Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L3₹28.2 L+₹81,895 (2.99%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L4₹28.5 L+₹1.0 L (3.76%)Rejected-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L4 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | L5₹28.5 L+₹1.1 L (3.87%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 5 | L6₹28.6 L+₹1.1 L (4.16%)Rejected-AOC | L6 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
₹36.1 L
EMD Value
₹72,300
Closing Date
21 May 2020, 6:00 pmClosed
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
SPECIAL REPAIR TO BLDG NO 26, JCOs LIVING OF 132 SATA REGT UNDER GE NASIRABAD
2020_MES_340932_1
83503
Open Tender
Civil Works
Item Rate
180 days
NASIRABAD
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
GE NASIRABAD
₹72,300
Yes
23 Jul 2020
27 Apr 2020
27 May 2020
27 Apr 2020
21 May 2020
9 May 2020
Amount
Demolition of cement concrete (unreinforced ) in floors and pavings n. exc 15cm thickness (above or below GL) complete all as specified and directed
Dismantling floor, hearth or wall tiles, including cement mortar, removing serviceable tiles from site & rubbish off the premises, complete all as specified and directed.
Taking down cement or cement lime plaster or stone / brick wall, ceiling including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from the frame ) area n. exc 1.5 Sqm each complete with hold fasts etc complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from the frame ) area exc 1.5 Sqm but n. exc 4.0 Sqm each complete with hold fasts etc complete all as specified and directed.
Taking down shutters of any description exc 1.00 Sqm but n. exc 2.00 Sqm and easing, ajusting and also refixing builders hardware as required and renewal of unserviceable screws and refixing in the same opening complete all as specified and directed.
Demolition of brick work/ stone masonary built in cement mortar etc complete all as specified and directed.
Dismantling plain or corrugated steel sheeting of any gauge,thickness including manglore Pattern roofing tiles on roof covering complete all as specified and directed.
S&F in repair roof trusses (framed ) trussed purlins, crane gantries, rails and fastening and heavy brackets framing (Beam, tee, angle, channel or flat section ) including distance pipe, cleats conforming to Fe-290 (Gde 165-E) etc including dismantling frame trusses complete all as specified and directed. Note: Weight shall be verified by the GE.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws all incl fixing bracket suitable for galvalume sheet profile complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F in repair false ceiling with Everest Fibre cement designer tile ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS : 14862 ) of size 595 x 595 mm and any one of the desin ( occeanic, lake & hill cascade or electra ) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @ 120 gms, both side inclusive ) consisting of main "T" runner with suitably spaced joints to get required length, and 15 x32mm made from 0.30mm thick sheet, and cross 'T' of size 15x32mm made of 0.30mm sheet, spaced between main 'T' at 600mm c/c to form a grid of 600 x600mm and wall angle of size 15 x20mm made of 0.30mm thick sheet and laying false ceiling files in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlins etc, with dash fasterners, GI adjustable rods of 3mm dia with galvanised butterfly level clips, spaced at 12mm c/c along main T, bottom exposed width of 15mm of all T- sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, at any heights, complete all as spcified and directed.
M&L for brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for walling Random rubble masonary uncoursed well bonded bedded and solidly hearted and built in cement mortar 1:6 etc complete all as specified and directed.
Ditto all as per item No. 14 here in before but except stone complete all as specified and directed.
Extra over stone masonary for hammer dressing to face beds and joints mixmum depression on face (sand stone) n. exc 20mm depression etc complete all as specified and directed.
M&L for rendering in cement mortar (1:6), 15mm thick on other than fair faces of brick work / stone masonary surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar (1:4) on ceiling on other than fair faces of brick work / concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound @ 3 % by weight of cement on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement, complete all as specified and directed Note: WPC shall be measured and paid separately.
M&L for rendering 10 mm thick in cm (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Dismantling loose / disintergrated portion of RCC Chajjas, bend shelves, beams balconies and similar work at any position or any height and doubbing out with PCC 1:1.5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces of reinforcement and provision of necessary supporting form work and including 10mm thick plastering in CM 1:4, finished fair and even, complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in floors complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.18 Sqm but not exc 0.36 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but not exc 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedding in cement mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 7 to 8mm thick in vertcial surfaces of size exceeding 0.11 Sqm but not excceding 0.18 Sqm set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick screed plaster in cement mortar 1:4 complete all as specified and directed.
Ditto all as per item No.23 above but in skirting over 10mm thick screeding in cement mortar 1:4 complete all as specified and directed.
M&L for machine cut kota sotne slab, 20-25mm thick over and including 15mm thick screed bedding in cement mortar 1:6 as in floors, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing with mirror polish complete all as specified.
M&L for machine cut kota sotne slab in skirting / steps / risers of reqd size, 20 to 25mm thick & including 10mm thick screed bedding in cement mortar 1:4 as in floors, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing with mirror polish complete all as specified and directed.
M&L for RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in slab supported on wall walls beams and columns in floors roof landings complete all as specified and directed.
M&L for TMT bars of 6 to 8mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia complete all as specified and directed.
M&L for form work for flat fair finished surfaces of concrete to soffits of suspended slabs such as roof slab not exceeding 200mm thick complete all as specified and directed.
M&L for 16 to 18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window -cills, cooking platforms and like pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding of edge laid over 15mm thick screed bed in CM (1:6) including rounding of edge of stone slabs one edge complete all as specified and directed.
M&L for rolled mild steel work as in door frame (chowkhats) including provn of 10mm dia deformed bar welded horizontally to bottom of frame conforming to Fe-290 (Gde 165-E) including preparing back of chowkhat and applying two coats tar and sanding newly tarred surfaces with clean sharp sand complete all as specified and directed. Note: Weight shall be verified by the GE.
S&F Second class HW, plain, solid, straight chowkhats & frames, wrought, framed, rebated on the solid, rounded or chamfered, put together glue pinned at joints complete all as specified and directed.
S&F Second class HW 35mm thick, plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and styles as per IS : 1003n (part I), Kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F solid PVC moulded door frame of size 50mm x 47mm made out of 5mm prelam coloured PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet as reinforced with MS square tube and fixing in opening as specification & drawing complete all as specified and directed.
S&F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick, (styles) with 2,4 or 6 raised panel design with 2mm thick moulded prelam (Nut Brown colour ) PVC sheet on the front face & 2mm prelam (Nut Brown colur ) PVC sheet on back face, and fixing inthe frame at site as per specification and drawing on page 161 of SSR (Part -II ) 2010 complete all as specified and directed.
Taking down old u/s steel window / ventilator and S&F steel window / ventilator glazed and gauged (combination) with side hung / top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame including guard bars and necessary cooler arrangement in window complete all as shown in drg No. CEBZ /TD / 14/11 Sheet No. 1/7 to 7/7 complete all as specified and directed.
Dismantling boarding of any description fixed with nails in any position and M&L 18/19mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws, including teak wood lipping 19 x 6mm thick fixed with nails in shelves, partition and pelment boxes, cupboard, shelves etc all as specified and directed.
S&F continous (Piano) hinges, mild steel, bright finish, width of flaps (when open) 30mm complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of apertature 1.40mm and fixed with tinned tacks or stainless steel wire staples all as specified and directed.
S&F 3mm thick glass, ordinary quality, 3mm thick fixed with oil putty size of glass not exc 0.50 sqm in each pane, complete all as specified and directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty in square n. exc 0.50 Sqm in each pane, complete all as specified and directed.
S&F MS butt hinges, medium weight, cold rolled, ISI marked of size 100mm, complete all as specified and directed.
S&F 100mm butt hinges, extruded aluminium alloy / stainless steel with galvanised mild steel hinge pin anodised and fixed, type C-21 complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section all as specified and directed.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F hasp & staple 100mm size safety type, aluminium anodised with mild steel hinges pin including bolt of hinge plate & fixed with screws complete all as specified and directed.
S&F 300mm long alumimium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium alloy all as specified and directed.
S&F 140mm floor door stopper of aluminium alloy body and togue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed.
S&F 25mm mild steel chromium plated curtain rod powder coated finished complete all as specified and directed.
S&F decorative type curtain rod bracket with cap of mild steel powder coated suitable for 25mm dia rod complete all as specified and directed.
S&F in repair Mild steel 300mm rat tail rod pattern springs including roller and roller plate complete.
M&L for cutting holes in brick walls (N exc half brick) for inserting hold fasts and making good dismantled portion in PCC 1:2:4 type B1 (Using 20mm graded crushed stone aggregate) and cement mortar (1:3) complete all as specified and directed.
M&L for mild steel work such as hold fasts, hooks, clamps etc and similar work conforming to Fe 290 , Gde -165 complete all as specified and directed.
Taking down old unserviceable 15mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
Taking down old unserviceable 20mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
Taking down old unserviceable 25mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed.
S&F 15mm GI water tubing (Concealed type), medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
S&F 20mm GI water tubing, medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
S&F 25mm GI water tubing, medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed.
Refixing old 15mm GI tubing (Concealed type) galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed.
Refixing old 20mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed.
Refixing old 25mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed.
Dismantling of existing unserviceable RCC/PVC water tank and S&F 1000 litre capacity rotational moulded polythene water storage tanks double layer (cylindrical vertical with closed top) hoisted & fixed in position complete all as spcified.
S&F ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of 20mm dia and fixed (minimum weight 210 gms)
S&F in repair tubular towel rail, chromium plated brass 20mm dia 'D" type 60cm long between flanges complete all as specified and directed.
S&F in repair brass chromium plated shower rose of 125mm size with swivel joints, including fixing to steel pipe or union of 15mm bore complete all as specified and directed.
Supply and fixing in repairs PVC cabinet of size 450 mm x 600 mm with mirror of good quality with shelves in bath fixed complete to walls complete all as directed by Engineer-in-Charge Make : Prayag (Cat No. 556) or equivalent as approved by the GE.
S&F in repair PVC valve less, syphonic action type flushing cistern, 10 Litre capacity, low level, white with inlet, ball vlave float, handle including PVC rigid pipe 32mm bore as flush pipe fixed on walls by drilling holes and using PVC rawl plug of suitable size complete all as specified and directed.
S&F in repair wash hand basins vitreous china, coloured flat back size 550 x 400mm fixed including bracket complete all as specified and directed.
S&F in repair PVC connection, heavy duty 15mm bore, 45cm long with 2 Nos PTMT nuts of approved quality complete all as specified and directed.
S&F in repairs 15mm pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure for iron pipe fixed complete all as specified and directed.
S&F in repairs 15mm bore cast copper alloy chromium plated bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair angle valves 15mm bore , cast copper alloy chromium plated with long sunk and cap (Concealed type), screwed down high pressure screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed.
S&F mild steel framed work such as grills, grating cooler stands, etc, with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. Note: Weight shall be verified by the GE.
S&F in repairs vitreous china wash down water closet pedestal pattern pan white with trap including connection to existing out joint pipe, flushing pipe or Cistern, anti-syphonage pipe, including making, etc complete including making goood to floor etc complete all as specified and as directed.
Taking out old u/s water closet and S&F vitreous China "Orissa pattern" size 580 x 440mm" coloured, with intergral foot rests with vitreous china 'P' or 'S' trap front or back inlet including connection to trap and to flushing pipe, anti syphnage pipe and making good the floor to match the existing complete all as specified and directed.
Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed.
Taking down 100mm / 75mm dia AC rain water pipe (any size or pattern ) including all fitting, heads, shoes, bends and removing from sites complete all as specified and directed. (Measured over all as fixed along the centre line over the fittings and accessories)
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
S&F 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed.
S&F in repairs PVC (SWR) floor trap 75mm, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs grating square / round 150mm size of PTMT with centre hole movable or side hole for fix to waste pipe (mimimum weight 100 gms) complete all as specified and directed.
S&F PVC (SWR) reducers 75/110mm bore complete all as specified and directed.
M&L for cement concrete M-10 (Nominal Mix) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel and drain complete all as specified and directed.
Extra for fair finishes drain or channel 30cm and over in girth in cement concrete using extra cement including forming mounds metred /stopped ends etc complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in floors / pavings complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment coloured, reflective type of approved quality laid over and including 25mm thick sand cushioning vibrated with mechanical vibrator complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternative bays n. exc 2M in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and n. exc 1.5m deep and getting out in any type of soil complete all as specified and directed.
Demolition and bracking up drain pipe SWG line set in CM of description, 100mm dia including side packing / haunching complete all as specified and directed.`
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) for bed concrete to drain pipe packing under hunching for sides for 150mm dia SWG pipe lines complete all as specified and directed.
M&L for SWG drain pipe grade 'A' 150mm dia laid in trenches incl jointing in CM 1:3 complete all as specified and directed.
Returning and filling in approved earth including levelling spreading watering and well ramming in any layers n. exc 25cm thick complete all as specified and directed.
Removing excavated materials n. exc 100m and depositing where directed and complete all as specified and directed.
Dismatling stone slab of any description laid, bedded and pointed in any mortar in floors complete all as specified and directed.
S&F in repair new rigid PVC waste pipe of approved quality 32mm bore, 75mm long with one end socketed fixed to waste coupling including one PVC reducer 32mm complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint over a coat or red oxide primer complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise descriped over 10cm width girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation including removal of existing old wall surfaces and appling two coats of oil bound distemper over a coat of 1mm thick average thick wall putty, complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and apply two coats of oil bound distemper over a coat of 1mm thick wall putty, complete all as specified and directed.
M&L for two coat of white washing to old ceiling surfaces including preparation of surfaces complete all as specified and directed.
M&L for two coats of white wash on newly plastered ceiling surfaces including preparation complete all as specified and directed.
M&L for two coats of white washing on newly plastered wall surfaces including preparation of surfaces complete all as specified and directed.
M&L for two coats of cement base paint over old wall surface including preparation of surfaces complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coat of cement base paint over a coat of primer, complete all as specified and directed.
Taking down existing tar felt or of any description including cement plaster or concrete of any thickness from the roof surfaces of building including cleaning the surfaces in all respect & preparing it for further treatment & removing rubbish from site complete all as specified and directed.
Material and labour for 40mm thick (avergae consolidated thickness) PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate) laid in slope as in padding, finished even and smooth on existing slope including provision of 'V' shaped groove 6mm wide and 10mm deep at 1.20 metre interval or parts thereof, both ways on top of PCC padding and filled with mastic bitumen of (1:1) proportion complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of RCC/ stone patti roof surfaces finished even & smooth without using extra cement complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in leveling course / and similar works etc complete all as specified and directed.
M&L for cutting out cracks to 'V' section in existing roofs or terracing, cleaning out and filling solidly with hot mixture of bitumen and clean dry sand 1:1 (by weight ) complete all as specified and directed.
M&L for five layered roof treatment with APP modified polymeric water proofing membrane, 2mm thick having centre core not less than 100 micron high molecular high density polyethylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3 Kg /Sqm applied with bonding material using blown type bitumen grade 85/25 @ 1.20 Kg/Sqm over bitumen primer conforming to IS – 3384 @ 0.40 Kg /Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg sqm over APP membrane with all overlaps complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from site and making good disturbed surface of walls, floors etc.
Taking down MCB DB's complete with MCB's/ Isolator etc removing materials from site and making good disturbed surface of walls, floors etc.
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for:- Make of wire- Polycab/ KEI/ Havells Make of PVC conduit - Polycab/ Finolex/Legrand-MDS
One light point/ bell point controlled by one, one way switch.
One ceiling fan/ exhaust fan point controlled by one, one way switch.
One three pin 5 Amp socket on same board with other switches.
One 3 pin 5 Amp socket on independent board.
Ditto all as per item No. 121.04 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth. Make of wire- Polycab/KEI/Havells Make of PVC conduit - Polycab/ Finolex/Legrand-MDS
S&F switch piano flush type 5 amps, single pole one way 240 volts. MAKE:- Havells/ SSK/CONA
S&F switch piano flush type 15 amps, single pole one way 240 volts. MAKE:- Havells/ SSK/CONA
S&F Socket outlet 3 Pin 5/6 Amp flush type. MAKE:- Havells/ SSK/CONA
S&F socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type ISI marked complete. MAKE:- Havells/ SSK/CONA
S&F ceiling fan regulator electronic flush , steped (four step) 230 Volts AC MAKE:- Havells/ SSK/CONA
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm. MAKE:- Havells/ SSK/CONA
S&F lamp holder PVC/polycarbonate type with back plate complete all as specified and directed. MAKE:- Havells/ SSK/CONA
S&F LED tube light fitting in acrylic linear tube (1x 18 watt), 230V for single LED tube light including 1 x 18 W LED retrofit bar professional CW 6500 K cover channel, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. Make: Bajaj Cat Part No BLRB 18W CWc for tube , BLRB - DB 118 for batten, Havells Cat part No PHOTONULTRA1213T8LLSSTL18WLED865SPC (for tube) REGALBATTENT8UPTO1X18WDSBSWH (for batten), Surya Cat no. SLETL-DS 18 PC REFORM for tube, SUB1 18T8LED for batten
S&F LED bulk head luminaire 1x 10 W bulk, IP 65 protection complete with all accessories and including connecting up with three core copper conductor cable complete all as specified and directed. Make: Jaquar Cat part No LBLK01X010XCor equivalent make of /Crompton/ Havells
Supply and fixing testing and commissioning energy saving street light luminaire 15 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete with individual LED lences and complete all as specified and directed.
Supply and fixing street light bracket made of 32 mm GI pipe, 1.2 mtr lenght fixed with two nos of clamp, nut and bolts complete all as specified and directed.
Taking down existing ceiling fan, dismantling blades and refixing after cleaning incl conecting up with three core flexible cable from ceiling rose to fan.
S&F of MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB's complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S&F MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. Make: Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S&F MCB SPN, 240 volt, 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. Make: Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing.
Supply, laying and testing XLPE insulated heavy duty electric cable with aluminium stranded conductor 1100 volts grade,10 Sq mm nominal cross section area 2 core complete all as specified and directed. .
M&L for filling clean and dry sand cushioning for cable in trenches all as specified and directed. Note: Punned thickness shall be measured & paid.
Supply and laying of bricks old class ‘B’ as protect on to UG cable laid flat adjoining to each other width wise all as specified.
Supply and fixing light grade GI tubing 40 mm dia with all fitting laid under road/floor or fixed on pole for cable protection .
Supply and fixing tubes medium grade GI tubing 40 mm dia with all fitting fixed on walls/ ceiling for hanging of ceiling fan.
Supply and fixing of hook made of anodised flat iron for hanging of ceiling fan suitable for GI pipe 40 mm dia complete with nut, bolts .
S&F in repair down rod for ceiling fan made out of 15 mm dia GI pipe or hard conduit pipe complete with shackle assy with rubber reel , nut, bolts etc. of reqd length as per site complete all as specified and directed.
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
SHREE BALAJI TRADING CORPORATION
kirtiman traders
Pioneer Enterprises
M/S Nexus Projects
M/s SUNIL ENTERPRISES
M/s Jai Jinendra Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .