| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹44.4 L+₹4.5 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹45.5 L+₹5.7 L (14.2%)Rejected-Finance | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹46.9 L+₹7.1 L (17.7%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹47.0 L+₹7.1 L (17.9%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
₹45.7 L
EMD Value
₹91,380
Closing Date
25 Jun 2022, 6:00 pmClosed
Major Deepak Kumar
Garrison Engineer Jhansi
PROVN OF GUN SHEDS FOR 18 X K-9 VAJRA-T AT GUN PARK OF 269 MED REGT (SP) AND SPECIAL REPAIR TO HARD STANDING FOR PARKING OF TFF SAR AND AMB VEHS OF 664 ARMY AVN SQN (R O) UNDER AGE B/R-II AT GE JHANSI
2022_MES_527440_1
GE/JHA/TOK/14 OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹91,380
Yes
27 Aug 2022
30 May 2022
27 Jun 2022
30 May 2022
25 Jun 2022
12 Jun 2022
Amount
Excavation in trenches n.exc 1.5m deep and n.exc 1.5Mt wide and getting out in soft/loose soil complete all as specified.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed
S&F of Structural steel for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and incl one coat of red oxide primer with and incl preparation of new surface of steel not exc 10 cm in width or girth, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for RCC M-20 type (using 20mm graded stone aggregate) as in foundations, incl rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
M&L for mild steel work as in wind ties for roof including securing bolts necessary drilling, bolting etc, complete all as specified and directed.
M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment incl fabrication, Fe-410-W (Gde-E-250) quality-B, complete all as specified and directed.
M&L for pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of green colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed. Make : Jindal / Tata / Everest
M&L for pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based plain steel sheet of green colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed. Make : Jindal / Tata / Everest
Returning filling in trenches including spreading leveling and well ramming with water complete n.exc 25 cm thick in each layer in soft/loose soil.
M&L Hardcore (Broken stone or boulders) of guage exc 63mm but n exc.100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L for moorum/red bajri in floors or paving laid in layers n exc 15 cm thick, spread, levelled and rammed including watering
M&L for 150 mm thick PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in sub-base, floors paving etc
M&L for 75 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in sub-base, floors paving etc
M&L for Granolithic concrete 1:1:2 floor topping 30mm thick; laid over cement concrete subfloors etc. and finished to an even and fair surface complete all as specified and directed
M&L for Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed, bedded with 15mm thick Screed bed in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush, complete all as specified and directed.
M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in coping complete all as specified and as directed.
Demolition of cement concrete in ground floor including terrazo flooring and paving n exc 15cm thickness (below or above the ground level) built in cement mortar and rubbish off the premises, Complete all as specified and directed
S&F 28 mm glass dividing strips, 3mm thick, inserted in position and conform to design, complete all as specified and directed
Material and Labour for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm laid on structural steel with proper clamp complete all as specified and directed by Engineer-in-Charge for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
All as per srl item no. 22.00 here-in-before but 2runs x 2.5 Sqmm (P+N)+1run x 2.5Sqmm (E)
All as per srl item no. 22.00 here-in-before but 2runs x 1.5 Sqmm(P+N) +1run x 1.5 Sqmm(E).
Supply and fix switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fix ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed.
Supply and fix MCB distribution board, SPN 8 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
Supply and fix in replacement of MCB distribution board, SPN, 12 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
Supply and fix MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 2 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion including removing of existing earthing complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .