Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | ₹19.5 L Quoted ₹19.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.9 L+₹3.1 L (15.8%)Rejected-AOC | ₹22.9 L+₹3.1 L (15.8%) | L2 | Rejected-AOC L2 |
| 3 | L3₹26.8 L+₹7.0 L (35.7%)Rejected-AOC | ₹26.8 L+₹7.0 L (35.7%) | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹59,300
Closing Date
10 Apr 2021, 6:00 pmClosed
SH A P SINGH, IDSE, SE
HQ CWE CHANDIMANDIR
CA NO. CWE/CHM(U)-102/2020-21 COMPREHENSIVE MAINTENANCE OF FIRE ALARM, SMOKE DETECTION AND FIRE FIGHTING SYSTEM UNDER AGE EM-II OF GE (U) AT CHANDIMANDIR
2021_MES_430490_1
CWE/CHM(U)-102/2020-21
Open Tender
Miscellaneous Works
Item Rate
330 days
HQ CWE CHANDIMANDIR
Class D cat c(vi)
9 documents required · 9 mandatory
₹500
Yes
GE (U) CHANDIMANDIR
₹59,300
Yes
19 May 2021
13 Mar 2021
12 Apr 2021
13 Mar 2021
10 Apr 2021
27 Mar 2021
Amount
Servicing/Maintenance of fire alarm system Make:- Morley installed at War Gaming Centre complete all as specified and directed comprising following services/maintenance to be carried out under this item:- (i) Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii) The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primary power failure untill the alarm signal processed. (iv) Checking of audio amplifiers and tone genrating equipment (v)Checking of smoke detector sensibility. (vi) checking of all speaker circuit and loops. Note:- Work to be carried out in restricted area and the contractor shall get prior permision of DEPARTEMENT for work. .
Servicing/Maintenance of fire alarm system Make: Morley installed at COMPAD Building (Chanakya Bldg) complete all as specified and as directed comprising following services/maintenance to be carried out under this item:- (i) Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii) The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primary power failure untill the alarm signal processed. (iv) Checking of audio amplifiers and tone genrating equipment. (v) Checking of smoke detector sensibility. (vi) Checking of all speaker circuit and loops.
Servicing/Maintenance of of fire alarm system Make: Morley installed at HQ Western Command Building complete all as specified and directed comprising following services/maintenance to be carried out under this item:- (i) Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii) The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primary power failure untill the alarm signal processed. (iv) Checking of audio amplifiers and tone genrating equipment. (v) Checking of smoke detector sensibility. (vi) Checking of all speaker circuit and loops.
Servicing/Maintenance of fire alarm system Make: Morley installed at Maneakshaw audotorium complete all as specified and directed comprising following services/maintenance to be carried out under this item:- (i) Small spare parts as required (like wire,lugs,pvc caps,nuts and bolts etc.) shall be measured under this item. (ii) The work shall be executed by OEM or his authorised agency only as approved by GE. (iii) Checking of Alarm, signal should not lost when primary power failure untill the alarm signal processed. (iv) Checking of audio amplifiers and tone genrating equipment (v) Checking of smoke detector sensibility. (vi) Checking of all speaker circuit and loops.
Supply,Installation,Testing and Commissioning of analog addressable type self acclimatising multi sensing Photo and heat detector with standard mounting base,LED,Address switch,comlete with MS powder coated junction box for mounting on surface /on false ceilling/ below false floor, cable Lugs at ends,cable compression glands,cable tags and ferruling complete all as specified and directed. Make:- Morley/Honeywell/Notifier or equivalent approved make specified in Appx 'B'.
Supply,Installation,Testing and Commissioning of UL listed analog addressable dual action manual pull station/ glass break with address switch and all mounting accessories,,comlete with MS powder coated junction box for mounting on surface /on false ceilling/ below false floor, cable iugs at ends,cable compression glands,cable tags and ferruling complete all as specified and directed. Make:- Morley/Honeywell/Notifier or equivalent ISI/BIS make approved by GE.
Supply,Installation,Testing and Commissioning of addressable control module with address switch and all mounting accessories,comlete with MS powder coated junction box for mounting on surface,cable lugs at ends,cable compression glands,cable tags and ferruling complete all as specified and directed. Make:- Morley/Honeywell/Notifier or equivalent ISI/BIS make approved by GE.
Supply,Installation,Testing and Commissioning of,fault isolator module,complete with MS powder coated junction box for mounting on surface, cable lugs at ends,cable compression glands,cable tags and ferruling complete all as specified and directed. Make :- Morley/Honeywell/Notifier or equivalent ISI/BIS make approved by GE.
Supply & Fixing in replacement of hooter with all required accessories for mounting complete all as specified and directed. Make:- Morley/Honeywell/Notifier
Supply & Fixing inreplacement response indicator with matching screws complete with GI junction box etc complete all as specified and directed. Make:- Morley/Honeywell/Notifier or equivalent ISI/BIS make approved by GE.
Supply, Installation, Testing and Commissioning in replacement of UL listed with qwerty keypad networkable repeater panel having 640 character backlit LCD displays function keys and soft keys, Repeater panel should be on true peer to peer network complete all as specified and directed. Make:- Morley/Honeywell/Notifier or equivalent ISI/BIS make approved by GE.
Supply and fixing in replacement of 30 mtr hose pipe reel in red colour with capacity of minimum working pressure of 20 bar complete all as specified and directed. Make:- Morley/Honeywell/Notifier or equivalent ISI/BIS make approved by GE.
Supply, Installation, Testing and Commissioning inreplacement 1-5 Loop Control Panel 230Vac 4 sounder circuits , 4 line display and networking capability , 6 Amp PSU with 460 Ma loop capability 500*500*195 mm (H8W8D) including Mother Board with power Supply complete all as specified and directed. Make:- Morley/Honeywell/Notifier or equivalent ISI/BIS make approved by GE.
Supply, Installation,Testing and Commissioning in replacement Loop Driver Card suitable for 4 line display complete all as specified and directed.
Supply, Installation,Testing and Commissioning inreplacement RS 485 Communication Card complete all as specified and directed.
Supply, Installation,Testing and Commissioning in replacement Loop control module suitable for 4 line display complete all as specified and directed.
Supply, Installation,Testing and Commissioning in replacement loop expender module complete all as specified and directed.
Supply, Installation, Testing and Commissioning in replacement display card complete all as specified and directed.
Supply, fixing & testing in replacement of ZRLS cable of size 1.5 Sqmm 2 core sheathed including passing through exisiting conduit / exisiting route and necessary cutting and chessing of wall / roof for laying of cable and neceesary PCC work 1:2:4 type B0 for cutting surface with and including material the existing surface complete all as specified and directed.
Supply and fixing in replacement of battery 12V 7AH complete all as specified and directed.
Supply and fixing in replacement intelligent and addressable FSB-200 Series of the industry's most reliable smoke sensing technology Beam indicator with reflector complete set, FSB-200 Single-ended beam smoke detector Operating Temperature: –22°F to 131°F (–30°C to 55°C), FSB-200S Single-ended beam smoke detector with integral sensitivity test, Operating Temperature: –22°F to 131°F (–30°C to 55°C), 16 to 328 foot protection range, Single-ended, reflected type design, Paintable cover complete all as specified and directed.
S&F PVC Canvas Fire Hose Pipe, Dia 65 MM , length 12 mtr , with lining, Min pressure 0.8 Mpa, including 65 mm dia stainless steel male/female couplling complete all as specified and directed.
Supply and fixing in replcement MS pipe 80 mm dia bore including welding work complete all as specified and directed.
M&L for painting of pipe 80/100 MM dia bore MS pipe as per existing colour including preparation of surface complete all as specified and directed.
Supply and fixing in replacement 65 MM dia bore male/female Brass hose pipe coupling complete all as specified and directed.
Supply and fixing mother board of fire fighting 1-5 Loop Control Panel board complete all as specified and directed.
Supply and fixing 1 KVA/600 W Capacity UPS including battery overload protection , Electric surge protection , Voltage fluctuation protection and short circuit protection, Led indication , Audible alarm, AVR technology, 7 AH -02 Nos battery 12 Volt sealed Lead Acid battery ,output voltage 220 volt complete all as specified and directed make- Luminious, microtech or equivalent ISI/BIS make approved by GE.
M/L in replacement of Network Card of fire fitting panel of existing size , capacity and make completed all as specified and directed. Make:- Honeywell or equivalent ISI/ BIS make approved by GE.
Supply, Installation,Testing and Commissioning in replacement of Sensing Photo and heat wire less smoke detector, 3 V powered with inbuilt -in wireless transmitter with standard mounting base, LED, Address switch, comlete with MS powder coated junction box for mounting on surface /on false ceilling/ below false floor, cable Lugs at ends, cable compression glands, cable tags and ferruling complete all as specified and directed. Make:- Morley/ Honeywell/ Notifier or equivalent ISI/BIS make approved by GE.
Supply and fixing in replacement of wifi fire alarm panel, electro optical type, LCD display, alarm more than 90 DB, 3 phase, 1 loop complete all as specified and directed.
Supply and fixing in replacement of Hydrant valve single headed, 65 mm bore including flange, washer, and nut and bolt complete all as specified.
FORTUNE STAR
Continental Engineers and contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .