Loading…
Loading…
Tender Value
₹4.9 L
EMD Value
₹10,000
Closing Date
8 Sept 2026, 6:00 pm
GE (AF) BKT
GE (AF) BKT, LUCKNOW
PROVISION OF AIR CONDITIONING AT CERTAIN LOCATION AT AF STN BKT
2026_MES_785286_1
8918/BKT/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹10,000
19 Aug 2026
19 Aug 2026
10 Sept 2026
19 Aug 2026
8 Sept 2026
2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation,commissioning and testing of hi wall split type air conditioner inverter type of capacity 1.5 TR (4500 k Cal/hr) single phase suitable for 230 V + 10 %, 50Hz AC supply complete with cordless remote control unit using Non CFC refrigerant Gas, 5 star rating and energy efficient complete as comprising of following :-
(a) indoor unit with three speed blower fan with motor of appropriate capacity including PCB,thermostatic control,air filter and drain for condensing water
(b) Outdoor unit comprising compressor ,air cooled copper condensor with fan and motor unit shall be installed outside the building / on roof
(c) Refrigerant copper pipe for suction and discharge line with insulation (up to 3.0 Mtrs) ,condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safty accessories including control wiring for evaporator & condensing Unit with suitable size of copper cable.
Make- Daikin/ O General/ Mitsubishi/ Hitachi
Note :- (i). Cutting holes in walls/window of any thickness with cutting machine for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .
(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate.
(iii) Refrigerant copper pipe for suction and discharge line with insulation beyond 3.0 Mtrs will measured and paid seperately. | 5 | Each | - | - |
| 2 | S & F Powder coated MS bracket/wall stand for fixing out door unit in wall or rooftop with necessary grouting MS hold fast, bolts etc complete all as specified and directed. | 5 | Each | - | - |
| 3 | Supply only of Copper Pipe of size 1/4"( with sleeves) | 5 | RM | - | - |
| 4 | Supply only of Copper Pipe of size 1/2"( with sleeves) | 5 | RM | - | - |
| 5 | S&F electronic wall mounted digital display(Input & output) voltage stabilizer for automatic voltage correction single phase, naturally air cooled, indoor type, mettalic body designed for input voltage between 140 Volt to 270 Volts and out put voltage 230Volt and High / low voltage cut off capacity 5 KVA complete all as specified and directed.
Make : V-Guard/ Volina/ Microtek/ Blue Bird/ Everest | 5 | Each | - | - |
| 6 | S& F Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete all as specified and directed. | 5 | Each | - | - |
| 7 | S&F Sheet metal enclosure SPN 4 way double door distribution board ,415 volt complete all as specified and directed | 3 | Each | - | - |
| 8 | S&F MCB SPN 63 Amps 240 volt,50 hz,10 KA breaking capacity "C" curved type complete all as specified and directed. | 3 | Each | - | - |
| 9 | S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. | 6 | Each | - | - |
| 10 | S&F Submain wiring with two single core PVC insulated FRLSH multistrand copper conductor cable of size 4 Sq mm drawn into and including non metallic heavy duty rigid concealed PVC conduit not less than 25 mm size ISI marked with all fittings / accessories and 04 Sq mm FRLSH multistrand copper conductor cable as continuous earth wire complete all as specified & directed.
Note :- (i). Cutting holes in walls/window of any thickness with cutting machine for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .
(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate.
(iii) Refrigerant copper pipe for suction and discharge line with insulation beyond 3.0 Mtrs will measured and paid seperately. | 90 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8918tenderdocuments.pdf
Tender Documents • 1.25 MB
BOQ_879951.xls
BOQ • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].