| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 181 SECTOR 3 RADHA PURAM ESTATE MATHURA GANESHRA ROAD MATHURA UTTAR PRADESH 281001 INDIA | MATHURA | UTTAR PRADESH | 281001 | Admitted-Finance |
| 2 | Admitted-Finance PUNE | PUNE | MAHARASHTRA | 410301 | Admitted-Finance |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
19 Oct 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIRECTOR IISER PUNE
IISER Pune Dr Homi Bhabha Road Pashan Pune
RESTORATION OF ELECTRICAL AND FAS SERVICE IN CHEMISTRY LABS AT IISER PUNE
2022_IISRP_717162_1
13/ IISER/PUNE/2022 23
Open Tender
Electrical Works
Works
150 days
IISER PUNE
As per NIT
3 documents required · 3 mandatory
₹1,180
DIRECTOR IISER PUNE
₹73,000
31 Oct 2022
11 Oct 2022
20 Oct 2022
11 Oct 2022
19 Oct 2022
11 Oct 2022
Amount
Please note that Quoted rates are inclusive of taxes,labor,transportation, royaltie etc. Nothing Extra shall be paid separtely.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm Width x 50mm depth x 2mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm Width x 50mm depth x 2mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 63 A, 4P, 30mA - - RPDB & UPS DB
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 32/40 A 4P, 30mA - - LDB
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 32/40A, DP, 30mA - for LDB + ELDB + RPDB
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TPN sheet steel enclosure on surface/ recess without MCB complete with connections, testing and commissioning etc. as required.
PVC RACEWAYS ( Along the wall) DLP U- PVC adaptable trunking : Supply & installation of surface mounted DLP U- PVC adaptable trunking raceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with removable covers, complete with necessary bends, suitable sized junction boxes, internal angle, external angle, flat 90 degree angle , end caps and tees,minor civil works if any etc, Complete. (For every 1mtr distance cable tag has to be provided for each circuit in the raceways - as more that 1C FRLS copper wire is required for 1 Circuit) PVC RACEWAYS ( Along the wall), DLP U- PVC adaptable trunking . Size: 105x 50mm PVC Raceways for Power & Data with above specifications 105x 50mm PVC Raceways
16 AMP SOCKET: Supplying and fixing following Modular socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required. (All switches and Sockets shall be spark proof type) 6 Pin 15/16 amp socket outlet
13 AMP SOCKET: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. (All switches and Sockets shall be spark proof type) 13 amp socket outlet
16 AMP Switch: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as requiredincluding connections, as required. (All switches and Sockets shall be spark proof type) 15/16 amp switch
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. (All switches and Sockets shall be spark proof type) 6 Module Box with faceplate & cover
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. (All switches and Sockets shall be spark proof type) 4 Module Box with faceplate & cover
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
LIGHT CIRCUIT WIRING : Wiring for circuit / submain wiring in concealed pipe below false ceiling (by chieseling the wall and covering with chicken mesh with rough plastering) / surface mounted. Including ISI mark PVC Conduit with 25mm DIa of 2mm thick with PVC insulated FRLS single core wires with colour code of following: 2 x 2.5 sqmm + 1 x2.5 sqmm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire For Raw power
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire For UPS power
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire For Raw power
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm dia conduit pipe (2mm) - Raw Power in Floor
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32mm dia conduit pipe (2mm) - Power
Supply of Recessed/Surface Mounted 1'x1' , 20 W LED Luminaire with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 1'X1' Luminaire. .Luminaire should be available in different Lumen Packs of 2000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. . Make Wipro / Crompton / Havell / Bajaj / Philips
ERECTION for Recessed/Surface Mounted 1'x1' , 20 W LED Luminaire on surface / on cable tray with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 1'X1' Luminaire. .Luminaire should be available in different Lumen Packs of 2000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. . Make Wipro / Crompton / Havell / Bajaj / Philips. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supply of Recessed/Surface Mounted 2'x2' , 40 W LED Luminaire with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire. .Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. . Make Wipro / Crompton / Havell / Bajaj / Philips
ERECTION for Recessed/Surface Mounted 2'x2' , 40 W LED Luminaire with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire. .Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT upto 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. . Make Wipro / Crompton / Havell / Bajaj. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supply of Recessed/Surface LED battern fitting , 40 W LED Luminaire with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with LED batten polycarbonate .Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. . Make Wipro / Crompton / Havell / Bajaj / Philips
ERECTION for Recessed/Surface LED battern fitting , 40 W LED Luminaire with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with LED batten polycarbonate ..Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT upto 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. . Make Wipro / Crompton / Havell / Bajaj. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required ( for Data cable ) 25 MM
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At field side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At Rackside side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Supply of 2meter length cat 6 patch cord with Rj 45 terminations on both ends as complete.
Relaying of existing Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire. Measurement will be done on actual relaying of submain wiring. Removing, shifting, storage of cable / wires with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Relaying of existing Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 3 X 4 sq. mm + 2 X 4 sq. mm earth wire. Measurement will be done on actual relaying of submain wiring. Removing, shifting, storage of cable / wires with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable.
Refixing of existing 1 to 8 module faceplate & base plate on DLP PVC trunking. Measurement will be done on actual reinstallation of faceplates on DLP trunking. Removing, shifting, storage of faceplates are in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unserviable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Refixing of existing 1 to 8 module modular board on DLP PVC trunking. Measurement will be done on actual reinstallation of modular board on DLP trunking. Removing, shifting, storage of modular board are in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unserviable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Refixing of existing module switches ( 5 to 16 A ) on DLP PVC trunking. Measurement will be done on actual reinstallation of modular switches on DLP trunking. Removing, shifting, storage of modular switches are in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unserviable. Wiring required for connecting switches to sockets are in scope of agecy. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Refixing of existing module sockets ( 5 to 16 A ) on DLP PVC trunking. Measurement will be done on actual reinstallation of modular sockets on DLP trunking. Removing, shifting, storage of modular sockets are in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unserviable. Wiring required for connecting switches to sockets are in scope of agecy. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Relaying of existing UTP 4 pair CAT 6 LAN Cable in surface/ recessed medium class PVC conduit as required.UTP 4 pair CAT 6 LAN Cable. Measurement will be done on actual relaying of UTP 4 pair CAT 6 LAN Cable. Removing, shifting, storage of cable / wires with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Reinstallaion of existing 150x 50 mm DLP trucking on surface incluidind removing, shifting, storage of all accessories of DLP PVC trunking. Measurement will be done on actual reinstallation of DLP PVC trunking. Removing, shifting, storage of DLP PVC trunking with all accessories is in scope of agency for this item. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Supply and installation of joints for PVC DLP trunking ( 105 / 150 mm x 50 mm Size DLP PVC trunking ). Make Legrand / MK.
Supply and installation of Left or right End cap for PVC DLP trunking ( 105 / 150 mm x 50 mm Size DLP PVC trunking ). Make Legrand / MK.
Supply and installation of flat angle / L bend for PVC DLP trunking ( 105 / 150 mm x 50 mm Size DLP PVC trunking ). Make Legrand / MK.
Supply and installation of internal angle / corner for PVC DLP trunking ( 105 / 150 mm x 50 mm Size DLP PVC trunking ). Make Legrand / MK.
Supply and installation of External angle / corner for PVC DLP trunking ( 105 / 150 mm x 50 mm Size DLP PVC trunking ). Make Legrand / MK.
Removing, shifting, store of exisitng 2'x2' light fittings along with wires, mounting , screws etc as complete. All removed out material will be handedover to IISER Pune with invertary. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Removing of exisiting armoured cable from surface/ cable tray. Shifting, store of cable in same campus is in scope of agency. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately. For DB cable / power cable / fume hood cables / fume hood communication cable / fire detector cable ( Upto 35 sqmm )
Supply, installation, testing and commissioning of Start-Stop switching station having following specification. Specifications a ) Standard Start Push button with NO contact B) Standard Stop Push button with NC contact c) Emergency stop push button with Mashrrom head, self holding mechanism, Red top and yellow base, d ) PVC enclosure box with termination entry on each wall which is suitable for PVC / SS gland , Size of enclouser box 150 mm ( W ) x 100 mm ( H ) x 50 mm ( D) minimum. , wall mounting / surface mounting. e ) all Switches, Push buttons and enclosure boxes should be clearly labeled as per site requirement and colour code for each should be followed. Approval for sample component , arragement, GA etc are required from IISER Pune authorities.
Supply of 6 core x 1.5 sqmm , copper conductor, armoured cable, 1.1 KV grade, FRLS cable , Make Polycab / finolex / RR. ( For fume hood OG starter feeder to Push button station )
Laying of one number PVC insulated PVC sheated /XLPE power cable of 1.1 kv grade of following in the existing open duct/cable tray / on surafce as requied :- Upto 35 Sq mm Quoted rates shall be including all taxes,duties,royalties,lead,lift,transpotation,GST etc complete.Nothing shall be payable separtely. Work shall be executed as per direction of engineer in charge,IISER Pune. Actual cable laid at site shall be measured for payments.
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 6 Core x 1.5 Sqmm Armoured Copper Cable.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Removing, shifting and reinstallation , testing and commissioning of existing Rate of Rise Heat Detectors (Thermal Detectors): GRADE‐I Addressable analogue type Heat Detectors with solid state design with sensing element combination of fixed type and rate of rise of temperature indicating LED, mounting base etc. on surface with required accessories, as complete.
FIRE ALARM SYSTEM: SMOKE DETECTOR: Supply, Installation, Testing and Commissioning of Addressable analogue MUTISENSOR type smoke detectors with dual chamber, solid state design, indicating LED, mounting base etc. as per detailed specification. The rate shall inclusive of necessary base box, connecting glad for above detectors
Removing, shifting, reinstallation, testing and commissioning of Addressable analogue MUTISENSOR type smoke detectors with dual chamber, solid state design, indicating LED, mounting base etc on surface. as per detailed specification. The rate shall inclusive of necessary base box, connecting glad for above detectors.
Removing, reinstallation, Testing and Commissioning of existing Hooter with relay module and storb light with minimum 85 db audiable and control relay module,24V DC power supply units etc
MANUAL CALL POINTS :Supply, Installation, Testing and Commissioning of Manual call points pull stations of approved make with NO/NC contacts slim type and projecting out from the surface of enclosure with glass suitable for addressable function
CABLES / WIRES :Supply and fixing of 2 C x 1.5 sqmm armoured copper FRLS cable in celling with suitable clamps and screws (RED colour)
Supply, Installation, Testing and Commissioning of Supply & Laying of 2 core twin twisted 48/0.2 ATC, Multi strand, over all armored speaker cable as specified in the Tender Specifications
Suvarna Electricals Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .