GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPTIAL DELHI CANTT-110010
PROVN OF TRANSFORMER AT TRAUMA CENTRE, PROVN OF DEFI UPS SYSTEM AND CONNECTED ITEMS FOR ELECTRO MEDICAL DEVICE (VENTILATOR RO PLANT) ETC AT COVID-19 ICU ARMY DIALYSIS CENTRE AT AND REPAIR/ REPLACEMENT OF UNSERVICEABLE POINT WIRING, FITTING/ FIXTURE
2021_MES_419486_2
GE/BH-78/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSPTIAL DELHI CANTT
Class D Category b(ii)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹84,600
Yes
11 Jun 2021
1 Apr 2021
23 Apr 2021
1 Apr 2021
21 Apr 2021
7 Apr 2021
Amount
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable, heavy duty with stranded aluminium conductor 11000 Volt grade of size 3 Core, 95 Sqmm earth system complete all as specified and as directed.
Supply, installation, testing and commissioning 315 KVA, 11/0.433KV, AN, Oil Type Transformer with corrugated off circuit tap links of rating +5 to - 5% @2.5 %.by means of hand operated off load tap changing gear 315 kVA capacity transformer copper wound step down outdoor type, 11000/433 Volt (at no load), double wound, oil immersed naturally cooled with external cooling tubes, core type delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol Dy-II (vector group) with neutral brought on secondary side (LV side) and having tapping changing at + /-7.5% in step of +/- 2.5 %, to be changed and the maximum temperature rise shall not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be comprised with the following standard fittings including necessary foundation with block masonry work complete all as specified and as directed with following specifications, standard fittings (As elaborated in Srl No 2.01 here in after): - Note:- Transformer shall be double copper wound (Level -02) as per IS : 1180 (Part -1) 2014 with HT, LT cable Box.
(i) Pressure Release Valve (ii) Thermometer pocket on tank cover (iii) Oil temperature indicator with 2 contacts alarm & trip (iv) Rating plate with terminal marking (v) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip (vi) Oil level gauge (vii) Oil drain filter valve (viii) Lifting lugs (ix) Oil filter hole with cap/plug including connection complete (x) Four plain solid cast steel detachable rollers (xi) First fill of transformer oil confirming to relevant IS and testing upto 60 KV di-electric strength (xii) PCC Foundation with block masonry & Plaster work as per manufacturer's instruction and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning diesel Engine driven generating set of 160 KVA capacity, 3 phase, 4 wire, 415 V, 1500 RPM, AC power supply, with power factor 0.8, coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features), modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application/ installation, integrated design there by facilitating/ easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary weather proof shed with MS pipe 80mm dia for column and 40mm dia MS pipe for beam and arms with CGI sheets and PCC foundations with block masonry work and plastering complete all as specified and as directed with following specifications (As elaborated in Srl No 3.01 to 3.07 here in after):-
(A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 160 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002. The Engine shall consist of the following :- (i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan (Blower type) with guard (ix) Mechanical governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters (mounted) (xii) 12 V self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type) (xviii) Turbo charger (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet.
(xx) Instrument panel complete with the followings accessories:- (a) Auto manual Starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure . (k) Over speed stop with double driven adopter .
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation. Brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364. (ii) Type:- Self excited self regulated with automatic voltage regulator . (iii) Rating:- 160 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed: - 1500 RPM (v) System:- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected . (vii) Enclosure :- Screen protected drip proof . (viii) Ventilation :- Self ventilated. (ix) Insulation :- Insulation class H
(C) CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 160 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS complete all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF:- (a) Fuel tank -one No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features :- (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Fuel PUMP: - Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel. (c) Sealed maintenance free Battery :- Heavy duty battery two Nos 24 plates 12 Volt, 180 AH connected to the system, fully charged including lead and battery terminal's complete . (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all as specified by the manufacturer.
Supply, installation, testing and commissioning 11 KV, 630 Amps, outdoor type Compact switch gear Ring Main unit Extensible type, "CCV+ M" having 02 Nos. Load Break Switches and 01 No Vacuum circuit breaker all Motor Operated modules (Total number of modules 3 Pcs + 1 Metering modules), with IP class as IP 54 for outer door separately, inside the RMU there shall be an additional cable door with IP3X and Mimic of IP2X and necessary PCC foundation work as per manufacturer instructions and as directed by Engineer In Charge along with bottom cable entry and front cable termination complete all as specified and directed with following specification & Accessories (As elaborated in Srl No 4.01 to 4.06 here in after):-
(A) 630A Motorised Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity - 02 Nos. Short time withstand current - 21KA/ 3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38kV Impulse withstand voltage - 95kVp Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for motor operation Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 01 Set (R,Y,B) Set of 03 Nos. Ring Core Metering CTs 150-300 - 02 Nos as per feeder load, 2.5VA, Class 1.0 - 1 No
(B) 630A Motorised VCB module for making & breaking of fault current along with Earth Switch of full making capacity - 01 No. Motorised operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch. “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec Making Capacity - 52.5 kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 38KV Impulse withstand voltage - 98 KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Green(ON)/ Red(OFF) push buttons to operate VCB. 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Mechanical ON/OFF/EARTH/Spring charge Indication Cable boxes shall be Arc Proof interlocked with respective Earthing Switches. Right angle non-touch proof Termination boots - 01 Set (R,Y,B)
Stored energy mech. for motor operation - 01 No. Control voltage, motor operation 24 V DC - 01 No. Self Powered OC+EF Protection Relay - 01 No. Set of 03 Nos. Ring Core Protection CTs of ratio 40-80A - 01 No as per feeder load, 2.5VA, 10P10 - 01 Set Set of 03 Nos. Ring Core Metering CTs of ratio 40-80A - 01 No as per feeder load, 2.5VA, Class 1.0 - 01 Set Capacitive voltage indication fixed type VPIS 6-12 kV - 01 No. Aux. Relay for generating Potential Free Contact from Capacitive Voltage Indicator - 01 No. Metering Module Type M Safe Plus M shall be an air insulated metering module.
Set of 03 Nos. single-phase potential transformers having ratio 11kV/rt3:110V/rt3, 25VA, Class 1.0 with HRC fuses for protection on primary side and MCBs for protection on secondary side. - 01 No. Space Heater (230VAC) - 01 No. Low Voltage Box inside the metering enclosure for mounting:- 01 No. • Multifunction Meter for each feeder • CSPC make Under/Over Voltage Relay • 2x12VDC Battery+Charger scheme • R-Y-B Phase Indication Additional equipment delivered separately or mounted in respective panel. Set of Coupling busbars along with suitable coupling kit. - 01 No. Manometer - 01 No. Operating handle - 01 No.
Notes for Item No 4.00:- (a) RMU shall be IAC AFLR 20kA/1s tested with gas release from top of the Switchgear to ensure utmost operator & pedestrian safety. Test report (from an STL member Lab) shall be submitted along with drawings of the RMUs. In case the test report is not found suitable, the RMU shall stand liable to be rejected. (b) The Vacuum Bottle shall be of same make as that of RMU to ensure better life cycle optimization for the RMU. (c) Additional items like Operating handle etc. shall be delivered with the RMU. (d) RMU shall be completely motorised with all SCADA contacts, terminated on a designated Terminal Block for easy take off by the SCADA team for integration. Same contacts shall be clearly mapped in the Engineering drawings for approval with designated TB Nos. for easy identification and integration. (e) RMU tank shall be of 304 grade, Non-magnetic, Non-ferrite Stainless Steel. Inferior Grade of Steel shall not be acceptable. (f) RMU shall have site replaceable bushings for ease of trouble shooting at site and quick repair and restoration at site.
Notes for Item No 4.00 (Contd...):- (g) Earth switch should be on line side and should have making capacity. (h) Contractor shall purchase RMU directly from OEM and necessary factory inspection shall be arranged before dispatch RMU from OEM premises. The testing officer shall be nominated by accepting officer after written confirmation received from contractor for RMU is ready for testing with all respect as per CA provision. All testing and inspection shall be carried out in OEM premises in presence of testing officer and contractor. The joint inspection report shall be submitted after completion of testing. All expenditure in this respect shall be bore by contractor and inclusive in quoted rate. No other charges admissible to contractor in this respect after ward. (j) The quoted rates shall be inclusive of making Platform as per OEM instructions made with Brick work, PCC at Bottom and Top and plastering complete all as directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and as directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note: for measurement purpose punned thickness of sand only shall be considered.
Supply and Laying burn brick size 225 mm X 113 mm X 75 mm etc complete all as specified and as directed.
S&F cable jointing kit for 11 KV earth grade cable for Indoor type termination, Hot shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and directed.
S&F cable jointing kit for 11 KV earth grade cable for outdoor type termination, Hot shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm, 3 Core complete all as specified and as directed.
S&F cable jointing kit for 11 KV earth grade cable for straight through Joint, cold shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, 3 Core, Indoor/Outdoor type complete all as specified and as directed.
Supply, laying, connecting and testing electric cable XLPE insulated, screened, PVC inner sheathed, armoured with galvanised steel strip or wire, electric power cable of size 95 Sqmm, 3.5 Core, heavy duty with stranded aluminium conductor 1100 Volt grade, laid in trenches / duct, passing through pipe/ duct or fixed on pole complete all as specified and directed.
M&L sub main wiring with 2 runs of 2.5 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 2.5 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 2.5 Sqmm cable and one run of 2.5 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 11 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 12 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F Loadline distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, MCCB DB, VTPN, 8 way, with 250 Amps rated copper busbar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 47 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F MCCB TP, 125 Amp, 25 KA, DPX3, Thermal Magnetic, 420 Volts complete all as specified and as directed.
S & F MCB SPN, 240 Volts, 32 Amps, C curve, complete all as specified and directed.
S & F MCB SP, 240 Volts, 6 to 32 Amps, C curve, complete all as specified and directed.
S & F MCB SP, 240 Volts, 40 Amps, C curve, complete all as specified and directed.
S & F MCB SPN, 240 Volts, 63 Amps, C curve, complete all as specified and directed.
S&F rigid, Non metallic, PVC conduit, 32 mm external dia, medium grade, including all fittings such as tees, bends, elbow, reducers, bell mouth tube end and fixing accessories such as coupler, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 25X4 mm GI earth strip electrode welded and riveted to earth plate up to a distance of 7.5 metre long, GI earth strip encased in and including 32mm bore GI light grade pipe, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Supply, installation, testing and commissioning 30 KVA, online UPS with inbuilt isolation transformer and connected Battery Rack and link & Accessories including battery bank suitable for 30 Minuit back up with 2 Set of 20 Nos, 12V/65AH Batteries & battery racks and terminal link with Battery fuse box and including connected accessories along with Mod Bus Card for connecting to UPS to BMS through RS485 & monitoring through BMS with development of android App for remote monitoring as per OEM standards with and including connected accessories as per OEM standards complete all as specified and as directed. Note: The detail specification for UPS specified in PS.
Taking down carefully copper/ aluminium point wiring (Light, fan, socket, power and Bell) complete, including unscrewing from board out let boxes, fitting and fixtures such as switches, sockets, ceiling roses, lamp, holder brackets, ceiling/wall light fittings and regulators etc and making good disturbed surface of walls, floors, etc. complete all as specified and as directed.
M&L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 20mm dia or as per site requirement with all fittings, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed.
All as per item No. 29.00 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed.
All as per item No. 29.00 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed.
All as per item No. 29.00 here in before but for one light point controlled by two Nos, two way switches complete all as specified and as directed.
All as per item No. 29.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
All as per item No. 29.00 here in before but point wiring with 4.0 Sqmm, multistranded, copper conductor cable, for AC Point outlet on independent board with 4.0 Sqmm size earth conductor complete all as specified and as directed.
M&L point wiring for normal switches with 1.5 Sqmm, single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through existing concealed, Conduit including cadmium plated screws as per ISI, including replacement of 3 mm thick phenolic laminated sheet top covers on and including 1.2 mm thick sunk type CI/steel terminal box, concealed in wall, including 1.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed.
All as per item No. 35.00 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed.
All as per item No. 35.00 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed.
All as per item No. 35.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.
All as per item No. 35.00 here in before but point wiring with 4 Sqmm, multistranded, copper conductor cable, for AC point on independent board with 4 Sqmm size earth conductor complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 1 or 2 module complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 4 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 8 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 12 modules complete all as specified and as directed.
S&F in replacement modular cover plate with frame, 16 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 1 or 2 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 3 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 4 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 6 modules complete all as specified and as directed.
S&F in replacement modular metal flush box, 8 modules complete all as specified and as directed.
S&F in replacement module metal flush box, 12 modules complete all as specified and as directed.
S&F in replacement module metal flush box, 16 modules complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular switch, 2 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular bell push, 6 Amp, 1 Module complete all as specified and as directed.
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular switch, 1 way, 16 Amp, 1 Module, complete all as specified and as directed.
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.
S&F in replacement modular Fan step regulator, 120W - 2 module complete all as specified and as directed.
S&F in replacement Plug Top, 5 Amps, 230 Volts, white, polycarbonate body, 3 pin type, including connecting complete all as specified and as directed.
S&F in replacement Plug Top, 15 Amps, 230 Volts, white, polycarbonate body, 3 pin type, including connecting complete all as specified and as directed.
S&F in replacement Lamp holder, white, Polycarbonate body, with back plate, suitable for batten fittings, fixed in position & connecting complete all as specified and as directed.
S&F in replacement Ceiling rose, PVC/ polycarbonate, isolated body type, three terminal, 240 volt, fixed in position & connecting complete all as specified and as directed.
S&F in replacement Bell ding dong, AC, 230 Volts, fixed in position & connecting complete all as specified and as directed.
S&F in replacement Switch Piano type, white polycarbonate body, 5 Amp, 230 V, single pole, one way, including connecting complete all as specified and as directed.
S&F in replacement Switch Piano type, white polycarbonate body, 15 Amp, 230 V, single pole, one way including connecting complete all as specified and as directed.
S&F in replacement Socket outlet 2 in 1, 3 pin, 5 and 15 Amp, 230 V, Multipurpose, flush type, including connecting complete all as specified and as directed.
S&F in replacement Socket outlet 2 in 1, 3 pin, 5 Amp, 230 V, flush type, including connecting complete all as specified and as directed.
S&F in replacement stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete all as specified and as directed.
M&L in replacement sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L in replacement sub main wiring with 2 runs of 6.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 6.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 6.0 Sqmm cable and one run of 6.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
M&L in replacement sub main wiring with 4 runs of 10.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 40 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and 2 run of 10.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Four run of 10.0 Sqmm cable and Two run of 10.0 Sqmm earth conductor along with 40 mm PVC conduit with accessories shall be measured as one length)
S & F in replacement Loadline distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, MCCB DB, VTPN, 4 way, with 250 Amps rated copper busbar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 45 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F in replacement Loadline distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, MCCB DB, VTPN, 8 way, with 250 Amps rated copper busbar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 47 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F in replacement Loadline distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, MCCB DB, VTPN, 12 way, with 250 Amps rated copper busbar, 415 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 48 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F in replacement distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 12 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F in replacement distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 11 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
S & F in replacement distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 10 or equivalent model of Make mentioned in Appx 'B' to Particular specifications.
Supply, fixing and connecting in replacement recessed Type, Full window, opal Diffuser, Ultra modern, slim LED Panel 2x2, 36W, size 595X595mm (Nominal), suitable for Existing false ceiling, with CRCA powder coated White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 3KV, safety & performance test as per IS:15885 Part 2/Sec, Total system Lumen not less than 4200, in Cool day Light (5700K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours, complete with all accessories as required complete all as specified and as directed. Make : Havells Model No:- STRATO 2X2PLR36WLED857MOD with LED Driver Model No LEDDRIVER36V36WS or equivalent model of Make mentioned in PS.
Supply, fixing and connecting in replacement Surface/Wall Mounted, 9 Watt, integrated LED, 2 feet Fitting with Epoxy powder coated white polycarbonate channel housing. Total system Lumen of 9W LED shall be 800 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>100 Lm/w, THD(%) < 20, Complete with all accessories as required complete all as specified and as directed. Make- Havells Cat part No- LUMILINEBS9WLED865SPCWH or equivalent model of Make mentioned in PS.
Supply, fixing and connecting in replacement Surface/Wall Mounted, 20 Watt, integrated LED, 4 feet Fitting, with polycarbonate housing & opal diffuser finish, Integral electronic driver with Output short circuit protection, Surge Voltage Protection of minimum 3 KV and Safety test as per IS15885 Part 2/ Sec 13. Total system Lumen shall be 2000 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy 100 Lm/w, THD(%) < 20, LED with Average life of 50000 Burning hours. Complete with all accessories as required complete all as specified and as directed. Make- Havells Cat part No- LUMILINEBS20WLED865SPCWH or equivalent model of Make mentioned in PS.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and riveted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
S&F in replacement capacitor 2.5 Mfd complete all as all as specified and as directed.
S&F in replacement capacitor 3.15 Mfd complete all as all as specified and as directed.
S&F in replacement capacitor 4.0 to 8.00 Mfd complete all as all as specified and as directed.
S&F in repair switch socket combination, 5/15 Amp, multipurpose, with PVC gang box complete all as specified and as directed.
S&F in repair switch socket combination, 5 Amp, multipurpose, with PVC gang box complete all as specified and as directed.
S&F in repair modular blanking plate, 1 Module complete all as specified and as directed.
S&F in repair white colour, prelaminated sheet (Hylam Sheet), 8x5 inch size, 3 mm thick complete all as specified and as directed.
S&F in repair white colour, prelaminated sheet (Hylam Sheet), 5x5 inch size, 3 mm thick complete all as specified and as directed.
S&F in repair PVC Gang box, 3x3 inch, for switch socket combination 5A complete all as specified and as directed.
Cutting chases, pinning in, including making good in cement mortar 1:3 including painting to match with the existing surface as in edges of landings, steps, cills, sunshades, shelves, lintels, etc; and for concealed conduit wiring, etc, cutting not exc10 cm girth complete all as specified and as directed.
S&F in replacement sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed.
S & F in replacement MCCB, four pole, 125 Amp, 25 KA complete all as specified and as directed.
S & F in replacement MCCB, four pole, 100 Amp, 35 KA complete all as specified and as directed.
S & F in replacement MCB SPN, 240 Volts, 63 Amps, C curve, complete all as specified and directed.
S & F in replacement MCB SPN, 240 Volts, 40 Amps, C curve, complete all as specified and directed.
S & F in replacement MCB SP, 240 Volts, 6 to 32 Amps, C curve, complete all as specified and directed.
S & F in replacement MCB SP, 240 Volts, 63 Amps, C curve, complete all as specified and directed.
D P ENTERPRISES
M/s Adhikari construction co.
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .