Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC ANANDA NAGAR PANDU PORT ROAD JALUKBARI GUWAHATI 01 | ₹1.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 Cr+₹1.8 L (1.00%)Rejected-AOC | ₹1.8 Cr+₹1.8 L (1.00%) | L2 | Rejected-AOC L2 |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
20 Jan 2025, 4:00 pmClosed
Superintending Engineer PWD, Kamrup Road Circle
O/o Superintending Engineer PWD (Roads), Kamrup Road Circle, Fancy Bazar,Guwahati-01
Construction of Madhuban Nagar Road of Ward No. 1 under SOPD-G For the year 2024-25.
2024_PWD_41271_2
No.GRC/NIT/510./2021 -22/Pt.I/ 2506 Dtd.09.12.2024
Open Tender
Civil Works – Roads
Item Rate
180 days
Jalukbari
Plesae refer tender
4 documents required · 4 mandatory
₹5,259
Yes
₹3.5 L
Yes
Kamrup Road Circle
11 Mar 2025
19 Dec 2024
21 Jan 2025
19 Dec 2024
20 Jan 2025
19 Dec 2024
19 Dec 2024 - 8 Jan 2025
27 Dec 2024
Amount
Road Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. V Marshy soil
Construction of embankment with approved material obtained from borrow pitswith a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compp g acting to meet reqquirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. A By Manual Means
Inter locking concrete Block pavement (A) Interlocking pavement block (i) Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. a) Including Edge block/ Edge restraints
Construction of RCC Load Bearing Drain
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil Upto 3 m depth
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A With crushed Stone I P.C.C grade M 10 Nominal mix 1:3:6
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A With Crushed Stone A With crushed Stone IV RCC Grade M 25 i) For height upto 5 m
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 ii Sandy material
Construction of Stone Masonry Retaining Wall
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil Upto 3 m depth
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings andtechnical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A With crushed Stone I P.C.C grade M 10 Nominal mix 1:3:6
Stone masonry work: Uncoursed rubble masonry work in all retaining wall, wing wall,abutement etc. in cement mortar 1;6 withoutside face stone roughly hammer dressed and inside (earthen side) undressed as per drawing and technical sopecifications including racking out joints and curing , supplying and carriage of stone as directed.
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification B Sandy material
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on RCC Post 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing Clause 1701 600mm x 450mm rectangular
Tubular Steel Railing on Medium Weight Steel Channel (ISMC series) 100 mm x50 mm Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 m high above ground, 2 m centre-to-centre, complete as per approved drawings Clause 1706
M/S USHA ENTERPRISE (BID ID -255675)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .