| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.4 LAccepted-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L1 | Accepted-AOC QUOTED AMOUNT IS REASONABLE | |
| 2 | L2₹95.0 L+₹32,418.05 (0.34%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹96.9 L+₹2.3 L (2.41%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹97.7 L+₹3.1 L (3.27%)Rejected-Finance HOUSE NO 86 SUJEET VERMA RAJEEV NAGAR PH 3 DELHI NORTH WEST DELHI DELHI 110086 UDYAM DL 06 0117122 | NORTH WEST DELHI | DELHI | 110086 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹98.4 L+₹3.8 L (4.02%)Rejected-Finance 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | J.P. Enterprises L8 | M/s Verma and Co L4 | M/S Rohit Enterprises L2 | M/S Yamin L6 | Singh Associates L1 | V M CONSTRUCTION L5 | Vipul Construction L7 | Vinay Shankar L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling plain or corrugated Asbestos cement sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. | 514.8 | Sqm | 12 ₹6,177.6 | 20 ₹10,296 | 10 ₹5,148 Lowest | 30 ₹15,444 | 17 ₹8,751.6 | 15 ₹7,722 | 15 ₹7,722 | 20 ₹10,296 |
| 2.00 | S&F in position Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. | 491.4 | Sqm | 800 ₹3,93,120 | 680 ₹3,34,152 | 700 ₹3,43,980 | 650 ₹3,19,410 Lowest | 747 ₹3,67,075.8 | 650 ₹3,19,410 Lowest | 695 ₹3,41,523 | 700 ₹3,43,980 |
| 3.00 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/valley gutter, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. | 23.4 | Sqm | 800 ₹18,720 | 710 ₹16,614 | 700 ₹16,380 | 650 ₹15,210 | 777 ₹18,181.8 | 640 ₹14,976 Lowest | 695 ₹16,263 | 700 ₹16,380 |
| 4.00 | Dismantling wooden truss of any description not otherwise provided for complete all as specified and as directed. | 19 | Each | 200 ₹3,800 | 200 ₹3,800 | 100 ₹1,900 Lowest | 500 ₹9,500 | 277 ₹5,263 | 400 ₹7,600 | 500 ₹9,500 | 1,000 ₹19,000 |
| 5.00 | Dismantling timber scantling in fillet, rail post, rafter, purlin etc under 40 Sqcm in section in any position unfarmed work complete all as specified and directed. | 511.55 | Rm | 20 ₹10,231 | 50 ₹25,577.5 | 10 ₹5,115.5 Lowest | 30 ₹15,346.5 | 27 ₹13,811.85 | 20 ₹10,231 | 35 ₹17,904.25 | 20 ₹10,231 |
| 6.00 | Dismantling posts & struts (Wood, steel, RCC) any section including taking out embeded portion and making good disturbed ground post embeded in concrete complete all as specified. | 57 | Rm | 20 ₹1,140 | 100 ₹5,700 | 10 ₹570 Lowest | 12 ₹684 | 27 ₹1,539 | 50 ₹2,850 | 10 ₹570 Lowest | 50 ₹2,850 |
| 7.00 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft/loose soil including PCC, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed. | 14 | Each | 500 ₹7,000 | 250 ₹3,500 | 200 ₹2,800 | 150 ₹2,100 | 177 ₹2,478 | 200 ₹2,800 | 100 ₹1,400 Lowest | 200 ₹2,800 |
| 8.00 | M&L for PCC 1:3:6 Type C-2 (40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and as directed. | 0.57 | Cum | 4,000 ₹2,280 | 3,500 ₹1,995 | 4,000 ₹2,280 | 3,000 ₹1,710 Lowest | 4,477 ₹2,551.89 | 3,400 ₹1,938 | 4,200 ₹2,394 | 4,000 ₹2,280 |
| 9.00 | S&F steel work in tubular column, purline, rafter etc using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 including one shop coat of zinc chromate primer (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed. | 6,438.75 | Kg | 115 ₹7,40,456.71 | 90 ₹5,79,487.86 | 80 ₹5,15,100.32 | 95 ₹6,11,681.63 | 67 ₹4,31,396.52 Lowest | 100 ₹6,43,875.4 | 115 ₹7,40,456.71 | 100 ₹6,43,875.4 |
| 10.00 | S&F mild steel plate (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes with welded attachment to GI pipe in base/ connections etc. including one shop coat of zinc chromate primer (including preparation of surface) at Contractor’s workshop before fabrication Fe 410 -W (Gde-E- 250) quality-A complete all as specified and as directed. | 52.75 | Kg | 115 ₹6,066.48 | 90 ₹4,747.68 Lowest | 120 ₹6,330.24 | 90 ₹4,747.68 Lowest | 177 ₹9,337.1 | 120 ₹6,330.24 | 125 ₹6,594 | 100 ₹5,275.2 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
18 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
SPL REPAIR OF BLDG NO P-84A AND T-101 (SINGLE NURSING OFFRS) AT BHDC GE (EAST) DELHI CANTT-10
2025_MES_724862_1
CWE/D-41/2025-26
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE EAST DELHI CANTT
₹2.1 L
Yes
12 Jan 2026
6 Aug 2025
21 Oct 2025
6 Aug 2025
18 Oct 2025
11 Oct 2025
Amount
Dismantling plain or corrugated Asbestos cement sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F in position Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/valley gutter, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling wooden truss of any description not otherwise provided for complete all as specified and as directed.
Dismantling timber scantling in fillet, rail post, rafter, purlin etc under 40 Sqcm in section in any position unfarmed work complete all as specified and directed.
Dismantling posts & struts (Wood, steel, RCC) any section including taking out embeded portion and making good disturbed ground post embeded in concrete complete all as specified.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft/loose soil including PCC, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed.
M&L for PCC 1:3:6 Type C-2 (40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
S&F steel work in tubular column, purline, rafter etc using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 including one shop coat of zinc chromate primer (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed.
S&F mild steel plate (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes with welded attachment to GI pipe in base/ connections etc. including one shop coat of zinc chromate primer (including preparation of surface) at Contractor’s workshop before fabrication Fe 410 -W (Gde-E- 250) quality-A complete all as specified and as directed.
M&L preparation of new steel surface over 10cm width/girth and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, laid in CM for ashlars facings, dressed stonework, precast concrete articles and precast concrete block walling.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 M mean radius, using old size bricks built in CM 1:6 all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping / bed blocks incl. weathering rounded or chamfered angles and throating incl. necessary form work req. as in specified and directed
Taking down of chowkhat or frame (without taking off shutter from frame) area not exc 1.50 Sqm each including builder hardware fitting complete all as specified and as directed.
All as per item No 15.00 here in Before but area exc 1.50 Sqm & not exc 4.00 Sqm each complete all as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm one side prelaminated and other side plain colour PVC sheet & edges will be painted to match with prelaminated sheet reinforced with M.S. Square tube, suppling & fixed with screw/plugs to brick walls complete as per specification & drawing. Make Black Cobra or equivalent as per approved make list.
S&F Factory made Solid PVC Moulded Door Shutter 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed. Make Black Cobra or equivalent as per approved make list.
S&F MS rolled section for Framed work as in doors, Chowkhats or gates of angle or other section with gusset plates, rails, braces,and hold fast etc., complete all as specified and directed.(Fe 290 gde E 165)
S&F Factory made single extruded WPC (Wood Polymer Composite) solid coloured Decorative type flush shutter of 30 mm thick size comprising of virgin polymer of K velue 58-60 (Suspemtion Grade ), Clcium carbonate and Natural fibers (Wood power/rice husk/weat husk) and non toxic additives (Meximum toxicity index of 12 for 100 grm) having minimum density of 650 Kg/Cum and screw withdrawal strangth 50 N / mm modulus of elasticity 850 N/mm sqr and resistence to spread of frame of class A category with property of being termite/ borer proof, water / moisture proof and fire retardant WPC to be laminated with PVC foil of min 14 micronsthic of approved design and fixing with stainless stell butt hinges of required size fixing in frame at site as per specification & drawing complete all as specified and directed. Make Black Cobra or equivalent as per approved make list.
S&F 30mm thick " FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws etc. Complete as per direction of Engineer-in -charge, manufacturer's specification & drawings. Make Black Cobra or equivalent as per approved make list.
S&F powder coated aluminium of various section as required for frame of windown/ventilators etc with one or more rebates including jointing cleats for fixing etc complete all as specified and directed.
M&L anodised aluminium three tracks sliding windows with frame size 60x40x2.00mm thick and shutter with section bearing bottom 25x18x1.50, top 39.4x17.7 X1.50 mm ( suitable for moving over three track fixed over top of frame work , top and side section of size 61.6 x 31.75x1.5mm and bearing bottom track of size 61.6x 31.75x1.5mm or fixing with hinges including necessary aluminium jointing cleats, glazing cleats, rubber packing anodised snape beading, screws etc with 5 mm thick tinted/ plain glass and wiremesh shutters in panels with EPDM Gasket incl all fitting and fixture complete all as spesified and directed.
S&F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 200 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 200mm long Aluminum anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long aluminum handles, cast type anodised complete all as specified and directed.
S&F 100 mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F 140mm long floor door stopper fency type of Aluminum alloy body and tongue, anodised with hand drawn steel spring fixed in floor.
S & F Door closer Aluminium (extruded section) body hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and as directed.
M&L 25 mm thick PCC 1:2:4, Type B1, using 20 mm graded stone aggregate, below tiles for levelling of existing surface complete all as specified and as directed.
S&F Glazed coloured Vitrified tiles(light shade) 10 mm thick (square/ rectangular) polished, area of each tiles Not exceeding 0.36 sqm, in floors etc. laid over 15 mm thick cement screed in cm 1:6, set and jointed in neat cement slurry and pointed pointed in white or coloured cement to match complete all as specified and as directed.
S & F non skid ceramic coloured tiles 7 to 8mm thick area of each tiles exceeding 0.11 sqmm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match, over 15mm thick screed bed in CM (1:6) completed.
M&L glazed coloured ceramic tiles, 600x300x7mm thick, in vertical surfaces such as skirting/dado etc, set and jointed in cement slurry, laid over & including 10mm thick rendering in cement mortar 1:4, set, jointed and pointed in white cement mixed with colour pigment to match the shade of tile complete all as specified and as directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base 15mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and filling epoxy grout over it including rubbing and polishing complete all as specified.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick backing coat in CM 1:4 and jointed with pigment to match the shade of the slab including rubbing and polishing complete all as specified
Taking down cement plaster/grit plaster on brick or stone walls etc. including raking out of joints, hacking for key, scrubbing down with water etc. of any description complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar 1:6 on brick or concrete surfaces of walls, finished the surface fair and even without using extra cement complete all as specified and as directed.
M & L 15 mm thick rendering in cement mortar (1:4), on brick or concrete wall surface, mixed with water proofing compound @ 3% by weight of cement, finished fair & even without using extra cement complete all as specified and as directed.
Supply only water proofing Compound
M&L preparation of new plastered wall surfaces and applying two coats of Oil Bound Distemper over and including over and including 3 mm thick cement based wall care putty complete all as specified and as directed.
M&L preparation of new plastered wall surfaces and applying two coats of weather proof Exterior emulsion paint of colour & shade as approved (Colour scheme shall be as approved by the GE & user) over and including a coat of priming paint, over and including 3 mm thick cement based wall care putty complete all as specified and as directed. Make - Asian Apex Ultima or equivalent of make specified in PS.
M & L for washed stone grit plaster on exterior walls in two layers, under layers 12 mm thick cement plaster 1:4 (1 cement :4 coarse sand) following the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer with 15 mm thick cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand:2 coloured marble stone chipping 10mm nominal size) including using Colour pigment & marble powder as required in ground in panels with groove all around as per approved pattern including scrubbing and washing the top layer with wire brushes and water to expose the stone chippings includind forming groove of uniform size 15mm wide and 15mm deep as per approved pattern complete all as specified and as directed.
Supply and fabrication & fixing of Modular wardrobe,cupboards, cabinets, drawers , shelfs, vanity , dressing table including shutters ( depth of 45 Cm up to 70 Cm) etc , all front side, bottom, top, two sides and partions etc made out of 15-18 mm thick HDHMR board and back side made out of 8 - 10 mm thick HDHMR board (Action tesa or equivalent ) with machine pressed 0.5 to 0.8 mm thick fabric/glossy colour laminate on all exposed front side and other sides decorative laminations . All exposed edges of boards with machine pressed edge band 0.8mm from rehau Germanetc (colour of laminates , design & paterns of partations/ etc as approved by GE) including all accessories of fittings - Stainless steel Basket in case of kitchen cabinet,SS Handle, Auto/soft closing hinges for shutters , C/J gola profile for handel less, telescopic channels 18'' / 20'' long , rollers for smooths sliding of drawers, etc as required complete all as specified and as directed. (Note : Overall net size front side including frame will be measured for payment purpose)
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and frame work etc complete all as specified and as directed.
Providing and fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) with semi perforated 12mm thick micro tegular edged false ceiling tiles of size 595 x 595mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 90%, NRCO 0.50 to 0.75 as per IS 8225:1987, Nocumbustible as per BS 476 (Part-4) -1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspende on interlocking metal T Grid of hot dipped galvanised iron section of 0.33mm thick (Galvanised @ 120 Grams per sqm including both side) comprising of main T runners of size 15 x 32mm length 3000mm, cross T of size 15 x 32mm length 1200mm and secondary intermediate cross -T of size 15 x 32mm of length 600mm to form grid module of size 600 x 600mm, grid system hanges by 6 mm dia GI wire to purlin, trusses; RCC slab of the roof etc. with hold down clips, butterfly clips, height fixtures etc, Galvanised iron parimeter wall angle of soze 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per sepcifications, drawing and as per direction of Engineer-in-Charge. (Make: DIAMOND/ GYPROC/ USG BORAL/ KNAUF/ ARMSTRONG)
M&L false ceiling using powder coated grid system of GI modular grid size 600 x 600 mm with runner 38x24x1.5 mm cross tee 25x24x1.5 mm and wall angle 24x24x1.5 mm thick PVC laminated Gypsum tiles of size 600 x 600 mm of different designs with rear side MPL film fitted in the grid, grid system hanges by 6 mm dia GI wire to purlin, trusses; RCC slab of the roof etc. with hold down clips, butterfly clips, height fixtures etc, complete all as specified and directed.
Dismantling water tanks including ball valve and all other connection cap exc 500 ltr but n.exc 1000 ltr and removing from site complete all as specified & directed by Engg in Charge.
S&F Rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position including minor repairing to iron pipe for making connections all as specified in SSR Part In any position white in colour 1000 ltr capacity complete all as specified.
S & F ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of 20mm dia all as specified
S & F in repairs Vitreous china floor mounted WC ( Cascade) one piece type (off white) including connecetion in drain etc incl water closet seat cover , flushing cistern, with P or S trap with all fitting and fixture complete all as specified and as directed.
S & F in repair Vitreous China wash down water closet pan (pedestal pattern) of size 580 mm white with ‘P’ or ‘S” trap, any pattern including Seat Cover (excluding flushing cistern and flush pipe) complete all as specified and as directed.
S & F in repair 10 Ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
S&F in repair PVC connection 15mm bore with PTMT nuts of length 600mm complete all as specified and directed.
S&F in repairs, health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connection and fixed in position complete in all respect as specfified and directed by Engr-in-Charge.
S&F in replacement for CP toilet paper holder fixing to wall with ss screw compete all as specified and directed.
S&F insheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long.
S&F in repair white Wash Basin with full Pedestal fo size 560 x 415 x 820 mm complete all as specified and directed. Make : Prayag/ Hindware/ Cera.
S&F 15mm bore brass CP WHB mixer swan neck type for mixing hot & cold, elbow operated water screwed down for iron pipe and fixed complete.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs Kitchen sink mixer of cast copper alloy , fancy type , chromium plated, and mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.
S & F in repair brass chromium plated shower rose 125 mm with swivel joints including fixing to steel pipe or union.
S&F in repairs wall mixer 3-in-1 system with provision for both hand shower and overhead shower complete with 115 mm long bend pipe, connecting legs wall flange(excluding showers) of cast copper alloy , fancy type , chromium plated, and mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.
S & F in repair 100/110 mm dia PVC floor trap , with Stainless steel floor water Grating with cockroach trap 100 mm to 125 mm dia with or without hole for waste pipe including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F15 mm bore angle stop valves cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed withr iron pipe of union.
S &F in repairs brass chromium plated towel rack all as specified
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal to store
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings with outer dia 32 mm on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings with outer dia 25 mm on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings with outer dia 20mm on walls/ceiling or laying in floors complete all as specified and as directed.
S&F in repair CP Bib Cock 15mm long body with flange complete all as specified and as directed.
S&F in repair CP Soap Dish including chromium plated brass screws and plastic cleats complete all as specified and as directed.
Dismantling of PVC pip & fitting of any description & position up to 100 mm dia complete all as specified & directed.
PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) 75 mm bore pipe single socketed, in any length with rubber ring jointes , laid in trenches or in floor complete all as specified and directed.
S&F PVC (SWR) 110 bore pipe single socketed, in any length with rubber ring jointes , laid in trenches or in floor complete all as specified and directed.
S&F PVC (SWR) 110 bore pipe single socketed, in any length with rubber ring jointes ,fixed to wall complete all as specified and directed.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 110 x 75 mm PVC (SWR) reducers complete all as specified and directed.
S & F SS clamps heavy duty of 20 mmx 2 mm thick fixed by 8mm fastener for fixing PVC Pipe of 75 mm bore to wall or roof copletet all as specified and directed.
S & F SS clamps heavy duty of 20 mmx 2 mm thick fixed by 8mm fastener for fixing PVC Pipe of 110 mm bore to wall or roof copletet all as specified and directed.
S&F 110 mm PVC (SWR) junction single, (Single T) equal or unequal with access door.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal with acces door.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed stoneware)/pvc set in cement mortar 150 mm internal dia of pipe complete all as specified and directed.
M&L for 150 mm nominal size (DWCPE) Double wall corrugaged poly ethylene pipe ((SNB) including all fixing accessories of fittings like socket/spigot joint with elastomeric sealing ring, rubberring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as directed.
M&L cement mortar concrete bed to drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) incl packing under and against the sides of pipes after they are laid and tested in bores of pipe150mm dia complete all as specified and directed.
S&F 20 mm bore Brass Elbow for fixing of cpvc pipe complete all as specified and directed.
S&F 20 mm Brass Tee for fixing of cpvc pipe complete all as specified and directed.
S&F 20 mm Female Brass Threaded Adaptor (MTA/ MBTA) ) for fixing of cpvc pipe complete all as specified and directed.
S&F 20 mm Male Brass Threaded Adaptor (MTA/ MBTA) ) for fixing of cpvc pipe complete all as specified and directed.
S&F 25 x 20 mm Brass socket reducer for fixing of cpvc pipe complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and paving N exc 15cm thickness( below or above ground level) including disposal of all debris outside MoD land complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6, type C-2, using (40mm graded stone aggregate) as in plinth protection and finished the surface even and smooth without using extra cement, laid in panel, including filling the joints with sand mixed with bitumen in 1:1 ratio complete all as specified and as directed.
Dismantling / taking out of existing roof treatment with APP membrane of any thickness including taking out existing screed bed / rendering of any thickness with all necessary arrangements complete all as specified and directed.
Demolation of mud / cement concrete in roof including plastering and leeping including cleaning surface of roof with wire brush / mechnical brush throughly to remove old dirt / loose particles to expose clean concrete slab clean with watering etc complete all as specified and directed.
M&L for cutting out cracks to V section in existing roof or terracing, cleaning out, wetting,grouting with cement and sand slurry in 1:3 complete all as spesified and as directed.
M&L for PCC 1:2:4 type B-O using 12.50 mm graded stone agg with WPC as in padding to maintain proper slope as required all as specified (WPC shall be paid seperatly.)
M & L for rendering 15 mm thick in cement mortor 1:4 over PCC bedding with water Proofing compound and finishing the surface even and smooth without using extra cement complete all as specified directed.
M & L for providing and applying smart care Dampproof, a fidre reinforced elastometric liquid water prrofing membrane formulated with reinforced acrylic fibres having Sun Reflective Index (SRI) of 105 on horizontal/ vertical surfaces of roof/ wall/ chajjas in multiple costs @2.0 litre/ sqm. Primary coat is self-priming coat of elastomericwaterproofing liquid (Dilition with water in the ratio of 3:1, damp proof : Water) and other coat to be applied undiluted. The coating needs to be reinforced with 40GSM Geotextile, to sandwiched between 2nd &3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Cgarge. Make : SmartCare Damp Proof of Asian or equivelent in Berger/ Nerolac/ STP only. Notes: (1) The work shall be executed through authorised appplicatot of manufacturer only. (2) Authorised Applicator shall be approved by GE befor starting the work. (3) All materials shall be produced directly from manufacturer. The purchase voucher shall be produced to the Engineer-in-Cgarge for his verification of material. Engineer-in-Cgarge shall deface the original purchage vouchers. (4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water Proofingtreatment for a period of Eight years i fevour of GE. A sum equivelent to 2.5% ( Two point five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor's duues as security deposite. The contractor may, however, furnish a fixed deposite receipt in lieu from a Schedule bank pledged in fevour of Garrison Engineer.
Supply only liquid water proofing compound and to mixed as per manufacturer instruction complete all as specified.
S&F in repair Stainless steel curtain rod 20 mm bore with fixing brackets decorative Patteren, with 2 Nos Side Holder (Latoo) rollers etc. as in curtain rod complete all as specified and directed.
Demolition of reinforced cement concrete in ground floors and paving N exc 15cm thickness( below or above ground level) including disposal of all debris outside MoD land complete all as specified and directed.
M&L Concrete Type B0 1:2:4 (12.5 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M&L for mild steel 10 mm dia tmt bar and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc.
Description all as per item No 114 above but mild steel tmt bar 6mm to 8 mm dia.
M&L for 18-20 mm thick of approved shade granite stoneZ Black (superior Quality) slab (table rubbed and polished as in floors, jambs, steps, cooking platform etc and the like, over & including 15 mm thick screed in CM 1:6, pointed in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including two strip of line make on (tread of stair case) granite complete all as specified and directed
M&L for chipping of spalled and loose concrete and cleaning rust from reinforced by sand blasting scrubing down concrete surfaces with wire brushes cleaning with water allow to dry and applying a layer of Zn rich epoxy primer as an antirust on all exposed reinforcement followed by a layer of bounding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited all as specified and applying two layers of guniting over steel welded mesh 2 mm dia of wire and apprature 75mm,total thickness of guniting n.exc 40mm(avg thickness) in cement mortar 1.2 using OPC 53 Graded cement mixed with polycreate mixture@2% by weight of cement or as per manufacture instrs and finally applying cement plaster over guniting surface of reqd thickness to give even uniform and smooth finishes confirming to proper geometrics in cement mortar 1:3 to match the existing surfaces as in sides ,soffits of the slabs,chajja,fins,fascia,parapet,lintels,column,and beam etc complete incl necessary scaffolding,shuttering,chasing to bk work or RCC memebers at Any Height building incl removal of all small trees/shrubs etc.complete as per directed by Engr-in-Charge.
S&F stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling of Existing MS/RCC Railing complete all as specified and as directed.
M & L for preparing the old surface of wall by washing down and rubbing and removing all loose layers of old treatment, efflorescence , soot and moss by wire brush and filling all nail holes and patches with cement wall putty and applying one or more coat of oil bound distemper on patches to bring the whole surface at par and applying two coat of oil bound distemper over 1mm thick wall care putty on wall complete all as specified and directed.
All same as per srl item No 119 here-in-before but on ceiling complete.
M&L for preparation of old decorated, wall, chequered floor, roof (corrugal) surface, by brooming and removing all loose layers of old treatment, efflorescence soot and moss by wire brush and filling all nail holes and patches with cement based wall care putty and applying one coat of exterior emulsion paint of colour & shade as approved (to match with the Existing surface) complete all as specified and as directed. Make- Asian Apex Ultima or equivalent of make specified in PS. Note: Quoted rates shall deemed to be includes painting at any height including scaffolding work, as required.
M&L for prepration of old painted steel & iron surfaces of any description, over 10 cm width or girth and applying one coats of synthetic enamel paint all as specified
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness (below or above GL).
M&L for 25 mm PCC cement concrete type B1 1:2:4 (using 12.50mm graded aggregate) finishing concrete surface even and smooth with using extra cement complete all as specified
M&L for chequered cement concrete tiles with grey cement & pigments, size 20cmx20cmx 25 mm thick, set, jointed and pointed in neat cement slurry pigmented to match colour/shade of tiles as in floors etc.; laid over & including 20 mm thick screed bed or bedding layer in CM 1:4, etc. complete all as specified and directed by Engr-in-Charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials outside MOD land (As approved by local Municipal Authorities) by manual/mechanical means including loading, transporting and unloading the same complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and as directed.
Taking down the existing Exhaust fan/ Ceiling fan of any make or any sweep from its position and refixing in position complete all as specified and as directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
M&L point wiring for modular switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through concealed Conduit 25 mm as requirement of site including cadmium plated screws as per ISI, size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light/ fan point controlled by one switch 5 Amps one way single polecomplete all as specified and directed.
All as per item No. 130 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed.
All as per item No. 130 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed.
All as per item No. 130 here in before but point wiring with 1.5 Sqmm, multistranded, copper conductor cable, for One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size all as specified and as directed.
All as per item No. 130 here in before but one light point controlled by 2 way switch,with cables 1.5 sq mm size complete all as specified and as directed.
All as per item No. 130 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
All as per item No. 130 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on Same board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
All as per item No. 130 here in before but point wiring with 4 Sqmm, multistranded, copper conductor cable, for AC point and Geyser point on independent board with 4 Sqmm size earth conductor complete all as specified and as directed.
S&F sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed.
Supply and Fixing of five star rated Geysers white blue in colour capacity 25 Ltr, Electric Driven, Single phase, 240 V, Storage vertical type and heating element 2 KW, inner shell made up of copper, automatic cutoff,manual tempreture setting , maintaining 8 bar pressue including electrical and water connection with hot and cold water connection pipe (PVC type) and fixed on the wall with mild steel fastner 150 mm long and 10 mm dia with pin and bolts complete all as specified and directed. Note :- Old unserveciable Geysers will be deposited to MES store yard.
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 16 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement Modular Bell push 6A 1 module all as specified and as directed.
S&F in replacement Buzzer, Ding Dong AC. 230 volts, single pole all as specified and as directed.
S&F in replacement modular switch, 2 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F modular blanking plate, 1 Module complete all as specified and as directed.
M&L in replacement for sub main wiring with 2 runs of 10 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit 32mm medium grade as per ISS and one run of 6 sqmm size earth wire PVC insulated copper conductor complete all as specified and directed.(Note Two runs of 10 sqmm copper FRLS cable & one run of 6 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit.
M&L in replacement for sub main wiring with 2 runs of 6 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit 20 mm medium grade as per ISS and one run of 4 sqmm size earth wire PVC insulated copper conductor complete all as specified and directed.(Note Two runs of 6 sqmm copper FRLS cable & one run of 4 sqmm copper cable in and including 20 mm PVC conduit medium grade will be measured as one unit.
M&L in replacement for sub main wiring with 2 runs of 4 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit 20 mm medium grade as per ISS and one run of 4 sqmm size earth wire PVC insulated copper conductor complete all as specified and directed.(Note Two runs of 4 sqmm copper FRLS cable & one run of 4 sqmm copper cable in and including 20 mm PVC conduit medium grade will be measured as one unit.
Cutting chases, pinning in, including making good in cement mortar 1:3 including painting to match with the existing surface as in edges of landings, steps, cills, sunshades, shelves, lintels, etc; and for concealed conduit wiring, etc, cutting not exc 10 cm girth complete all as specified and as directed.
S&F in replacement Ceiling rose, PVC/ polycarbonate, isolated body type, three terminal, 240 volt, fixed in position & connecting complete all as specified and as directed.
S&F in replacement Bldg security light fitting LED 25 Watt, highly efficient IP66 LED, high power having aluminium pressure die cast housing and PC cover in the front and high power lens for batwing light distribution with electric connection with suitable size of PVC insulated copper wire including GI bracket 1.5 Mtr with clamps and bolts complete all as specified and directed.
Supplying, installation, testing & Commissioning of LED Post top 30 watt , I P65 elegantly designed spun aluminium and high grade aluminium , heat sink for efficient thermal managment , pole mounted posttop 30W with MS base provided to support the housing Power coated black treatment.
Supply, fixing and connecting in replacement recessed mounting back- lit LED 2X2, 36 watt tile in CRCA housing with full opal diffuser suitable for Armstrong/ Grid Ceilings Type, size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Total system Lumen not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed.
Supply, fixing and connecting in replacement of Slim LED Batten 10 watt with Surface/Wall Mounted integrated LED 2 feet Fitting Polycarbonate housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Total system Lumen of 10W Led should be 1000 or above in Cool day Light(6500K), Power factor>0.9, CRI (Ra) >80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed.
Supply, fixing and connecting in replacement of Slim LED Batten 20 watt with Surface/Wall Mounted integrated LED 4 feet Fitting Polycarbonate housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Total system Lumen of 20W Led should be 2000 or above in Cool day Light(6500K), Power factor>0.9, CRI (Ra) >80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed.
S & F PVC Ventillation Fan 250 mm sweep 240 Volt, 1325RPM , Air delivery 500 CMM connection with self closing louver frame flexible PVC copper wire from ceiling rose to exhaust fan including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed.
S & F Heavy Duty Metallic Exhaust Fan 300 mm sweep 240 Volt, 1400 RPM , Air delivery 500 CMM connection with self closing louver frame flexible PVC copper wire from ceiling rose to exhaust fan including provn of opening of hole on brick wall and grouting nut and bolt of suitable size complete all as specified and directed. Make:-Havells/ Usha/ CG /Bajaj
Supply & fixing of ceiling fan , 5 star rating (White colour) 230 V, 1200 mm sweep, speed 340 RPM , having rod length 300 mm complete all as specified and directed by Enggr in charge. Note:-Old unserveciable celling fan will be deposited to MES store yard.
S&F in replacement modular Fan step regulator, 120W - 2 module complete all as specified and as directed.
S&F in repair load line, distribution board, double door type, TPN, vertical, 8 way, suitable for accomodating upto 125 Amps MCCB with incomming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed.
M&L Earthing complete with galvanised Iron earth plate eletrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal grond level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Building at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate upto main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including execvation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
S & F in replacement for distribution board double door type, SPN, 8 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F in replacement MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and directed.
S & F in replacement MCB DP, 240 Volts, 63 Amps complete all as specified and directed.
S & F in replacement MCB SP, 240 Volts, 10 Amps complete all as specified and directed.
S & F in replacement MCB SP, 240 Volts, 16 Amps complete all as specified and directed.
S & F in replacement MCB SP, 240 Volts, 32 Amps complete all as specified and directed.
S & F in replacement MCB SP, 240 Volts, 63 Amps complete all as specified and directed.
S&F in replacement modular cover plate with frame, 1/2 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 8 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 12 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 1/2 modules complete all as specified and as directed.
S&F in replacement modular metal flush box , 3 modules complete all as specified and as directed.
S&F in replacement modular metal flush box , 6 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 8 modules complete all as specified and as directed.
S&F in replacement module metal flush box , 12 modules complete all as specified and as directed by Engineer-in-charge.
S&F in replacement Bulb holder, PVC/ polycarbonate, isolated body type , 240 volt, fixed in position & connecting complete all as specified and as directed.
M/S Rohit Enterprises (BID ID -3453990)
Vinay Shankar (BID ID -3454614)
M/s Verma and Co (BID ID -3453977)
V M CONSTRUCTION (BID ID -3458844)
M/S Yamin (BID ID -3454188)
Vipul Construction (BID ID -3459502)
J.P. Enterprises (BID ID -3453408)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
TENDERDOUCMENTD41.pdf
Tender Documents • 1.58 MB
BOQ_811346.xls
BOQ • 0.38 MB
corrigendum03.pdf
PDF • 0.19 MB
corrigendumno02.pdf
PDF • 0.19 MB
corrigendumd41.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .