| Sl No | Description | Qty | Unit | Agarwal Jagdish Construction Company Private Limited L4 | D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED L3 | V M MATERE INFRASTRUCTURES INDIA PVT LTD L1 | MAA BHAGWATI ASSOCIATES L8 | surendra infrastructure pvt ltd L7 | NARSINGH DEVELOPERS LLP L6 | SHREE VENKATESHA CONSTRUCTION COMPANY L2 | CMRGS Infrastructure Projects Ltd L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE "A" Part-I (Building/Structures) (To be quoted by the tenderer) | |||||||||||
| 2.00 | Item No 01 : Design and construction of Single Men Barracks incl Cook House and Dining hall For Agniveers. Complete all specified in soil bearing capacity report, design basis report drawings and tender documents. | 2 | Each Block | 11,55,00,000 ₹23.1 Cr | 10,86,90,867 ₹21.7 Cr | 9,61,53,600 ₹19.2 Cr | 10,11,00,000 ₹20.2 Cr | 10,70,40,000 ₹21.4 Cr | 12,00,00,000 ₹24 Cr | 10,39,00,000 ₹20.8 Cr | 12,65,00,000 ₹25.3 Cr |
| 3.00 | Sch 'A' Part-II (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. | 1 | Lump sum | 1,09,59,927.81 ₹1.1 Cr | 1,37,95,725 ₹1.4 Cr | 65,28,000 ₹65.3 L | 1,23,20,000 ₹1.2 Cr | 1,78,62,400 ₹1.8 Cr | 1,44,70,200 ₹1.4 Cr | 80,00,000 ₹80 L | 1,13,00,000 ₹1.1 Cr |
| 4.00 | Sch 'A' Part-III (External Water Supply) Lump sum price worked out by the contractor for (External Water Supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. | 1 | Lump sum | 5,16,023.97 ₹5.2 L | 6,29,395 ₹6.3 L | 3,07,200 ₹3.1 L | 5,95,000 ₹6.0 L | 5,50,000 ₹5.5 L | 5,00,000 ₹5 L | 4,00,000 ₹4 L | 4,25,000 ₹4.3 L |
| 5.00 | Sch 'A' Part-IV (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. | 1 | Lump sum | 1,12,63,364.92 ₹1.1 Cr | 1,13,51,155 ₹1.1 Cr | 73,34,400 ₹73.3 L | 1,48,30,000 ₹1.5 Cr | 1,15,00,000 ₹1.1 Cr | 1,31,09,392.86 ₹1.3 Cr | 93,00,000 ₹93 L | 1,05,00,000 ₹1.1 Cr |
| 6.00 | Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. | 1 | Lump sum | 29,15,928.18 ₹29.2 L | 22,83,665 ₹22.8 L | 16,89,600 ₹16.9 L | 53,50,000 ₹53.5 L | 52,00,000 ₹52 L | 25,62,530.74 ₹25.6 L | 21,00,000 ₹21 L | 25,00,000 ₹25 L |
| 7.00 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. | 1 | Lump sum | 25,31,572.8 ₹25.3 L | 16,76,560 ₹16.8 L | 13,82,400 ₹13.8 L | 53,00,000 ₹53 L | 70,58,000 ₹70.6 L | 29,23,966.1 ₹29.2 L | 17,00,000 ₹17 L | 17,95,000 ₹17.9 L |
| 8.00 | Sch 'A' Part-VII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES. | 1 | Lump sum | 20,59,051.8 ₹20.6 L | 8,33,720 ₹8.3 L | 13,44,000 ₹13.4 L | 1,18,00,000 ₹1.2 Cr | 45,50,000 ₹45.5 L | 28,04,840.36 ₹28.0 L | 16,00,000 ₹16 L | 17,85,000 ₹17.9 L |
| 9.00 | Sch 'A' Part-VIII (Summer & Cooling Appliances) Lump sum price worked out by the contractor for (Summer & Cooling Appliances) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. | 1 | Lump sum | 61,58,708.81 ₹61.6 L | 40,94,405 ₹40.9 L | 36,09,600 ₹36.1 L | 87,25,000 ₹87.3 L | 77,00,000 ₹77 L | 1,32,24,727.1 ₹1.3 Cr | 44,00,000 ₹44 L | 48,10,000 ₹48.1 L |
| 10.00 | Sch 'A' Part-IX (Lightening Protection System) Lump sum price worked out by the contractor for (Lightening Protection System) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. | 1 | Lump sum | 1,55,118.06 ₹1.6 L | 3,59,360 ₹3.6 L | 1,15,200 ₹1.2 L | 1,42,000 ₹1.4 L | 1,50,000 ₹1.5 L | 2,23,370.4 ₹2.2 L | 1,50,000 ₹1.5 L | 2,07,000 ₹2.1 L |
Updated dates
Tender Value
₹27.9 Cr
EMD Value
₹15 L
Closing Date
7 May 2026, 6:00 pmClosed
Chief Engineer Jabalpur Zone
Q Chief Engineer Jabalpur Zone ridge road Jabalpur 482001
PROVN OF SINGLE MEN BARRCKS INCLUDING COOK HOUSE FOR AGNIVEER AT THE RENADIERS REGIMENTAL CENTRE JABALPUR
2025_MES_730535_2
752998A PROVN OF SINGLE MEN BARRCKS INCLUDING COOK HOUSE FOR AGNIVEER AT JABALPUR
Open Tender
Civil Works
545 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE P No 1 Jabalpur
₹15 L
Yes
22 May 2026
12 Mar 2026
14 May 2026
12 Mar 2026
7 May 2026
13 Apr 2026
SCHEDULE "A" Part-I (Building/Structures) (To be quoted by the tenderer)
Item No 01 : Design and construction of Single Men Barracks incl Cook House and Dining hall For Agniveers. Complete all specified in soil bearing capacity report, design basis report drawings and tender documents.
Sch 'A' Part-II (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES.
Sch 'A' Part-III (External Water Supply) Lump sum price worked out by the contractor for (External Water Supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES.
Sch 'A' Part-IV (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES.
Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES.
Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES.
Sch 'A' Part-VII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES.
Sch 'A' Part-VIII (Summer & Cooling Appliances) Lump sum price worked out by the contractor for (Summer & Cooling Appliances) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES.
Sch 'A' Part-IX (Lightening Protection System) Lump sum price worked out by the contractor for (Lightening Protection System) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES.
Sch 'A' Part-X (Fire Fighting System) Lump sum price worked out by the contractor for (Fire Fighting System) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
Sch 'A' Part-XI (Internal Water Supply) Lump sum price worked out by the contractor for (Internal water supply) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
Sch 'A' Part-XII (Internal Electric Supply) Lump sum price worked out by the contractor for (Internal Electric supply) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES.
Note for Srl No 2 to 15 The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 15 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule
Schedule 'A' Part-XIII (Miscellaneous items of works)
External Electric Supply
Item No 04 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed
Item No 05 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed
Item No 06 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved and make given as per CA factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : -
BUSBAR :- (i) 450 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance
INCOMING
(a) MCCB 4 Pole 315 Amps, 36 KA with Rotary Handle, microprocessor release adjustable amp Ics = 100% Icu as per IEC 60947-2 , Adjustable Over load from 0.5 to 1*In , Adjustable Short Circuit from 2 to 10*Ir , Adjustable Neutral Protection - N, N/2,OFF for 4 Pole MCCB , Inbuilt Thermal Memory- 02 No (incoming)
(b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No.
(c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No.
(d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set
(e) Copper wound with CTR 300/5 - 03 Nos
OUTGOING
(i) MCCB 4 Pole 200 Amps,25 KA at 415 volts - 02 No.(SM Bk + 1 No Standby)
(ii) MCCB 4 P 63 Amps,16 KA 415 volts - 02 Nos (DG Set Panel & Centralised Cooler)
(iii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set
Item No 07 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Item No 08 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Item No 09 : S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed.
Item No 10 : S&F earth continuity conductor or main earth lead of 25 X 3.15 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed.
Item No 11 : S & F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and Bolts complete as all specified and as directed.
Item No 12 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed.
Item No 13 : Material and labour for LT 1100 volts (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-120 sqmm complete all as specified and as directed.
Item No 14 : Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying one coats of black bituminous paint complete all as specified and as directed.
External Water Supply
Item No 15 : Supplying and laying 100 mm bore Ductile iron Pressure Pipes, Centrifugally Cast (Spun), Class “K-7” with both side flanged ends confirming to IS 8329 in standard lengths with inside cement mortar lining and black bitumen external coating and including necessary DI specials as required complete all as specified and as directed.
Item No 16 : M&L for tapping in existing DI pipe lines 150 mm dia and inserting tee of 150x 100 mm and all as directed.
Item No 17 : Construction of brick masonry valve pit of size 1200 mm x 1200mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified.
Item No. 18 : Supply and fixing cost for MS reducer, bail plug and MS strip for centering and providing support for fixing stranded steel rope complete all as specified and directed.
Item No. 19 : Trial Boring/Drilling pilot boring including reaming of bore of 200mm to 300mm dia (suitable for 200mm casing upto 20m depth and 150 mm casing from 20m to bore level) IS: 2800 (part I), upto 140m to 180m depth ( if encountered hard rock which cannot be encountered at certain depth then pilot boring size can be reduced to an extent of 250 mm dia on direction of Engineer in Charge ) below ground level & lowering of MS pipe by any suitable method (by DTH-cum-rotary or reverse rig method) to depth below ground level in any type of strata/soil/rock with sand or loose boulder including disposal of materials obtained (soil, rock,etc) from boring to distance not exceeding 40 meter with & including deploying required rig, machinery, T & P equipments, etc complete all as specified and directed.
Item No. 20 : Supply, assembling,lowering and levelling 150 mm nominal bore MS ERW ISI marked plain end casing black pipe having wall thickness minimum 5mm IS 4270:2001/ (as per relavant IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e steel sockets, coupling, jointing and painting with two coats of bituminous paint of exterinal surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed.
Item No. 21 : Supply, assembling,lowering and levelling 150 mm nominal bore MS slotted ERW ISI marked plain end casing black pipe having wall thickness minimum 5mm as per IS 8110 (2000) / IS 14270: 2001 (part 1) (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e steel sockets, coupling, jointing and painting with two coats of bituminous paint of exterinal surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed.
Item No. 22 : M & L for foundation of size 100x 100 x100.0 cm at ground level for holding tube well made of plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as directed by Engr-in charge (including necessary Earth work, excavation, returning filling, removal etc ).
Item No. 23 : Supply & Fixing of Main Submersible pump set complete which are suitable for 415 Volts, 3 Phase system, 10 HP (as suitable after carrying out yield test of bore well 75LPM to 150LPM Capacity, 50 Hz, Head 100 mtr to 150 mtr , 8 to 12 stage with delivery size of 80mm to 150mm suitable for 6" to 8 " bore complete all as specified and directed by Engr-In-Charge.
Item No. 24 : Supply & Fixing of Submersible cable 3 core, 10 Sqmm, PVC sheathed 1100V grade with copper conductor.
Item No. 26 : Development of tube well in accordance with IS : 2800 (part I) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, measuring static level & draw down etc. by step draw down method, including hire & labour charges of air compressor, tools & accessories etc. all as per requirement and direction of complete all as specifed and directed.
Item No. 27 : Supply, installation, testing and commissioning LT, 415 volt, 4 wire AC 50 Hz, cubical panel (feeder Pillar Box) factory made, out door, pedestral type, feeder pillar box, hutted roof, weather & vermin proof fabricated of 3.0mm thick MS black sheet, front & back double shutter opening type, spray two earth terminal suitable cable glands for all incoming and outgoing cable including grounting feeder pillar box 60 cm above ground level by providing 90 cm long angle iron of size 50 x 50 6mm welded on all the fours corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30cm, complete all as specifed and directed by engr - in -charge including the following accessories / components.
(a) Aluminium bus bar - 200 amps rating - 03 Nos. (for phases and 100 amps for neutral 01 No. insulated with proper colour coding phase wise). qty 04 (b) incoming MCCB 4 pole 63 Amp, 415 volt, 16 KA Thermal setting 70 % to 100 % - 01 No (Incoming) Qty 02 (c) Outing (i) MCCB TPN 32 Amp -05 Nos (lift & pump) (ii) MCB TPN 20 Amp -01 Nos (street light) (d) automatic star- Delta starter with single phase preventer and motor protection relay suitable for 10 HP pumps set -01 Nos (d) DOL starter 5 HP 415 volts -02 Nos (f) require necessary wiring / cable (size of cable depend upon the pump installed in the borewell) for connection of panel to a near by electric line
Item No. 28 : supply, installation, testing and commissioning LT, 415 volt, 4 wire AC 50 Hz, cubical panel (feeder Pillar Box) factory made, out door, pedestal type, feeder pillar box, hutted roof, weather & vermin proof fabricated of 3.0 mm thick MS black sheet, front & back double shutter opening type, spray two earth terminal suitable cable glands for all incoming and outgoing cable including grounding feeder pillar box 60 cm above ground level by prviding 90 cm long angle iron of size 50 x 60 x 6 mm welded on all the four corners, embeded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm, complete all as specified and directed by engr-in-charge including the following accessories/ components.
(a) Aluminium bus bar - 200 amps rating - 03 Nos. (for phases and 100 amps for neutral 01 No. insulated with proper colour coding phase wise). qty 04 (b) incoming MCCB 4 pole 63 Amp, 415 volt, 16 KA Thermal setting 70 % to 100 % - 01 No (Incoming) Qty 02 (c) Outing (i) MCCB TPN 32 Amp -05 Nos (lift & pump) (ii) MCB TPN 20 Amp -01 Nos (street light) (d) automatic star- Delta starter with single phase preventer and motor protection relay suitable for 10 HP pumps set -02 Nos
Item No. 29 : M&L for making foundation thrust blocks/support pillars for holding pipe line/clamp support etc by PCC 1:2:4 type B1 (using 20mm graded aggregate size) and using extra cement making good to surfaces complete.
Item No. 30 : Supply and Install of motorized Chemical Dosing suitable to inject solution upto 25 LPH comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM, assembly with agitator, dosing and agitator in single motor, agitator with SS sweep blade duly FRP coated, FRP tank 100 Ltrs capacity complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint with all accessories including UPVC pipe with valves and supportings complete all as specified and directed by Engr-In-Charge.
Item No. 31 : Supply only chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box complete all as directed.
Item No. 32 : Carrying out ground water survey to locate and identify suitable site (point) for potable and good yield water by State government approved departments/CGWB complete all as directed.
Item No. 33 : Material and labour for Electrologging test for borewell for finding out fluid content,porosity and permeability all as specifed and directed.
Item No. 34 : Testing of water sample and submission of reports for chemical and bacteriological analysis from the Government college /NABL cerified lab /State Govt Lab complete all as specified and directed.
Item No. 35 : Supply and filling Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in enquired grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Item No. 38 : Supply and fix pressure sensor switch having ambient operating tem -40 to 65 degree celcius , differential pressure range 0.7 bar to 4 bar , regulation range 0.2 bar to 7.5 bar ISO STANDADARD 228-1 complete all as specified and as directed.
Item No. 39 : Supply , Install, testing & commissioning of monoblock pumpset, 3 phase, 415 V, 50 Hz, bronze impeller,discharge 27-15 lps @ 12-24 mtr head complete all as specified and as directed.
Item No. 40 : S&F stranded Steel wire hot-dip galvanized, anti-rust of dia 8mm suitable for holding 10 HP submersible pump-motor set complete all as specfied and directed .
Item No. 41 : S&F coloured Borewell hole chart with complete bore details flex board of size 1mtrX0.5mtr incuding light arrangement complete all as specified and directed.
Road Path Culvert
Item No. 42 : S&F Traffic convex minor of size 800 mm dia unbreakable having clear and definite mirror image with upper class collar provided with suitable clamps & nut bolts. The complete set shall be fixed on MS pipe 65mm NB 2.0 meter long from Ground level duly powder coted/painted white/blue color etc complete all as specified and directed.
Sewage Disposal
Item No. 43 : Supplying and laying and jointing for (SN 8) DWCPE 180mm (OD)/ 163 (ID) conforning to IS-16098:2013 part -I with and incl jointing materials complete
Item No. 44 : M&L RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users.
Item No. 45 : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M x 3.0 M depth complete
Summer & Cooling Appliances
Item No 46 : Supply and installation of Double Skin Puff insulated Industrial Air Washer Unit having capacity 14725 cfm providing 80 % minimum cooling efficiency, sound pressure level @ 1m 72 db, cooling medium honeycomb pad, input power supply 415 V, 3phase, having 70 ltr water storage tank complete, AMCA certified Blower Fan all as directed. Make: Symphony 25 U industrial cooler and same as equivalent
Item No 47 : Design and supply, installing, balancing and commissioning of site fabricated galvanised sheet steel (GSS) ducts conforming to IS:277. This shall be fabricated either from, rectangular ducting complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangers, supports. Duct work shall be rigid and straight without kinks. All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used. Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m. The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per sqaure meter (GSM) of Zinc, GI sheet shall be lead free, eco friendly and RoHS compliant. All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.25 mm thick galvanised steel sheets. Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size and 12 mm dia for larger sizes. All nuts, bolts and washers shall be zinc plated steel.
All revits shal be galvanized or shall be made of magnisium-aluminium alloy. Self tapping screws shall not be used. The fabrication of ducts shall be carried out as per approved drawings and specifications of following thickness complete all as specified and as directed. Note: (i) The duct work shall be as per IS 655. (ii) The GSM sheets for ducts work shall confirm to class viii with Zinc coating of 120 gm/sq mtr as per IS-277. (iii) all work has be carried out by auth rep of OEM. (iv) Before execution of duct work contractor shall submit the layout drawing of duct. The drawing shall be approved lay rep of accepting officer.
Item No 47 (a): Supply & fix 0.63mm thickness sheet (24 gauge) for longest 750 mm and below
Item No 47 (b): Supply & fix 0.80mm thickness sheet (22 gauge) for longest side 751 mm to 1500 mm
Item No 48 : S&F Air Supply Grill Supply & Installation of Powder Coated Double Louver Air Supply Grill with damper for air balanceing and as directed.
Item No 49: S&F 9 mm thermal insulation using nitride rubber complete all as specified
Item No 50: S&F volume control damper complete all as specifed
Item No 51: S&F Canvass connection complete all as specified and directed
Item No 52: S&F acoustic insulation for dampening both airborne and structure borne noise produced by the fan, motor and airflow complete all as specified and directed
Item No 53: S&F acoustic insulation for dampening both airborne and structure borne noise produced by the fan, motor and airflow complete all as specified and directed
Item No 54: S&F MS cooler stand for mounting air cooler units complete all as specified and directed
Item No 55: Providing scaffolding for G+3 height building wk for execution of duct work having plinth area Approx 8000 sqm and complete all as specified.
Item No 56: Supply, hoisting and fixing pvc three layer water storage tank of capacity 2000 ltr including all fitting arrangement complete all as specified and as directed (Note: For centralized air cooling system and solar water heater)
Item No 57: M&L for fabrication of angle iron frame stand with equal angle of size 40x 40 x 6 mm, suitable size of plate including nut bolt waher etc. Fixing arrangement complete all as directed by Eng-in-Charge.
Item No 58: Supply and fixing Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore IS marked including all fitting arrangement such as elbow, bends, sockets, union etc required at site complete all as specified and directed.
Item No 59: Supply and fixing 15 mm dia, Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Item No 60 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : -
BUSBAR :- (i) 150 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance
INCOMING :-
(a) MCCB 4 Pole 63 Amps, 25 KA, 16 KA - 02 No
(b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No.
(c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No.
(d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set
(f) Copper wound with CTR - 03 Nos
OUT GOING
(i) MCB 4 P 'C' Series 6-10 A Amps, 415 volts - 06 Nos (ii) DOL starter suitable for 1.5 KW motor, 3Ph -06 Nos
(iii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set
Item No 61 : Supply, installation,commissioning refrigerator, electric driven (single phase), capacity 300 Litres. BEE 5 star rated all as specified and directed.
Item No 62 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA all as specified and directed.
Item No 63 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA all as specified and directed.
Electric Lift
Item No 64 : Supply, install, testing & commissioning passenger lift, speed 1 to 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply confirming to IS 14665, suitable to serve 8 passangers (544 Kgs) 4 floor i.e. G+3 upper floors with AC VVVF drive regerative typr (close loop) & automatic & manual dual controlled operation with/without attendant, center opening doors with door drive (lectric motor driven mechanism), sliding stainless steel doors, with moon rock finish of 16 gauge with view glass panel automatuc rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in Car, Machine room & near Ground floor landing door) complete all as specified. Note: The lift shall be provided with and including the followig:
(a) fireman switch (b) Automatic rescue device during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. (c) Battery operated emergency light (LED Ceiling Fitting) alarm (Speaker for emergency alarm system to be fixed) and stop button in car with reachable arragement for battery. (d) Suitable Nos LED light fitting in false ceiling (e) One sleek Circular, Heavy Duty Fan shall be fixed in the ceiling. (f) any deviation due to site requirement should be finalized during drawing approval without any extra cost. (g) Lift has to be inspected by state/central lift inspector. (h) Statutory approval as per state govt norms shall be taken after installation.
Fire Fighting System
Item No 65 : Supply and fix pressure sensor switch universal type having ambient operating tem -40 to 65 degree celcius , differential pressure range 0.7 bar to 4 bar , regulation range 0.2 bar to 7.5 bar ISO STANDADARD 228-1 complete all as specified and as directed.
Item No 66 : Supply and fix automatic air release valve 50mm dia suitable for domestic water with 50 mm gun metal stop valve complete.
Item No 67 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138.
Item No 68 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class "A", "B", "C" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B
Item No 69 : Supply only of 03x Fire bucket iron body red colour 10 L capacity for dry sand stored type including mounding stand paitnted with red colour ISI Marked IS : 2546 :2006, complete all as specified and as directed.
Item No 70 : supply , hoisting and fixing pvc three layer water storage tank of capacity 5000 ltr including all fitting arrangement complete all as specified and as directed.(Note: For SM Barrack 1x 5000 ltrs )
Item No 71 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B
External electric Supply DG Set
Item No. 72 : Supply, Installation, Testing and Commissioning of silent Diesel Engine driven generating set not less than 20 KVA or nearest standard size, 415 volts, 3 phase 4 wire, 1500 rpm, 50 Hz power supply with power factor 0.8 couple directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV + Emmission compliant) latest norms/regulation Noise level 75dB(A) at a distance of one meter with fuel tank, battery and standard accessories as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications of :-
ENGINE - 3/4 cylinders suitable to provide 20 KVA output, 1500 RPM under NTP conditions of BS:5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output 20 KVA/ 16 KW at 0.8 power factor 415Volts at the alternator terminal ALTERNATOR: single bearing alternator suitable for continuous operation generating 20 KVA at 1500 RPM, 415Volts , 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system, confirming to BS 5000/ IS 4722. The alternator is brushless type, screen protected, revolving field, self excited alternator confirming ti IS/IEC 60034-1, self regulated through an AVR. The alternator has the following features: a) ± 0.50% voltage regulation (max.) in static conditions (b) IP: 23 protection with insulation class H. (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) 3 phase reconnectable winding with 12 terminal brought out for connection. (e) dedicated winding speecially designed for 1 phase operation (f) double layer lap startor winding (g) PCC foundation complete as per manufacturer's design including anti vibration pads, necessary excavation & earth work in soft/loose, sand cushioning, grouting foundation etc.
Engine Starting – The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective Functions includes - Configurable alarm outputEmergency stop: Annunciated whenever an emergency stop signal is received by the control(a).Low Lube oil pressure warning and shutdown(b)High engine water temperature warning/ shutdown(c) Low coolant temp warning (d) Sensor failure indication(e)Low and high battery voltage warning (f) Weak battery warning
(g) Fail to start shut down(h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine(j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods.Alternator Protective functions includes : (l) High and Low AC voltage shut down (m) Under and over frequency shutdown / warning (n) Loss of sensing voltage input shut down (o) Battery charger alternator Fuel tank: Sub Base Fuel tank of 14 SWG MS sheet of adequate capacity to operate 8 to 12 hrs on 100% load. (b) Base Rail: Base Rail with integral fuel tank is provided.Batteries: For electrical control circuit ,12 Volts/88 AH battery for electrical starting of DG set
One set of accessories (As per manufacture's instruction) :-
(aa) Fuel tank with locking arrangement for 08 hours running on full load
(ab) Level indicator on fuel tank
(ac) Drain plug
(ad) MS class "C" piping , suitable dia and length for fuel inlet from tank to engine as per manufactures instruction.
(ae) Fuel strainer and fuel tank with air vent.
(af) Batteries heavy duty 12 Volts 88 AH lead acid type fully charged, indication of high flow charing changed : - 01 Nos
(ag) Cable connection from alternator to DG set control panel as directed
Tools (As per manufactures instructions):-
(aa) 'D' spanners - 01 Set
(ab) Ring spanners - 01 Set
(ac) Screw diver 5" to 12 " - 01 Set
(ad) Cutting plier 9 " - 01 No
(ae) Hammer 2 LBS - 01 No
Base frame arrangements . The engine and alternator would be coupled by means of specially diesigned flexible coupling and both the units including the radiator would be mounted on a rigid fabricated base to form a compact arrangement. The steel shall be Tisco / SAIL or equivalent make. NOTE: DG SET has to be inspected by rep of accepting officer/ IEM/ as applicable
Sound acoustic enclosure : CPCB approved sound acoustic enclosure sutable for above genrator set with complete set installed within canopy.
Item No. 73 : Supply, Installation, Testing and Commissioning of silent Diesel Engine driven generating set not less than 40 KVA or nearest standard size, 415 volts, 3 phase 4 wire, 1500 rpm, 50 Hz power supply with power factor 0.8 couple directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV + Emmission compliant) latest norms/regulation Noise level 75dB(A) at a distance of one meter with fuel tank, battery and standard accessories as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications of :-
Engine Starting – The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective Functions includes - Configurable alarm outputEmergency stop: Annunciated whenever an emergency stop signal is received by the control(a).Low Lube oil pressure warning and shutdown(b)High engine water temperature warning/ shutdown(c) Low coolant temp warning (d) Sensor failure indication(e)Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down(h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine(j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods.
One set of accessories (As per manufacture's instruction) :-
(aa) Fuel tank with locking arrangement for 08 hours running on full load
(ab) Level indicator on fuel tank
(ac) Drain plug
(ad) MS class "C" piping , suitable dia and length for fuel inlet from tank to engine as per manufactures instruction.
(ae) Fuel strainer and fuel tank with air vent.
(af) Batteries heavy duty 12 Volts 88 AH lead acid type fully charged, indication of high flow charing changed : - 01 Nos
(ag) Cable connection from alternator to DG set control panel as directed
Tools (As per manufactures instructions):-
(aa) 'D' spanners - 01 Set
(ab) Ring spanners - 01 Set
(ac) Screw diver 5" to 12 " - 01 Set
(ad) Cutting plier 9 " - 01 No
(ae) Hammer 2 LBS - 01 No
Base frame arrangements . The engine and alternator would be coupled by means of specially diesigned flexible coupling and both the units including the radiator would be mounted on a rigid fabricated base to form a compact arrangement. The steel shall be Tisco / SAIL or equivalent make.
Sound acoustic enclosure : CPCB approved sound acoustic enclosure sutable for above genrator set with complete set installed within canopy. NOTE: DG SET has to be inspected by rep of accepting officer/ IEM/ as applicable
Item No. 74 : M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floor/hard standing.
Item No. 75 : Earthing complete for various equipments with galvanised steel earth plate electrode 600 x 600x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I Strip 32 x 6 mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:4:8, type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion all as directed. Note:- Unit rate quoted is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate.
Item No. 76 : S & F earth continuity conductor for main earthing lead 32 X 6 mm strip burried in ground or fix in walls with bolts all as specified and directed by engineer in charge.
Lightening Protecting System
Item No. 77 : Earthing complete with galvanised steel earth plate 600×600 ×6 mm thick electrode earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32×6mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GI watering pipe of 20 mm bore medium grade and lugs, with and including galvanised iron strip 32×6mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
Item No 78 : S&F porcelain insulators 15 BMD type T with nut bolts / screws for fixing of aluminium strips on roof including provn of PCC of size 10cmX10cmX10cm height etc to avoid leakage of roof complete as directed.
Solar Power Plant
Item No 79 : Design, Supply, Installation, Testing and Commissioning of ongrid roof top Solar Photovoltaic Power Plant of capacity 100 Kwp conforming to MNRE specifications as amended, consisting of Mono PERC half cut Crystalline silicon solar cells, net metering facility, necessary protections including maintenance free chemical earthing,mounted on GI structure of suitable strength to withstand 150 km/hr air velocity with following components complete as required in Capex mode. (a) Solar Photovoltaic Module of capacity 630 Wp or above, manufactured in India,conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2 or AS PER LATEST RELEVANT IS. Solar Photovoltaic Module conversion efficiency shall not be less than 18 %. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.The performance of PV modules at STC conditions must be tested and approved by one of the IEC / NABL Accredited Testing Laboratories / Solar Energy Centre of MNRE
(b)Solar PV Modules shall be accompanied with Power Optimizer. Power Optimizer DC/DC converter with constant string voltage feature and which is connected to each PV module (upto 9kWp) or only one for every 2 PV Modules (>=10kWp) to provide individual module level maximum power point tracking (MPPT) for mitigating all types of modules mismatch loss, manufacturing tolerances and Partial shading. Power Optimizer should also be capable for advanced, real-time performance measurement with the help of control and communication gateway. The Optimizer to be able to instantaneously clamp DC voltage to 1V DC (safe DC) per optimizer when AC power is shut off for installer and firefighter safety and having technical specification complete all as specified and directed
(c) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.PCU should have all required components like inverter ,solar charge controller ,gate charger, load management system etc. and inverter string as per details given in para (d) below. ( d) Solar Grid Tie String Inverters with DC Safety Unit. The grid tie inverter should be designed to work with Power Optimizers module level MPPT (Module Power Point Tracking) providing constant string voltage and should have anti-Islanding feature.The inverter shall have an efficiency of at least 92% at 75% load. PCU shall have the facility of recording solar energy (KWh) generated at the output of PCU in addition to PV voltage, PV amps, Instantaneous PV power, daily PV power generated & cumulative PV power generated.Remote as well as local monitoring shall be provided. Module level Monitoring feature (to record all the important operational parameters and all the events) to monitor plant performance through external PC shall be provided. The communication shall be in such a way that the PCU can be monitored with the help of appropriate software from the centralized system.
The PCU shall have the facility to provide the analysis for reason of tripping, in cases of inadvertent tripping complete all as specified and directed (e) ACDB panel of 100 KW with minimum 04 Input 01 Out put with multi functioning meter and surge Protection Device completely. (i) The scope shall include standard load distribution boards/panels complete with cubicles, protection, metering, bus-bar system, cabling, wiring and other accessories, the quantities/ratings of which shall be finalized during detail engineering, duly certified by Chartered Engineer and approved by EIC. (ii) The ACDB shall be used to terminate single or multiple PCU AC outputs. The ACDB must have the following minimum features. (iii) Cables connecting bus bar should be minimum 3 times capacity of Solar Power plant. (iv) There should be provision in the system for measurement and display of Solar Power being fed to the load through inverter. (v) All the above boards/panels shall be metal enclosed, 415V switchgear type, complete with suitably rated all as specified and directed.
(f)The photovoltaic modules, mounting structure, Balance of system (BOS) and other components of power plant require proper grounding for protection against any serious earth faults. Redundant earthing methodology with two independent earth connections from each system has to be ensured for all the systems and equipment as given in the standards.For outdoor power electrical equipment, if any, earthing system network / earth-mat shall be interconnected mesh of mild steel rods buried in ground. For other areas in the solar plant, such as transformer area, switchgear area, etc. the earthing system shall consist of minimum two parallel conductors interconnected together. The detailed earthing design and calculation duly certified by Chartered Electrical Engineer shall be submitted for EIC approval. All the necessary statutory approvals, if any required, for the system shall be taken from nodal agencies complete all as specified and directed. (g) Online Data Monitoring System complete with accessories, software, server charges, sim data charges upto DLP
h) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (j)Provision of set of bi-directional GPRS based metering arrangement with CT at line end in SPV Plant and at line end of take over point for energy accounting purpose. (k) Took kit ,earthing kit etc related to Solar PV system and electrical system testing required for maintenance and monitoring of plant . (l) the design shall be got vetted from any one of the following agencies :- (i) National institute of Solar Eneregy (ii) Sardar swaran singh national institute of Renewable Energy (iii) Solar Energy Corporation of India (iv) The indian Renewable Energy development Agency .(v) Any of IIT (vi) MNRE/TERI approved agency (vii) STATE ELECTRICITY discoms . (m) Required cleaning arrangement for PV modules shall be provided.
(n) Comprehensive maintenance with material and solar cleaning on regular basis under DLP period of CA. (o) Lightning and surge voltage protection :The SPV power plants shall be provided with lighting & over voltage protection. The main aim in this protection shall be to reduce the over voltage to a tolerable value before it reaches the PV or other sub system components. The source of over voltage can be lightning atmosphere disturbances etc The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors. Lightning protection should be provided as per IEC 62305 standard. The protection against induced high-voltages shall be provided by the use of metal oxide variastors (MOVs) and suitable earthing such that induced transients find an alternate route to earth complete all as specified and directed. (p) Connections & interconnections by supplying & fixing required size suitable PVC insulated DC Copper conductor 1.1 kV grade power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
(u) One No All in one PC Intel i5 13 Gen/ 8 GB RAM/500 GB SSD Storage, UPS, Laser Printer, Computer Table with chair -1 Nos should be provided for Daily generation report printing. (v) The latest amendment in MNRE guidelines at the time of approval of design will supersede the technical specifications, if any. (w) Test certificate of solar panel submitted by the contractor complying all latest BIS or IEC standard as given in solar system devices goods order 2025.
Internal Electric Supply
Item No. 80 : S & F modular type TV Socket out let complete all as specified and as directed.
Item No. 81 : S & F modular type LAN Socket RJ 45 with complete box
Item No. 82 : S & F modular type Telephone socket RJ 11/12 with complete box
Item No. 83 : S & F for wall mount Panel of thickness 2.0mm of with 400 Amps copper rated bus bar 415 volts suitable for incoming MCCB 250Ammp,4 pole, 25KA -01 Nos Modules and for outgoing MCCB 4 pole 63 Amps, 16KA -4 Nos MCCB 4 pole 80 Amps, 16KA -2Nos Modules, MCCB should be fixed thermal magnetic type with spreader link and phase separator, necessary copper cabling , Phase indication lamp LED type , Digital ammeter, voltmeter Each module shoul be minimum size 450mmX450mm with necessary fixing arrangement including necessary provision for fixing on wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing color of wall complete all as specified and as directed.(Main Panel)
Item No. 84 : S & F for MCB Single pole rated capacity 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Item No. 85 : S & F modular MCB protected socket comprising of 32A MCB C curve, and 16/20 A Socket for AC/Geyser, modular switch 16A complete with Sheet metal Enclosure for 230 volt 50 Hz AC including all acessories as one complete set all as specified and as directed
Item No. 86 : S&F wall mount fan for kitchen 400mm ,3 blades button conrol ,material aluminium powder coated finish with cord , blade of plasic material including all fixing arrangement complete all as specified.
Item No. 87 : Supply and fix Decorative wall light made up of high grade engineering plastic material suitable for 9/12 W LED Complete all specied and as directed
Item No. 88 : M&L LED post Top of minimum 26 Watt, min lumen efficacy 100 lumen/watt, light IP 65 protection with fixing arrangement cpmplete all as specified and directed.
Item No. 89 : S&F wall mount Industrial Electric Kitchen Chimneys heat auto clean with motion sensor auto off function, touch sensor control LED lighting, metal housing brushless DC motor, LPG Leakage sensor, auto clean alarm, mood light, material tempered glass, noise level not less than 68 to 70dB and suction power 5000m3/hr with suitable stainless steel Hood type as per customized for site requirement connecting with all accessories including GI ducting and including all fixing arrangements, complete with safety features 12 yr warranty on motor (5 yr comprehensive), Auto clean alarm Mood Lt.
Please Enable Macros to View BoQ information
Schedule 'A' Part-II
(External Electric Supply)
Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated (earthed), screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 120 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed etc of the under mentioned type and sizes :-
(a) 3.5 core x 120 sqmm
(b) 2 core x 6 sqmm (Garden lighting & Post top Lantern)
(c) 4 Core X 25 Sqmm (Centralised Cooler)
(d) 4 Core X 16 Sqmm (for Submersible pump)
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Supply and laying sand cushioning with dry and clean washed sand over and under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid.
Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. As per IS 5820:1970, cover grade shall noty be less than M-20 concrete used, average breaking load capacity 300 KG
Supplying and laying unreinforced precast concrete cable cover, class HV Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. As per IS 5820:1970, cover grade shall noty be less than M-20 concrete used, average breaking load capacity 300 KG
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug , bolts, nuts & screws complete all as specified, type 410 SP - 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coat of aluminum paint & embedded portion of pole shall be painted with two coat of black paint including painting white & red alternate strips of 30 cm each externally from groundlevel uptp 1.2 m with synthetic enamel paint and writing numbering of poles with black paint on yellow background complete all as specified and as directed.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted.
M&L for GI tube light grade with all fitting laid in trenches of fixed to pole of size:-
(a) 50 mm Medium Grade
(b) 80 mm Medium Grade
M&L for PCC (1:2:4) type B2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and pilasters, buttresses columns, posts etc complete all as specified & directed.
M&L for Precast Cement Concrete(RCC) 1:4:8 type D2 using 40 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and minimum reinforcement as per relevant IS code and set in CM 1:6 complete all as specified and directed. ( Note :Reinforcement shall be measured and paid for separately.)
M&L for 40 to 80mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed.
S&F for lightning arrestor Expulsion type complete with all fittings, transmision/ distribution class , (RMS) discharge current 10 KA suitable for rated system voltage of 12 KV supply system with maximum continuous operating Voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of Zinc Oxide in hermetically sealed container and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed. Make:- SCHNENIDER or BHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE.
Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 160 KVA (Level-3), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from plus 5% to Minus 10% in steps of 2.5%, continuous rating of capacity 160 KVA
The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.5M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL,
exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :-
(a) One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c) Oil conservator tank with filter type, drain valve and oil level gauge.
(a) Externally had operated off-circuit Tap swith with position indicator and locking device (b) Conservator with oil gauge, filling hole with plug & drain hole with plug (c) Under carriage with four plain rollers (d) Oil filling hole cum air release plug- 01 No (e) Drain valve cum sampling valve- 01 No (f) Filter valve with plug- 01 No (g) Rating Plate & Diagram plate- 01 No (h) Ligting lugs for transformer- 02 No (j) Lifting lugs for lid- 02 No (k) Earthing terminals -02 No (l) Thermometer pocket- 01 No (m) Silica Gel breather- 01 No (n) Temperature rise indicator in oil 40 deg centigrade and windings 45 deg centigrade (o) Fittings accessories as per IS 1180 (part-I) 2014 Level-3 as per clause No 19.14.1.2 of SSR Part -I
(q) Oil lebel gauge incl oil level min and max (r) Exclusion vent -01 No (s) 6" Dial type thermometer with alarm and trip contact and maximum tem -01 No (t) Mounting arrangement shall be provided with two 75x40 mm channels 460 mm long (u) Suitable plinth of height 1.5 m above GL for installation of transformer (v) Cable terminattion box on both sides (HV Side & LV side for cable connections) (w) Plinth required for mounting Tranformer as per above desription Note (i) The contractor shall provide BEE certified, level 3, Transformer offered by Manufacturer (ii) The contractor shall lsubmit preliminary drawing for approval of GE.
Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed.
M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed.
Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed.
Supply and fixing LED Solar street light fitting 35/36 Watt mono crystalline solar panel with MPPT features of min 216 wh cap life PO4 battery including galvanized steel octagonal pole of height 6 from ground, PCC 1:2:4 earth work PCC in built, lithium ion battery, solar panel, charge controller with dusk down sensor with all connected accessories like nuts bolts clamps etc complete all as directed.
Supply and fixing HT 11 KV (Earthed) grade Cold shrinkable and termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 -185 sqmm complete all as specified and as directed.
Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed.
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed.
Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and as directed.
Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed .
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part III
(External Water supply)
Supply and lay pipe galvanized, “Medium class”, including fittings of dia 50 mm and all as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings of dia 40 mm and all as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings of dia 25 mm and all as directed.
Supply and lay pipe galvanized, “Medium class”, including fittings of dia 20 mm and all as directed.
S&F gun metal gate valve of following sizes screwed down high pressure with handle, Iron wheel (ISI marked) complete all as directed.
(a) 50mm bore
(b) 25mm bore
(c ) 20mm bore
Supply and fix Valves, Sluice, flanged of class 1.6 PN,100 mm dia and all as directed.
Supply, assembling,lowering and levelling 200 mm nominal bore MS ERW ISI marked casing plain pipe having wall thickness 5.4 mm as per IS 4270:2001/ (as per relavant latest IS) and jointing with electric arc welding, screwed and socketed in random length of 3 to 6 mtr, including necessary fittings i.e sockets, coupling, jointing and painting with two coats of bituminous paint of exterinal surfaces of pipe upto depth of 200 mtr below ground level complete all as specified and directed.
Supply, lowering and fixing Heavy Grade GI column pipe, ISI marked both end flanged 80 mm dia bore in 3 mtr length having wall thickness as per relavant IS as per IS-1239 complete including rubber gasket, slot cutting in flanges for passing of submersible cable and nut bolts etc all as specified and directed by Engr-in-charge.
Supply and Fixing in position mild steel cap made of MS plate 5mm thick with an internal threading and locking arrangement having opening for column pipe and submersible cable, for housing pipe of 200 mm dia complete all as specifed and directed.
Supply and fixing 80mm bore Non Return Valve as perrelavant IS, PN rating 1.0 ISI marked all as specified and directed.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IV
(Road, Path Curvert)
Excavating over areas, n exc 1.5 m deep and getting out soft/Hard Soil
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil
Add to (or deduct from) last item for every 3 cm or part thereof above or below 15 cm average depth in soft /loose soil
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M&L for soling (sub base) with broken boulders or quarried stones 200 mm thick spread interstices filled surface formed rolled and consolidated to required gradient and camber all as spfd.
M & L for Laying and compacting 150 mm thick (compacted thickness ) WMM laid in two layers of 75 mm each Wet Mix Macadam (WMM) grading as pe table 400-13 of MaRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with wate to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradien and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MaRTH specifications for Road and Bridge works 2013 complete all as specified.
Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 2 - 0.30 kg/sqm on surface of bitumen including preparation of bitumen surfaces as specified in Table 500-5 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of bitumen surfaces all as specified and directed .
M&L premixed bituminous macadam laid/rolled and compacted to required gradient and camber with using 20 mm graded stone agg and paving bitumen 4% by the weight of total mix (consolidate thickness 75 mm or less as required ) complete all as specified and as directed.
Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 7-1 kg/sqm on surface of WMM/WBM including preparation of WBM/WMM surfaces as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of WBM/WMM surfaces all as specified and directed .
M & L for laying bituminous premix asphaltic semi dense concrete avaraging 40mm consolidated thickness with 5.5% binder content by weight of total mix using asphalt mechanical mixer plant & consolidated with 8to 10 ton power road roller to reqd level gradient camber and super elevation.
Continuous edging with roughly squared sand stones of size 30 cm x 5 cm (30cm deep & 5 cm thickness), length of each patti not less than 60 cm Complete of using sand stone/Katni sone all as specified and directed.
M&L preparation of road surface and applying thermoplastic relflective paint in white or any tint marking of min 2 mm thick single coat as in center line and edge line road marking of 150/100 mm width using ''HOT MARK" thermoplastic modern propelled road marking machine as directed incl all ingredients such as blinder, glass beads, Titaniumdioxide calcium carabonate inter fillers thermroplastic requirement for glass beads shell be the Table No 650.4 of MOT specifications incl spraying of glass beads etc all as per manufactures instrustions.
Cement concrete type D-2 1:4:8 (using 20 mm graded aggregate) as in foundation filling and mass concrete , sub base complete all as directed.
Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Supply and fixing in repair cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. →
Supply and fixing in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed
S&F 600 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed.
M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 600 mm bore complete all as specified and directed.
S&F 450 mm bore Reinforced concrete pipes class NP3, laid and jointed complete with collars complete all as specified and directed.
M&L PCC 1:3:6 type C2, 40mm graded agg as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 450 mm bore complete all as specified and directed.
Returning filling in including spreading levlling ,watering and well ramming in layers nexc 25cm thick complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part V
(Sewage Disposal)
Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed.
Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed
Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed.
Removal of excavated material (soil) to a distance exc 50 m n. exc 250 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 complete
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:4).complete all as specified and as directed.
M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as specified and as directed. .
M&L for 15 mm thick rendering in cement mortar (1:3) on brick / concrete/ stone surfaces mixed with water proofing compound as per manufacturer instruction , finished even and smooth using extra cement complete all as specified and as directed.
Supply only water proofing compound.
M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete
M&L for cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as in coping complete
M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed.
S&F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed
S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for cement concrete type B2 , 1:2:4 using 40 mm gradded stone aggregate in surface channels and drains complete
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VI
(Area Drainage)
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified
M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed.
M&L RCC M - 25 (Design Mix) (20mm graded agg) as in footing etc complete.
M&L RCC M - 25 (Design Mix) (20mm graded agg) as in walls, retaining walls, basement walls, and the like , of any thickness including attached pilaster and butresses, footing etc complete.
Use & wate formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batte
Use & waste formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter
M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed.
M & L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete.
Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and directed.
Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part VII
(Site Clearance)
Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft soil.
Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil
Earth filling (for site development) incl raising (or lowering) not exc 1.5 m high earth spreading in layers n.exc 30 cm thick watering and rolling and finishing to reqd size and shape etc
Removing excavated material to a distance exc 500m but n exc 1.5km, depositing where directed at a level n exc 1.5 M above the starting point.
M & L for Grubbing up tree trunk (exc 30 cm but n exc 100 cm) including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site
M & L for Grubbing up tree trunk (exc 100 cm but n exc 150 cm) including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site
Total carried over to BOQ Rs.
SIGNATURE OF CONTRACTOR
DATED _________
Schedule 'A' Part VIII
(Summer & Cooling Appliances)
Supply, Install, Testing and commissioning of 'Solar Hot Water System' (Flat Plater Collector) based on indirect transfer of heat of capacity 400 LPD including powert supply backup with 4 kQ heater following accessories all as specified and directed: (i) Solar flat plate collectors shall be constructed strictly as per norms of Ministry of Non conventional Energy Sources (MNES), Govt of India and BIS specification. (ii) Collectors support Structure:- The support structure for the collectors shall be of MS angle of size not less than 50 x 50 x 6 mm. The strcuture shall be provided with suitable flat iron sections to fix collectors on structure and prevent from uprooting during heavy winds.
(iii) Hot Water Storage Tank along with structure and insulation: Tank shall be of the full capacity as per the system. Tank shall have thermal stratification to prevent mixing of cold and hot water. The tank shall be made of 20 Gauge (.91 mm) thick stainless sheet SS-316 L with glass liner. Hot water tank shall be insulated with 100 mm thick Rock Wool of density 48 kg/m3 insulated with using chicken wire mesh and vapour barrier. On the top of the insulation, aluminium cladding with 26 SWG aluminium sheet. (ii) Coldwater Tank of suitable capacity (paid separately)
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
Supply, installation,commissioning hi wall split units capacity 2.0 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum inverter type 5 star rating 5.2 of capacity complete all as specified.
Supply, installation,commissioning Deep freezer hard top 400 litres capacity having double door all as specified and directed.
Supply, installation,commissioning of Water cooler fully stainless steel, electric driven and single phase having approx storage 120 litres and nominal cooling capacity 60 Litres per hour all as specified and directed.
Supply, installation,commissioning of Water cooler fully stainless steel, electric driven and single phase having approx storage 80 litres and nominal cooling capacity 40 Litres per hour all as specified and directed.
Supply only bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R - 134a refrigerant including PVC bottle of capacity 20 ltrs for water storage all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part IX
(Lightenning Protection System)
Supply & fix aluminium strips 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed by Engr - in - Charge .
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw , drolled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete as directed .
Supply and fix air termination rod single pointed aluminium rod length 12 mm dia & 300 mm long .
M&L for 100 mm thick PCC 1:2:4 TYPE B1 using 20mm graded stone aggregate as in floor.
Supply and errect vertically Galvanised, medium grade pipe 20 mm diameter complete with fittings for raising height for air termination rods all as specified and directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part X
(Fire Fighting System)
S & F for MS ERW pipe 50 mm dia as per IS 1239 including cutting /threading/welding etc for providing connections and including all types of reqd fittings , clamps, nout & bolts etc for laid on wall/ceiling/ floor/ all as specified and directed.
S & F for MS ERW pipe 25 mm dia as per IS 1239 including cutting /threading/welding etc for providing connections and including all types of reqd fittings , clamps, nout & bolts etc for laid on wall/ceiling/ floor/ all as specified and directed.
S & F Valve,gate/ball, screwed,15 mm, brass with iron wheel head, screwed both ends for iron/MS pipe and complete all as directed.
S & F Valve,gate/stop, screwed,50 mm , brass with iron wheel head, screwed both ends for iron pipe and complete all as directed.
M & L for RRL hose reel of 20 mm dia 30 mtr long including hose box conforming to IS - 5132 complete all as specified and as directed.
S & F for booster(pressure) pumps / Terrace pump for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 450 LPM discharge including suitable size automatic pressure maintained pump starter complete all as specified and as directed. Rates are incl of reqd foundation wk, hur type shed for pump set made of GI sheet & angle iron, all electrical and water connection etc complete all as specified and as directed.
M&L for painting over steel/ iron Surfaces of any description, over 10cm in width or girth,not otherwise described incl preparation of surfaces, appying red oxide primer 01 coat, and 02 coat of synthetic enamel paint complete all as specified and as directed.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part-XI
(Internal Water Supply)
S&F 15 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors incl cutting chasing and making good complete all as specified and directed.
S&F 20 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25 mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 50mm bore galvanized steel tubing, medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F in 20mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge.
S&F in 25mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge.
S&F in 50mm bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed by Engineer in Charge.
S&F in 15mm dia pillar taps, cast copper alloy with capstan heads chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed.
S & F in for long body Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed, 15 mm, fancy type, chromium plated fixed complete.
S & Fin for Angle cock/Stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed , 15 mm fixed complete.
S&F in PVC connections 15 mm size with brass nuts both side of length 450 mm complete all as specified and directed .
S & F in Brass chromium plated wall Mixer (2/3 hole) for mixing hot & Cold water arrangement, long shank suitable 15mm bore of pipe of approved quality screwed down for iron pipe and fixed
S&F in chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by Engr-in-charge.
S&F brass chromium plated overhead shower 125mm size ( square/ rectangular ) with or without swivel joints including fixing to steel pipe of 15mm bore complete all as specified and directed .
S & F in Vitreous China urinals half stall white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engr-in-charge.
S & F in Urinal spreader of PTMT any color for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engr-in-charge.
Total carried over to BOQ Rs.
Signature of Contactor
Schedule 'A' Part-XII
(Internal Electric Supply)
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories ncluding PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan/wall fan point controlled by one, one way switch 5 Amps and regulator
(c) One light point controlled by , two way switch 5 Amps
(d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
Description all as per item No. 1 here in before but using 4.0 sq mm single core copper conductor two nos FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete.
S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified.
S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 1.5 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 1.5 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 1.5 sqmm cable,one run of 1.5 sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSHH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSHH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSh cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Four runs of 10 sqmm cable, one runs of 10 sqmm cable and one run of PVC conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSh cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note:- Two runs of 10 sqmm cable,one run of 10 sqmm cable and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCCB DB VTPN 4 way Vertical type with min 200 Amps rated copper bus bar 415 volts for incoming MCCB 4 pole -01 Nos and out going 12 Nos MCB Modules with double door with magnitic locking system including blanking plate and necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. (First floor/Second floor/Third floor)
S & F for sheet metal enclosure MCCB DB VTPN 4 way Vertical type with min 200 Amps rated bus bar 415 volts for incomming MCCB 4 pole -01 Nos and out going 12 Nos MCB Modules with double door with magnitic locking system including including blanking plate necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.(Ground floor)
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing color of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCCB four pole rated capacity 80 Amps,( nearest standard size ) 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed.
S & F for MCCB four pole rated capacity 63 Amps,( nearest standard size ) 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed.
S & F for MCB DP rated capacity 32 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB DP rated capacity 25-16 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB DP rated capacity 40 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB DP rated capacity 63 Amps, (nearest standard size ) 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator modular type and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S & F for energy efficient exhaust fan of 380 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt , embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.
S & F for energy efficient exhaust fan of 450 mm sweep made of metal body complete with louver with bolts nuts and washers, bolt , embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.
S & F surface/recess mounted ceiling light of capacity 36 watt, approx size of 2x2 ft , 230 volts with CRCA housing luminous efficacy not less than 120 lumen/W with and intregrated electronic driver connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed.
S & F surface mounted mirror light of capacity 5 watt, , 230 volts with CRCA housing with and intregrated electronic driver with luminous efficacy not less than 120 lumen/watt connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor with flexible conduit of suitable size complete all as specified and as directed.
S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminum housing, high transmissibility diffuser, high lumen ouput box type fitting, luminous efficacy not less than 120 lumen/watt 230 volts and integrated electronic driver connector block etc LED Chip, Driver and housing should be of same make complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multi stranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S & F for Energy saving new generation environmental friendly long life versatile pressure die cast aluminum IP 66 for security light fitting luminaries with high power LEDs as light source and electronic driver of capacity 35 watts , luminous efficacy not less than 110 lumen/watt LED Chip, Driver and housing should be of same make with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories with junction and other accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed.
M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of GI wire up to 7.5 mtr connected to earthing point complete all as specified and as directed.
Total carried over to BOQ Rs.
Signature of Contactor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
drg.rar
Additional Documents • 8.71 MB
BOQ_846903.xls
BOQ • 0.75 MB
TENDER.pdf
Tender Documents • 5.52 MB
Download all tender documents and submit your bid