Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC ACCPETED | |
| 2 | L2₹49.3 L+₹2.1 L (4.49%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹50.3 L+₹3.0 L (6.43%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹52.0 L+₹4.8 L (10.1%)Rejected-AOC FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹55.2 L+₹8.0 L (16.8%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
15 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
REP AND MAINT AND DAY TO DAY PETTY MAINT AT AIR CRAFT HANGAR, ANEXX BLDG AND OTHER INFRA FOR B/R AND E/M ITEMS AND MAINT REPAIRS INCL JOINT FILLING FOR AIRCRAFT DISPERSAL AREA, SEWERAGE DISPOSAL SYSTEM AND OTHER MISC ITEMS AT NAVAL AVIATION SANTACRUZ
2023_MES_607059_2
8288/B
Open Tender
Civil Works
Item Rate
270 days
SANTACRUZ
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹96,000
Yes
11 Feb 2024
25 Aug 2023
16 Sept 2023
25 Aug 2023
15 Sept 2023
1 Sept 2023
Amount
Grinding the existing surface, cleaning the same and making it free from dust and dirt complete all as specified and directed.
Epoxy flooring :- Stage 1. Providing and applying one coat of Epoxy primer over grinned, clean and dry surface and let it dry for 8-10 hrs all as specified and directed. Make: K2P Chemicals or as approved by GE. Satge 2.Providing and applying epoxy self levelling screed of 2 mm thickness all as specified and directed. Make: BIS Approved
Providing and coating two coats of top coat using UV- Resistant Pu top coat of Make: BIS Approved over 2 mm thk screed complete all as specified and directed.
Material and labour for preparation of surface, 50mm depth of cutting damaged portion of PQC slabs 50mm depth such as edges of joints and cracks not less than 50mm on either side of edge of concrete slab, to remove all the damaged, loose and unsound concrete by the help of Electric / diamond tool cutter of appropriate geometrical size in order to have straight and smooth edges, inside of the cut concrete surface shall be made rough for proper mechanical anchorage and cleaned with hard wire brush to remove all loose particles and vacuumed cleaned to have a dry and dirt free surface, prior to mixing and placing the elastomeric concrete, prime the substrate coming in contact with the elastomeric concrete both vertical and horizontal surface should be primed with special primer (RDL 942 or equivalent) the material shall be applied using a paint brush and in a single coat. Elastomeric concrete, kits contain 3 kg of part A and 1.5 kg of part B with a 5.5 Kg.part of part C (E-Crete Aggregate) using a drill and spiral mixing paddle, pre-mix A & B components until uniform (approx 60-90 seconds) immediately remove contents from C and add to the above and continue mixing until no dry material appears one mixed, the material can be poured into the block out/hole while the primer is still wet the material is self leveling trowel finish as desired.(Make : Choksey/fosrac/STP Ltd/Pidilite/SIKA) Note :- 1. The quoted rate for the above item shall be deemed to include disposal of debris to the outside of MD Land. Curing of the repaired joints, removing of the thermocol and cleaning of the concrete surfaces etc complete all as directed by the Engineer-in-Charge. 2. The work shall be carried out through an authorised applicator of the company and certificate is required. 3. Due care shall be given to avoide any damage to the existing lighting system and any damage if happened, noted the same shall be rectified immediately to the satisfaction of GE.
Demolition of Cement concrete of any strength in ground floor and pavings (below or above ground level) and removal of debris to out side MD land upto 60 KM as per BMC guidelines , complete all as specified and directed.
M&L for 150 mm thick cement concrete type 1:3:6 ( 40mm graded aggregate) as in sub base including laying and levelling complete all as specified and directed.
Material and labour for cement concrete (RMC) of flexural strength 40 Kg/ Sqcm in field as per design mix (with maximum size of coarse aggregates upto 40mm), using minimum 400 Kg/cum of cement including triangular/non circular synthetic polyster fibre reinforcement @ 0.25% by weight of cement including form work for butt nosing, rounding off edges , curing , spread and compacted by using slip form paver complete all as specified and directed. Note: (i) The cost of admixture required as per design mix shall deemed to be included in the quoted rate (the constant shall be applied based on design mix). (ii) Polyster triangular/non circular synthetic fibres as secondary reinforcement mixed in concrete shall be measured and paid for separtely under respective item of this schedule. However, mixing shall be deemed to be included in the quoted rate (the constant shall be applied based on design mix). (iii) Construction joints, dummy (contraction joints) and expansion joints shall be measured and paid separately under respective items.
Supply only polyster triangular fibres /non circular fibres (Recron triangular fibre type CT 2012 12mm) having tensile strength 4000-6000 Kg/cm2, designed for melting point more than 250 degree celsius @ 0.25% by weight of cement in controlled pavement quality cement concrete and having specific gravity of 1.34 to 1.40 complete all as specified and directed.
Material and labour for finishing concrete pavement by brooming when concrete is green complete all as specifide and directed.
Providing sand cushion with clean river sand duly clear of residual , organic and deleterious materials spread evenly to uniform thickness laid over DLC layer/sub base complete all as specified and directed. (No additional amount to be paid for overlap)
Material and labour for high density polythene film (transparent colour) in single layer of 400 micron thickness of virgin quality (as per ASTM D 2103,IS-2508) laid with side and end overlapping not less than 150 mm complete all as specified and directed.
Material and labour for 7.5cm thick (compacted thickness) water bound macadam (WBM) ( granite, trap or basalt) with coarse aggregate of grading 2 (63 to 40mm size) or of grading 3 ( 50 to 20mm size) spread, rolled and consolidated to gradient and camber required complete all as specified and directed.
Repair of cracks of PQC 1 surface preparation cleaning the cracks that have been contaminated to the extent it is possible and practical and the surface should be cleaned and all the loose concrete if any ,of plaster which sounds hollow when tapped shall be removed ,contaminated such as oil grease , dirt or fine particles of concrete pavement , epoxy /bonding material which may reduce the effectiveness of the repair shall be removed as per the manufacture recmmendation. Ensure that crack area should not have any visible dampnessand must have surface moisture<4% 2. Fixing of Grouting Nozzle All the cracks must be wide and drill the holes of 6-10mm dia with atleast 50 - 75 mm into the concrete .the nozzles shall be placed at 500mm c/c using bostick ERM ,an epoxy repair mortar system having compressive strength of 95 MP a as per ASTM C109 ,Tensile strength 15 MPa as per ASTM C 307 and flexural strength of 30 Mpa as per ASTM C078 Ensure that the adhesive shall not block the drilled holes 3. Injection Grouting using Low Viscous Epoxy Resin grout system mix The two component low viscous , non pigmented liquid epoxy resin system bostik LVEP having final compressive strength of 70 MPa and curing time of 7 days , the epoxy resin system must be low viscous with high cpaollary action non shring and deep penetration with hard and abrasion resistant and shall be able to withstand loads and stress Injection of the epoxy grout shall be done from the farthest point towards the center keeping regular eyes for the next hole to avoid any wastage of material once the grouting is done and injected , eoxy is cured ,cut the nozzle and seal the holes with the bostic ERM system
M&L for Forming Construction joint 10mm wide & 30mm depth with mechanical cutter and filling with polyethyelene rod and 10mm deep with polyurethane joint sealant upto top surface (suitable for old rigid pavement) including applying suitable primer for proper bonding with polyurethane joint sealient ( suitable tape to be applied on both side of joint before sealing joints and remove after filling of joints) etc complete all as specified and directed. Make : Choksey/ STP/ Pidilite
Racking out damaged/deteriorated old sealing compound 16 to 30 mm wide & 40mm average depth of existing joints with air blower and filling with polyethyelene rod and top10mm deep with polyurethane joint sealient upto top surface (suitable for old rigid pavement) including applying suitable primer for proper bonding with polyurethane joint sealient ( suitable tape to be applied on both side of joint before sealing joints and remove after filling of joints) etc complete all as specified and directed. Make : Choksey/ STP/ Pidilite
Racking out damaged/deteriorated old sealing compound upto 15 mm wide & 30 mm average depth of joints with air blower and filling with polyethyelene rod and top 10mm deep with polyurethane joint sealient upto top surface (suitable for old rigid pavement) including applying suitable primer for proper bonding with polyurethane joint sealient ( suitable tape to be applied on both side of joint before sealing joints and remove after filling of joints) etc complete all as specified and directed. Make : Choksey/ STP/ Pidilite
M&L for preparation of old painted concrete surfaces (Rigid Pavement) over 10cm width or girth and apply two coats in 24 hour interval with water based road marking paints conforming to IS-164, 1981(Amended 1993) , fast drying, highly durable 100% acrylic retro-refective water borne paints applied with spray machine/roller to lines, dashes, arrows, letters etc & the like, exceeding 10cm wide with road marking paint & tint as approved & as specified (Painting shall be done by using wooden/plywood template at edges to be provided). First time painting of approved make.
All as per item No 19 above but one coat for second time painting for the same area after three months gap from first time painting complete all as specified and directed.
M&L for preparation of old painted surface and apply one coat of synthetic enamel paint (Shade of colouras per directions) for markings on brick, stone, concrete, plastered surfaces, complete all as specified and directed.
Supply and fix in repair stainless steel (SS-304) wind turbine air ventilator of 600 mm throat dia with capacity of 2700 cfm to be mounted on top of new FRP base plate of 2 mm thick with venture dome, including necessary cutting of existing roof sheets, sealing with watertight arrangements etc complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. Note :- Height of structure exc 10 mtr
M&L for dismantling plain or corrugated steel sheeting or galvalume sheet any gauge and thickness etc complete all as specified and directed.
S&F pre-coloured corrugated galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets as in roofing/wall cladding, 0.50mm thick (Total coated thickness), 0.45 mm ( base metal thickness )conforming to AS-1397/ASTM A-792 and having yield strength minimum 550 MPA fixed with hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washers and fixed as per manufacturers instructions complete all as specified and directed.
S&F pre-coloured plain galvalume (55% aluminium + 43.5% Zinc+ 1.5% Silicon) steel sheets, 0.50mm thick (Total coated thickness), 0.45 mm ( base metal thickness ) conforming to AS-1397/ASTM A-792 and having yield strength minimum 550 MPA fixed with hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washers and fixed as per manufacturers instructions complete all as specified and directed.
S&F 1 mm thick plane aluminium sheet in ridges hips, valley gutters, drip and straight flashings etc welded or soldered joints with grade of zinc coating 275 and necessary C type or J type hook bolts complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surfaces such as skirtings, dados etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick backing coat in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350x250x7mm / 450x350x7mm thick in vertical surfaces such as skirting/dado and jointed in neat cement slurry and pointed in white or coloured cement to match and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, complete all as specified and directed.
M&L for vertified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for vertified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in vertical surfaces such as skirtings, dados etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles complete all as specified and directed.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate as in kerb stone or mud stops, rounded or chamfered on edges, levelling course, haunching, coping and similar works including rounded or chamferred on edges and formwork etc all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames), exc 1.50 sqm but not exc 4.0 sqm each complete as directed
Taking down shutters of any description but exc 1 Sqm and n exc 2.00 Sqm complete all as specified and directed.
S&F for Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per spcification & drawing etc, complete all as specified and as directed.
S&F for Factory made solid PVC Moulded door shutter , 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm th. Moulded PVC sheet on the front face & 2mm plain coour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS etc, complete all as specified and as directed.
S&F 35 mm thick flush shutters, solid core construction, with block board core both faces panel covered with decorative face veneer with lipping complete all as specified and directed.
S&F standard aluminum section powder coded in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be as approved by GE). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
S&F aluminum anodised grill DG- 202 ( 10 mm x 8mm ) fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Supply only 4mm thick sheet figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etc complete all as specified and directed
Supply only 4.80mm thick ordinary quality plain not exc 0.5 Sqm each pane with including wooden/rubber beading or gasket for aluminium section complete all as specified and directed.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S&F stainless steel butt hinges, 100mm, medium weight complete all as specified and directed
Supply and fix extruded aluminium alloy handles, fabricated type of size 150mm in any position complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
S&F 250mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
Cutting and grooving of wall for fixing of pipe lines and after fixing of GI pipe line and making good of all cutting surfaces complete all as specified and directed.
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
S&F 20mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
S&F in repairs for 20mm dia fancy type chromium plated curtain rods with fixing fancy brackets, brass screws etc complete all as specified and directed
S&Fin repair plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete all as specified and directed..
S&F in repair brass chromium plated towel rail 20mm dia 'D' type 600mm long between flanges, of with and including chromium plated brass screws etc complete all as specified and directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and seat cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed..
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs counter sunk wash hand basin, vitreous china white of size 550x 400mm , 32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F in repairs CP concealed stop cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs brass Chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type complete all as specified and directed.
S & F in repairs Vitreous China Half stall urinal White complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, with brackets complete all as specified and directed .
S & F in repair 160mm bore PVC rain water pipe single socketed any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc including taking down and filling nail holes on the walls to prevent seepage and making good complete all as specifed and directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S&F 160mm bore PVC (SWR) bends any radius dimnishing pieces or tapers etc, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) tee of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles.complete all as specifed and directed
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
M & L for rendering 12 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth with sagol finish complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M&L for 15mm thick rendering(first coat) in CM 1:4 on external surface of wall mixed with water proofing compound and shall be scored to provide key for rough finishing coat. including necessary scaffoldings etc complete all as specified and directed Note:- WPC shall be measured and paid seperately.
Supply only integral water proofing compound.
M&L for preparation of new plastered surfaces of wall and two coats of oil bound distemper over a coat of average 1mm thick Birla putty complete all as specified and directed
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
M&L for complete removal of old decorated surfaces of wall and thereafter applying with roller Two coat of oil bound distemper including application of wall care putty (3mm thick) for smooth finish.etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying with roller one coat of oil bound distemper including application of putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying one coat of white wash complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old acrylic surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with Dr fixit crack filler or equivalent make and applying one coat of 100% antifungal acrylic paint of approved shade including necessary scaffolding work etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying with roller one coat of plastic emulsion paint including application of Putty for smooth finish.etc complete all as specified and directed.
S&F in repair 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
S&F in repairs 500 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed
S&F in repairs 1000 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed
S&F in repairs 2000 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed
M&L for post construction anti- termite traetment along the external wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes with cement morter 1:2 to match the existng floor etc complete all as specified and directed.
M & L for post construction anti - termit treatment at points of contact of wood work using chemical emulision (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
M&L for Acid resistant tiles 15mm thick vitreous ceramic unglazed set and jointed and pointed in chmical resistant mortar resin type in floor complete all as specified and directed.
Routine maitenance of sliding door shutter of following sizes the maintenance including the following all as specified and directed. (a) Dismantling of MS works of any description such as rollers pulleys, guides, bottom sliding tracks and corrugated sheets including necessary straightening of bends. (b) Refixing the serviceable accessories such as rollers, pulleys, guides, channels bottom sliding tracks corrugated sheets etc. (c) Replacement of unserviceable accessories such as rollers, pulleys, guides, channels bottom sliding tracks corrugated sheets etc. (d) Cleaning, oiling, greasing etc complete of all movable parts all as required at site (e) weldding work for , pulleys, guides, channels bottom sliding tracks etc.
Supply only MS accessories for sliding door shutter repair such as shaft , pully ,lath sheets ,cast iron wheels , iron pipe and plate,channels bottom sliding tracks etc complete all as specified and directed.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
Material and labour in repairs for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core drawn through and including surfaced on PVC casing capping of 20/25 mm complete with sunk iron pressed steel terminal box concealed in wall for fitting mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light point controlled by one switch all as specified and directed.
All as per item No 100 above but one 5 Amps switch socket combination on same board all as specified and directed.
All as per item No 100 above but one 5 Amps switch socket combination on Independent board all as specified and directed.
All as per item No 100 above but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
Material and labour in repairs for point wiring complete with 4 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core drawn through and including surfaced on rigid PVC conduit and conduit accessories of 20/25 mm complete with sunk iron pressed steel terminal box concealed in wall for fitting mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 4 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one socket for connecting water coolers/ AC complete all as specified and directed.
Supply and fix in repairs switch modular type 6 Amp one way, 1 module complete all as specified and directed.
Supply and fix in repairs switch modular type 16 Amp one way, 1 module complete all as specified and directed.
Supply and fix in repairs socket modular type 2/3 pin combined 6 Amp 2 module type complete all as specified and directed.
Supply and fix in repairs socket modular type 2/3 pin combined 6/16 Amp 2 module type complete all as specified and directed.
Supply and fixing in repairs ceiling fan electronic regulator stepped/socket type 120 watts AC 230 V complete all as specified and directed.
M & L for rewinding the exhaust fan of 300 mm sweep , cutting and taking out unserviceable winding and rewinding with the same gauge copper super enamelled winding wire including all insulating material required as per standerd practice , warnishing, drying, backing , etc complete all as specified and directed.
M & L for rewinding the Air circulator fan of 600 mm sweep, cutting and taking out unserviceable winding and rewinding with the same gauge copper super enamelled winding wire including all insulating material required as per standerd practice , warnishing, drying, backing , etc complete all as specified and directed.
M & L for rewinding the Ceiling fan of 1200 mm sweep , cutting and taking out unserviceable winding and rewinding with the same gauge copper super enamelled winding wire including all insulating material required as per standerd practice , warnishing, drying, backing , etc complete all as specified and directed .
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and bus bar complete all as specified and directed.
Supply and fixing in repairs MCB TP 25 to 63 Amp , 415 volts complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amp breaking capacity 10 KA,"C" Curve rating complete all as specified and directed.
Supply and fix in repairs MCB SPN 240 Volts 40 to 63 Amps breaking capacity 10 KA rating complete all as specified and directed.
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 20/25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 4.0 sqmm (FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 4 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. ( Note: Two run of 4 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring complete all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 20/25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. ( Note: Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Supply and fix in repairs MCCB 415 volts, 16 KA Three pole 63 Amps complete all as specified and directed.
Supply and fix in repairs MCCB 415 volts, 16 KA Three pole 100 Amps complete all as specified and directed.
Supply and fixing in repairs highly efficient high power multi LED flood fitting 150 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed.
Supply and fixing in repairs highly efficient high power multi LED bay fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed.
Supply and fixing in repairs recess mounted LED round shape flat panel 12 watt warm white/day light as per requirement with high efficiency PMMA diffuser and inbuilt driver including modification existing wiring/surface/ceiling to fix LED fitting complete all as specified and directed.
Supply and fixing in repairs square surface mounted LED flat panel 12 watt PDC aluminium housing and PMMA diffuser makes it a robust luminaire, with inbuilt driver including modification existing wiring/surface to fix LED fitting complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in stove enamelled steel conduit of 20/25 mm complete with sunk iron pressed steel terminal box for fitting mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one 5 Amps switch socket combination on independent board complete all as specified and directed.
Supply & Fixing LED Light fitting 20 watt 220 V AC Decorative Box type with driver holder including ted complete with housing and LED 20 watt with aluminium heat sink on back of led rod,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed.
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Approved make. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also provided by the contractor (iv) Copper strip upto 7.5 meters included above quoted rates.
M&L for secure/hanging of electrical LT XLPE/PVC cable/wires of any size on walls/ceiling/store houses with clamps, hooks, nuts , bolts, flexible pipe and other accessories for electrical hyiegen complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 22995.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
M/s Qureshi Construction Co
R J ENTERPRISES
DWARKESH STRUCT-CON
S R INFRASTRUCTURE
the bhimani group of companies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .