Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 CrAccepted-AOC | ₹12.4 Cr | L1 | Accepted-AOC Bidder found lowest L1 and reasonable |
| 2 | L2₹14.8 CrRejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹14.8 Cr | L2 | Rejected-Finance being not lowest |
| 3 | L3₹17.0 CrRejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹17.0 Cr | L3 | Rejected-Finance being not lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not accepted since not fullfill the eligibility criteria given in NIT |
Tender Value
₹13.6 Cr
EMD Value
₹10.0 L
Closing Date
30 Jun 2025, 6:00 pmClosed
CE AF Udhampur Zone
HQ CE AF Udhampur Zone
COMPLETION OF INCOMPLETE WORK OF PROVN OF DEFICIENT OFFICERS AND NCsE LIVING ACCN AT AF STN LEH
2025_MES_707509_1
CEAFU- Token-03
Open Tender
Civil Works
600 days
GE P AF Leh
As per tender documents
9 documents required · 9 mandatory
₹3,000
GE P AF Leh
₹10.0 L
Yes
Udhampur
28 Jul 2025
9 May 2025
7 Jul 2025
9 May 2025
30 Jun 2025
13 Jun 2025
10 May 2025 - 16 May 2025
16 May 2025
Amount
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II (Section-I) (Plumbing works)
Total amount of Sch 'A' PART-III ( Internal water supply works)
Total amount of Sch 'A' PART-IV (Section-I) (Internal Electrification)
Total amount of Sch 'A' PART-IV (Section-II) (Internal Electrification) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs 1.00" under Col 5 signifies this fact only.
LED Street light/building light of 20 watt LED ,IP66 powder coated pressure die cast aluminium compacted high power LED street light with heat resistant toughened glass with all accessories complete including street light bracket made out of 40mm dia GI pipe light grade 1.2m long ,bent to shape,with all necessary fittings i.e nuts,bolts &clamp made out of flat iron 50x6mm-2 no.s complete all as specified and directed by Engr-in-Charge. (Note:- Contractor must firstly utilised above said material issued under Sch 'B')
LED integrated batten T5 of 18/20 Watt, 4 FT, white, indoor decorative PVC extruded T5 LED batten integrated type complete all as specified and directed by Engineer-in-Charge. (Note:- Contractor must firstly utilised above said material issued under Sch 'B')
Surface mounted LED luminare for mirror lighting 10 watt complete with lamp including connecting electrically to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.50 sqmm all as required for completion with all accessories all as specified and directed by Engr-in-Charge
Lamp holder insulated body with back plate ISI marked for batten fitting including LED 9 /10watt complete all as specified .
Bulkhead luminare LED type surface mounted comprising of high brightness LEDs of 10Watt complete all as specified.(Note:- Contractor must firstly utilised above said material issued under Sch 'B')
Distribution board vertical TPN-DPX 100 ER MCCB DBs iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB TP as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size of copper bus bar and netural link complete with one MCCB 4 pole 415 volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including fixing DB ISI Marked complete all as specified and directed by Engineer-in-Charge.
MCB single pole & neutral 240 volts 6 to 32 amps, with rupturing capacity 10KA , ISI Marked complete all as specified and directed by Engr-in-Charge.
MCB single pole 240 volts 6 to 32 amps, with rupturing capacity 10KA ,ISI Marked complete all as specified and directed by Engr-in-Charge.
Heavy duty exhaust fan copper wound single phase(as per BEE recommendation) 380mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as specified and directed by Engineer-in-Charge.
Heavy duly fexhaust fan copper wound single phase (as per BEE recommendation) 230mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as specified and directed by Engineer-in-Charge.
Total amount of Sch 'A' PART-V (Protection work)
Total amount of Sch 'A' PART-VI (Road Work)
Total amount of Sch 'A' PART-VII (Area Drainage Works)
Total amount of Sch 'A' PART-VIII (Section-I) (External Water Supply Works )
Total amount of Sch 'A' PART-VIII( Section -II) (External Water Supply Works ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs 1.00" under Col 5 signifies this fact only.
Cutting existing GI pipe of size 80mm bore and reducing to required length in position for inserting of new tee of size 80x80x50mm , complete all as specified and directed by Engineer-in-Charge. Note:-All GI fitting including GI Tee required for completion of job is deemed tobe included in the rates quoted & nothing extra shall be paid
Valve pit of size (60 x 60 x 90 cm) consisting of random rubble uncoursed stone masonary in cement mortar 1:6, 50 mm thick coping with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) incl excavation and earth work and disposal of surplus soil to a distance not exc 50 mtr and depositing where directed by Engr-in-Charge, plastering internally with 15 mm thick in cement mortar 1:6 and flush pointing externally in the same mortar as work proceed and mild steel sheet cover (3.15 mm thick) angle iron frame of 40 x 40 x 6 mm handle locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed by Engr-in-charge.
Nitrile rubber foam pipe lagging with internal dia not less than 28mm & minimum thickness 19mm alongwith Nitrile tape for insulation of GI tubing 25mm bore dia complete all as specified and directed by Engr-in-charge. (Note:- Contractor must firstly utilised above said material issued under Sch 'B') .
Total amount of Sch 'A' PART-IX ( Section-I) (Sewage Disposal supply works)
Sch 'A' PART-IX ( Section-II) (Sewage Disposal supply works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs 1.00" under Col 5 signifies this fact only.
Bio digester tank of capacity 3000 ltrs designed double walled FRP with outer wall thickness 3mm and inner wall thickness 2mm and double wall of 100mm,insulation filled between two FRP walls with liquid poly urathene foam of 150mm with 2 partition of 5mm thickness and bacteria immobization sheet and bacteria quantity of 40% of the volume of tank (tank volume 03 cubic metre) alongwith (i) Heating element (100W) -02 Nos (ii) Sensor and thermostate -01 No complete all as specified and directed by Engr-in-Charge
Bio digester tank of capacity 10000 ltrs designed double walled FRP with outer wall thickness 3mm and inner wall thickness 2mm and double wall of 100mm,insulation filled between two FRP walls with liquid poly urathene foam of 150mm with 2 partition of 5mm thickness and bacteria immobization sheet and bacteria quantity of 40% of the volume of tank (tank volume 10 cubic metre) alongwith (i) Heating element (200W) -02 Nos (ii) Sensor and thermostate -02 No complete all as specified and directed by Engr-in-Charge
Sch 'A' PART-X ,(Section-I) (Hot Water Supply Works)
Sch 'A' PART-X (Section-II) (Hot Water Supply Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs 1.00" under Col 5 signifies this fact only.
Supply, fixing, commissioning and testing of hot water generator capable of delivering a heat output 2,00,000 KCal/Hr (one working and one stand by) using HSD oil with out let temp more than 90 degree and efficiency more than 90% complete in all respect, including following item of work: (a) Heater unit: Heat exchanger, consisting of closely wound, helical, concentric coils, arranged to give adequate No of passes on flue gas and made of ERW tubes, conforming to IS 3059 Part-I, suitable for high temperature all as per manufactures design and or required head and capacity. (b) Pressure jet burner: Suitable for light oil firing with stepless modulation mechansim all as per manufactures design and of required head and capacity. (c) Combusion air fan with drive motor assembly all as per manufactures design and of required head and capacity. (d) Control Panel: Dust protected pre-wired unit mounted air cooled control panel housing a burner management system, switchgear consisting of contactor overload relays, fuses and MCBs etc, all as per manufactures design and of required capacity. (e) Circulating pumps. Centrifugal water circulating pumps suitable for high temperature operation coupled with electric motor drive, mounted on common base frame all as per manufactures design and of required head and capacity. (f) Derator cum Expansion Tank: Derator cum expansion tank consisting of expansion, derator and buffer vessels, gauge glass assembly and level switches, nozal for inlet and outlet on derator for drain on buffer vessal and for overflow, air vent and to pump on expansion vessel all as per manufactures design and of required head and capacity. (CONTD..)
(g) Piping Work: Piping work required inside the plant room including valve pressure indicating instruments, insulation material, protective works etc all as per manufactures design and of required head and capacity. (h) Fuel Pump: with drive motor assembly all as per manufactures design and of required head and capacity. (j) Oil Line: With duplex filters on fuel line at the inlet of fuel pump. Y strainer on fuel line between fuel pump and burner, non return valve on fuel pump outlet and bypass line, non return valve on modulation and circulation line, fuel oil regulation valves for burner modulation, burner solenoied valve, fuel oil pressure gauge at burner inlet, fuel pressure gauge on byepass line etc all as per manufacture design and required heat and capacity. (k) Burner programmer with matching flame sensor all as per manufacture design. (l) Hooter mounted on control panel for audible safety alarm all as per manufacture design (m) Temp indicator cum switch for high stack temp alarm for flue gases all as per manufacture design. (n) Chimney: Chimney of height as per manufacturer recommendation above building roof made out of 3mm thick as sheet including flue gas duct all as per manufacture design. (o) Design and installation of Diesel fuel storage tank of capacity 1000 ltr made out of 5mm thick MS sheet complete with supply arrangement for topping up of service tank including lifting pump set suitable, control/drain valves complete, all as specified and as directed. NOTE:- All interconnections of water lines between storage tank , boiler units, fuel lines interconnection including necessary fittings/ accessories with in plant room is deemed to be with in scope of work.
Supply, fixing, commissioning and testing of hot water generator capable of delivering a heat output 3,00,000 KCal/Hr (one working and one stand by) using HSD oil with out let temp more than 90 degree and efficiency more than 90% complete in all respect, including following item of work: (a) Heater unit: Heat exchanger, consisting of closely wound, helical, concentric coils, arranged to give adequate No of passes on flue gas and made of ERW tubes, conforming to IS 3059 Part-I, suitable for high temperature all as per manufactures design and or required head and capacity. (b) Pressure jet burner: Suitable for light oil firing with stepless modulation mechansim all as per manufactures design and of required head and capacity. (c) Combusion air fan with drive motor assembly all as per manufactures design and of required head and capacity. (d) Control Panel: Dust protected pre-wired unit mounted air cooled control panel housing a burner management system, switchgear consisting of contractor overload relays, fuses and MCBs etc, all as per manufactures design and of required capacity. (e) Circulating pumps. Centrifugal water circulating pumps suitable for high temperature operation coupled with electric motor drive, mounted on common base frame all as per manufactures design and of required head and capacity. (f) Derator cum Expansion Tank: Derator cum expansion tank consisting of expansion, derator and buffer vessels, gauge glass assembly and level switches, nozal for inlet and outlet on derator for drain on buffer vessal .(CONTD.13.04.)
and for overflow, air vent and to pump on expansion vessel all as per manufactures design and of required head and capacity. (g) Piping Work: Piping work required inside the plant room including valve pressure indicating instruments, insulation material, protective works etc all as per manufactures design and of required head and capacity (h) Fuel Pump: with drive motor assembly all as per manufactures design and of required head and capacity. (j) Oil Line: With duplex filters on fuel line at the inlet of fuel pump. Y strainer on fuel line between fuel pump and burner, non return valve on fuel pump outlet and bypass line, non return valve on modulation and circulation line, fuel oil regulation valves for burner modulation, burner solenoied valve, fuel oil pressure gauge at burner inlet, fuel pressure gauge on byepass line etc all as per manufacture design and required heat and capacity. (k) Burner programmer with matching flame sensor all as per manufacture design. (l) Hooter mounted on control panel for audible safety alarm all as per manufacture design. (m) Temp indicator cum switch for high stack temp alarm for flue gases all as per manufacture design. (n) Chimney: Chimney of height as per manufacturer recommendation above building roof made out of 3mm thick as sheet including flue gas duct all as per manufacture design. (o) Design and installation of Diesel fuel storage tank of capacity 1000 ltr made out of 5mm thick MS sheet complete with supply arrangement for topping up of service tank including lifting pump set suitable, control/drain valves complete, all as specified and as directed.NOTE:- All interconnections of water lines between storage tank , boiler units, fuel lines interconnection including necessary fittings/ accessories with in plant room is deemed to be with in scope of work.
Supply installation and testing of Hot water tank cylindrical of Cap 5000Ltrs mirror polished made out of Stain less steel of grade SS 316L/304L in 2B/BA finish with PUF insulation of 50mm thickness including stand of height as per manufacturer recommendation with 2 Nos inlet and 2 Nos outlet for cold and hot water from water installaion and boiler including piping work of suitable size for water circulation between tank and boiler, draining out and overflow with valves, insulation material and protective work complete all as per manufacturer design. Cat Pt. No. CYL/17500/SS/04-AZ of Neropure or equivalent in Nector.
Supply installation and testing of Hot water tank cylindrical of Cap 3000Ltrs mirror polished made out of Stain less steel of grade SS 316L/304L in 2B/BA finish with PUF insulation of 50mm thickness including stand of height as per manufacturer recommendation with 2 Nos inlet and 2 Nos outlet for cold and hot water from water installaion and boiler including piping work of suitable size for water circulation between tank and boiler, draining out and overflow with valves, insulation material and protective work complete all as per manufacturer design. Cat Pt. No. CYL/17300/SS/04-AZ of Neropure or equivalent in Nector.
Supply and install Pumping sets, centrifugal, electric driven capable of delivering 100LPM of water at 25m head coupled with suitable size of electric driven motor 3phase with base frame complete including suitable size DOL starter including PCC foundation as per manufacturer recommendation all as specificed and as directed by Engr in charge.
Gun-metal, globe or gate valves, 25mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete used to drain out water from 40mm bore dia pipe including all necessary GI fittings for completion of job and as directed by Engr in charge.
Valve pit of size (60x 60 x 90 cm) consisting of random rubble uncoursed stone masoinary in cement mortar 1:6 ,50 mm thick coping with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) incl excavation and earth work and disposal of surplus soil to a distance not exc 50 mtr and depositing where directed by Engr-in-Charge, plastering internally with 15 mm thick in cement mortar 1:6 and flush pointing externally in the same mortor as work proceed and mild steel sheet cover (3.15 mm thick) angle iron frame of 40 x 40 x 6 mm handle locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed by Engr-in-charge.
Insulation of GI tubing of 25mm bore dia by using nitrile rubber foam pipe lagging of 19mm thick complete all as specified and directed by Engr-in-charge.
Insulation of GI tubing of 20mm bore dia by using nitrile rubber foam pipe lagging of 19mm thick complete all as specified and directed by Engr-in-charge.
Sch 'A' PART-XI (Section-I) (Central Air Heating Works)
Sch 'A' PART-XI (Section-II) ((Central Air Heating Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs 1.00" under Col 5 signifies this fact only.
Design, Supply, fixing, commissioning and testing of vertically mounted Thermic Fluid Heater (TFH) capable of delivering a heat output 2,00,000 K Cal/Hr (one working and one stand by) using HSD oil complete in all respect, including following item of work. (For NC's (E) ) (a) Out side temp (-) 30 degree centigrade (b) Desired inside temp 22 degree centigrade (c) And also considering suitable climate conditions of leh. (i) The tenderer should work out details of heat load calculations and technical parameters based on the building plan outside/inside parameters and design parameters as given in the tender and quote accordingly. (ii) The tenderer shall be responsible for the design of plant to meet required parameters and should get design approved from IIT/NIT for conditioning round the clock. (iii) The tenderer should get the plant installed by any of the original equipment manufacturer viz Voltas/Blue star /carrier with their recommended makes of compatible components/items. (iv) In case of any change in the technical parameter considered required to provide the design conditions, the tenderer should furnish the revised technical parameters along with the tender. (a) Heater unit: heat exchanger, consisting of closely wound , helical, concentric coils, arranged to give adequate no of passes on flue gas side & made out of ERW tubes, confirming to IS 3059 Pt-I, suitable for high temperature all as per manufacturer design and of required head and capacity. (CONTD.15.02.)
(b) Pressure jet burner : suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity. (d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contactors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity. (e) Circulating Pumps : Centrifugal Thermic fluid circulating pumps suitable for heigh temp operation, coupled with electric motor drive, mounted on common base frame all as per manufacturer design and of required head and capacity. (f) DE Tank : Derator cum expansion tank consisting of expansion, derator and buffer vessels , gauge glass assembly and level switches. Nozal for inlet and outlet on derator for drain on buffer vessel and for overflow, air vent and topup on expansion vessel all as per manufacturer design and of required head and capacity. (g) Fuel pump : with drive motor assembly all as per manufacturer design and of required head and capacity. (h) Piping work : required inside the plant room, including valves, pressure indicating instruments, insulation material, protective works etc all as per manufacturer design and of required head and capacity. (j) Oil line : with duplex filters on fuel line at the inlet of fuel pump, Y strainer on fuel line between fuel pump and burner, non return valve on fuel pump outlet and (CONTD 15.03)
byepass line, non return valve on modulation and circulation line, fuel oil regulation valves for burner modulation, burner solenoid valve, fuel oil pressure gauge at burner inlet, fuel pressure gauge on by pass line etc all as per manufacturer design and of required head and capacity (k) Thermic fluied line : inside the plant room with insulating material, spring loaded safety relief valves , Temp controller for stepless burner modulation on thermic fluid outlet temp of the heater, switch for burner on off cycle, burner interlocking with temp of thermic fluid at , differential pressure switch between inlet / outlet of fluid outlet all as per manufacturer design and of required head and capacity. (l) Burner programmer with matching flame sensor all as per manufacturer design. (m) Hooter mounted on control panel for audible safety alarm all as per manufacturer design. (n) Temp indicator cum-switch for high stack temp alarm for flue gases all as per manufacturer design. (o). Chimney : 10 mtr heigh chimny above bldg roof made out of 3 mm thick MS sheet including flue gas duct all as per manufacturer design. Note :- Thermic fluid and thermic fluid line including lagging from plant room to work place shall be provided as separate item of work .
Design, Supply, fixing, commissioning and testing of vertically mounted Thermic Fluid Heater (TFH) capable of delivering a heat output 2,50,000 K Cal/Hr (two working and one stand by) using HSD oil complete in all respect, including following item of work. ( for Offrs & Servant qtrs) (a) Out side temp (-) 30 degree centigrade (b) Desired inside temp 22 degree centigrade (c) And also considering suitable climatic conditions of leh. (i) The tenderer should work out detail of heat load calculations and technical parameters based on the building plan outside/inside parameters and design parameters as given in the tender and quote accordingly. (ii) The tenderer shall be responsible for the design of plant to meet required parameters and should get design approved from IIT/NIT for conditioning round the clock. (iii) The tenderer should get the plant installed by any of the original equipment manufacturer viz Voltas/Blue star /carrier with their recommended makes of compatible components/items. (iv) In case of any change in the technical parameter considered required to provide the design conditions, the tenderer should furnish the revised technical parameters along with the tender. (a) Heater unit: heat exchanger, consisting of closely wound , helical, concentric coils, arranged to give adequate no of passes on flue gas side & made out of ERW tubes, confirming to IS 3059 Pt-I, suitable for high temperature all as per manufacturer design and of required head and capacity. (CONTD 15.05)
(b) Pressure jet burner : suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity. (d) Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contractors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity. (e) Circulating Pumps : Centrifugal Thermic fluid circulating pumps suitable for heigh temp operation, coupled with electric motor drive, mounted on common base frame all as per manufacturer design and of required head and capacity. (f) DE Tank : Derator cum expansion tank consisting of expansion, derator and buffer vessels , gauge glass assembly and level switches. Nozal for inlet and outlet on derator for drain on buffer vessel and for overflow, air vent and topup on expansion vessel all as per manufacturer design and of required head and capacity. (g) Fuel pump : with drive motor assembly all as per manufacturer design and of required head and capacity. (h) Piping work : required inside the plant room, including valves, pressure indicating instruments, insulation material, protective works etc all as per manufacturer design and of required head and capacity. (j) Oil line : with duplex filters on fuel line at the inlet of fuel pump, Y strainer on fuel line between fuel pump and burner, non return valve on fuel pump outlet and byepass line, non return valve on modulation and circulation line, fuel oil regulation valves for (CONTD..)
burner modulation, burner solenoid valve, fuel oil pressure gauge at burner inlet, fuel pressure gauge on by pass line etc all as per manufacturer design and of required head and capacity. (k) Thermic fluid line : inside the plant room with insulating material, spring loaded safety relief valves , Temp controller for stepless burner modulation on thermic fluid outlet temp of the heater, switch for burner on off cycle, burner interlocking with temp of thermic fluid at , differential pressur switch between inlet / outlet of fluid outlet all as per manufacturer design and of required head and capacity. (l) Burner programmer with matching flame sensor all as per manufacturer design. (m) Hooter mounted on control panel for audible safety alarm all as per manufacturer design. (n) Temp indicator cum-switch for high stack temp alarm for flue gases all as per manufacturer design. (o). Chimney : 10 mtr heigh chimny above bldg roof made out of 3 mm thick MS sheet including flue gas duct all as per manufacturer design. Note :- Thermic fluid and thermic fluid line including lagging from plant room to work place shall be provided as separate item of work.
Supply and Installation of thermic fluid storage tank of capacity of 2000 ltr made out of 5mm thick MS sheet complete all as specified and as directed.
Supply and Installation of Deisel fuel storage tank of capacity 1000 ltr made out of 5mm thick MS sheet complete all as specified and as directed.
Kaiflex insulation for insulating 100mm MS tubing of suitable inner dia and 19 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified.
Kaiflex insulation for insulating 80mm MS tubing of suitable inner dia and 19 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified.
Kaiflex insulation for insulating 50mm MS tubing of suitable inner dia and 19 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified.
Kaiflex insulation for insulating 40mm MS tubing of suitable inner dia and 19 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified.
Kaiflex insulation for insulating 25mm MS tubing of suitable inner dia and 19 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 Metres below normal ground level, connecting to the Galvanised iron earth wire 4mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanised iron protected by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.50 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil complete all as specified and directed by Engr-in-charge
Supply in barrels and filling of thermic fluid of capacity above 20°C Temp as vapourisation temprature complete all as specified and directed by Engr in charge.
Supply ,installation and erection of chimney 10mtr height as per design for 200000 kcal/hr boiler complete all as specified and directed by Engr in charge.
Supply ,installation and erection of chimney 10mtr height as per design for 2,50,000 kcal/hr boiler complete all as specified and directed by Engr in charge.
MCB SPN 240Volts 32 to 63Amps with rupturing capacity 10kA complete all as specified and directed by Engr in charge.
MCB SP 240Volts 6 to 32 Amps with rupturing capacity 10kA complete all as specified and directed by Engr in charge.
100mm bore mild steel tubing medium grade with all fittings and fixed to wall/ceiling or laid in floors & trenches , complete all as specified and directed by Engr in charge.
80mm bore mild steel tubing medium grade with all fittings and fixed to wall/ceiling or laid in floors & trenches , complete all as specified and directed by Engr in charge.
50mm bore mild steel tubing medium grade with all fittings and fixed to wall/ceiling or laid in floors & trenches , complete all as specified and directed by Engr in charge.
40mm bore mild steel tubing medium grade with all fittings and fixed to wall/ceiling or laid in floors & trenches , complete all as specified and directed by Engr in charge.
25mm bore mild steel tubing medium grade with all fittings and fixed to wall/ceiling or laid in floors & trenches , complete all as specified and directed by Engr in charge.
Total amount of Sch 'A' Part-XII (Section-I)(EXTERNAL ELECTRIFICATION)
Sch 'A' Part-XII (Section-II) (EXTERNAL ELECTRIFICATION)) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supplying, installing, connecting, testing and commissioning AC three phase four wire 50 c/s, 125 KVA capacity transformer copper wounded Step Up outdoor type 433/11000 volts (at no load), oil immersed, naturally cooled with external cooling tubes, core type delta, connected on primary (LV side) and star connected (HV side) in accordance with vector symbol (Vector group) with neutral brought on secondary (LV) side and having tappings on HV side voltage upto at (+/-) 2.5%, to (+/-) 7.5% to be changed by means of hand operated 'off load' tap changing gear the maximum temperature rise not to exceed 45 degree centrigrade in oil and 55 degree centrigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temperature of 40 degree centigrade, the transformer shall be supplied complete with standard fittings and mainly comprising of following conforming to IS-1180(Part-I):- (a) HT cable end box in lieu of HT bushing outdoor type with HT bushing of porcelain 11 KV, 3 Nos with brass nuts, bolts, and washer and cable gland of brass of 95 Sqmm 3 core cable -01 No. (b) One cable box LV side consisting of four Nos porcelain bushing with bushing rod of brass with nut, bolts and washers with 4 Nos cable gland of brass of 95 Sqmm 3.5 core cable (c) Oil conservator with filter type drain valve and oil level gauge (d)Dehydrating breather with first fill of dehydrating agent. (e) Explosive vent (f) Thermometer pocket on tank cover.. (g) One number 100mm dia dial type thermometer vapour pressure type, having range 0-120 degree Centigrade with metal guard having maximum temperature indicator with resetting device.
(h) Rating & terminal plate. (j) Four Nos earthing terminals (2Nos for body and 2Nos for Neutral) to facilitate fixing of 32x6mm earth strip. (k) Oil level gauge. (l) Oil drain valve (m) Lifting lugs. (n) Oil filter hole with cap plug and connection complete o) Air release valve plug. (p) Four plain solid cast steel detachable rollers (q) Extra bushing for neutral outside and cable box for providing independent earthing for neutral. (r) First fill of fresh oil conforming to relevent IS, tested upto 60 KV die electric strength.
Supplying, installing, connecting, testing and commissioning AC three phase four wire 50 c/s, 125 KVA capacity transformer copper wounded step down outdoor type 11000/433 volts (at no load), oil immersed, naturally cooled with external cooling tubes, core type delta, connected on primary (HV side) and star connected (LV side) in accordance with vector symbol (Vector group) with neutral brought on secondary (LV) side and having tappings on HV side voltage upto at (+/-) 2.5%, to (+/-) 7.5% to be changed by means of hand operated 'off load' tap changing gear the maximum temperature rise not to exceed 45 degree centrigrade in oil and 55 degree centrigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temperature of 40 degree centigrade, the transformer shall be supplied complete with standard fittings and mainly comprising of following conforming to IS-1180(Part-I):- (a) HT cable end box in lieu of HT bushing outdoor type with HT bushing of porcelain 11 KV, 3 Nos with brass nuts, bolts, and washer and cable gland of brass of 95 Sqmm 3 core cable -01 No. (b) One cable box LV side consisting of four Nos porcelain bushing with bushing rod of brass with nut, bolts and washers with 4 Nos cable gland of brass of 95 Sqmm 3.5 core cable (c) Oil conservator with filter type drain valve and oil level gauge (d)Dehydrating breather with first fill of dehydrating agent.(CONTD 17.04)
(e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One number 100mm dia dial type thermometer vapour pressure type, having range 0-120 degree Centigrade with metal guard having maximum temperature indicator with resetting device. (h) Rating & terminal plate. (j) Four Nos earthing terminals (2Nos for body and 2Nos for Neutral) to facilitate fixing of 32x6mm earth strip. (k) Oil level gauge. (l) Oil drain valve (m) Lifting lugs. (n) Oil filter hole with cap plug and connection complete (o) Air release valve plug. (p) Four plain solid cast steel detachable rollers (q) Extra bushing for neutral outside and cable box for providing independent earthing for neutral. (r) First fill of fresh oil conforming to relevent IS, tested upto 60 KV die electric strength.
Supplying, installing, connecting, testing and commissioning AC three phase four wire 50 c/s, 500 KVA capacity transformer copper wounded Step up outdoor type 433/11000 volts (at no load), oil immersed, naturally cooled with external cooling tubes, core type delta, connected on primary (LV side) and star connected (HV side) in accordance with vector symbol (Vector group) with neutral brought on secondary (LV) side and having tappings on HV side voltage upto at (+/-) 2.5%, to (+/-) 7.5% to be changed by means of hand operated 'off load' tap changing gear the maximum temperature rise not to exceed 45 degree centrigrade in oil and 55 degree centrigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temperature of 40 degree centigrade, the transformer shall be supplied complete with standard fittings and mainly comprising of following conforming to IS-2026-1977:- (a) HT cable end box in lieu of HT bushing outdoor type with HT bushing of porcelain 11 KV, 3 Nos with brass nuts, bolts, and washer and cable gland of brass of 95 Sqmm 3 core cable -01 No. (b) One cable box LV side consisting of four Nos porcelain bushing with bushing rod of brass with nut, bolts and washers with 4 Nos cable gland of brass of 500 Sqmm 3.5 core cable (c) Oil conservator with filter type drain valve and oil level gauge (d)Dehydrating breather with first fill of dehydrating agent. (CONTD.17.06)
(e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One number 100mm dia dial type thermometer vapour pressure type, having range 0-120 degree Centigrade with metal guard having maximum temperature indicator with resetting device. (h) Rating & terminal plate. (j) Four Nos earthing terminals (2Nos for body and 2Nos for Neutral) to facilitate fixing of 32x6mm earth strip. (k) Oil level gauge. (l) Oil drain valve (m) Lifting lugs. (n) Oil filter hole with cap plug and connection complete (o) Air release valve plug. (p) Four plain solid cast steel detachable rollers (q) Extra bushing for neutral outside and cable box for providing independent earthing for neutral. (r) First fill of fresh oil conforming to relevent IS, tested upto 60 KV die electric strength.
Supplying, installing, connecting, testing and commissioning AC three phase four wire 50 c/s, 500 KVA capacity transformer copper wounded Step down outdoor type 11000/433 volts (at no load), oil immersed, naturally cooled with external cooling tubes, core type delta, connected on primary (HV side) and star connected (LV side) in accordance with vector symbol (Vector group) with neutral brought on secondary (LV) side and having tappings on HV side voltage upto at (+/-) 2.5%, to (+/-) 7.5% to be changed by means of hand operated 'off load' tap changing gear the maximum temperature rise not to exceed 45 degree centrigrade in oil and 55 degree centrigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temperature of 40 degree centigrade, the transformer shall be supplied complete with standard fittings and mainly comprising of following conforming to IS-2026-1977:- (a) HT cable end box in lieu of HT bushing outdoor type with HT bushing of porcelain 11 KV, 3 Nos with brass nuts, bolts, and washer and cable gland of brass of 95 Sqmm 3 core cable -01 No. (b) One cable box LV side consisting of four Nos porcelain bushing with bushing rod of brass with nut, bolts and washers with 4 Nos cable gland of brass of 500 Sqmm 3.5 core cable (c) Oil conservator with filter type drain valve and oil level gauge (d)Dehydrating breather with first fill of dehydrating agent.(CONTD 17.08)
(e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One number 100mm dia dial type thermometer vapour pressure type, having range 0-120 degree Centigrade with metal guard having maximum temperature indicator with resetting device. (h) Rating & terminal plate. (j) Four Nos earthing terminals (2Nos for body and 2Nos for Neutral) to facilitate fixing of 32x6mm earth strip. (k) Oil level gauge. (l) Oil drain valve (m) Lifting lugs. (n) Oil filter hole with cap plug and connection complete (o) Air release valve plug. (p) Four plain solid cast steel detachable rollers (q) Extra bushing for neutral outside and cable box for providing independent earthing for neutral. (r)First fill of fresh oil conforming to relevent IS, tested upto 60 KV die electric strength.
Supply, Installation, commisioning and testing LT panel outdoor cubical floor mounted type of suitable size made out of 3.15 mm thick CRCA sheet duly powder coated complete, suitable to accommodate Air Circuit Breaker 4 Pole, 415 V, Electrical Drawout type with microprocessor release of capacity 630 Amps, 50kA power supply system and On load changeover open execution switch of 630Amps,4P fixed on angle iron of size 50x50x6mm panel embedded in 40mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate),and complete with overload protection, no-volt release with necessary CTs, PTs, indicators & multifunction complete all as specifed.
Distribution cum junction Box 4.5 Module of size 126 x 228 x 111, KV PC Small - type including MCB SP 6Amp with IP 65 protection with mounting mechanism and all accesseries complete all as specified and directed by Engineer-in-Charge.
Supply and fix ENDURA CITYLINER NEO PLUS 45W LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD including street light bracket made out of 40mm dia GI pipe light grade 1.2m long ,bend to shape with all necessary fitting i.e nut,bolts & clamps made out of flat iron 50x6mm-2 no.s. Cat Part No. LHETAXU7PA6W048 of Havells or equivalent in Bajaj / Phillips complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 Metres below normal ground level, connecting to the Galvanised iron strip of size (32x6) mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanised iron protected by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.50 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
All as per Srl Item No. 17.14 here-in-befor but using galvanised earth lead wire 4.0mm complete all as specified and directed by Engineer-in-Charge.
as per manufacturer rececommendation. (d) Electric Starter equipment :- the equipment will comprise the following :- (i) Maint free battery duly initialy charged of suitable capacity & battery Lead of aqequate capacity Make of Battery Exide/Amron/ (ii) Starter Motor (iii) Starter gearing (iv) Start/Stop push button (v) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz Ac supply system for charging of DG set batteries to charge the set batteries externally when DG set is in off position Make : sukam (vi) Alternator/dynamo of suitable capcity while DG set is running complete with auto cut out all as per manufacturer recommendation (e) PCC foundation for DG set of suitable size including 1 mtr working space all around the DG set and 0.2 mtr above and 0.3 mtr below FFL all as per manufacturer recommendation or as per direction by Engr-in-charge.
as per manufacturer rececommendation. (d) Electric Starter equipment :- the equipment will comprise the following (i) Maint free battery duly initialy charged of suitable capacity & battery Lead of aqequate capacity Make of Battery Exide/Amron/ (ii) Starter Motor (iii) Starter gearing (iv) Start/Stop push button (v) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz Ac supply system for charging of DG set batteriesto charge the set batteries externally when DG set is in off position Make : sukam (vi) Alternator/dynamo of suitable capcity while DG set is running complete with auto cut out all as per manufacturer recommendation (e) PCC foundation for DG set of suitable size including 1 mtr working space all around the DG set and 0.2 mtr above and 0.3 mtr below FFL all as per manufacturer recommendation or as directed byEngr-in-charge.
Total amount of Sch 'A' Part-XIII(SITE CLEARANCE,EXCAVATION AND EARTH WORK)
Total amount of Sch 'A' Part-XIV (DEMOLITION /DISMANTLING OF TEMPORARY BUILDING & E/M WORK )
Sch of credit : Amount of credit Rs 6645.80 for retrieved material mentioned in Sch A Part XV of tender document in PDF form which will be deducted offline during acceptance of tender
M/S ANIL KUMAR (BID ID -3340125)
M/S Sunil Steel Works (BID ID -3341371)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.