Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹33.8 L+₹3.0 L (9.75%)Rejected-Finance 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹34.4 L+₹3.6 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | VIJAYALAKSHMI ENTERPRISES L3 | pmv.enterprises L2 | M/s Omm Muruga Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00PROVISION OF DMO ROOM | ||||||
| 2.00 | Site Clearance and Surface dressing not exe 15cm deep and getting out in soft/loose soil incl cleaning away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and tress not exceeding 30cm girth and removing rubbish upto a distance 50m outside the periphery of the area under clearance all as specified and as directed. | 79 | Sqm | 40 ₹3,160 | 63 ₹4,977 | 29 ₹2,291 Lowest |
| 3.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose type of soil complete all as specified and directed. | 25 | Cum | 350 ₹8,750 | 360 ₹9,000 | 300 ₹7,500 Lowest |
| 4.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m in depth and getting out in soft/loose type of soil complete all as specified and directed. | 1.5 | Cum | 450 ₹675 | 360 ₹540 | 300 ₹450 Lowest |
| 5.00 | M & L for Plain Cement Concrete in foundation (1:4:8) Type D2 using 40 mm graded stone aggregate as in foundation and mass filling complete all as specified and as directed. | 2 | Cum | 6,000 ₹12,000 | 5,400 ₹10,800 | 4,999 ₹9,998 Lowest |
| 6.00 | Treating the back fill in contact with foundation at the rate of 7.5 liter of emulsion per square meter of vertical surface (Area of the sub structure in contact with back fill to be measured) all as specified and as directed. | 12 | Sqm | 200 ₹2,400 | 180 ₹2,160 | 65 ₹780 Lowest |
| 7.00 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified and as directed. | 30 | Sqm | 150 ₹4,500 | 180 ₹5,400 | 45 ₹1,350 Lowest |
| 8.00 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and as directed. | 20 | Sqm | 150 ₹3,000 Lowest | 180 ₹3,600 | 160 ₹3,200 |
| 9.00 | Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and as directed. | 25 | RM | 99 ₹2,475 | 72 ₹1,800 Lowest | 75 ₹1,875 |
| 10.00 | M & L for Reinforced cement concrete (Design Mix) M-30 Grade (using 20mm graded stone aggregates) as in Foundations, rafts, footing foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed . | 7 | Cum | 9,000 ₹63,000 | 9,900 ₹69,300 | 5,500 ₹38,500 Lowest |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
9 Sept 2025, 6:00 pmClosed
Garrison Engineer, Avadi
Garrison Engineer , Muthapudupet, Air Force Area, Avadi, Chennai-55
SPL REPAIRS AND CONVERSION OF LT OH LINES TO UNDER GROUND CABLES AND ALLIED WORKS FROM GUARD POST NO 06 TO 10 AT PERIMETER AREA AND PROVISION OF DMOW ROOM WITH ATTACHED TOILET AND BATHROOM AT MH AREA AND PROVN OF PARKING SHED NEAR STATION ARMOURY UND
2025_MES_726743_1
8306/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Avadi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹73,000
9 Dec 2025
20 Aug 2025
11 Sept 2025
20 Aug 2025
9 Sept 2025
28 Aug 2025
20 Aug 2025 - 25 Aug 2025
Amount
PROVISION OF DMO ROOM
Site Clearance and Surface dressing not exe 15cm deep and getting out in soft/loose soil incl cleaning away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and tress not exceeding 30cm girth and removing rubbish upto a distance 50m outside the periphery of the area under clearance all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose type of soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m in depth and getting out in soft/loose type of soil complete all as specified and directed.
M & L for Plain Cement Concrete in foundation (1:4:8) Type D2 using 40 mm graded stone aggregate as in foundation and mass filling complete all as specified and as directed.
Treating the back fill in contact with foundation at the rate of 7.5 liter of emulsion per square meter of vertical surface (Area of the sub structure in contact with back fill to be measured) all as specified and as directed.
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified and as directed.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and as directed.
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and as directed.
M & L for Reinforced cement concrete (Design Mix) M-30 Grade (using 20mm graded stone aggregates) as in Foundations, rafts, footing foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed .
M & L for Reinforced cement concrete (Design Mix) M-30 Grade (using 20mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed .
M & L for Reinforced cement concrete (Design Mix) M-30 Grade (using 20mm graded stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed .
M & L for Reinforced cement concrete (Design Mix) M-30 Grade (using 20mm graded stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like chajjas complete all as specified and as directed.
M & L for Flat Form work to sides of concrete foundations, foottings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar works; vertical or to batter for rough finished surfaces complete all as specified and directed .
M & L for Flat Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and directed .
M & L for Flat Formwork to sides of columns square or rectangular or Polygonal in section rough finish surface of concrete complete all as specified and directed .
M & L for Flat Formwork to Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed .
M & L for MS TMT bars 10mm dia and over out to length, bent to shape required, including cranking, bending including necessary welding as required & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with the clips all as specified and as directed.
M & L for MS TMT bars 6mm to 8mm dia. out to length, bent to shape required, including cranking, bending including necessary welding as required & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with the clips all as specified and as directed.
Ditto all as per item No 19 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders/tempreture bar etc including other works all as specified and as directed.
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Modular bricks in cement mortar CM 1:6 including curing,racking of joints etc. complete all as specified & as directed.
M & L for rendering 15 mm thick cement plaster in CM (1:6) on fair faces of brick work or concrete surfaces and to be finished even and smooth (without using extra cement) complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in CM (1:4) on other than fair faces of brick or concrete work surfaces to be finished even and smooth (without using extra cement) mixed with integral water proofing compound all as per manufacturer's instruction and as specified. Note: (i) WPC shall be measured and paid for separately as 'Supply only'.
M & L for rendering 5 mm thick cement plaster in CM (1:3) on ceiling or concrete surfaces and to be finished even and smooth (without using extra cement) complete all as specified and directed.
Supply only liquid waterproofing compound complete all as directed.
M & L for preparation of newly plastered wall surfaces and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and as directed.
M & L for Preparatoin of newly plastered surfaces walls and applying two coats of oil bound distemper over priming plastered & other surfaces with Chalk whiting on plastered surfaces, preparatory to distempering complete all as specified and as directed.
M & L for Preparatoin of newly plastered surfaces ceiling and applying three coats of white wash on plastered ceiling surfaces, complete all as specified and as directed.
M & L for cement concrete type C-2, 1:3:6 (40mm graded aggregate) 100mm thick in sub base complete all as specified and as directed.
M & L for cement concrete type C-2, 1:3:6 (40mm graded aggregate), 75mm thick. as in plinth protection finished even and smooth without using extra cement including expansion joints complete all as specified and as directed.
M & L for hard core gauge n.exc 63mm broken stone deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces all as specified and as directed.
Filling under floors by earth obtianed from excavation / bring from out side including spreading,levelling & ramming excavated earth in layers n.exc 25 cm thick all as specified and as directed.
Returning, filling in incl spreading, levelling, watering and well ramming in layers nexc 25cm with soil into excavated trenches complete all as specified and directed.
Removing the excavated soil to a distance not exceeding 50 metres away depositing where directed at a level not exceeding 1.50 metres above the starting point complete all as specified and directed.
M & L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and C M 1:6 Screed bed or bedding layer of mortar 15mm thick for laying floor finishes complete all as specified and as directed.
M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm,n vertical surfaces such as skirtings, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and rendering 10 mm thick in CM (1:4) on fair faces of brick work complete all as specified and as directed.
M & L for Non - skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and C M 1:6 Screed bed or bedding layer of mortar 15mm thick for laying floor finishes complete all as specified and directed.
M & L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm / 450X 350X 7mm / 300mm x 450mm x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles and rendering 10 mm thick in CM (1:4) on fair faces of brick work complete all as specified and directed.
M & L for screed bed of mortar 15 mm thick in cement mortar 1:4 for laying APP membrane and including mixing water proofing compound as per manufactureres instructions complete all as specified and directed. Note :- Water proofing compound shall be measured and paid for separately under appropriate item of Sch "A' as supply only.
M & L for brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and directed.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles and applying one coat of bituminous primer @ 200 gms per sqm and then laying 3 mm thick APP modified bituminous membrane weighing not less than 3.50 kg/sqm reinforced weighing not less than 160 gms/sqm laid by torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints and changes should covered with CM 1:3 with water proofing chemical as per manufacturer's instructions and cured well before laying membrane etc and applying aluminium paint @ 100 gram / sqm on roof or vertical surfaces complete all as specified and as directed.
Supply & fix of sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty in square n exc 0.5 Sqm in each pane and sheet glass is ground or obscured or frosted, on one side complete all as specified and directed.
S & F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings all as specified and as directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass / stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
S & F of 50 micron coloured powder coated aluminium decorative grill design No DG-117,10 mm thick including F Sections complete all as specified and directed.
Supply and fixing of solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rai ; Panelling of plain colour PVC sheet 5 mm thickness to be fitted in MS frame welded/sealed to the style and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed.
Supply and fixing of butt Hinges, medium weight, mild steel, 100 mm size complete all as specified.
Supply and fixing of 150 mm long aluminium anodised, barrel tower bolt of extruded section and fixed all as specified and directed.
Supply and fixing of aluminum handles cast type, anodized of 150 mm size complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified & directed of following sizes :-(a) 16 mm bore
All as per item no 53.00 here in before but for 20 mm bore
Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good ,cutting n, exc. 10cm girth complete all as specified and directed.
S & F of Vitreous China wash down water closet pan (Pedestal pattern) white,including trap and connection to drain and flushing pipe (excluding flushing cistern) including seat cover with flat bottom and mild steel chromium plated or aluminium hinging devices for pedstal pan complete all as specified and as directed.
S & F of vitreous China wash basin white, flat back, size 630 X 450 mm excluding taps, waste, chain and plug and porcelain stopper including brackets and cutting for pinning in ends of brackets or erecting stand and including 32mm discharge pipe bore dia of Waste coupling of PTMT coupling (half or full threaded) (Minimum weight of 45gms) complete all as specified and directed.
S & F of 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed.
S & F of PVC connection 15mm size PTMT nuts of length 450 mm all as specified and as directed.
S & F of 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions all as specified and as directed.
S & F of 15 mm bore fancy type concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions all as specified and as directed.
S & F of 15 mm bore fancy type bib taps long body cast copper alloy chromium plated, screwed down, screwed for iron pipe or for brass ferrule.
S & F of 15 mm bore, brass chromium plated, fancy type health faucet with SS connection pipe 1.5 mtr long complete all as specified.
S & F of CP soap dish complete all as specified and directed.
S & F of acrylic shelf having size of 56 cms x 13 cms with chromium plated bracket below WHB mirror complete all as specified and directed.
S & F of grating round 150mm size of PTMT (minimum 100 gms) complete all as specified and as directed.
S & F of 15 mm bore pillar taps cast copper alloy,with capstan heads,chromium plated,screwed down, fancy type, high pressure, with or without lettred 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and as directed.
Supply and fixing of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed.
Supply and fixing of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed.
Supply and fixing of PVC (SWR) junction single, (single T) equal or unequal provided with access door suitable for 110mm bore PVC pipes complete all as specified and as directed.
Supply and fixing of PVC (SWR) bends any radius suitable for 110mm bore PVC pipes with access door complete all as specified and as directed.
Supply and fixing of PVC (SWR) bends any radius suitable for 75mm bore PVC pipes with access door complete all as specified and as directed.
Supply and fixing of PVC (SWR) vent cowl for 110mm bore PVC pipes complete all as specified and as directed.
Supply and fixing of PVC (SWR) WC connector bent type for 110mm bore PVC pipes complete all as specified and as directed.
Supply and fixing of PVC (SWR) for 75mm Diameter of outlet floor trap, plain with grating including jointing with solvent cement etc complete all as specified and as directed.
Supply and fixing of PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed.
S & F of Rotational moulded polyethylene multilayer water storage tanks (cylinderical vertical with closed top) 500 litres capacity, hoisted and fixed in position with and including all fittings and fixtures complete all as specified and directed.
S & F of Ball brass valves of Bore dia of pipe 20mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in complete all as specified and directed.
M & L for hard core gauge n.exc 63mm broken stone deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces all as specified and as directed.
M & L for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) 100mm thick in sub base complete all as specified and as directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m in depth for foundation, for laying / taking down sewage / water supply lines, forming bottom surfaces to required slpoe & gradient and not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/loose type of soil complete all as specified and directed.
M & L for Plain Cement Concrete in foundation (1:4:8) Type D2 using 40 mm graded aggregate as in foundation and filling mass filling complete all as specified and as directed.
M & L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) as in coping and finishing the exposed surfaces even and smooth by using extra cement including necessary form work complete all as specified and directed.
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Modular bricks in cement mortar 1:6 including curing,racking of joints etc. complete all as specified & as directed.
M & L rendering 15 mm thick cement external plaster in CM 1:4 on fair faces of brick/concrete work surfaces mixed with integral water proofing compound all as per manufacturer's instruction and all as specified and as directed. Note: (i) WPC shall be measured and paid for separately as 'Supply only'.
Supply only liquid waterproofing compound complete all as directed.
M & L for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in benching of surface channels/manholes including fair finishes of surfaces chamfering, throating and weathering and necessary form work complete as specified and directed.
Returning, filling in incl spreading, levelling, watering and well ramming in layers nexc 25cm with soil into excavated trenches all as specified and as directed.
Removing the excavated soil to a distance not exceeding 50 metres away depositing where directed at a level not exceeding 1.50 metres above the starting point complete all as specified and directed.
Supplying & fixing, jointing and testing reinforced concrete drain pipes 150 mm bore, class NP-2, laid and jointed with collar in CM 1:1 complete all as specified and directed.
M & L for concrete bed to drain pipes in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) including packing under and hauching against the side of the pipes after they are laid tested for pipes of 150 mm dia complete all as specified and directed.
M & L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC 1:2:4 type B-2 (using 40 mm graded stone aggregates) smooth finished, and reforming benching as required for 150mm dia of pipe complete all as specified and directed.
M & L for pre-cast cement concrete manholes covers in RCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) with duly engraved "MES" marking and placing in position and set in CM 1:4 complete all as specified and directed.
M & L for mild steel TMT bar 10 mm dia and over as in reinforcement cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L for point wiring with 1.5 Sqmm (nominal area) PVC insulated,FRLSH unsheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 25mm dia and its accessories concelaed type etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall/steel structure with 3 mm thick laminated hylam sheet top cover all as specified and as directed. for One light point controlled by one switch.
All as per item no 99.00 here in before but for One fan point controlled by one switch.
All as per item no 99.00 here in before but for One 3 pin 5 amps socket point on same board
All as per item no 99.00 here in before but for One switch socket outlet 3 pin 5 Amps on independent board.
All as per item No 99.00 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board and industrial socket complete all as specified and as directed.
S&F switch piano, flush type single pole, one way 5 Amps complete all as specified and as directed.
S&F switch socket 3 pin 5 amps , multi pin , flush type,complete all as specified and as directed.
S&F Switch socket 3 pin 15 Amps, multipurpose, flush type complete all as specified and as directed.
M&L ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed.
S&F electronic fan regulator, flush type phenolic laminated sheet etc as required all as specified and as directed.
Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete with emergency LED lamp 12W capacity complete all as specified and as directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40-63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
S&F MCB DB SPN 12 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
LED batten fitting 20/22 W, 230 V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed.
S&F LED building security light fitting 25W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to Bldg etc complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, suitable down rods, electronic fan regulator and fixing accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and as directed.
S & F Ventilation fan 200mm sweep, Power 22 W, Operating voltage 230 Volts with louvers and shutters plastic body type with all accessories and connecting up with suitable size 1 sqmm three core copper conductor flexible wire,screws,gutties complete all as specified and as directed.
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed .
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B of size 230x115x75mm for cable protection all as specified and as directed..
Laying of fine seived excavated soil including spreading, levelling, punning for cushioning of cable all as specified and as directed.
Supply & Lay cable XLPE insulated screened PVC bedded, gaivanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor extruded PVC Type ST2 Outer sheathed, 650/1100V as per IS 7098(part-I) of size 2 core 16 sqmm complets all as specified and as directed.
Supply & lay GI pipe light grade including necessary fittings of 25 mm bore complets all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading levelling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Supply and laying of CPVC pipe of size 25 mm bore(Inner Dia) , Grade SDR 13.5 (Class 2) with ISI mark including all fitting and fixtures like coupler, male adapter plastic threaded, reducing male adapter plastic threaded, union, frame adapter plastic threaded etc laid in trenches/walls/roof/floor etc all as specified and as directed .
Cutting the existing pipe line 80mm dia and insert tee for 80x80x25mm including necessary earth works and GI fittings etc all as specified and as directed .
Supply and fix CPVC Ball valve with brass threaded of size 25 mm bore(inner dia) , grade SDR 13.5 (class 2) with ISI mark complete all as specified and as directed.
GUARD POST NO 06 TO 10
Dismantling old unserviceable ACSR conductor of assorted sizes as in overhead lines from poles and taken on credit complete all as specified and as directed.
Dismantling old unserviceable cross arms of mild steel channel or angle sections etc from poles and taken on credit complete all as specified and as directed. Note: The porcelain insulators shall also be dismantled alongwith the conductors and taken on credit.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and directed :-(a) 10 sq mm 2 core
All as per item no 137.00 here in before but for 16 sq mm 4 core
All as per item no 137.00 here in before but for 25 sq mm 3.5 core
All as per item no 137.00 here in before but for 50 sq mm 3.5 core
Dismantling old unserviceable electrical poles of any type/size incl demolition of PCC work complete and taken on credit complete all as specified and as directed. Note: The porcelain insulators shall also be dismantled alongwith the conductors and taken on credit.
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) complete with painting of pole & one coat of black and yellow alternative strips 05 Nos, each strip 30 cm up to 1.5 mtr from bottom and painting all as specified and directed. (Note: Necesssary earth work, PCC work shall be measured and paid separately under relevant items)
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying in trenches fine sieved excavated dry soil including spreading/ leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B size for cable protection all as specified and as directed.
Material and labour for GI tubing light grade 50 mm for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified and as directed.
M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed.
M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed.
M&L for PCC (1:3:6) type C1, (using 20 mm graded aggregate) as in foundations, for coping, filling and mass concrete with cement plastering finishing all as specified and directed.
Supply and fix LED building security street light 60 W, made up of pressure die cast housing with toughed glass and individual high power LEDs with secondary optics, IP66 protection incuding drivers, connecter block etc complete pre wired complete all as specified and dirtected
M&L for street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed complete all as directed and specified .
Material and labour for 1100 volts grade heavy duty cable PVC insulated , PVC sheathed,fire resistant, round ,copper conductor, 3 core industrial cable of size 1.50 sqmm including taking down the old one complete all as specified and as directed.
Supply and Fixing of pole mounted Sheet Moulded Compound(SMC) Box weather proof type with hinged type door off white color of Size 300x200x100 mm comprising of 1 No MCB 6A and 4 rows with terminals with bolt and nut and connecting up cables with aluminium terminal lugs complete fixed on pole with suitable clamps, bolts and nuts including taking down the old one complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 3.15mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised iron strip 25×4mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) all as specified and directed.
Supply.install,testing and commissioning of cubical outdoor LT Electrical distribution feeder pillar box CPRI approved platform mounted factory made totally enclosed dust and vermin proof (protection class IP-65) double shutter front opening with locking arrangement complete made of 1100mm x 1000mm x 600mm thick frame work and 3.15mm thick CRCA sheet duly painted over outside and inside with detachable sheets with holes for cable glands,separate bus bars,cable entry and exit mounted on PCC pillers with bolts grounted complete .The panel comprising of Aluminium bus bars of 550A capacity,415 volt 50Hz,3 phase 4 wire system with insulators and internal wiring complete with following requirements :- INCOMING:- MCCB,125 Amp 4 pole, FE Frame,Ics=100% of Icu, 36 KA breaking capacity with adjustable Microprocessor release - 01 No OUTGOING:- MCCB,63 Amp 4 pole, FE Frame,Ics=100% of Icu, 16 KA breaking capacity with adjustable Microprocessor release - 02 Nos MCB DP 40-63 Amps - 03 Nos Street light control system 40 amps 3 phase power contactor, control with photosensitive system - 01 No Indicating Lamp LED Type - 01 set Multifunction meter digital type -01 No
PROVN OF PARKING SHED NEAR STATION ARMOURY
Excavating in post holes each not exc 0.5 Cum getting out hard and dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate in bed plates in foundations etc.all as specified.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W (Gde-E-250) quality ‘A’ complete all as specified and as directed.
M&L Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thickof an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws all as specified and as directed.
M&L Pre painted galvalume aluminium zinc coating GI based plain steel sheet in ridges 0.50mm thickof an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws all as specified and as directed.
M & L Preparation of new steel surfaces over 10cm width or girth and priming with red oxide primer and painting with synthetic enamel painting two coats all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard / dense soil complete all as specified and as directed.
Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and as directed.
Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate)as in sub base floor 100mm thick etc all as specified and directed.
Chequered tiles 30cm x30cm x25mm thick set and jointed and pointed in neat in floors over 20mm thick screed bed in CM 1:4 bedded and jointed in grey cement slurry with pigment all as specified and directed.
pmv.enterprises (BID ID -3420755)
VIJAYALAKSHMI ENTERPRISES (BID ID -3419908)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .