Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical Rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹9.0 L
EMD Value
₹17,960
Closing Date
4 Mar 2026, 10:00 amClosed
Executive Engineer
Office of the Executive Engineer CD, APWD, Campbell Bay.
Repair and maintenance of Port Control Tower, Campbell Bay under CD, APWD, Campbell Bay. Sub Work Providing IEI along with SITC of 01 No. 02 Ton Inverter split type air conditioner unit at PCT, Campbell Bay.
2026_APWD_22124_1
NIT No. 69/EE/CD/CB/2025-26
Open Tender
Electrical Works
Percentage
60 days
Executive Engineer CD, APWD, Campbell Bay
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹17,960
23 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
4 Mar 2026
25 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
a) 5/6 A switch
b) 3 pin 5/6 A socket outlet
c) 15/16 A switch
d) 6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
b) 6 Module (200 mm x 75 mm)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a)Single pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete, connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ DWC pipe as required.
Upto 35 sq. mm
Supplying of AC Ceiling Fan (1200 mm) Sweep with Socket Type Electronic regulator i/c wiring down rod of standard length (upto 30 cm) with all accessories etc., as required. Similar to make Crompton Empower 50 - 1 Star (ISI Marked) or its equivalent etc., as required as directed by Engineer-in-charge
Supplying of prewired LED tube lamp 20 W Essential Bright Batten Similar to make Philips Cat :BN170C LED20S-6500 SU L120 or Similar in make :Havels,Syska ,Bajaj,Crompton. etc as required and directed in Engineer-in-charge
Supplying, Installation, Testing and Commissioning of LED Bulkhead fitting 10W Similar to Havells HEXA 10 W Cat No. HEXAFT10WLED857SSYMBOPC or similar in bajaj, philips, crompton etc as suitable for indoor and outdoor applications as required and directed by Engineer-in-charge
Supplying and Fixing of LED Lamp 10W B22 of Make:Havells LED Adore10W or similar etc., as required for Batten Holder as directed by Engineer-in-charge
Supplying and Fixing of exhaust fan 200 mm sweep Light Duty Make:- Havells Smart Ventilair White Colour or similar etc complete with all accessories etc. asdirected by Engineer-in-charge
Supplying and fixing of LED Mirror light fitting or LED Batten as required Similar to make Bajaj Cat :BCLSB 05 WH complete etc. as required. Similar in make: Philips,Havels,Syska. ,Crompton
Supplying of following sizes of XLPE/PVC insulated armoured Aluminium conductor cable of 1.1 KV grade conforming to IS: 7098 (Part-I) and IS No. 1554 (Part-I) 1988 as applicable Make: CCI/ Gloster/ Havells/ Polycab/ Finolex as required as directed by Engineer-in-charge
a) 16sqmm x 4 core ( Panel to TPN DB)
Inter connection with PVC copper cable of suitable size etc. as required.-01 Job
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in wall/ceiling clamping or in ground (75 cm below ground level) including excavation and refilling the trench if required but excluding sand cushioning and protective covering etc., complete as required.
a) 50 mm dia (OD-50 mm & ID-38 mm nominal)
SITC of 2 Ton 5 Star as per latest rating of BEE High Wall Mounted Inverter Split Type Air Conditioner unit complete with indoor unit (IDU), outdoor unit (ODU) single phase 230V ± 10% with R32/R410A refrigerant, copper condenser coil and Rotary compressor i/c providing required length of refrigerant copper pipe of std. size as per recommendation of manufacturer of Air Conditioner with insulation, cordless remote control, cutting and drilling holes on the wall with smooth finish etc as required Similar to make Hitachi Model No.2.0TR CLASS HITACHI YOSHI 5400FXL FROST WASH INVERTER - R32 - RAS G522PCAISF - 5 STAR or its equivalent as per the direction of Engineer-In-Charge.
Supplying and Fixing of 5 KVA Voltage stabilizer suitable for 2.0 Ton Air Conditioner with working Voltage of 140V to 270V, Make: PREMIER ECO 5 DB or its equivalent as required.
Providing and fixing of Pre-fabricated stand for keeping outdoor units of 1.5 Ton/ 2.0 Ton capacity Split type AC etc. as required.
Supplying and Fixing of MCB Protected Socket in Plastic enclosure for surface mounting with MCB 20 Amps Similar to Havells DBOXx Cat No. DHDTCSN0251020 or its equivalent
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
TenderDoc69.pdf
Tender Documents • 0.73 MB
BOQ_23411.xls
BOQ • 0.36 MB
Instructions-to-bidders.pdf
Additional Documents • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .