary electrical connection complete all as specified and as directed.
S&F bracket for street light fitting made out of 40 mm dia light grade mild steel galvanised tube bent to required shape 1.2mts long including necessary GI clamps, nuts, bolts and washers fixed to pole complete all as specified & as directed.
S&F Factory made board distribution in sheet steel enclosure phosphotised power painted double door with 200 Amps rated bus bar, SPN, 4 ways, 240 Volts suitable for housing MCBs.complete all as specified and as directed.
S&F MCB, SPN, 240 Volts, 40 Amps 10 KA 'C' series complete all as specified and as directed .
S&F MCB, SP, 240 Volts, 6-32 Amps 10 KA complete all as specified and as directed .
M&L PVC insulated FRLS copper conductor 3 core multistrand cable of size 1 Sqmm fixing from fitting to junction box complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armouredwith galvanised steel wire or tape and overall PVC sheathed 10 Sq mm,2 core Stranded conductor nominal cross section in service connections complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanised iron wire 4 mm dia up to DB/main switch as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 15mm dia light grade GI tubing, funnel, wire mesh, 20mm bore GI tubing medium grade watering pipe , including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle of suitable size, charcoal and salt in alternate layers, necessary excavation and earth work in soft/loose soil all as shown in Electric plate No. 3 of SSR part-I and testing complete all as specified and directed
PATKAI ENTERPRISE (BID ID -3425723)
M/s GANDHESWAR PHUKAN (BID ID -3426851)
M/S BISWAJIT SINGH (BID ID -3427003)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .