| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.9 LAccepted-AOC 30 20 ATHIPALAYAM ROAD CHINNAVEDAM PATTI POST COIMBATORE 641 006 TN | COIMBATORE | COIMBATORE | TAMIL NADU | 641006 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹73.7 L+₹4.7 L (6.88%)Rejected-Finance 7 345 C 1 AERO NAGAR KANGEYAMPALAYAM KADAMPADI SULUR COIMBATORE TAMIL NADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹74.3 L+₹5.3 L (7.74%)Rejected-Finance 2 375 ARAVENU POST KOTAGIRI THE NILGIRIS TAMIL NADU 643 201 | KOTAGIRI | THE NILGIRIS | TAMIL NADU | 643201 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹74.8 L+₹5.9 L (8.55%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹75.2 L+₹6.2 L (9.04%)Rejected-Finance SOUTH VIJAYANARAYANAM 1 33 CENTRAL STREET NANGUNERI TALUK TIRUNELVELI DIST TAMIL NADU 627 118 | SOUTH VIJAYANARAYANAM | TIRUNELVELI | TAMIL NADU | 627118 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
20 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF QTY 02 ADDITIONAL ROOMS AND CERTAIN SANCTIONED WORKS AT AF STN SULUR
2023_MES_582060_1
8547/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹1.3 L
Yes
23 Mar 2023
21 Feb 2023
21 Mar 2023
21 Feb 2023
20 Mar 2023
14 Mar 2023
21 Feb 2023 - 10 Mar 2023
Amount
SCHEDULE A BOQ
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in hard dense soil complete all as specified and as directed.
M&L for PCC in foundation filling and mass concrete type D-2, 1:4:8, using 40mm graded stone aggregate complete all as specified and directed.
M & L Reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in columns , pillars, post and struts etc complete all as specified and as directed
M & L Reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in footing, foundation beams, plinth beams,bases for columns etc and mass concrete etc complete all as specified and as directed
M & L Reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed
M & L Reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M & L Reinforced cement concrete design mix in M-25 using 20mm graded crushed stone aggregate as in chajjas complete all as specified and as directed
M & L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete complete all as specified and as directed.
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal, rough finished flat surfaces of concrete complete all as specified and as directed.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surfaces of concrete complete all as specified and as directed.
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M & L for form work to chullah hoods, chajjas, troughs and similar items including edges with fair finished flat surfaces of concrete complete all as specified and as directed.
M&L form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work: not exceeding 200mm thick (Horizontal or sloping) fair finished flat surfaces of concrete complete all as specified and as directed.
S&F High strength corrosion resistant, TMTsteel bar of grade Fe-500, 5 mm dia and above and up to 10 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips in stirrups , spacers and binders etc complete all as specified and directed.
S&F High strength corrosion resistant TMTsteel bars of Grade Fe–500 of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified.
M & L Pre-cast cement 1:3:6, type C-1 (20mm graded stone aggregate) concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and directed.
M&L Rendering 15 mm thick in two layers on brick or concrete wall surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note : Water proofing compound shall be measured and paid seperately.
M&L Rendering 10 mm thick on brick or concrete wall surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note : Water proofing compound shall be measured and paid seperately.
Supply only integral water proofing compound
M&L Rendering 10 mm thick on brick or concrete wall surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 10 mm thick on concrete ceiling surfaces in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
M&L Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper complete all as specified and directed.
M&L applying two coats of cement based paint including preparation of new plastered wall surfaces of any description, complete all as specified and as directed.
M&L Preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper complete all as specified and directed.
M&L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8, type-D-2 using 40 mm graded stone aggregate as in sub base floors complete all as specified and as directed.
M&L 100 mm thick PCC 1:2:4, type-B-1 using 20 mm graded stone aggregate as in flooring finished even and smooth without using extra cement complete all as specified and as directed.
M & L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and directed.
M & L damp proof course 40 mm thick, in plain cement concrete1:2:4, type B-0, using 12.5 mm graded stone aggregate including necessary formwork complete all as specified and as directed
S&F steel windows with side hung shutters including projecting type hinges with steel handles and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F 3 mm thick sheet glass, ordinary quality, ground or obscured or frosted, on one side and shapes in squares not exceeding 0.5 Sqm in each pane glazed with putty or fixed with aluminium beads complete all as specified and directed.
S&F framed work such as grills, grating, etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, formwork of water tanks and similar works confirming to Fe-290 grade-E 165 complete all as specified and directed.
M & L Preparation of new wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M & L Preparation of new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Note for item No 34 & 35 :- (a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
S&F 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, comercial type on both faces complete all as specified and directed.
M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
S&F 150 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed.
S&F 200mm extruded aluminum alloy handles, cast type, anodised complete all as specified and as directed.
S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor 150mm complete all as specified and as directed.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings conforming to Fe 410 -W (GdeE-250) qualityA- (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed.
M&L Water proofing treatment of roof as per details given below complete all as specified and as directed :-
Note for Item No 52 :- (a) Surface should be free from any loose paint, dust or grease.
(b) Apply a coat of self priming smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical with 33% dilution with water using brush/roller on newly plastered surface after curing as per IS-456 and allow to dry for 4 to 6 hours (dilution & forced coverage requirement strictly as per manufacturer’s instructions).
(c) After the primed surface has dried, apply first coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same primed surface & allow to dry for 4 to 6 hours.
(d) Prepare for apply 2nd coat of water proofing smart care damp proof ultra (Code 5698) of M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical using brush/roller on the same surface. The temp to be maintained 25 to 35° C through out the all above application work.
Notes :- (i) The work shall be carried out through authorized and qualified applicators of the following manufacturers only. MOU to be submitted before commencement of work. Make : M/s Asian paints or equivalent in M/s Dr Fixit or M/s Pidilite or M/s Sika chemical
(ii) A performance guarantee certificate for 10 years shall be submitted by the contractor to the GE on completion of work as specified.
(iii) The unit quoted rate is deemed to include taking down of water pipeline, tanks, wires (etc) found on roof and refix at the original position after complete treatment of roof.
(iv) The unit quoted rate shall be inclusive of material, all labours, tools and plants including scaffolding required for working upto approx 7.5 mtr height from natural ground level.
(vi) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at height exceeding 3 to 25 mtr height shall be mandatary and deemed to be included in the unit rate quoted.
M & L treating the soil under plinth protection using anti termite treatment emulsion @ 5 litres per square metre of surface area complete all as specified and directed.
M & L treating the soil along with external perimeter of building using anti termite treatment emulsion @ 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M & L treating the backfill in contact with foundation using anti termite treatment emulsion @ 7.5 litres per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M & L Treating the top surface of filled earth with anti termite treatment emulsion @ 5 litres per square metre of surface complete all as specified and directed.
M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), as in plinth protection/path/hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cemen complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M&L Spreading and leveling the soils in layers not exceeding 25 cm thick each layer including watering and well ramming complete all as specified and directed.
S&F steel rolling shutters , thickness of lath 1.25mm, with ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with bevel gear box and crank handle complete all as specified and directed.
S&F in Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
M&L Steel work in tubular trusses, purlins,rafter etc.including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed
S&F in Fibre glass reinforced translucent corrugated sheeting 2mm thick with two corrugation side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed
Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Removing of excavated material or demolished concrete debris exc 1.5 KM but n exc 5 KM and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L Reinforced cement concrete (nominal mix ) 1:1 1/2 :3 type A-1 (using 20mm graded crushed stone aggregate) as deck slabs and in shelves and the like complete all as specified and as directed
M&L Reinforced cement concrete (nominal mix ) 1:1 1/2 :3 type A-1 (using 20mm graded crushed stone aggregate) as in walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and as directed
M & L formwork to faces of walls, abutments, parapets and similar work including attached pillasters, buttresses, etc.; vertical or to batter fair finished flat surfaces of concrete complete all as specified and as directed.
S&F High strength corrosion resistant TMT bars of Grade Fe–500 of 6mm to 8mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and directed.
M & L 3mm thick wall care putty on new concrete wall surfaces complete all as specified and directed.
M & L 3mm thick wall care putty on new concrete ceiling surfaces complete all as specified and directed.
Supply and laying XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, etc all as specified and directed.
Note for Item No 80 :- Excavation and earth work, riddling sand, and cable protection cover shall be measured and paid seperately.
M & L Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed.
Note for Item No 82 :- The rate is deemed to be inclusive to bring additional quantity of riddled sand from out side MD land, in case sufficient sand not obtained from excavation as directed by the Engineer-in-Charge.
S&F Fly ash bricks using sub class B bricks as in cable protection cover complete all as per specified and as directed.
Returning, refilling including spreading levelling watering and well ramming in layers not exceeding 25cms thick in hard/dense soil complete all as per specified and as directed.
Supply and laying GI pipe 40 mm bore light grade for cable protection complete all as specified and as dierced by Engr-in-Charge.
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as per specified and as directed.
S & F Air termination single pointed aluminium rod of 12mm dia 300mm length fixed to aluminium strip 25x3.15mm including nuts, bolts and washers complete all as specified and as directed.
S & F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
S & F Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc including taking down existing one all as specified.
Note for Item No 90 :- Quoted Unit Rate deemed to be inclusive for drilling holes per Metre or as specified on GI/Aluminium/Copper Strip of any type and size.
S & F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 Nos. 8mm dia, 25mm long hexagonal head screw complete all as per specified and as directed.
Supply and Fix GI pipe 40 mm bore light grade for supporting air termination rod in position with necessary cutting and fixing on roof by necessary PCC foundation complete all as specified and as dierced by Engr-in-Charge.
M&L Earthing complete with Copper earth plate electrode 600mmx600mmx3.15mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with copper earth strip 20mmx3mm thick and GI bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connecting to test point, all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook, and provn of test point complete all as specified and directed.
Note for Item No 94 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
(e) Copper strip 20x3 mm upto 7.5 Mtrs shall be included in quoted rates and beyond 7.5 mtrs shall be measured and paid separately under relevent item.
M &L Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl Stove enemelled steel conduit with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with plastic laminated top cover 2.8mm fixed with cadmium plated iron screws etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for one flame proof light point controlled by one switch complete all as specified and directed.
S&F Switch flame proof rotary type with termination box in LM6, 16A, double pole 250V complete all as specified and directed.
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing Flameproof /Weatherproof Flood Light fitting in Cast Alluminium alloy construction suitable For 100W LED.Certified by CMRS,Dhanbad for Group IIA & IIB complete all as specified and directed. Make :- Cat.No.WG/1240 of Sudhir or equivalent approved make.
S&F Flameproof Weatherproof Distribution in Cast Aluminium alloy LM6 Construction.4Way.Cat.No. MCDB/186. Certified by CMRS, Dhanbad for Group IIA & IIB.Consisting with :- Incoming: - 1No of 63A TPN MCB. Outgoing: - 06 Nos of 20A SP MCB & 04 Nos of 6A SP MCB.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed.
Note for Item No 105:- (a) All Joints should be joined by Exothermic Welding or Brazing.
M & L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed.
Notes for item No 107:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge user and proper record shall be mainted duly signed by all concerned.
(e) After testing if desired earth resistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Supply and install Split Type air Conditioners Fitted with hermitically sealed compressor operating on refrigeration R-410/R-407 suitable for 230V, I 10% 50 Hz single phase AC supply, suitable For 1.5 Ton Fram mounting with flameproof motor,certified with CMRI Dhanbad for gas group IIC, cooling coils, with following specification:- Tubing Material :- Copper. Coil Material :-Copper. Construction (Indoor & Outdoor Unit Body) 9.1Cooling Capacity In BTU/Hr :-24000 Area Classification:- Split Air Conditioner/Individual Components Of Split Air Conditioner Should Be Flameproof & Suitable For Class1, Division2, Group : D/Zone 2, Group IIC. Certification : CMRI/PESO/CIMFR Tubing Length: Min 10Mtrs Each Cable Length: 3C X 2.5sqmm. PVC insulated Copper Cable of 10Mtrs Length For Power Chord and 10Meters Length Between indoor & outdoor Unit. (Note: Above Air Conditioners supply along with Changeover Timer)
Supply and install Dehumidifier single phase, 240 V, 50 Hz of following parameters:- Process Air Flow (CMH) 300, Reactivation Air Flow (CMH) 100, Reactivation Heater - 2.5 KW, Supply Air (CFM) 177, Filtration G4, ESP of Process Air Fan (Pa) 20, ESP of Reactivation Air Fan (Pa) 10, Process Fan Motor - 0.37 KW, Reactivation Fan Motor - 0.37 KW . Make: SALLERIA Model -DD-20 or equivalent approved make.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket including one single pole MCB 20 Amp complete all as specified and directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including stove enamelled steel conduit of suitable size and all accessories fixed to wall/floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
Note for Item No 116 :- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of steel conduit shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S & F palm size electrostatic detector with following parameters:- portable working temperature :- 0.5 degree celcius, sensing range :- 100V-25 KV, measuring distance :- 10 mm (optimal), measuring method :- Hand held non contact measurement
Supply and fix copper bonding strips of size 50mm x 5mm thick with necessary accessories on the sub floor in the form of grid to recieve anti-static flooring complete all as specified and directed.
S & F MCCB, 4 Pole, 63 Amps, thermal magnetic release adjustable type, 415 Volt, 25 KA including enclosure connecting with suitable size of copper lugs complete all as specified and as directed.
Supply, install, testing and commissioning of wall mounted star rated hi-wall split AC units indoor/outdoor of capacity 1.5 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.complete all as specified and as directed
Supply, install, testing and commissioning of wall mounted star rated hi-wall split AC units indoor/outdoor of capacity 2 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.complete all as specified and as directed
Supply, install, testing and commissioning of Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with ouput voltage stabilized at 230V with accuracy (+) or (-) 2.5% and speed of correction 8 Volts per second and of capacity 4 KVA all as specified and as directed.
Supply, install, testing and commissioning of Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with ouput voltage stabilized at 230V with accuracy (+) or (-) 2.5% and speed of correction 8 Volts per second and of capacity 5 KVA all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including non metallic rigid PVC conduit/casing capping of suitable size and all accessories fixed to wall/floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed.
Note for Item No 126:- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC conduit/casing capping shall be measured as one length.
(b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S & F Metal clad socket Single pole and neutral enclosure with a two pin and earth plug and socket including one single pole MCB 32 Amp complete all as specified and directed.
S & F digital heavy duty AC timer, wall mounting type with automatic change over dynamic brand connector of 30 Amps for cyclic operation of alternative running of two AC with 8 hours interval complete all as specified and directed.
Supply install testing and commissioning of Double skin DEHUMIDIFIER unit with following parameters:- SALLARIA-DD-20, process air flow- 300 CMH, Reaction air flow-100 CMH, Reactivation Heater-2.5 KW, Supply air-177 CFM
S&F 250mm aluminium alloy, anodised , sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extrude3d sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F on distribution boards, initial fixing of single pole MCB 10 to 32 Amps, 240V, 50Hz, AC suitable for C'curve, 10KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No 408590 to 408595 or equivalent of Schnieder / Siemens / L&T.
p.chinnasamy
G Perumal and co
T C KARUNANITHI
m/s m valasubramanian
Neptune Engineers and Builders
S.RAMACHANDRAN
Lucky Enterprises
A.GOVINDARAJ
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .