Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC 25 INDUSTRIAL AREA PHASE II NAGROTA BAGWAN DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 175013 | ₹2.6 Cr | L1 | Accepted-AOC AOC after negotiation |
| 2 | L2₹2.8 Cr+₹19.2 L (7.34%)Rejected-Finance MAIN BAZAAR KANGRA | KANGRA | HIMACHAL PRADESH | ₹2.8 Cr+₹19.2 L (7.34%) | L2 | Rejected-Finance rejected Due to L2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per clause No. 1.02.1 to 1.02.4 and 1.02.6.1 and 1.02.6.2 of SBD. |
| 4 | Rejected-Technical N A | NA | NA | 121004 | - | - | Rejected-Technical as per clause No. 1.02.1, 1.02.5 and 1.02.6 of SBD |
Tender Value
₹3.1 Cr
EMD Value
₹3.1 L
Closing Date
23 Nov 2021, 1:00 pmClosed
Chief Engineer Op North HPSEBL Dharamshala
Chief Engineer Op North HPSEBL Dharamshala
Construction 33/11 kV, 1x3.15 MVA Sub- Station Sohari under ED, HPSEBL, Amb
2021_HPSEB_53360_2
CEON-SI-08/2021-22
Open Tender
Electrical Works
Turn-key
365 days
Sohari
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,360
₹3.1 L
16 Jun 2022
11 Nov 2021
24 Nov 2021
11 Nov 2021
23 Nov 2021
11 Nov 2021
Amount
Sub-Station Transformer
3.15 MVA ,33/11 KV Transformer , ONAN, OLTC, Outdoor To be provided by HPSEBL
100 KVA, 33/0.4 kV Sub-Station Transformer To be provided by HPSEBL
33 KVA Switchgear Equipment
33kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) To be provided by HPSEBL
33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850 To be provided by HPSEBL
33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850] To be provided by HPSEBL
33 kV Potential Transformer (33kV/110V, 1 Phase Multicore, Outdoor) 1No. Per Phase
33kV Current Transformer (33kV , 1 Phase Multicore Outdoor)(1 No. Per Phase)
33kV Isolator (1250A, 25kA With Earth Switch) With Structure
33kV Isolator (1250A, 25kA Without Earth Switch) With Structure
33 KV lightening arresters ( 30kv, 10kA, station class ZNO Porcelain.
33 kv drop out Fuse unit (33kv Expulsion )
11 kV Switchgear and Allied equipment: 01 No. incomer Bus
11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3Φ, Indoor)
11 kV LA/ Surge Arrester (9 KV, Station Class, ZnO, Porcelain, Outdoor)
11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured) {Transformer to 11 kV Bus} {50m+ Spare- 50m}
11 kV Cable Termination Kit (400 mm², Outdoor)
11 kV Cable Termination Kit (400 mm², Indoor)
11 kV Switchgear and Allied equipment: Single (4 No.) Outgoing Feeders
11 kV Outgoing Feeder: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) including CT
11 kV Isolator (12 kV, 630 A, 25 kA, without Earth Switch, Outdoor)
11 kV LA/ Surge Arrester (9 kV, Station Class, ZnO, Porcelain, Outdoor)
11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured) {Busbar VCB to Isolator} {50m+ Spare- 50m}
11 kV Cable Termination Kit (185 mm², Outdoor)
11 kV Cable Termination Kit (185 mm², Indoor)
LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
Capacitor Bank (3-Ф, 50 Hz, 1200 KVAr) [ IS:2834 ]
Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
Battery Bank with Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 100 AH)
Distribution Panel (30V, DC)
Distribution Panel (415 V, AC)
33kv Super structure
i) R.S. Joists, size 12800x250x125 mm 15 supports i.e. (15x12.8x37.3) i/c foundation of RS Joist
(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer's LA, Station Transformer LA, I/C, Power Transformer's CTs (10x4.2)m =42m
iii) Foundation of R.S. Joist supports
Excavation in Foundation trenches etc in earth work Pick work. Pick/Jumper work 50%
P/L C.C 1:3:6 (1 cement : 3 sand :6 agraded stone agg. 40mm nominal size) in foundation and plinth.
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying reinforced cement concrete 1:1.5:3 (1 cement : 1.5 sand :3 graded stone agg. 20mm nominal size.
P/L Tor Steel/Mild steel reinforcement for RCC work the cutting bending, binding and placing complete. Qty same as Item no.3
Steel work welded in built up section /framed work, including cutting, hosting, fixing in position and applying a primingb coat of approved steel primer using structural steel etc.as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Rs joist (250x125)[email protected]/mtr
(iv) Foundation of CT, PT & LA
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form
Foundations, footings, bases of columns, etc. for mass concrete
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA's transformer etc. (a) 22.25 Mtr long =8 No. (b) 7.125 Mtr long =20 No. ( c) 4.50 Mtr long= 8 No (d) 0.750 Mtr long =40 No. Total = 22.25x8+7.125x20+4.50x8+0.75x40= 386.50 m i.e. 387 Mtr
M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer
Nuts & Bolts with Washers off sizes
33 kV Bus Bar
3 Disc insulators Tension String complete with fitting
ACSR conductor 200 mm² at 10 % wastage 8x4.5+1x3.5)x3x1.1=130.35 say 130 m For jumpers at 2 m average 25 sets I.e. 2x3x25x1.1=165 m Total 130+165=295 m 25 sets I.e. 2x3x25x1.1=165 m
Tee connections
PG clamps
Shingles for S/Stn Yard
11kv Outdoor Gantry for outgoing feeder
Steel tubular pole 11 m long for 1 No. out going Feede
RCC muffs & concreting thereof for 1 No. out going Feeder
4.2 m long M.S. channel iron 100X50X6 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (11Kv)
5.5 m long M.S. channel iron 100X50X6 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (33kV)
M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub?Station With 1 No. out going Feede
M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub?Station With 1 No. out going Feeder [ 5.5x3+5.33x2] (33kV)
M.S. Half clamps
Full Clamp
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Discs insulator sets (comprising 3 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Clamps for 1 Nos. out going Feeder
11 kV Isolator
Earthing of 33kv Sub-Station Equipment
Cost of Material for Earth Mat laying
M.S. flat 50x6 mm for ground mat including 5% wastage & weighing 2.4 kg/m (31x15+9x5)x1.05=535.5 m or 1285.2 kg say 1.285 MT
Earthing pipe electrode
20 mm round, 3 Mtr Long & weighing 2.47 kg/m 10 No. Electrode 10x3x2.47 =74.1 kg, say 74 kg
Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:-(a) Transformer Earthing at 3 points (body & neutral) at 10 Mtr each (b) For 2 No. LA's at 4.2 Mtr each 4.2x2x1.05=8.82 Mtr(c) For 15 nos. 33 kV super structure at 11.50 Mtr each (d) For 12 Nos. VCB & CT body earthing at 10 m Each (12x10)x1.05 Total (a+b+c+d) =339.57 m i.e. 340 Mtr, 816 kg =0.816 MT = 126 Mtr 15x11.50x1.05 =173.25 Mtr i.e. 173 Mtr (3x10)x1.05=31.5 Mtr
GI wire no. 6 SWG for screening etc
Eye block for screening
Turnbuckle for Screening
Yard Fencing Including gate
MS AI 65x65x6 mm long supports 0.6 m bent outward at top & tocontain 3 strands of barbed wire 0.4 m sagged and concreted in ground and 2 m vertical supports required at every 2 m for 132 m periphery for gauge fencing of switchyard 66 Nos.
Expended metal i/c 3% wastage (1.03xL-132xH-2)=271.92 say 272 m3
GI wire 6 SWG strand all along the periphery to hold the metal 3% wastage i.e. 1.03x132x6=815.76m @ 0.150 kg/m say 122 kg
Angle iron stay with eye hook etc. for 20% of supports
Cement etc. for concreting of supports & angle iron stays
Barbed wire 3 strands of 132 m at 3% wastage 1.03x3x132 = 407.88 m = 81.576 kg Say 82 kg
Gate cost of masnory
MS AI 65x65x6 mm gates, 1.5x2.5m each gril work 2 no. i.e. 2x1.5x2.5=7.5 m2
Wicket gate
Yard lighting
9 m, Steel Tubular poles for yard lighting
18 W LED Lamp complete with fittings
Post Erection for gate
Clamps for GI pipe bracket
Underground cable 16 mm² for yard lighting
PVC cable size 6 mm² for connecting LED lamp supply
Junction box i/c MCCB and other allied
Emergency Lighting
Control and LT power cables
2x2.5 mm² control cable
4x2.5 mm² control cable
12x2.5 mm² control cable
3.5 core 95 mm² aluminium cable suitable for 415 V, AC
Telecommunication Facility
SCADA, ADSS OFC (6 Pair/12 core) including Router/ Switches etc.
Site Development
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Approach Road and Culvert
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : on W.B.M. @ 0.75 Kg / sqm
Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge. 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60- 90 TPH capacity.
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in- Charge. 25 mm compacted thickness with bitumen of grade VG- 30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100- 120 TPH capacity.
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 450 mm dia RCC pipes.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Control Room building
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiralstaircases
Edges of slabs and breaks in floors and walls Under 20 cm wide
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Providing and fixing aluminium work for doors, windows, board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge. Pre-laminated particle board with decorative lamination on both sides
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge. (Only weight of grill to be measured for payment).
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and fixing bright finished brass hard drawn hooks and eyes : 150 mm
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer.
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors herever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
(a) 15 mm nominal bore
(b) 25 mm nominal bore
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand Cast Iron S&S as per IS: 1729
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall
(i) 15 mm nominal bore
(ii) 25 mm nominal bore
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
110 mm diameter
75 mm diameter
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm nominal bore
Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000 liters net capacity tank
EI of Control Room building
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. 209 Group C.
213 Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. 217 2x2.5 Sq. mm.
214 Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- 602 25 mm. dia
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
216 2x1.5 Sq. mm.
217 2x2.5 Sq. mm.
218 2x4.0 Sq. mm.
219 2x6.0 Sq. mm.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-
806 2 modules (78mmx78mmx50mm)
807 4 modules(140mmx78mmx50mm)
808 6 modules(205mmx78mmx50mm)
809 8 modules (120mmx135mmx60mm)
810 12 modules (205mmx135mmx60mm)
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
909 S.P. 5/ 6 Amps one way Modular switch.
911 Bell push, Modular.
912 S.P. 15/ 16 Amps one way Modular switch.
914 6 pin,15/16 Amps Modular socket outlet.
913 5 pin, 5/ 6 Amps Modular socket outlet.
929 Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
936 Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
933 Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
2613 Providing and fixing following surface mounting T5 luminaries with powder coated CRCA sheet steel housing, mirror optics reflector, electronic ballast, decorative end caps, suitable for 28 watt FTL (T5), complete with all accessories (excluding the T-5 Tube), connections, testing and commissioning etc. as required. 2 x28 watt-FTL(T5) (Category-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- 2502 Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- 2505 Exhaust Fan, Heavy duty, 300 mm sweep
2711 Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. Bulk head fitting, CFL type (Category-A)
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset,neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including Earthing etc. as required:- 1809 Double door-12 way
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- 1701 Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1718 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1730 63 Amps. Cat-A.
1901 Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.( but without charcoal or coke and salt ) complete as required.
1902 Extra for using salt and charcoal for pipe earth electrode complete as required.
1909 Supplying and laying 6 SWG G.I. wire at 0.50 mtr. Below ground level for earth electrode conductor, including soldering etc. as required.
Cost of Miscellaneous Items (Protectiev Gear, T&P, Safety Provisions, Safety Equip, Furniture Items, Fire Fighting Equipments)
Meggar 2500 V- 2 Nos,1000 V
240 × 180,Advanced Thermal Imaging Camera .measures up to 650°C (1200°F), Overview AlarmMoisture, insulation, and measurement Color alarm (isotherm)Above, below, interval, condensation, insulation Detector TypeUncooled microbolometer, 17µm IR Resolution240 × 180 (43,200 pixels) Laser PointerYes; dedicated button Spectral Range7.5 – 14.0 µm Compass GPSYes
HP All in One HP200 Pro G4 , Intel core i5,21.5 " Screen or equivalent for recording the MRI Base Software for Energy Accounting at SubDivision
Godrej Almirah- 6 feet high
Staff Kit Box (Locker)
Executive Table
Executive Chair
Armed Chairs
ABC Type (portable, Dry Chemical, 9kg)
ABC Type (portable, Dry Chemical, 25kg
Mechanical Foam Type with trolley (50 ltr)
Fire Buckets with Stand (4 No.)
Tongue Tester
Earth Discharge Rods
S.S. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
PDF • 0.22 MB
tech_eval.pdf
PDF • 0.62 MB
fin_bid_open.pdf
PDF • 0.69 MB
boq_comp_chart.xlsx
xlsx • 0.03 MB
fin_eval.pdf
PDF • 0.38 MB
aoc.pdf
PDF • 2.17 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .