| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.6 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹2.9 L+₹28,705 (10.8%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | 2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹3 L
EMD Value
₹6,000
Closing Date
24 Aug 2023, 6:00 pmClosed
AGE(I) Fatehgarh
Fatehgarh
REPAIR/MAINT TO CERTAIN B/R AND E/M WORKS IN DAD QTRS AT AVAS VIKAS COLONY FARRUKHABAD
2023_MES_609531_1
AGE(I)/FAT/ET-17 OF 2023-2024
Open Tender
Miscellaneous Works
Item Rate
90 days
AGE(I) Fatehgarh
PLEASE REFER TO TENDER DOCUMENTS
8 documents required · 8 mandatory
₹300
AGE(I) Fatehgarh
₹6,000
Yes
6 Oct 2023
21 Jul 2023
31 Aug 2023
21 Jul 2023
24 Aug 2023
5 Aug 2023
21 Jul 2023 - 4 Aug 2023
Amount
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) etc complete all as specified and directed
M& L for 40 mm thick cement concrete type B-1,1:2:4 (20mm graded aggregate as in flooring etc complete all as specified and directed
M & L for Glass dividing strips, 3 mm thick and 38mm width and inserted in position, conform to design.
Dismantling floor, hearth or wall tiling of any description, any position including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for Non - skid outdoor tiles of size 400 x 400 x 10mm thick laid over 15mm thick screed bed in CM 1:6 etc complete all as specified and directed.
S & F in repair flush kit assembly
S&F in repair Low Level Flushing Cistern PVC valveless syphonic action type, 10 ltrs capacity white, with inlet pipe connection, ball float and handle including brackets and flush pipes to squatt pattern closet including all joints and making good to the floor etc complete all as specified and directed. complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed.
M & L for preparation of old plastered surfaces of walls by rubbing down and making surface smooth and applying two coats of OBD over a coat of 3mm wall care putty complete all as directed.
M & L for preparation of old plastered surfaces of ceiling by rubbing down and making surface smooth and applying two coats of white wash complete all as directed.
S&F in repair 15mm bore Chromium plated Bib taps fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F in repair 15mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms) etc complete all as specified and directed.
Demolition and breaking up drain pipes 100 mm dia(Salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
S&F 110 mm bore PVC(SWR) pipes single sockets in any length with rubber ring joints fixed to walls or laid in floors including fixing complete all as specified and directed.
S&F 110 mm bore PVC(SWR) bend any radius complete all as specified and directed.
S&F in repair 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Taking down cement plaster of any description built in cement mortar of any description complete all as specified and directed.
M&L 5mm thick cement plastering in cm 1:3 on on ceiling surfaces even and smooth without using extra cement complete all as specified
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceilling complete.
M&L for cleaning sewage lines dia 150,200,300MM as in sewage system irrespective of there depth by Roding and other mechanical methods and removing taken out sludge out side MD land (Length of line shall be measured from manhole to manhole) all as directed by engg-in-charge (Note :- Contractor has take all the safety precautions for the employees deployed for sewage cleaning work line
S&F in repair 15 mm bore ,Stop valves angle cast copper alloy,screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated complete all as specified and directed.
S & F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms complete all as specified an directed by Engineer - in - Charge .
Taking up or down 15mm bore steel tubing and connections, including cleaning for re fixing or removal to store
Taking up or down 20mm bore steel tubing and connections, including cleaning for re fixing or removal to store
S&F Steel Tubes Medium Grade Bore of tube in 15mm galavanised with all fitting laid in walls, ceiling or laid in floors etc complete all as specified and directed.
S&F Steel Tubes Medium Grade Bore of tube in 20mm galavanised with all fitting laid in walls, ceiling or laid in floors etc complete all as specified and directed.
S&F in repair Switch Piano Flush type 6 Amp single pole one way complete all as specified and as directed.
S&F in repair Switch Socket Combination 2 in 1 flush type 6 Amp 5 Pin complete all as specified and as directed.
S&F in repair Switch Socket Combination 5 in 1, 16 Amp flush type complete all as specified and as directed.
S&Fin repair Bell Push AC 230 volts complete all as specified and as directed.
S&F in repair Call Bell Ding Dong AC 230 volts complete all as specified and as directed.
S&F in repair Electronic Fan Regulator 5 stepped type complete all as specified and directed
S&F in repair of MCB SPN 40 to 63 Amp Amp 240 volt 'C' 10 KA curve complete all as specifed and directed.
S&F in repair of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F LED Batten 4 Ft surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of > 120 lumens / W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.9, THD <20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.75 Sqmm and fixing arrangement for fixing the light fitting including marking CA No on LED fitting with permanent marker as style and size decided by eng-in-charge complete all as specified and directed.
S&F Steel body exhaust fans AC single phase 230/240 V of Size 250 mm sweep and frame with louver complete all as specifed and directed.
M/S CHAUHAN ELECTRIC WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .