Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹9.0 CrAccepted-AOC NEAR SHIV MANDIR VILLAGE RAJPURA KHARKARI TEHSIL AND DISTRICT BHIWANI 127031 | BHIWANI | HARYANA | 127031 | ₹9.0 Cr | 1st | Accepted-AOC 1st |
| 2 | 2nd₹9.8 Cr+₹78.3 L (8.67%)Rejected-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹9.8 Cr+₹78.3 L (8.67%) | 2nd | Rejected-AOC 2nd |
| 3 | 3rd₹10.0 Cr+₹95.9 L (10.6%)Rejected-AOC RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | ₹10.0 Cr+₹95.9 L (10.6%) | 3rd | Rejected-AOC 3rd |
Tender Value
₹9.4 Cr
EMD Value
₹18.8 L
Closing Date
3 Mar 2023, 3:00 pmClosed
SANJEEV KUMAR TYAGI
EE PHE Division No. 1 Hisar
Construction of RCC High Level Tank, RCC Filter Bed, RCC Clear Water Tank , C.C. Road and Pumping machinery at 1st water works , RCC pipe NP-2 Inlet channel , RCC S/W for Raw water , 2 nos. Double layer brick lined S/S Tank , Rapid Sand Filtration P
2023_HRY_257963_1
2023168ED3E8 6FD2 4EEA A074 79E7FF995A8A564PUH
Open Tender
Civil Works
Works
700 days
SISWAL
3 documents required · 3 mandatory
₹20,000
Yes
₹18.8 L
Yes
3 Nov 2023
10 Feb 2023
3 Mar 2023
10 Feb 2023
3 Mar 2023
10 Feb 2023
10 Feb 2023 - 3 Mar 2023
Amount
Supply, erection, testing and commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of suitable size deep having follwing items At 1st. W/W :For 1 no Pumping Sets of 3800 LPM x 40 m Head a) Main switch suitable amp. 1 No. (LandT Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 3800 LPM x 40 m Head = 1 Nos (LandT Siemens, ABB) f) VSS 1 No. and ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect.
Supply erection testing of reputed make LED light 100 wats with fittings and accessories complete in all respects...
Supplying, erection, testing and commissioning of horizontal motor pumping set for clear water having head 45.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked35 Discharge capacity (LPM) 3000 power capacity Clear water Pump 3000 LPM X 45m
Design, construction, testing and commissioning of 2.00 MLD capacity Water treatment plant including inlet channel, Alum dozing, Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank including all civil work, pumping machineries and electric cabling, control panels, entire piping network of suitable size laying the DI pipe from raw water pump to inlet box of WTP, WTP to CWT and Suction Well for CW including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (Sluice valves of make IVC/VAG) ....
Supplying, erection, testing and commissioning of Horizontal motor pumping set for raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. 1600 LPM X 12 M. Head (At 2nd. Water works)
Provision for crossing the Hisar Drain by over steel Truss Bridge including all material, loading, unloading, transportation, labor charges, pile foundations, concrete block etc which ever required complete in all respect.
Supplying, erection, testing and commissioning of Horizontal motor pumping set for clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. 3800 LPM X 40 M. Head (At 1st. Water works)
Operation and Maintenance of water works for complete scope of work mentioned in the DNIT and of whole existing water supply system in the village Disinfection material supplied by the PHED as per schedule-IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period. (will be charged to the A/mtc estimate). complete in all respects as per approved NIT. 1.) Defect liability period (Operation only)
Operation and Maintenance for 1st year (after defect liability period).
Operation and Maintenance for 2nd year (after defect liability period).
Operation and Maintenance for 3rd year (after defect liability period).
Operation and Maintenance for 4th year (after defect liability period).
Operation and Maintenance for 5th year (after defect liability period).
Bidder Name
Amount
Ravinder Sharma Contractor(GSTN-06APJPR8270D1ZO)
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
NAFE SINGH CONTRACTOR(GSTN-NA)
ROHTASH KUMAR CONTRACTOR
NAFE SINGH CONTRACTOR
NAFE SINGH CONTRACTOR
ROHTASH KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .