Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC Due to lowest | |
| 2 | L2₹7.8 L+₹20,389 (2.68%)Rejected-Finance 261 3 BESIDE ROYAL HOSPITAL KAMLA NEHRU NAGAR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Due to being L2 | |
| 3 | L3₹8.4 L+₹80,570 (10.6%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L3 | Rejected-Finance Due to being L3 | |
| 4 | L4₹12.8 L+₹5.1 L (67.5%)Rejected-Finance | L4 | Rejected-Finance Due to being L4 |
| Sl No | Description | Qty | Unit | MISHON TRADING CORPORATION L2 | M/S Shanti Enterprises L3 | M/S INDIA ENTERPRISES L4 | AUTOMATION AND SWITCHGEAR PANELS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for re-winding of ceiling fan of 1200mm sweep comprising of the following works : (a) Opening of ceiling fan and removing of burnt copper winding and re-winding with equivalent super enameled copper wire incl varnishing heating and replacement of insulating materials as required. (b) Re-assembling including testing for satisfactory performance complete. (Note : Re-winding of fan and all repair works to be completed at MES store yard. Replacement of defective item shall be measured and paid under repective items as under herein after as supply only. | 150 | Each | 300 ₹45,000 Lowest | 350 ₹52,500 | 500 ₹75,000 | 450 ₹67,500 |
| 2.00 | All as per item No 1 above but for 1400mm sweep. | 60 | Each | 350 ₹21,000 Lowest | 400 ₹24,000 | 550 ₹33,000 | 500 ₹30,000 |
| 3.00 | All as per item No 1 above but for table / padestal /cabin fan 400mm sweep. | 4 | Each | 200 ₹800 Lowest | 300 ₹1,200 | 560 ₹2,240 | 400 ₹1,600 |
| 4.00 | M&L for overhauling of ceiling fan 1200mm sweep after complete opening and cleaning of all dust properly including greasing and replacement of connecting flexible wire as directed by Engr-in-charge. (Note : Overhauling of fan and all repair works to be completed at MES store yard and re-fixing/ hanging at site as directed. Defective item shall be measured and paid under repective items as under herein after as supply only. | 150 | Each | 30 ₹4,500 Lowest | 80 ₹12,000 | 150 ₹22,500 | 60 ₹9,000 |
| 5.00 | All as per item No 4 above but 1400mm sweep. | 75 | Each | 30 ₹2,250 Lowest | 80 ₹6,000 | 170 ₹12,750 | 90 ₹6,750 |
| 6.00 | M&L for painting of ceiling fan and fan blades in situ 1200mm sweep with one coat of synthetic enamel paint by spary painting after preparing of old painted surface of body blade, down rod including filling of cavities with filler as directed by Engr-in-charge. | 150 | Each | 20 ₹3,000 Lowest | 50 ₹7,500 | 90 ₹13,500 | 60 ₹9,000 |
| 7.00 | All as per item No 6 above but 1400mm sweep | 60 | Each | 30 ₹1,800 Lowest | 50 ₹3,000 | 120 ₹7,200 | 60 ₹3,600 |
| 8.00 | Taking down exhaust fan 230/300mm sweep from existing location for carrying out the following works :- (a) Opening of exhaust fan and removing of brunt copper winding and re-winding with equivalent super enamelled copper wire including varnishing heating and replacement insulating materials compelete. (b) Replacement of bearing and bushing and painting with one coat of synthetic enamel paint by spary painting after preparing of old painted surface of body blade, fitting arms including filling of cavities with filler as directed by Engr-in-charge. (c) Assembling and re-fixing of exhaust fan and complete testing for satisfactory performence (Note : Re-winding of exhaust fan and all repair works to be completed at MES store yard. Defective item shall be measured and paid under repective items as under herein after as supply only. | 20 | Each | 450 ₹9,000 | 350 ₹7,000 Lowest | 540 ₹10,800 | 500 ₹10,000 |
| 9.00 | All as per item No 8 above but 375/450mm sweep. | 5 | Each | 480 ₹2,400 | 400 ₹2,000 Lowest | 579 ₹2,895 | 450 ₹2,250 |
| 10.00 | Supply only AC film capacitor 2.5/3.15 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete. | 150 | Each | 30 ₹4,500 Lowest | 30 ₹4,500 Lowest | 45 ₹6,750 | 50 ₹7,500 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
20 Jun 2025, 6:00 pmClosed
AGE(I) PACHMARHI
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
REPAIR AND MAINT FAN, GEYSERS, ACS, WATER COOLERS, REFRIGERATOR WITH CONNECTED ITEM AT AEC TRG COLLEGE AND CENTRE PACHMARHI
2025_MES_703188_2
AGE(I)/PACH/of 2025-26(8717/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
E CLASS CATEGORY b(I)
7 documents required · 7 mandatory
₹500
Yes
AGE(I) PACHMARHI
₹18,000
Yes
9 Sept 2025
31 May 2025
23 Jun 2025
31 May 2025
20 Jun 2025
7 Jun 2025
Amount
M&L for re-winding of ceiling fan of 1200mm sweep comprising of the following works : (a) Opening of ceiling fan and removing of burnt copper winding and re-winding with equivalent super enameled copper wire incl varnishing heating and replacement of insulating materials as required. (b) Re-assembling including testing for satisfactory performance complete. (Note : Re-winding of fan and all repair works to be completed at MES store yard. Replacement of defective item shall be measured and paid under repective items as under herein after as supply only.
All as per item No 1 above but for 1400mm sweep.
All as per item No 1 above but for table / padestal /cabin fan 400mm sweep.
M&L for overhauling of ceiling fan 1200mm sweep after complete opening and cleaning of all dust properly including greasing and replacement of connecting flexible wire as directed by Engr-in-charge. (Note : Overhauling of fan and all repair works to be completed at MES store yard and re-fixing/ hanging at site as directed. Defective item shall be measured and paid under repective items as under herein after as supply only.
All as per item No 4 above but 1400mm sweep.
M&L for painting of ceiling fan and fan blades in situ 1200mm sweep with one coat of synthetic enamel paint by spary painting after preparing of old painted surface of body blade, down rod including filling of cavities with filler as directed by Engr-in-charge.
All as per item No 6 above but 1400mm sweep
Taking down exhaust fan 230/300mm sweep from existing location for carrying out the following works :- (a) Opening of exhaust fan and removing of brunt copper winding and re-winding with equivalent super enamelled copper wire including varnishing heating and replacement insulating materials compelete. (b) Replacement of bearing and bushing and painting with one coat of synthetic enamel paint by spary painting after preparing of old painted surface of body blade, fitting arms including filling of cavities with filler as directed by Engr-in-charge. (c) Assembling and re-fixing of exhaust fan and complete testing for satisfactory performence (Note : Re-winding of exhaust fan and all repair works to be completed at MES store yard. Defective item shall be measured and paid under repective items as under herein after as supply only.
All as per item No 8 above but 375/450mm sweep.
Supply only AC film capacitor 2.5/3.15 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete.
Supply only AC film capacitor 4.0 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete.
Supply only Ball bearing of ceiling / exhaust fan of suitable size and make as required with alignment of shaft and testing complete.
Supply only Self lubricating bush of gun metal of same type for ceiling fan / exhaust fan as required.
Supply only Shaft of approved quality for ceiling fan / exhaust fan any make any type & size as required.
Supply only Rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of suitable size and make as per site requirement
Supply only Ceiling fan down rod of 15mm GI pipe length of 4 ft with making thread and hole for hanging of fan complete with painting and hanging at site all as directed.
M&L for writing the MES number on ceiling fan / exhaust fan / table fan pedestal fan / cabin fan any size at site or in store all as specified and directed at site .
Taking down carefully storage type water heater (geyser) and capacity from clamp/bolts including disconnecting water and electric connection and re fixing the same and connecting up after cleaning of geyser and repair complete. (Note - Repair work shall be measured separately under respective items here-in after)
M&L opening up geyser of capacity 25/50 litre, checking defect, taking out u/s parts and re-assembling after carrying out repair / renewal work including nuts / bolts / wahers / gaskets / fusible plug etc wherever required and minor items not included separately in schedule. (Note - (Replacement of defective item shall be measured and paid under respective items herein after).
Geyser apparatus plate copper alloy chromium plated suitable for geysers 25/50 litre capacity including rubber gasket, nuts / bolts etc complete.
Heating element 1.5 KW, 230 volts, ISI marked suitable for 25 litre capacity geysers of any type as required.
Heating element 2.0 KW, 230 volts, ISI marked suitable for 50 litre capacity geysers of any type as required.
Heating element 2.0 KW, 230 volts, ISI marked suitable for 25 litre capacity geysers modular type with thermostate and socket as per sample and as required.
Thermostat ISI marked suitable for 25/50 litres geysers as required.
Neon lamp assembly with neon lamp green or red 230 volts any type for 25/50 litre geysers as required.
Geysers bottom or top cover metal of any colour as per site requirement including machine screws etc as per original size and shape of geyser 25/50 litre capacity as required.
Stainless steel inner tank suitable for 25 litre capacity geysers housing complete.
Stainless steel inner tank suitable for 50 litre capacity geysers housing complete.
SG insulation for 25 litre metal geysers as required.
SG insulation for 50 litre metal geysers as required.
Repair of inner copper tank of geysers 25/50 litre capacity with gas welding not exceeding 5 mm thick to make it leak proof complete.
Repair of apparatus plate of geysers 25/50 litre capacity by brazing not exceeding 5 mm thick complete.
S&F of brass chromium plated, flexible pipe connection 15 mm bore heavy duty suitable for hot water supply with two numbers brass chromium plated union at ends 450 mm long complete.
M&L for painting of geyser 25/50 litre with two coats of synthetic enameled white paint after removing old paint and preparation of surface and writing MES No (Letters height 10 cm) complete.
Supply and fixing of PVC insulated over all PVC sheathed single core copper flexible twisted cable of size 4.0 sqmm complete.
S&F water heater 25 litre capacity BEE star rating 5, vertical pattern in ivory colour, heating element 1.5 KW, connecting pioe, adjustable temperature setting knob for temperature settings between 250C to 750C, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insulation complete with hanging arrangement.
S&F in renewal 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required complete all as specified and directed.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FR-SH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into into including PVC casing-caping not less than 25x12 mm ISI marked of 2x4 sqmm + 1x4 sqmm earth wire complete all as specified and directed.
S & F in replacement of 15Amp Flug top Three Pin complete all as Specified and directed
Single pole 6 to 32 amp complete all as specified and directed.
S&F for high efficient LED Inverter/Charging Bulb 9 Watt, used as a ready replacement in B-22 holder complete all as directed. Make : Bajaj/ Havells/ Philips
Material and labour for disconnecting electric connection, taking down/ keep aside the air conditioner (Split/Window)/Water Cooler/Refrigerator including stabilizer of any make and capacity,servicing the same as cleaning inside, by mean of cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gaskit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and made functional the equipment fully and Re-installation in position and testing complete all as specified and directed by Engineer-in-charge. Note: (All new spare parts will be measured and paid separately under the respective items.)
M&L for detection and rectification of leakages in gas line by necessary brazing in 1.5 Ton/2.0 Ton window / split type AC of any model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts including charging of refrigerant gas R-32/ R 22/R-410 or any other refrigerant gas as required with appropriate quantity including testing for smooth functioning all as specified and directed. Note: Spare parts, if requited will be measured and paid separately under the supply of respective items.
M&L for detection and rectification of leakages in gas line by necessary brazing in Refridgerartor/ Water cooler of any capacity , model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts including charging of refrigerant gas R-134A or any other refrigerant gas as required with appropriate quantity including testing for smooth functioning all as specified and directed. Note: Spare parts, if requited will be measured and paid separately under the supply of respective items.
M& L for Dismantling of unserviceable/worn hermetically sealed unit compressor from Split type AC and replacement with new one compressor (company repaired), suitable for existing same model/make of capacity 1.5/2 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-32/R 22 in appropriate qty after making vacume the complete system and testing the A/C for proper functioning all as directed. .
Supply and fixing Cooling coil complete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Split type AC as per existing size and specification required in repairs of equipments mentioned against item No 1 here in above including dismantling, opening the equipments, assembling and testing complete all as specified and directed by Engineer-in-charge. Note : All the repairs shall ensured to be carried out at AGE (I) store yard including transportation of equipment and re-fixing at site.
All as per item No 5.00 above but condensing coil coplete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Split type AC as per existing size and specification
All as per item No 5.00 above but fan motor for water cooler upto 150 Ltr capacity.
All as per item No 5.00 above but fan blade suitable for AC's blower/ water cooler motor and all as per sample.
All as per item No 5.00 above but condensing coil suitable for water cooler upto 150 Ltr capacity copper as per existing make and model.
All as per item No 5.00 above but cooling coil suitable for water cooler upto 150 Ltr capacity copper madeas per existing make and model.
All as per item No 5.00 above but water outlet tap made of brass cromium plated for water cooler.
All as per item No 5.00 above but foam insulation heavy duty for ACs refrigerant line.
All as per item No 5.00 above but capilary tube for water cooler/ refrigerator/AC all as per exiting size.
S & F Starting/Running capacitor 80/100 mfd + / - 400 V AC, Suitable for 1.5/2.0 TR window / split type AC including taking down unserviceable old one complete all as specified and directed
S & F Over load Relay including taking down unserviceable old one.
S & F Thermostat switch ( DT 50-1052), suitable for 1.5 Ton/2 Ton split / window type AC including taking down unserviceable old one complete all as specified and directed
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per existing sample for indoor unit including taking down unserviceable old one complete all as specified and directed
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per existing sample for outdoor unit including taking down unserviceable old one complete all as specified and directed
Supply and Fixing Electronic Circuit plate (PCB) for Split/Window A/C 1.5 TR/2 TR including taking down unserviceable old one complete all as specified and directed
Taking out the unserviceable sealed compressor unit from water cooler and S&F New Sealed compressor unit company repaired of existing sample, suitable for 40/80 Ltr capacity of water cooler. replace with New compressor (duly tested)and checking the complete system for leak proof and including charging of refrigerant gas R-134 a in appropriate quantity and testing for smooth functioning complete all as directed.
Supply and fixing Running capacitor for Water Cooler having capacity 40/80 and 150Ltr as per existing sample including taking down unserviceable old one complete all as specified and directed
Supply and fixing over load Relay for Water Cooler having capacity 40/80 and 150Ltr including taking down old one complete all as specified and directed
Supply and fixing Float valve of 15mm dia non-metallic for Water Cooler having capacity 40/80 and 150Ltr including taking down old one complete all as specified and directed
Supply and fixing Float valve of 15mm dia non-metallic for Water Cooler having capacity 40/80 and 150Ltr including taking down old one complete all as specified and directed
M& L for replacement of relay, suitable upto 300/310 Ltr refrigerator of any make/model including taking down unserviceable old one complete all as specified and directed
Labour work for collecting split type/ Window type AC of 1.5 TR / 2 TR cooling capacity of any make/model from existing location /E/M store yard including installation of indoor and outdoor unit where as directed, making/breaking hole through the wall for and passing the suction/discharge line and PVC coduit of 25 mm dia n.exc.3.5 mtr long in concealed surface of wall for drainage of water occurs due to humidity, making good to disturbed surfaces with cement mortor of ratio1:3 finishing to match existing same and testing complete all as directed.
S&F wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5%and capacity of 05 KVA complete and taking out old all as specified and directed.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLSH PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one Note: Two run of single core FRLSH PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S&F MCB’s single pole, 10 KA , 32 Amp to 40 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs etc including taking down old one complete all as directed.
S&F MCB’s single pole and neutal, 10 KA ,32 Amp to 40 Amp 240 Volts,and of ''C'' series with required wiring connections and lugs including taking down old one complete all as directed.
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one single pole MCB of "C" series of cap 16-32 Amp including taking out the old one all as specified and directed.
M&L Metal clad Industrial plug top ISI mark 2 pin with earth 250 Volts including taking down old one complete as specified and directed.
M&L Metal clad Industrial socket ISI mark with earth 250 Volts including taking down old one complete as specified and directed.
M & L PVC insulated copper cable 3 core 40/ 0.0076, AC 1100/660 volt including taking down U/S cable complete all as specified and directed
MISHON TRADING CORPORATION (BID ID -3320307)
M/S Shanti Enterprises (BID ID -3320499)
M/S INDIA ENTERPRISES (BID ID -3321846)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .