Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.5 LAccepted-AOC B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L1 | Accepted-AOC L1 | |
| 2 | L2₹80.6 L+₹6.4 L (8.64%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹89.1 L+₹14.9 L (20.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹90.2 L+₹16.0 L (21.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
13 Feb 2021, 6:00 pmClosed
CWE No 2
CWE No 2 Delhi Cantt
SPL REPAIRS TO BLDG NO P-1 AND P-2 (S/L OFFRS ACCN) AT BASE HOSPITAL UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2020_MES_401803_2
CWE/BH-14/2020-21
Open Tender
Civil Works - Others
Item Rate
240 days
Base Hospital Delhi Cantt
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE (E/M) BASE HOSPITAL
₹1.6 L
Yes
8 Mar 2021
12 Jan 2021
15 Feb 2021
12 Jan 2021
13 Feb 2021
1 Feb 2021
Amount
Demolition of brick work built in cement mortar of any description and including disposal of all debris exceeding 1.5 Km but not exceeding 5 Km and complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Dismantling brick tiles or terracing tiles, single layer on roof laid over mud pushaka and pointing with cement mortar complete all as specifed & directed.
Demolition of Mud in roofs, any thickness, including PCC/plastering and leeping complete includingremoval of demolished mud/debris etc complete exceeding 1.5 Km but not exc 5 Km and complete complete all as specifed & directed.
M&L for providing plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in roof padding, water staging, roof kerbs , etc including rounding & chemfering the edges, cleaning the surface by wire brushing complete all as specified and directed.
M&L for 10 mm thick rendering on concrete surface on roof with cement mortar 1:4 finished even and fair including mixing of water proofing compound @ 3% by weight of cement or as per manufacturers instruction complete all as specified and directed. (Note : Water proofing compound shall be measured and paid separately)
Supply only water proofing compound (powder) complete all as specifed & directed.
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and applying a coat of cold applied bitumen based primer 85/25 on entire surface @ 0.30 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight not less than 3.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end over laps & 10 cm side over laps etc as per manufacturers instruction. (c) M&L for finishing of top surface by two coats of aluminium paint complete all as specified and directed.
Dismantling AC corrugated/semi-corrugated sheets in roof coverings including ridges etc complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.5 0mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of reinforcement cement concrete of any description & in any position including cutting of reinforcement & disposal of all debris out side MoD land complete all as specified and directed.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A-1 using 20mm graded crushed stone aggregate as in chajjas complete all as specified. Note : Reinforcement and form work will be measured and paid separately.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A1 using 20mm graded crushed stone aggregate as in foundation/ footing, plinth beam, bases for column beam complete all as specified and as directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L for TMT steel bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips etc complete.
All as per item No.16.00 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders.
Demolition of cement concrete in ground floors and paving not exc 15cm thickness (below or above ground level) including disposal of all debris exceeding 1.5 Km but not exceeding 5 Km complete all as specified and directed
M&L for PCC 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in sub base, foundation, filling & mass concrete complete all as specified and directed.
Supply and laying sand cushioning 25 mm thickness for laying of interlocking paver block complete all as specified and directed.
M&L for vibrator compacted rubber/glass moulded precast concrete interlocking paver block shape, size and colour as approved, confirming to IS 15658-2006 of 60 mm thickness M-35 Grade, using grey cement and with pigment complete all as specified and directed.
M&L for heavy duty coloured (approved colour) fully vitrified paving tiles of size 300mmx300mmx10-12mm thick, set and jointed in neat cement slurry and pointed in coloured or white cement to match the shade of tiles over and including 15 mm thick screed in CM 1:6 complete all as specified and directed . Make: Somany (Durastone)/Marbito (M stone)/ Riwasa( Parkland series) / Johnson (Endura)/ Nitco(Kratos)
M&L for 75 mm PCC 1:3:6 type C-2 (40mm graded agg) as in plinth protection/hard standing, laid in pannels including filling the joints by using sand & bitumen mixed in ratio 1:1 and finished the surface even and smooth without using extra cement complete all as specified and directed.
Demolition of stone slabs laid bedded and pointed in any mortar and cladding tiles of any description or thickness in floors, aprons, walls, etc and removing the debris off MOD land complete all as specified and directed.
M&L for 20 - 25 mm thick machine cut kota stone flooring laid over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4, jointed and pointed with grey cement slurry mixed with pigments to match the shade including rubbing and polishing upto mirror finished (polishing) image complete all as specified and directed.
M&L machine cut kota stone slab 20-25mm thick in treads & riser in one piece (length will be as per the width of staircase) laid over and including screed bed or bedding layer mortar 15mm thick in cement mortar 1:4, jointed and pointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and mirror finished polishing complete all as specified and directed.
M&L for 18-20mm thick of approved shade granite stone (superior Quality) slab (table rubbed and polished as in floors, jambs, steps, cooking platform etc and the like, over & including 15 mm thick screed in cement mortar 1:4, pointed in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including two strip of line make on (tread of stair case) granite complete all as specified and directed.
M&L for 10-12mm thick Zed black granite stone(superior Quality) slab of (table rubbed and polished) as in wall lining (venering to wall) and the like, over & including 10 mm thick plastering in cement mortar 1:3 including pointed in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and including disposal of all debris outside MoD land complete all as specified and directed.
M&L for vitrified ceramic tiles light shade, double charged Ist quality 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over & including 15mm thick screed bed or bedding layer in cement mortar (1:4 ) complete all as specified and directed.
All as per item No.30 here-in-before but on vertical surfaces over and including 10 mm thick plaster in cement mortar 1:4 complete all as specified and as directed.
M&L for 7mm to 8mm thick Ist quality ceramic non skid tiles coloured of area exceeding 0.11 sqm but not exceeding 0.18 Sqm (400x400mm) in flooring set and jointed in neat cement slurry and pointed in coloured cement to match with tiles laid on 15mm thick cement screed (1:4) complete all as specified and directed.
M&L for digital coloured glazed ceramic tiles of 400 x 300 x 7mm thick and 600 x300mm size 7mm thick in vertical surfaces (including designed borders ) such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match over rendering 10 mm thick on fair faces of brick work in cement (1:4) complete all as specified and directed. Note:- (Rate of Designer border in vertical surface will be deemed into quoted rates)
Taking down cement plaster of any description on brick or stone walls etc. including raking out of joints, hacking for key, scrubbing down with water etc. including removal of debris out side MoD land complete all as specifed & directed.
M&L for 10 mm thick cement plastering in cement mortar 1:3, on ceiling surfaces and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4, mixed with 3% water proofing compound on brick or concrete external surfaces of walls, finished the surface fair and even without using extra cement complete all as specifed & directed. Note: WPC will be measured & paid separately.
M&L for 15mm thick rendering in cement mortar 1:6, on brick or concrete internal surfaces of walls finished the surface fair and even without using extra cement complete all as specifed & directed.
M&L for prepration of new plastered ceiling surface & applying 2 to 3 mm thick wall care putty followed by a priming paint & two coats of plastic emulsion interior grade paint (Asian Paints Royal Luxury Emulsion) of approved tint complete all as specified and directed. (Note : The work should be executed by skilled applicators approved by the manufacturing company).
M & L for preparation of new plastered surfaces of walls and applying two coats of apex white/red/any colour as approved (weather proof) over one coat of priming paint complete all as specified and directed.
M&L for prepration of new plastered or concrete wall surface & applying 2 to 3 mm thick wall care putty & sand papering etc followed by a coat of alkali resistant primer & two coats of plastic emulsion interior gde paint (Asian Paints Royal Luxury Emulsion) of approved tint complete all as specified and directed. (Note : The work should be executed by skilled applicators approved by the manufacturing company).
M&L for complete removal of existing treatment from old decorated wall surface by scrapping, sand papering etc to prepare an even surface and applying a coat of primer paint followed by two coats of apex white/red/any colour (weather proof) complete all as directed.
M&L for preparation of old painted steel surface of any description over 10cm in width or girth & applying one coat of red oxide primer & two coats of synthetic enamel paint complete all as specified & directed.
M&L for complete removal of existing treatment from old decorated wall /ceiling surface by scrapping / washing & applying 2 to 3 mm thick cement wall care putty of make Birla/ Asian, making the surface smooth bysand papering/ rubbing the surface complete followed by a coat of primer with alkali resistant primer paint and two coats of oil bound distemper comlete all as specified and directed.
S&F in repair brass, glossy finish towel rail Cat No.BA-03 of Prayag/Equivqlent of ZIM/ESSCO compete all as specified and directed .
M&L for preventive treatment against the danger of carbonation in exposed faces of RCC members:- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil grease etc .by vigorous wire brushing including light grill blasting where necessary recommended by Engr in charge.(ii) Further cleaning using biocide (as recommended by manufacturer) to ensure that surface algae and fangus and no trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine, after application primer shall be allowed to dry for 03 hrs or as directed. (v) Apply a coat of neat aliphatic acrylic anti corbonation (ACC) over the primed surface with air/spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufaturer. (vi) Apply a more coat of aliphal anti corbonation (ACC) after 5 to 6 hrs as recommended by manufaturer complete all as specified and directed.
M&L for followings:-(i) removing plaster & finishes all around the columns, slabs & beams(on all four side of column to full height. Three side of beam to entire span & bottom of slab to area as directed) (ii) after cleaning gently removing cover concrete using pnaumatic/electric chipper or any other aprroved tool in entire portion of structural member, removal cover concrete shall be done to an extent when reinforcement is visible. (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed (concrete shall be slopped to an extent concrete substrate is exposed. (iv) Cleaning exposed concret substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved.(The Engr in charge may order sand blasting if rust is approved)(vI) Any other work as directed by Engr in charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof/anti corrosive treatment to bars (i) Cleaning of all exposed bars (new & old) around (ii) Apply a single coat of alkaline rust converting primer on alround bars new or old as recommenede by the manufacturer (iii) apply two coats of epoxy phenolic anti corrosive protective coat on bars alround new or old as recommended by the manufacturer.(Note:Anti corrosive treatment shall be continuous espcially in the regions where pitting imperfections etc where present on the surface of the bars. it is important that the rear portions of the bars (those towards the concrete substrate should not be left without coating)
M& L for providing PMM (poly modified cementitious mortar) (i) Dry sub state surface and free of debris & dust (ii) Applying epoxy bond coat on the sound substate using approved spray machine & ensuring that no pin holes are visible (in case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes) (iii) Immediately after applicaion of epoxy bond coat as above apply PMM (polymer modified cementitious mortar) of 25mm thick. Note (Application of PMM shall be prefeably be in coats of appx 10mm thickness PMM work shall be excuted in fairely rapid successions so as entire work is completed with in 30 mins) PMM shall be pre packed ready to use (iv)PMM surface to be moist cured for three days followed by air curing in temp as recommended by manufacturer complete all as specified and dircted.
M&L for Rebaring of new reinforcement bars for structural connections in RCC columns including power drilling holes of appropriate diameters in reinforced or plain cement concrete upto standard depth or as per specification of manufactureres, fixing the reinforcement in position using epoxy (Hilti RE-500 or Equivalent ) at all height and level.(Rate shall include cost of labours, T &P for power drilling in concrete complete. including cleaning the drilled holes and loose dust by blowing air. (Note : Reinforcement measured seperatly item No-
Shear connector 08mm dia *100mm using Hilti Re-500
12 mm dia*120mm Rebaring using Hilti-Re-500
20 mm dia*200mm Rebaring using Hilti-Re-500
M&L for washed stone grit plaster on exterior walls in two layers, under layers 12 mm thick cement plaster 1:4 (1 cement :4 coarse sand) following the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer with 15 mm thick cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand:2 coloured marble stone chipping 10mm nominal size) including using Colour pigment & marble powder as required in ground in panels with groove all around as per approved pattern including scrubbing and washing the top layer with wire brushes and water to expose the stone chippings complete all as specified and as directed.
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and as directed.
Cutting grooves 75 mm wide & 65 mm deep in brick wall/ RCC surfaces at any location, shaping horizontal face with mechanical cutter and grooves filled with PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) mixed with chemical compound SUPER LATEX OR DR FIXIT OF PIDILITE INDUSTRIES LTD or SBR LATEX of STP LTD mixed with proportion 200 ml per 50 Kg cement as per manufactures instruction complete all as specified & as directed.
Taking down chowkhat or frames (without taking off shutter from the frame) not exceeding 1.50 sqm each complete all as specified and directed.
All as per item No.53.00 here-in-before but exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and directed.
M&L for framed work as in doors, chowkhats or gates of angle or other section with gusset plates, rails, braces,and hold fast etc., complete all as specified and directed.(Fe 290 gde E-165)
S&F solid PVC moulded door frame of size, 50x47mm, made out of 5mm thick of any colour PVC sheet, reinforced with MS square tube fixed with screw/plugs to brick walls complete all as specified and directed.
S&F Factory made Factory Made Solid PVC Moulded Door Shutter 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed.
M&L for 35 mm thick, 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F aluminium anodised powder coated various section as required for door/ window/ ventilators etc including fixing and making the frames hinges to receive glass/wire gauge etc. with one or more rebates / sliding complete including all required fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (3 No for Door/2 Nos for window) suitable handle (1 No.), aluminium tower bolt 150/125mm long 2 No in each leaf, rubber beading, clips locking arrangement for shutter, sealant etc all as specified and as directed by Engr- in- charge. Note:-(i) Quoted rates includes for all required fittings such as rubber neoprene packing, screws, roller, handles, hinges , tower bolts, hook & eye etc. (ii) Aluminium door/window/ ventilators to be fixed with cadmium plated screw not less then 300 mm c/c & cealing the joints between frames & granite/kota stone with polysulphide sealant as per the manufactures instruction". (ii) Window AC will be fixed in certain windows so necessary frame will be required for fixing of window AC and that window will be openable.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples or powder coated aluminium beading complete all as specified and directed.
S&F kitchen cabinet 45-50 mm deep using 18/19mm thick PVC foam sheet of best quality prelam one side all around, partiation & in shutter with & including hinges, mild steel, bright finish or electrogalvanised (Suitable for 18 mm thick shutters), magnetic catches, knob 50mm dia, polished, hard wood , sliders & any other fitting required etc complete fixed with dash through fastner screws to opening/wall complete all as specified and directed. Make: Rajshree/Sintex
S&F 300 mm long stainless steel sliding door bolt, stove enamelled black with bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts four on bolt plate and two on stapple plate complete all as specified and directed.
S&F 200 mm long Aluminum anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long Aluminum handles, cast type anodised complete all as specified and directed.
S&F 100mm long stainless steel butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 140mm long floor door stopper of Aluminum alloy body and tongue, anodised with hand drawn steel spring fixed in floor.
M&L cutting holes in brick walls (exc half brick but not exc one brick from the face of jamb into the wall) built in cement mortar for inserting hold fast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as required complete all as specified and as directed.
S&F PVC coated 25mm dia mild steel curtain rod of medium weight including fixing brackets, curtain ring @ 7 nos/Rm and decorative end supports etc complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing and connections & all fittings such as bib taps, stop cock etc including cleaning for refixing or removal to store complete all as specified and as directed.
Supply and fixing 20 mm nominal outer dia (for intenal and concealed work) chlorinated polyvinyl Chroride (CPVC) SDR 13.5 pipe having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, including fixing the pipewith clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joint complete as per direction of Engr-in-Charge
Taking up or down 20 mm bore steel water tubing and connections & all fittings such as bib tap, stop cock etc including cleaning or refixing or removal to store
Supply and fixing 25 mm nominal outer dia (for external work) chlorinated polyvinyl Chroride (CPVC) SDR 13.5 pipe having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, including fixing the pipewith clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joint complete as per direction of Engr-in-Charge
S&F in repair 20 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.
Dismantling of water tanks exceeding 500 ltrs but not exceeding 1000 ltrs capacity and removing to store complete all as specified and as directed.
S&F PVC water storage tanks of 1000 ltrs capacity rotational moulded (multi layered, cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
S&F ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of 20mm dia complete all as specified and as directed.
Taking down/Dismantling eaves gutter, rainwater pipes and CI soil,PVC (any type) including all fittings heads, shoes, bends, swan necks etc including cleaning for refixing or removal to store.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls using PVC clamp suitable for 110mm bore PVC (SWR) pipe complete all as specified and as directed.
S&F PVC (SWR) bends 110mm bore any radius with access door including jointing with solvent cement complete all as specified and as directed.
S&F PVC (SWR) single T equal or unequal with access door 110mm dia with rubber ring joint and fixed to walls complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joint and fixed to walls using PVC clamps complete all as specified and directed.
S&F PVC (SWR) single T with access door 75 mm dia with rubber ring joint and fixed to walls complete all as specified and directed.
S&F 75mm dia PVC (SWR) bends with access door any radius, with rubber ring joint and fixed to walls complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm dia with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) size in 75mm square multi floor trap incl grating with anti mosquitoes filter complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110mm,setting and jointing with solvent cement complete all as specified and directed.(Make-Prayog ,Supreme or Astal
S&F MS framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed stoneware) set in cement mortar 300 mm internal dia of pipe complete all as specified and directed.
S & F Reinforced concrete pipes,class NP2 laid and jointed complete with collars ware drain pipes laid in trenches and jointed internal dia of pipe 300 mm complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C2 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes 300mm dia including packing under and haunching against the sides of pipes sfter they are laid and tested all as specified and as directed.
Cutting into existing manholes for connecting new mains pipe making good to pipes rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finish and reforming benching as required, internal dia of pipe 300 mm dia complete all as specified and directed.
M&L for Providing precast cement concrete louvres and jallies type B-0, 1:2:4 using 12.5 mm graded stone aggregate and set in cement mortar 1:6, 35mm thick (measured solid), including all mouldings but excluding frame and applying two coats of white wash with & including demolition of old RCC zali & removal of debris out side MoD land complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1, (using 20mm graded crushed stone aggregate) as in surface channels and drains including necessary form work etc complete all as specified and as directed.
Extra for forming fair finishing drain or channels 30 cm inner girth in cement concrete using extra cement including forms, moulds stopped ends etc.
S&F as in repair sink with drainage board made of 1mm thick stainless steel, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F as in repair Wash down water closet (Pedestal pattern) using vitreous China squatting pan of pattern “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern ), complete with & including Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern, Plastic water closet seat, white, recessed bottom pattern and cover and mild steel chromium plated or aluminised hinging device,PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handleincluding brackets etc complete
S & F in repair WHB counter top oval shape white / ivery coloured of size 560 x 410mm make- CNS-Ivy-WB07 of Jaquar or Equvlent complete all as specified and directed. (CNS-Ivy-WB07 of Jaquar or Equvlent complete all as specified and directed.)
S&F 15 mm bore as CP Bib cock long nose with flange, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. (Make : Prayag, Cat No. 8706/Equivqlent of ZIM/ESSCO)
S&F 15 mm bore CP angle cock with flange, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. (Make : Prayag, Cat No. 8710/Equivqlent of Jaquar)
S&F 15 mm bore CP 2-way angle cock with flange, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. (Make : Prayag, Cat No. 8711/Equivqlent of Jaquar)
S&F 15 mm bore CP centre hole basin mixer W/o pop up, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. (Make : Prayag, Cat No. 8750/Equivqlent of Jaquar)
S&F 15 mm bore CP wall mixer 3-in-1 (with provision for OHS & Hand shower both), screwed for iron pipe or for brass ferrule and fixed. (Make : Prayag, Cat No. 8780/Equivqlent of Jaquar)
S&F CP over head shower with arm & flange , etc complete all as specified and directed. (Make : Prayag , Cat No. BS-76/Equivqlent of Jaquar)
S&F CP Handshower with 1.5 mtr flexible tube and hook complete all as specified and directed. (Make : Prayag , Cat No. BH-76/Equivqlent of Jaquar)
S&F CP waste coupling heavy full thread 32 mm complete all as specified and directed. (Make : Prayag , Cat No. BEA-15/Equivqlent of Jaquar)
S&F CP toilet paper holder compete all as specified and directed (Make : Prayag, Cat No.BA-98/Equivqlent of Jaquar).
S&F CP soap dish compete all as specified and directed (Make : Prayag, Cat No.BA-55/Equivqlent of Jaquar).
S&F CP health faucet with 1 mtr tube and hook compete all as specified and directed (Make : Prayag, Cat No.BEA-41/Equivqlent of Jaquar).
S&F for PVC connection 15 mm bore with brass nuts and 450 mm long and fixed compete all as specified and directed. (Make : Prayag, Cat No.BCT-03/Equivqlent of Jaquar)
S&F corner glass shelf 300 mm with ABS brackets complete all as specified and directed. (Make : Prayag , Cat No. BEA-46/ Equivqlent of Jaquar)
S&F as in repair for Looking mirror 600 x 450 mm compete all as specified and directed (Make : Prayag, Cat No.553/Equivqlent of Jaquar).
S&F as in repair for Mirror cabinet 350 x 450 mm compete all as specified and directed (Make : Prayag, Cat No.551/Equivqlent of Jaquar).
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning and filling in soil incl levelling, watering and well rammingin layers not exceeding 25cm complete all as specified and as directed.
Removing excavated soil including disposal of all debris exceeding 1.5 Km but not exceeding 5 Km outside of MOD land complete all as specifed & directed.
M&L for treating of soil under existing floors using emulsion @ one ltr per hole, 300mm apart including drilling and plugging 12mm dia,holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
M&L for providing and injecting chemical emulsion for post construction antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate 7.5 ltrs per sqm of the vertical surface of the substructure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified and as directed.
Impregnating cream for injection into masonry or concrete wall 230mm thick against capilary rising humidity.Rising bar super strong (Product No 201) of chowgale building chemicals or equivalant Pidilite/Drfixit/Sika/Fosroc complete all as specified and directed. Method of Application (a) The surface must be sound,absorbent,clean,free of dust,oil,paint,curing agents,loose cement or lime plaster & concrete debris or any seperation layers. (b) The plaster must be knocked off at least 50 cm beyond the visibility penetrated area. (c) Damaged mortar joints are to be scraped out to a depth of appx 2 to 3 cm. all sharp edges/joints needs to be levelled,loose concrete to be removed. (d) Drill bore holes at ground level horizontally.The bore holes are drilled horizontal into the masonry. (e) The holes should be drilled until a depth of Appx 5 cm (for a 6 cm thick wall) before the end of the wall is reached.The bore holes should have a diameter of 12mm upto a maximum of 15mm and shoul be spaced appx 100 to 120mm apart and vertical offset is 6 cm Max. (f) Before inserting rising bar super strong or equivalent the bore holes must be cleaned from boring dust by using air presuure,it is not necessary to pre wet the bore holes. (g) For applying of Rising Bar super strong or equivalant the dosing system inserted as far as possible into the borehole.While dosing the product uniformly,the injection nozzle is pulled out leading to a completely filled bore hole.. (h) Treatment of highly absorbent masonry might require repealed filling of the borehole.Depending upon extent of damage,Rising bar super strong or equivalent can be re injected into the same hole after 24 hrs.Depending on abosrbency,apllication or masonry thickness 0.1 to 0.15 litre/m with 10 cm wall thickness.
Use & waste Formwork to soffits of Chajjas, chullah hood troughs and similar items including edges (Horizontal or sloping) rough finished flat surface of concrete complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, plinth beams, footings, base of columns, pile caps and similar work, vertical or to batter, for rough finished surfaces complete all as specified and as directed.
M & L for taking down loose concrete from RCC column, beam, slab & the like, roughening & cleaning concrete surface with steel wire brush, de-rusting the corroded reinforcement by using antirust chemical of fosroc or equivalent & guniting (sprayed concrete) on damaged RCC surfaces of columns, slabs, beams etc, minimum thickness 60 mm, with concrete mix 1:1.2:2.4 (1 cement : 1.2 well graded coarse sand confirming to zone II : 2.4 well graded coarse aggregate 8 mm down retained on 2.36 mm sieve) added with fibrillated Polypropene Fibres (125 gm per bag of cement) and chemical admixer (Polymer Monobond 5% of weight of cement) including high tensile welded wire mesh of 5 mm dia @ 50 mm spacing properly anchored with adjoining surfaces, including finishing the top surface fair & even by applying 5mm thick cement plaster in cement mortar 1:3 complete all as specified and as directed.
S&F 2nd class HW factory made, kiln seasoned pressure treated door gauged & skeleton shutter 35 mm thick open rebated & prepared to receive glass, gauge etc, without sash bar, fitted with cut & mitred beads, for securing glass/ gauze etc. Size of shutter members as specified in SSR part-I sec-8.2(a); supplied and fitted to chowkats
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wood surfaces width or girth exc 10cm including preperation of surfaces complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces width or girth exc 10cm including preperation of surfaces complete all as specified and directed.
All as per item No 125.00 here-in-before but on old steel surfaces.
M&L plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
M&L Pre-cast reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as spd. Note: Reinforcement will be measured & paid separately
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in hard and dense soil returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
S&F 4 mm thick pin headed type ordinary quality in square, area of each pane not exceeding 0.50 sqm each fixed to aluminium window frame complete all as specified and as directed.
S&F sheet tinted glass 4mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S&F Sheet tinted glass 4.8 mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S&F powder coated aluminium grill with and including suitable aluminium anodised frame F/H section as requird as per design No DG- 104 or equivatent 7.5 mm thick all as specified and as directed.
S&F Steel work in tubular trusses,pulin, vertical posts, rafter,angle cleats, plates including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 including one shop coat of zinc chromate primer paint (including preparation o fsurface) at Contractor’s workshop before fabrication not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S&F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete
S&F mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
M&L point wiring for modular switches with 1.5 sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, drawn into and including concealed, rigid non-metallic PVC conduit of minimum 25mm dia or as per site requirement with all fittings, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light point controlled by one switch 6 Amps, one way single pole complete all as specified and directed. Note - The Quoted rates including cutting, chasing & making good after fixing of PVC conduit.
All as per item No. 139.00 here-in-before but one light point controlled by 2-way switch 5 Amps .
All as per item No. 139.00 here-in-before but one fan point controlled by one switch 5 Amps one way single pole.
All as per item No. 139.00 here-in-before but one three pin 5 Amps socket out let on independent board.
All as per item No. 139.00 here-in-before but one three pin 5 Amps socket out let on same board.
All as per item No. 139.00 here-in-before but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 1.5 Sqmm size of earth conductor complete all as specified and directed.
All as per item No. 139.00 here-in-before but one bell point controlled by one bell push independent.
S & F ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , one way 10 Amps complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , two way 6 Amps complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , one way 15 amps complete all as specified and directed.
S&F in repair Modular socket outlet 3 pin and 2 pin , 10 amps , flush type complete all as specified and directed.
S&F in repair Modular socket outlet 2-in-1, 3 pin, 10 and 20 amps , flush type complete all as specified and directed.
S&F in repair electronic fan regulator (5 Step up type) 280 Volts suitable for ceiling fan complete all as specified and directed.
S&F in repair Bell push flush type 5 Amps complete all as specified and directed.
S&F in repair Bell AC 230 Volts Single pole complete all as specified and directed.
Supply and fix single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
M&L for sub main wiring with 2 runs of 4 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade as per ISS and one run of 4 sqmm size PVC insulated copper conductor complete all as specified and directed.(Note. Two run of cable and earth conductor shall be measured as one length) Note - The Quoted rates including cutting, chasing & making good after fixing of PVC conduit
M&L in repair for sub main wiring with 2 runs of 6 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade as per ISS and one run of 6 sqmm size PVC insulated copper conductor complete all as specified and directed.(Note. Two run of cable and earth conductor shall be measured as one length) .Note - The Quoted rates including cutting, chasing & making good after fixing of PVC conduit
S & F in repair for distribution board double door type, TPN, vertical, 4 way, complete suitable for accomodating upto 160 Amps MCCBwith incomming frame three pole , including bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F in repair for distribution board double door type, TPN, vertical, 8 way, complete suitable for accomodating upto 250 Amps MCCBwith incomming frame three pole , including bus bar, neutral link, blanking plates etc complete all as specified and directed.
M&L for sheet metal enclosure double door DB SPN for distribution 8 way with 200 A, rated busbar for distribution complete all as specified.
M&L for sheet metal enclosure double door DB SPN for distribution 12 way with 200 A, rated busbar for distribution complete all as specified.
S & F in repair MCCB 415 V, 125 Amps, 25 KA, 3 Pole complete all as specified and directed. Make - Havells/Legrend/Crabtree
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as directed. Note:- The unit rate quoted shall be include for necessary excavation and earth work , earth strip connected to test point max 7 mtr as per site requirement, PCC 1:3:6 type for earth pit & Pit cover, funnel with wire mesh including GI medium grade watering pipe 15mm bore & 40 mm dia for supporting of earth strip/wire.
S&F white, modular cover plate with frame , 2 module conplete all as specified and as directed.
S&F white, modular cover plate with frame , 3 module conplete all as specified and as directed.
S&F white, modular cover plate with frame , 4 module conplete all as specified and as directed.
S&F white, modular cover plate with frame , 6 module conplete all as specified and as directed.
S&F white, modular cover plate with frame , 8 module conplete all as specified and as directed.
S&F in repair rusted sunken box by modular metal flush board 2 module complete all as specified and as directed.
S&F in repair rusted sunken box by modular metal flush board 3 module complete all as specified and as directed.
S&F in repair rusted sunken box by modular metal flush board 4 module complete all as specified and as directed.
S&F in repair rusted sunken box by modular metal flush board 6 module complete all as specified and as directed.
S&F in repair rusted sunken box by modular metal flush board 8 module complete all as specified and as directed.
S & F decorative Wall Light suitable for accomodatindg upto 10 watt LED bulb. Make- Havels product code LHFOECE1TZ1O014 or eqivalent in Philips/Anchor
S & F in replacement for existing 36/40 Watt tube light fiiting by energy efficient LED light fitting 18/20 Watt,230 Volt of 1200 mm + 50 mm length along with fixture, heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed.
S & F in replacement for existing 18/20 Watt tube light fiiting by energy efficient LED light fitting 9 Watt,230 Volt of 600 mm + 60 mm length 6000 K colour temp ,decorative ultra slim linear LED lighting fixture with extruded Al. heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed.
S&F in repair Bldg security light fitting LED 45 Watt cast aluminium housing, toughened glass,silicon gaskect, high power LED with lens for uniform istribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including GI bracket 1.5 Mtr with clamps and bolts complete all as specified and directed. Make - Havells Cat pt no- LHETAXU7PN6J045 or equivalent in Goldwyn/CG/Luster
S&F Crown LED 15W LED 6000K surface decorative wall/ ceiling mounted LED fixture with electronic driver suitable for indoor applications. Make: Havells cat pt no. LHEOFJP7CUZ1W012/ CG/Philips
S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S& F Ceiling fan 1200 mm sweep, 240 Volt , connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to ceiling fan including nut bolt and washers of suitable size complete all as specified and directed. Note :- Old unserveciable ceiling fan will be deposited to MES store yard.
S& F exhaust fan 250 mm dia sweep, 240 Volt PVC exhaust fan with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed.
S& F exhaust fan 300 mm dia sweep, 900 RPM, 240 Volt heavy duty exhaust fan with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed. Note :- Old unserveciable exhaust fan will be deposited to MES store yard.
M & L for making hole in the existing toilet wall of stone / brick for fixing of upto 300 mm Metallic/PVC body exhaust fan and after fixing the fan making the surface good by PCC work & plastering with paintng as per existing colour shade as directed and specified by Engineer in charge.
S&F in replacement after taking down existing Water heater with new geyser of capacity 25 Ltr AC Single Phase 240 Volts, 2 KW including plumbing works, elect connection ,geyser mounting nut and bolts fastners on wall properly complete all as specified and directed.Make : Havells/Crompton Greaves Note :- Old unserveciable geyzers will be deposited to MES store yard.
LED bulbs retrofit pin type 10W, 240 V AC- 50 Hz.
S & F in repair MCB SPN, 240 Volts, 40 Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 6-32 Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 63 Amps complete all as specified and directed.
S & F AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, basis current 10 A, Max continuous current 600% of basis current conforming to IS-13779 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in Cyantech Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry including Transparent Polycarbonate meter boxes for single phase energy meter and required lenth of 6 Sqmm single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade wire for connection into circuit. all as specified and directed by Engr-in- charge.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. & cutting chases for concealed water tubing or concealed conduit wiring, etc & making good, cutting not exc 10 cm girth ll as specified and directed by Engr-in- charge.
M&L in repair for sub main wiring with 4 runs of 10 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade as per ISS and one run of 10 sqmm size earth wire PVC insulated copper conductor complete all as specified and directed.(Note four runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 40 mm PVC conduit medium grade will be measured as one unit).Note - The Quoted rates including cutting, chasing & making good after fixing of PVC Conduit .
M & L submain wiring using two run PVC insulated FRLS Copper conductor 10 sqmm with rigid non metalic PVC conduit of size 32 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 10 Sq mm etc.Note four runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit. Note - The Quoted rates including cutting, chasing & making good after fixing of PVC Conduit .
V r traders
Bhasin Construction Co
POONAM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .