Loading…
Loading…
Tender Value
₹12.8 Cr
EMD Value
₹7.9 L
Closing Date
27 Jan 2026, 3:00 pmClosed
Provision of Signalling and Telecommunication Arrangements inconnection with Elimination of PSR in Magnesite yard as part of Doubling of track between Salem Junction and Omalur Junction.
MTP-SG-CN-2025-26-01-OT~SR
MTP-SG-CN-2025-26-01-OT
Open
Works - General
6 Months
Salem, Tamil Nadu
₹0
₹7.9 L
27 Jan 2026
6 Jan 2026
13 Jan 2026
Item Breakup - A1-Annexure-A1
500.00 of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above"
10.00 Class D Surge Protection Device f o r 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of t h e Engineer i n charge at site ( OBO, DEHN, PHOENIX, LPI, ZOTUP, H A K E L or better make).All other m iscellane o us m a t e r i a l s required for installation s h a l l b e s u p p l i e d b y the contractor.
1.00 291723.20 arrangements for EI/MSDAC buildings as per RDSO specifications as required for the EI system along with supply o f all required materials. Earthing shall b e carried out as per RDSO/SPN/197/2008 and RDSO Lr .No STS/L/SSI/CA/US&S D t 26.07.2011 forTypical Earthing connections for EI. Painting of earthing diagram as replica of the ground on backside wall o f relay room as per the instruction of Site In-charge.(Per unit= Per goomty/station)"
1.00 483896.58 Active Class ' A ' Protection w i t h Lightning E v e n t Counte r a s p e r R D S O S p e c No. SPN/197/2008 w i t h T h r e e Ye a r Warranty (Make Erico, LPI or Similar). This schedule includes s u p p l y o f 3 0 m t r s c a b l e for connecting Air terminal & earth as specified by O E M . ( a s p e r Technical Specification enclosed)"
100.00 no SG/CN/02/13 XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
100.00 drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
4.00 110V DC/24-40V, 5A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest
2.00 D C / 2 3 0 V A C , 2 K V A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest or IRS:S 82-92
115.00 2V, 200Ah - 1 c e l l a s p e r RDSO Specifications IRS S: 93/96 with Amnd 1 or latest
1.00 1307398.11 per RDSO Specifications RDSO/SPN/165 or l a t e s t ( T h i s schedule d o e s n o t include Batteries) As per drawing enclosed
50.00 o f t h e following capacities with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V- 80AH capacity
2.00 500VA capacity
2.00 - 500VA capacity at Power Room/Apparatus cases a n d connecting i t t o t h e relevant circuit as per approved circuit diagram using wire PVC 3/0.75mm copper and painting of particulars as per standard Railway practice. [PVC 3/0.75mm copper wire and all other miscellaneous materials shall be supplied by the Contractor]
21000.00 i n s u l a t e d Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
2000.00 Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
15000.00 Armoured, unscreened underground Railway Signalling Aluminium cable a s per IRS: S- 63/2014 REV.4"
3000.00 Armoured, unscreened, underground Railway Signalling Copper cable as per spec IRS.S.63/2014(Rev.4.0) or latest"
1000.00 Armoured, unscreened, underground Railway Signalling Aluminium power cable as per as per spec IRS.S.63/2014(Rev.4.0) or latest
2000.00 insulated Armoured, inscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
1000.00 B i n d e r T a p e d a n d P V C Sheathed Unarmoured Cable as per IRS:S: 76/89 with all latest amendments"
30000.00 0.9MM Dia a s p e r spec IRS:TC 30-05 with amd 5 or latest
9000.00 p e r R D S O Specification RDSO/SPN/TC/ 110/2020 Rev. 0 or latest
30000.00 p e rR D S O Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest
50.00 Thermo shrink jointing kit (RDSO specs No TC/77/2012 ( Re v. 3 ) w i t h amendment N o . 1 & 2 o r l a t e s t . & j o i n t i n g k i t t o be inspected b y RDSO) f o r 4 / 6 q u a d cable normal joint. The work includes excavation o f j o i n t p i t o f s i z e 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e instruction o f Railway representative at site.
10.00 c o m p l e t e f o r 6 Q u a d c a b l e s using thermoshrink jointing kit for LC's/stations
50.00 enclosure for armoured optical fibre cable c o n f o r m i n gt o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest
50.00 enclosure for armoured optical fibre cable c o n f o r m i n g to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest
100.00 RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as p e r t h e instructions o f Railway representative a t s i t e . ) as per drawing enclosed XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
2000.00 covering of G I Pipes/cables. Providing & L a y i n g in position c e m e n t concrete of specified proportion i n c l u d i n g c o s t of cement, centering a n d shuttering with 1:3:6 composition 1 Cement: 3 S a n d : 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and a l l other m isc materials required f o r the work should be supplied by Contractor).
300.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.65 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule.)
3000.00 for track crossing of cables, refilling of trench by ramming and consolidating i t as p e r the instructions of Railway representative at site after l a y i n g of D W C / RC C p i p e s . During excavation of trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. T h e depth o f 1 m trench shall b e fro m t h e bottom o f sleepers for track crossings. Laying o f cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule).
420.00 cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor.
900.00 cable laying in hard rocky area with off sets at b o t h e n d s d u l y supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e c l o s e d w i t h brick masonry abutments work so that no cable is exposed, The work shall be carried out as p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for t h e w o r k s h a l l be supplied by the Contractor]. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
f signaling/power/ Metre telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule).
300.00 0 . 3 m width throughout, w i t h e a r t h after laying of cables, and consolidating the trench by ramming and levelling."
f o u n d a t i o no f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating i t by ramming. T h e cable markers s h a l l be provided a t a n interval of 20 Mtrs. within station limits a n d 5 0 Mtrs. outside station l i m i t s t h r o u g h o u t t h e cable route, diversions a n d a l s o a t every track/road crossing."
1000.00 width of 200 mm where rock is visible from surface to a depth more than 300 mm up to 550mm, excavation of trench with width
200mmx200mm after laying of cable with / cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number o f days, refilling with excavated soil ramming and consolidation except i n bridges, culverts, level crossings, track crossings, cable pits, r o c k y soil including m a r k i n g o f cable alignment, clearing of debris etc., complete to the finished item of work as directed by s i t e in charge. D r g No.SK/CN/NEW/3. All thematerial is to be arranged by contractor
1000.00 Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm d i a HDPE pipe o r a n y other combination a s d i r e c t e d b y t h e site engineer) ( Supply o f H D P E p i p e i s not covered in this schedule)"
6000.00 cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated HDPE pipe. ( This includes Transportation o f materials from nominated stores to site)
5.00 as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest
7.00 as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest
7.00 per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
10.00 L E Da s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
5.00 o n L E D a s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
15.00 L E Da s p e r R D S O Specification SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
3.00 d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal pole 4.6m tall and 140 mm dia(Galvanised)
4.00 d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply o f colour light Signal pole 3.6m tall and 140 mm dia (Galvanised)
7.00 pole 140mm dia with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.
3.00 s u i t C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. a)Supply of ladder with platform (4.6m) for CLS(Galvanised)
4.00 s u i t C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. b)Supply of ladder with platform (3.6m) for CLS(Galvanised)
5.00 with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
2.00 complete w i t h surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
1.00 type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection a s per specification/ drawing/ description enclosed in this document. a)Supply of colour light Signal unit (4 aspect)
3.00 type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect)
3.00 type- complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
1.00 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. a) Supply of Junction type route indicator - 1 way
5.00 light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal
10.00 made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large
10.00 made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small
10.00 w i t h n e c e s s a r y i n s p e c t i o n a s per specification/ drawing/ description enclosed in this document.
2.00 facility of paging a n d talk-back including voice communication e q u i p m e n t with suitable switching arrangement a t the S i g n a l post and a t S M ' s r o o m a s per specification enclosed i n t h i s document. This includes drawl of tail cable through GI p i p e 25mm dia and 2 mtrs long duly clamped to Signal post w i t h b e n d as required at site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. The w i r i n g s h a l l b e d o n e using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing box, wire PVC 16/0.20mm a n d all other miscellaneous materials required for the w o r k shall be supplied by the Contractor].
10.00 Style 'QNA1K', DC Neutral line, 24V, 1000 ohms 6F.6B, contacts, front contacts metal to carbon and back contacts metal to carbon, complete with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S60, IRS:S 34, IRS:S 23 & RDSO Spec.No. STS/ E/Relays/UEA (PI) dt.30.05.97 (Annexure-II) (as applicable). The interlocking code for this unit shall be CDEKY.
10.00 (2F/2B)(Miniature, Tractive armature, AC Im m une , D . C B i a s e d Tr a c k Re l a y ) A.C. immunity level of 80 Volt A.C, coil nominal resistance o f 9 Ohms, confirming t o BRS s p e c n o . 9 3 9 A & 9 6 6 F 2 a n d RDSO specification N o . 8 4 / 8 8 o r latest. The interlocking c o d e f o r t h i s u n i t s h a l l be "ABEJX" XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
50.00 type , Style 'QN1',DC neutral line, 50V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34 & IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF.
50.00 type , Style 'QN1',DC neutral line, 50V, 12F.4B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34 & IRS:S 23 or latest. .The interlocking code for this unit shall be ABCEF.
10.00 type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF.
10.00 Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH.
25.00 a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/
10.00 relays with necessary inspection a s per specification/
10.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
5.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ L C control circuit (up to 8 relays/plug in type)
5.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ L C control circuit (up to 12 relays/plug in type) XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
3.00 frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f p l u g b o a r d s , relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ L C control circuit (up to 20 relays/Plug in type)
20.00 boards, connectors and retaining clips with necessary inspection as per specification
20.00 boards, connectors and retaining clips with necessaryinspectiona s per specification/drawing/
5.00 type of required ward Nos. with keys, with necessary inspection a s p e r specification/ drawing/
70.00 relays in the relay racks/apparatus cases as Relay per the approved circuit diagram using wire PVC 16/0.2mm c o p p e r. T h e work includes painting alterations a n d releasing the unwanted w i r e s c a r e f u l l y without disturbing the existing wiring.[Wire PVC
bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor].
1.00 708081.12 Highly sensitive smoke aspiration system for Monitoring of rooms and equipment's for earliest possible fi r e detection F o r Relay r o o m sa s p e r R D S O spec No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 311682.08 Fi r e Alarm system w i t h l o o p capacity of connecting maximum 50 devices. The panel shall have a built in power supply and b a t t e r y c h a r g e r R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest.
13.00 Optical/ Thermal as per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
2.00 to 92 d b A a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
5.00 m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 generation & routing in case of Fire Alarm to concerned p e r s o n s a s p e r RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest.
470.00 unarmoured cable a s per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
120.00 No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 155660.60 No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 CPVC Pipes with all required accessories for Aspiration system)
2.00 specification No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 charges o f fi r e a l a r m s y s t e m including programming of devices and fire alarm panel
2.00 C o m m i s s i o n i n g o f A s p i r a t i o n smoke detection
2.00 as per Technical specification
1.00 Re s i s t a n c e Te s t e r , a s p e r Technical specification
1.00 50V-500V/1000 mega ohm battery operated with all complete accessories, as per Technical specification
1.00 578788.99 Technical specification
1.00 186694.53 per Technical specification
1.00 specification
5.00 specification
600.00 103.5mm inner d i a & 1 2 0 m m o u t e r dia c o n f o r m i n g t o s p e c i fi c a t i o n N o . IS 14930(Part 2 ) : 2001 with o n e coupler for e v e r y 6 m o f p i p e a s p e r Technical specification
900.00 thick as per Technical specification
600.00 thick as per Technical specification XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
4000.00 (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s per specification N o . I S 4984: 2016 with latest amendments and Material Grade:PE 80
100.00 3M make or similar, Model: RFID (1421) and installation, cable detection o f capacity to detect the cable upto 5 feet depth.
6000.00 mm (inner dia) with couplers
50.00 with 4 terminals and stumps with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.
61.44 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre.
100.00 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre.
100.00 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse
1.00 diagram board in the station master's room. The board shall be made of Phynolic synthetic industrial fibre base fi n e weave cotton fibre board (matt finish) 6mm thick size 1800mm X 1200mm w ith aluminium channel frame. T h e y a r d layout shall be neatly painted a n d fixed a s instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor].
10.00 and supply of Ni-cad power pack 4V-2.2AH with charger to work on 110VAC
6.00 termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e c o a t of red-oxide a n d t w o c o a t s of aluminium paints. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
4.00 machine-IRS t y p e a n d c o n n e c t i n g all ground connections including wiring and termination in p o i n t m a c h i n e and interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw b a r lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e w o r k s h a l l b e supplied by the Contractor].
20.00 p e r standard practice. T h e w o r k involves scraping of old paint, applying one coat of R e d oxide a n d t w o coats o f Aluminium/ enamel paint on the Signals - complete as instructed by Railway representative at site.[Aluminium p a i n t , red-oxide a n d all other miscellaneous materials required for the work shall be supplied by the Contractor].
20.00 foundations for a width of 0.5m on all sides, up t o a l e v e l 1 5 0 m m b e l o w the foundation top. T h i s w o r k includes consolidation of earth by watering and ramming.The e a r t h s h a l l b e t a k e n from Railway premises as instructed by Railway representative at site.
7.00 foundation as per Drg.No.SG/CN/02/9 using metallic templates, f o r erection o f colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly o f size 20/25mm d i a a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
7.00 mounting o f colour l i g h t signal u p t o 4 aspects complete o n Signal pole/ Off-set bracket, ( f o r L E D / filam e nt b u l b s ) with lenses, triple p o l e l a m p holder, filament switching units, C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform c o m p l e t e and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of s p e e d l i m i t b o a r d wherever necessary, termination o f tail cables, wiring o f signal u n i t w i t h P V C w i r e 3 / 0 . 7 5 m m copper, provision of EWS locks, and painting of one c o a t o f r e d o x i d e a n d t w o c o a t s of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through b o l t s h a l l be provided by drilling a hole in the signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, curre nt regulators, l a m p holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, s t o n e jelly 20/25mm dia, M sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , paints P V C / N y l o n sleeves, enameled number p l a t e s . enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]."
2.00 foundation a s p e r D r g , No.SG/CN/02/10 using metallic templates, f o r erection of g r o u n d t y p e c o l o u r l i g h t s h u n t signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm a n d all other miscellaneous materials for the work shall be supplied by the Contractor]."
2.00 complete including surface base, signal pole, LED aspects/ l e n s e s , b u l b s with holders (whichever i s applicable), fixing of lens guards, number plate, termination of tail cables, wiring o f signal unit w ith PVC wire 3/0.75mm copper, provision o f EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. ( S u p p l y o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n t h i s schedule). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts a n d nuts, lead wool, paints and all other miscellaneous materials shall b e supplied by the Contractor]." XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
5.00 nuts, erection o f Post type shunt Signals, termination o f tail cables and wiring using w i r e P V C 3/0.75mm copper, provision of EWS lock and painting o f one coat o f red- "oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down."
1.00 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Route Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing and wiring o f direction type route indicator - 1 way
10.00 n u t s , erection o f Calling O n Signals/ 'A' marker lights, termination of tail cables and wiring using w i r e P V C 3/0.75mm copper, provision o f E W S l o c k , n u m b e r plates/ marker boards and painting. The work also includes drilling suitable holes o n t h e CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply of Calling o n Signal/ ' A ' marker light, L E D aspects/holders & bulbs and Off set brackets is not covered in this schedule).['U' bolts a n d nuts, through bolts with nut, wire PVC 3/0.75mm copper, E W S lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints a n d all other miscellaneous materials shall be supplied by the contractor].
1.00 m a s o n r y platform a s p e r d r a w i n g No. SG/CN/02/12 w i t h country bricks o f size 220mmx 100mmx60mm (app) a t t h e foot o f s i g n a l p o s t telephones a s p e r the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand and all other miscellaneous materials required for the work shall b e supplied by the Contractor]. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
4.00 circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone)
12.00 circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
5.00 suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration t o existing t r a c k circuits at feed end
5.00 suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f double bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d c o n n e c t i o n s wherever necessary using 2c x 2.5 sq.mm cable b)Alteration t o existing t r a c k circuits at relay end
30.00 foundation and erection o f apparatus case f u l l s i z e a s p e r D r g . No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another f o r t h e back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.]
20.00 foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' type loc k f o r t h e front d o o r and latching arrangement for the back door, and fixing o f o n e hardwood s h e l f plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor]""" XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
5.00 termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r cable throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with o n e c o a t of red-oxide a n d t w o c o a t s of aluminium paints.(Supply of CT boxes is not covered i n this schedule. Rails o f different length shall be supplied b y Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, stone jelly of size 20/25mm, p a i n t , varnish, G I Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for eac h pipe, fixing bolts a n d nuts with washers, E W S locks, paints a n d all other miscellaneous materials shall be supplied by the Contractor].
1000.00 existing terminals/ fuse blocks in apparatus c a s e s / batte ry b o x e s / C T b o x e s / cable termination racks a s p e r approved circuit diagram. The terminal particulars are to be repainted /corrected o n t h e d o o r s of apparatus c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created f o r e n t r y o f n e w c a b l e s i n the apparatus cases with masonry brick work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination racks w ith cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, brick s, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
5000.00 p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood items, fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l be closed with brick work, cement plastered, the inter-space filled with M s a n d u p to base level and the bottom surface shall be sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." a)Termination o n 25/60mm PBT terminals (new location) (Phynolic sheet)(Per Unit = Per Terminal block)
100.00 p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood items, fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l be closed with brick work, cement plastered, the inter-space filled with M s a n d u p to base level and the bottom surface shall be sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
3000.00 power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination b o x e s e t c . The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base l e v e l a n d t h e bottom surface s h a l l be s e a l e d w i t h sealing compound. a)Termination o f cables o n 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block)
70.00 power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination b o x e s e t c . The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed w i t h b r i c k work, cement plastered, the inter-space filled with M sand u p t o base l e v e l a n d t h e bottom surface s h a l l be s e a l e d w i t h sealing compound. b)Termination o f cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block)
apparatus (Outside) - Full size"
apparatus (Outside) - Half size"
1.00 Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
16.00 telephone communication at stations/ tents a s p e r t h e in s tru c tio n s o f Railway representative a t site. The P A system and magneto telephones will be returned to the contractor a f t e r t h e completion o f NI working. Signalling cables available may be used for the communication.(Hiring o f PA s y s t e m e q u i p m e n t s and magneto telephones shall be done by the Contractor) [All other miscellaneous materials required f o r t h e w o r k s h a l l b e supplied b y the Contractor]. (Per Unit= Per set per day)
16.00 sam e a t places a s instructed b y Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, tube lights and pedestal fan. Drinking water in cans.The t e n t s shall be fi x e d fi r m l y to withstand rain, strong wind etc.(Per Unit = Per tent per day)
4.00 Nicad pack
3.00 c r a n k handle o r o n suitable fixtures at station/apparatus c a s e , p r o v i s i o n of economiser push switch with locking facility, wiring w i t h w i r e P V C 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting.(Supply of electric key transmitter and crank handles i s not c o v e r e d i n t h i s schedule). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility b y u s i n g 2 5 m m thick teakwood, b o l t s a n d n u t s , p a i n t s , push switches, padlocks and other miscellaneous materials required for this work shall be supplied by the contractor].
2.00 and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
2.00 warning boards on rails as per the Signalling plan. T h e w o r k includes manufacturing of clamps a n d fi x i n g the board t o t h e rails, supply and fixing of scotch lite reflectors and concreting the rail post to a size of 600mm x 600mmx900mm. (Supply o f goods warning boards a r e not covered i n this schedule. Rails o f different lengths will be supplied by Railways and the Contractor h a s t o c u t t h e m t o the required lengths).[Stone j e l l y o f size 20/25mm dia , M sand, cement, M.S.flats, scotch lite strips (14 Nos) for each board, fixing bolts a n d nuts, paint and a l l other miscellaneous materials shall be supplied by the Contractor].
4000.00 Crossing/Road Cutting/Trenches
20.00 available in the path of cable trench (buried inside ground)
30.00 Half/ Quarter size) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, ' E ' t y p e l o c k s , e t c . , and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stack e d a t a p l a c e as instructed by Railway representative at site.
6.00 existing c a b l e termination b o x e s , after releasing the base plank, Terminal blocks, Fu s e Blocks, Terminal Boards, c u t rails, pipes, etc., closing t h e resultant pits and consolidating i t b y ramming a n d levelling. The released materials shall b e accounted and stacked neatly at a place as instructed by Railway representative at site.
6.00 Colour light Signals complete (upto 4 aspects) with or without Route Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking t h e concrete foundation,closing t h e resultant p i t and resurfacing it by ramming and levelling.
6.00 m a c h i n e s ( a l l t y p e s ) in c lu d in g ground connections and other accessories available complete w i t h o u t a n y d a m a g e t o the gadgets, accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. XSTE-CN-MTP-MSC-S AND T/SOUTHERN RLY
1.00 signals along with surface base, signal post e t c c a r e f u l l y w i t h o u t a n y damage, accounting and stacking them neatly a t a p l a c ea s instructed b y Railway representative a t s i t e . T h e w o r k also includes breaking and removal o f concrete foundation and refilling o f the resultant pit by ramming and levelling."
30.00 stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
2.00 r o u n d t h e c l o c k t o a t t e n d t h e teething trouble of the installation along with SSE/JE after the installation has been brought into commissioning. T h e work includes routine maintenance, failure restoration as per the direction of the SSE/JE
180.00 oriented technical manpower t o carryout Days works like Drawing, computation, writeup etc., using computer, using software like AUTOCAD, MS Office etc., for 08.00 hrs in a d a y w i t h all expenses of transportation, accommodation, food, consumables etc., w i t h a l l ascents, descents, taxes, octroi, cess, fees, duties, duties w ith contractors c o s t e t c . , a s per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be c o n v e r g e n t w i t h computer working knowledge in above software.
210.00 S & T gears by deputation of Days Helpers/Unskilled Labour for executing additional S & T portion o f t h e works. The w o r k can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative.
500.00 r o a d a s p e r t h e instructions o f Railway representative a t s i t e . T h e w o r k also includes loading a n d unloading o f the materials a)Transportation o f Signalling materials upto 100kms
200.00 than 100km
100.00 or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., w i t h a l l leads a n d lifts etc., complete and a s p e r t h e instruction of Railway representative at site. Total 69788801.89
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].