Loading…
Loading…
Tender Value
Refer Docs
Closing Date
16 Jul 2026, 11:30 amClosed
Single Packet
Normal Tender
No
Itemwise/Consigneewise
Lowest to Highest
TPI Agency
Not Applicable
Expenditure
General
04
1 condition
Eligibility Criteria : not applicable
14 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
TPI (Third party inspection).
Packing Instruction Applicable : STAINLESS STEEL SHEETS, COILS AND PLATES:- (A) STAINLESS STEEL (AUSTENITIC & FERRITIC STEEL) COILS. THE COIL SHALL BE PROTECTED IN REASONABLY GOOD CONDITION TO WITHSTAND NORMAL HANDLING HAZARD DURING TRANSIT WITH THE FOLLOWING PROVISION AS THE BAREST MINIMUM: I) COIL SHOULD BE WRAPPED WITH A LAYER OF WATER PROOF PAPER THROUGH OUT WHOLE LENGTH. II) COIL SHOULD BE WRAPPED WITH A LAYER OF BIODEGRADABLE SHEET. III) OUTER & INNER OF COIL SHOULD BE WRAPPED WITH GI SHEET. IV) SIDE OF THE COIL SHOULD BE COVERED WITH CARD BOARD SHEET. V) AFTER THIS WHOLE COIL SHOULD BE WRAPPED WITH BIODEGRADEABLE PLASTIC SHEET OF SUITABLE THICKNESS. VI) THE INNER EDGE OF THE COIL SHOULD BE PROTECTED BY GI RING FOLLOWED BY ANOTHER IRON RING. VII) OUTER EDGE OF THE COIL SHOULD BE WRAPPED WITH GI RING. VIII) COIL SHOULD BE SECURELY STRAPPED WITH MINIMUM 5 STEEL BANDS THROUGH THE EYES OF THE COIL AND MINIMUM 3 STEEL BANDS ON THE CIRCUMFERENCE OF THE EYE. IX) WHOLE COIL SHOULD BE MOUNTED ON WOODEN BLOCKS FOR EASY LIFTING/STACKING. X) THE SHEETS IN COIL FORM FOR THICKNESS 2MM AND ABOVE SHALL HAVE: INNER DIA OF COIL 450-800MM OUTER DIA OF COIL 1000-1300MM WEIGHT OF COIL 2.4 - 10 TONNES XI) THE SHEETS IN COIL FORM FOR THICKNESS BELOW 2MM SHALL HAVE: INNER DIA OF COIL 450-650MM OUTER DIA OF COIL 1000-1300MM WEIGHT OF COIL 5.0 - 10 TONNES. (B) STAINLESS STEEL (AUSTENITIC & FERRITIC STEEL PLATES/SHEETS) I) THE SHEETS/PLATES SHALL BE SUPPLIED IN BUNDLES OF OPTIMUM SUPPLIED IN BUNDLES OF OPTIMUM WEIGHT: 2MT+/-10% & EACH SHEET/PLATE SHALL BE SEPERATED WITH A LAYER OF WATER PROOF PAPER, AFTER THIS THE WHOLE BUNDLE SHOULD BE WRAPPED WITH DOUBLE LAYER OF WATER PROOF PAPER AND A BIODEGRADABLE PLASTIC SHEET OF SUITABLE THICKNESS. A METAL PROTECTION IN EDGES SHOULD ALSO BE PROVIDED. II) ALL BUNDLES SHALL HAVE A MINIMUM OF 2 HOOPS UPTO 1.2 METER IN LENGTH AND ONE EXTRA HOOP FOR EVERY ADDITIONAL METER. THE BUNDLES SHALL ALSO BE PROVIDED WITH SKID (WOODEN PACKING UNDER NEATH) TO FACILITATE HANDLING. MECHANICAL DAMAGE & CORROSION DURING TRANSIT IF ANY SHALL BE AT THE COST OF SUPPLIER. , Protection Procedure: COVERED IN PI
Quantity Splitting :- As per clause No.2.17.2 of Bid document Ver.14 or latest with all corri.and amdts.
1 condition
Validity of Offer: No deviation from the offer validity period stipulated in the tender is permitted.
1 location across Punjab · 7,000 Kg total
FERRITIC STEEL SHEET 10X1250X3000MM
04261033
04261033
Limited - Indigenous
Goods
Punjab
₹0
Exempted
16 Jul 2026
9 Jul 2026
1 item · 7,000 Kg total
FERRITIC STEEL SHEET 10X1250X3000MM., as per Drawing: RDSO SPEC. NO. C-K201, G RADE X2CRNI12 (409M), HEAT TREATMENT CONDITION 2D AS PER TABLE-5., Packing Instruction: STAI NLESS STEEL SHEETS, COILS AND PLATES:- (A) STAINLESS STEEL (AUSTENITIC & FERRITIC STEEL) COIL S. THE COIL SHALL BE PROTECTED IN REASONABLY GOOD CONDITION TO WITHSTAND NORMAL HAND LING HAZARD DURING TRANSIT WITH THE FOLLOWING PROVISION AS THE BAREST MINIMUM: I) COIL SHOULD BE WRAPPED WITH A LAYER OF WATER PROOF PAPER THROUGH OUT WHOLE LENGTH. II) COI L SHOULD BE WRAPPED WITH A LAYER OF BIODEGRADEABLE SHEET. III) OUTER & INNER OF COIL SHO ULD BE WRAPPED WITH GI SHEET. IV) SIDE OF THE COIL SHOULD BE COVERED WITH CARD BOARD SH EET. V) AFTER THIS WHOLE COIL SHOULD BE WRAPPED WITH BIODEGRADEABLE PLASTIC SHEET OF S UITABLE THICKNESS. VI) THE INNER EDGE OF THE COIL SHOULD BE PROTECTED BY GI RING FOLLOWE D BY ANOTHER IRON RING. VII) OUTER EDGE OF THE COIL SHOULD BE WRAPPED WITH GI RING. VIII) C OIL SHOULD BE SECURELY STRAPPED WITH MINIUM 5 STEEL BANDS THROUGH THE EYES OF THE COIL AND MINIUM 3 STEEL BANDS ON THE CIRCUMFERENCE OF THE EYE. IX) WHOLE COIL SHOULD BE MOU NTED ON WOODEN BLOCKS FOR EASY LIFTING/STACKING. X) THE SHEETS IN COIL FORM FOR THICKNE SS 2MM AND ABOVE SHALL HAVE: INNER DIA OF COIL 450-800MM OUTER DIA OF COIL 1000-1300MM WEIGHT OF COIL 2.4 - 10 TONNES XI) THE SHEETS IN COIL FORM FOR THICKNESS BELOW 2MM SHALL HAVE: INNER DIA OF COIL 450-650MM OUTER DIA OF COIL 1000-1300MM WEIGHT OF COIL 5.0 - 10 TO NNES. (B) STAINLESS STEEL (AUSTENITIC & FERRITIC STEEL PLATES/SHEETS) I) THE SHEETS/PLATES S HALL BE SUPPLIED IN BUNDLES OF OPTIMUM WEIGHT: 2MT+/-10% & EACH SHEET/PLATE SHALL BE SE PRATED WITH A LAYER OF WATER PROOF PAPER, AFTER THIS THE WHOLE BUNDLE SHOULD BE WRAPP ED WITH DOUBLE LAYER OF WATER PROOF PAPER AND A BIODEGRADEABLE PLASTIC SHEET OF SUITA BLE THICKNESS. A METAL PROTECTION IN EDGES SHOULD ALSO BE PROVIDED. II) ALL BUNDLES SHAL L HAVE A MINIMUM OF 2 HOOPS UPTO 1.2 METER IN LENGTH AND ONE EXTRA HOOP FOR EVERY ADDI TIONAL METER. THE BUNDLES SHALL ALSO BE PROVIDED WITH SKID (WOODEN PACKING UNDER NEAT H) TO FACILITATE HANDLING. MECHANICAL DAMANGE & CORROSION DURING TRANSIT IF ANY SHALL B E AT THE COST OF SUPPLIER. [ Warranty Period: 30 Months after the date of delivery ] [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitt ed: Max 8 lacs ] ]
| Delivery Location | State | Quantity |
|---|---|---|
| SHELL DEPOT, RCF | Punjab | 7000.00 Kg |
| Total | 7,000 Kg | |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .